Telemark 861 Specification sheet

1801 SE Commerce Avenue Tel 360-723-5360 [email protected]Battle Ground, WA 98604, USA Fax 360-723-5368 www.telemark.comMADE IN USAJ2REMOTE CONTROLJ1HOSTJ3 OUTPUTPOWER90-264 VAC, 47-63 Hz5A SLO-BLO FUSEXY SWEEPJ1HVPS - HV CONTROLJ3SUB CONTROL #2J5REMOTE USER I/OJ6HANDHELDJ2HVPS - SOURCE CTRL J7INTERLOCKSTELEMARK -TT BACK PANELJ4SUB CONTROL #3861TT/ST POWER SUPPLY CONTROLLERINDEXERMOTORPOWER90-264 VAC, 47-63 Hz5A SLO-BLO FUSEINDEXERFEEDTHRUJ1HOSTETHERNET ONLY
SOURCE
POWER115V/230V, 50/60Hz2A SLO-BLOI/O1I/O2I/O3I/O413241,23,4
SENSORSENSORSOURCE
CAUTIONRS232
OSCILLATOR
SOURCECRYSTAL SENSORModel 861 Quick SetupTYPICAL SYSTEM CONFIGURATIONCRYSTAL SHUTTERSOURCE SHUTTERDo not mix up the oscillator RJ45 cable and an Ethernet RJ45 cable
Model 861 Quick Setup31801 SE Commerce Avenue Tel 360-723-5360 [email protected]Battle Ground, WA 98604, USA Fax 360-723-5368 www.telemark.comMADE IN USA1BEFORE INSTALLING DEPOSITION CONTROLLERThe 861 can be operated with 0 to 4 I/O cards installed. There are 3 types of I/O cards:37 pin with 8 inputs and 8 outputs plus a dedicated “abort” output (360/860 pinout)25 pin input (880 pinout)25 pin output.(880 pinout)If ordered with 37 pin I/O card(s) from the factory with the proper setting then this step can be skipped. The 37 pin I/O card has jumpers that need to be set for Active or Passive Input operation. Passive input is TTL level inputs activated by a short across input pins. Active input is activated by 12 to 24 volts DC across the input pins. To change setting remove the controller cover and move jumpers on PC board. The 25 pin input card has both Active and Passive pins available .2INSTALL DEPOSITION CONTROLLERThe 861 is designed to be installed in a 19 inch rack.Required power: 90-264 VAC, 47-63 HzThe 861should be proper grounded, see manual for more details.GroundSource/Sensor 3,4Source/Sensor 1,2I/O Slot 1PowerI/O Slot 2I/O Slot 4I/O Slot 3ETHERNET ONLY
SOURCE
POWER115V/230V, 50/60Hz2A SLO-BLOI/O1I/O2I/O3I/O413241,23,4
SENSORSENSORSOURCE
CAUTIONRS232EthernetRS-232INSTALL CRYSTAL SENSOR AND OSCILLATORThe 861 is designed to be used with:- 5 or 6 MHz crystals - Internal vacuum coaxial cable, 30 inches long (from crystal sensor to feed through)- External BNC cable, 6 inches long (from feed through to oscillator)- Telemark oscillator (other oscillators will not work)- Shielded RJ45 cable, to 25 feet long (from oscillator to 861)OscillatorOscillator CableBNC CableCrystal SensorNotes:- The full manual is found on the included USB drive in pdf form.- The 861 boots up to the splash screen 30 seconds, and the configuration screen in under 2 minutes.- The 861 is shipped with crystal simulation turned off, if crystal sensor one is not connected then the crystal error will sound when the 861 is turned on.- The 861 is shipped with the 6MHz setting and screen saver set to 15 minutes.
Model 861 Quick Setup1801 SE Commerce Avenue Tel 360-723-5360 [email protected]Battle Ground, WA 98604, USA Fax 360-723-5368 www.telemark.comMADE IN USA4CONFIGURING THE 861 SYSTEM, see the 861 manual for more detailsFull manual is found on the included USB drive in pdf form
1. Setup – Display: Parameters affecting the display 2. Setup – Utility: Miscellaneous parameters such as, crystal frequency, sound volumes, date and time 3. Setup – Source: number of pockets, shutter, indexer, source voltage, etc. 4. Setup – Sensor: number of crystals, shutter, indexer, etc. 5. Setup – Inputs: Setup of user defined inputs and system defined inputs. User defined inputs are used to trigger outputs and actions. System defined inputs are automatically created by the 861 for source and sensor selection feedback. After the inputs are created the D connector pins can be changed if needed. Setup outputs and actions may need to be changed after materials and processes are defined because they can be used in condition strings 6. Setup – Outputs: User defined outputs and system defined outputs. User defined outputs can be triggered by condition strings. System defined outputs are automatically created by the 861 for source and sensor selection and shutter control. After the outputs are created the D connector pins can be changed if needed. 7. Setup – Actions: 16 internal user programmable actions can be used to provide special functions upon the true evaluation of a condition string. These functions may be such things as terminating a deposit on an input from an optical monitor or sounding an alarm when certain events are true.
DEFINE MATERIALS AND PROCESSES, see the 861 manual for more details
1. Materials: Parameters affecting the deposition of each material: density, impedance, source#, pocket#, sensor#, etc. 2. Process: Describes the layers of a process. Once a material has been created in the 861 then it can be added to a process layer and given a thickness. There can be up to 99 layers per process.
5Typical process profile of one layer defined by material settings0100%PowerTime
Start “Soak Rise”Start “Soak Hold”Start “Predeposit Rise”Start “Predeposit Hold”Start “Establish Rate”Start “Deposit #1” (Open Shutter)Start “Rate Ramp #1”End “Rate Ramp #1”End deposit (Close Shutter)Start “Ramp To Idle”Start “Idle”
Idle4 possible ramps
End LayerStart Layer
Model 861 Quick Setup1801 SE Commerce Avenue Tel 360-723-5360 [email protected]Battle Ground, WA 98604, USA Fax 360-723-5368 www.telemark.comMADE IN USA6OPERATING THE 861 SYSTEM,see chapter 6 of the 861 manual for more detailsFull manual is found on the included USB drive in pdf formADDITIONAL NOTES:The USB drive supplied with the 861 is for backing up and restoring materials, processes, and all the system files. It is also useful for data logging. It also includes a 861 pdf manual, 360/860 conversion software and VNC software and other Telemark information.The supplied handheld remote is for manually adjusting powerwhen in “Manual” mode and for activating “Abort” at any time.The 861 can be viewed and controlled remotely via Ethernet and a VNC client (Remote Desktop),see chapter 4. The network needs to have a DHCP server to automatically supply the 861 with an IP address.See chapter 7 to see the how to tune the material control loop parameters referred to as PID parameters (Proportional gain, Integral Time constant and Derivative Time constant).See chapter 8 for details about control of an 861 from computer/PLC using the RS-232 serial interface. The interface is set at 9600 Baud, 8 Bit data, No Parity, 1 Stop bit7
MANUAL BUTTON This button is used to toggle the 861 Manual mode on and off. The Manual mode indicates that the source control voltage output is being controlled through the Remote Power Handset START BUTTON The Start button starts a process, starts a layer, resumes an aborted process, or notifies the 861 that the pocket or crystal is in position. ABORT BUTTON The Abort button puts the 861 into the Abort mode. RESET BUTTON The Reset button is used to clear the controller from Abort mode and put it into the Ready mode. ZERO BUTTON Pressing the Zero button causes the thickness display to go to zero. This button is active at all times SHUTTER BUTTON This button is used to manually open and close the active source shutter. STATUS BUTTON This button is used to cycle through the different status screens. The display settings allow the six different status screens to be active or not. Refer to chapter 6 for a detailed description of these status screens. PROGRAM BUTTON Pressing the programming button will bring up the main programming screen.

Other Telemark Controllers manuals

Telemark 880 User manual

Telemark

Telemark 880 User manual

Telemark DIGITAL SWEEP User manual

Telemark

Telemark DIGITAL SWEEP User manual

Popular Controllers manuals by other brands

Atmel AT43301 manual

Atmel

Atmel AT43301 manual

Regin AQUA230T instructions

Regin

Regin AQUA230T instructions

Watts T156B Series manual

Watts

Watts T156B Series manual

Mitsubishi Electric FX3U-64DP-M installation manual

Mitsubishi Electric

Mitsubishi Electric FX3U-64DP-M installation manual

Woodward UG-5.7 Dial Installation and operation manual

Woodward

Woodward UG-5.7 Dial Installation and operation manual

Dea NET-BOX operating instructions

Dea

Dea NET-BOX operating instructions

Datalogic Controller SC6000 Quick reference guide

Datalogic

Datalogic Controller SC6000 Quick reference guide

KING UC1000 user manual

KING

KING UC1000 user manual

VARIZOOM VZ-ROCK operating instructions

VARIZOOM

VARIZOOM VZ-ROCK operating instructions

NOVAK GTB 2 - ANNEXE 536 TRACK GUIDE manual

NOVAK

NOVAK GTB 2 - ANNEXE 536 TRACK GUIDE manual

Aprimatic M230HR manual

Aprimatic

Aprimatic M230HR manual

Nectar Sun S user manual

Nectar

Nectar Sun S user manual

Bioptechs FCS2 instructions

Bioptechs

Bioptechs FCS2 instructions

Aruba Networks 7030-MNT-19 installation guide

Aruba Networks

Aruba Networks 7030-MNT-19 installation guide

Minco 830 manual

Minco

Minco 830 manual

HORNER XLE-Model 2 instructions

HORNER

HORNER XLE-Model 2 instructions

Smartgen HAT160 user manual

Smartgen

Smartgen HAT160 user manual

Pearl Malletstation EM1 user manual

Pearl

Pearl Malletstation EM1 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.