Teletype Basic KSR Operating instructions

e
the
113
teleprinter
T.M
.
TELETYPE
,
InrI:'
REPAIR MANUAL
for
BASIC
TERMINALS
without
an
Internal
Data
Set

©
1978
by
Teletype Corporation
All rights reserved
Printed
in
U.S.A.

REP
AIR
MANUAL
391
The
43
TELEPRINTER
REPAIR MANUAL
Comments concerning
content,
usability,
and
adequacy
of
this manual will
be
welcomed. This
sheet
may
be removed
and
mailed directly
to
Teletype
Corporation. This
sheet
may
also be used
for
ordering additional copies
of
this manual.
Comments
to:
Order manuals from:
Mail To:
Teletype Corporation
5555
Touhy
Avenue
Skokie,
IL
60076
Dept.
3212
Dept. 2181-3

The
43
TELEPRINTER
REPAIR
MANUAL
INTRODUCTION
REPAIR
MANUAL
391
Issue
1,
April
1978
This
manual
provides
complete
repair
information
for
43
Basic
Teleprinter
Terminals
without
an
internal
data
set
(modem)
and
major
components.
The
manual
is
intended
for
field
or
shop
use
and
is arranged
into
various
parts
that
include repair, servicing
and
how
to
operate
instructions
for
the
43
Basic
KSR
and
RO
Sprocket
or
Friction
Feed
Teleprinters,
with
an
EIA
interface
or
a
TTL
interface. Manual
369
provides
complete
servicing
information
for
all versions
of
the
Basic
43
Teleprinter.
All replaceable
components
are identified in
the
manual along
with
disas-
sembly,
adjustments
and
troubleshooting
information.
Waveforms are
included
on
wiring diagrams
and
charts
are provided
for
additional
trouble
isolation using
an
oscilliscope
or
volt-ohmmeter.
No specially designed
tools
or
shop
facilities are required
for
repair operations, however
standard
43
teleprinter
terminals
or
components
or
local strapping
may
be
required
to
perform
or
simulate on-line
and
interface
testing when
the
teleprinter
is
not
installed
on
location.
The
43
Teleprinter Circuit Diagram, Manual
385,
provides
circuit
informa-
tion
extracted
from
this
manual.
The
component
layouts, lead designations
and
schematic diagrams
for
each circuit are
combined
into
single
fold-out
sheets
for
the
convenience
of
field
or
shop
personnel
when
repairing
major
components.
The
task
flow
chart
on
the
next
page illustrates
the
intended
repair
or
servicing activities
and
the
associated
manual
parts.
Spare
units
and
parts
for
repair are available
from
Teletype
Corporation.
Service personnel should
be
properly
trained
and
have access
to
these spares
before
attempting
service
or
repair
of
the
43
Teleprinter.
Contact
Teletype
Corporation
Technical Training Center,
312-982-3940,
for
courses available
on
43
Teleprinters.

PART
8
PART 9
PART
10
PART
11
The
43
TELEPRINTER
REP
AIR
MANUAL
TABLE
OF
CONTENTS
PART
1
PART
2
PART
3
PART
4
PART
5
PART
6
PART
7
TESTING
TROUBLESHOOTING
DISASSEMBL
Y AND REASSEMBLY
CIRCUIT DESCRIPTION AND DIAGRAMS
ADJUSTMENTS AND SPRING TENSIONS
PARTS
AND UNIT CODES
PACKING AND MARKING
SUPPLEMENTAL MANUALS INCLUDED
KSR INSTALLATION AND
ROUTINE
SERVICING MANUAL
368
Issue 3
RO INSTALLATION AND ROUTINE SERVICINGMANUAL
373
Issue 2
KSR HOW
TO
OPERATE
MANUAL
367
Issue 2
RO HOW
TO
OPERATE
MANUAL
372
Issue 2

TASK
FLOW
CHART
+
" !
DISASSEMBLY
AND
REASSEMBLY
PART 3
r
......
~
INTRODUCTION
"
TESTING
" +
I
I
I
REPAIR
MANUAL
391
PART
1
TROUBLESHOOTING (Isolation and Correction)
PART
2
l
":
+
" !
CIRCUIT
DESCRIPTIONS
AND
DIAGRAMS
ADJUSTMENTS
AND SPRING
TENSIONS
PART 4
PACKING
AND
MARKING
PART 5
STATION INSTALLATION
AND
VARIABLE
FEATURES
"
ROUTINE MAINTENANCE
AND LUBRICATION
,r
.4
~
STATION
OPERATION
{
~
" I
I
PARTS AND
UNIT CODES
PART
6
KSR Installation
and Servicing
Manual
368
RO Installation
and Servicing
Manual
373
KSR
How
to
Operate
Manual
367
RO
How
to
Operate
Manual
372
PART
7
PART 8
PART
9
PART
10
PART
11

MANUAL
391,1-1
PART
1-
TESTING
CONTENTS PAGE
1.
GENERAL
....................
1
2.
TEST
EQUIPMENT
.............
2
3.
KSR
TESTING
.................
3
OFF-LINE
TESTS
...............
3
VARIABLE
FEATURES
CHECKOUT
...................
12
A.
Loopback
Mode
............
12
B.
Variable Features
Checkout
...
12
4.
RO
TESTING
..................
15
OFF-LINE
TESTS
...............
15
VARIABLE
FEATURES
CHECKOUT
...................
20
A.
Loopback
Mode
............
20
B. Variable
Features
Checkout
20
1.
GENERAL
1.01
This
part
provides testing
requirements
and
procedures
for
the
43
Basic
KSR
and
RO
Teleprinter.
1.02
The
information
in
this
part
is
intended
to
determine
if
th~
terminal
and
its
compo-
nents
are
operating
properly
and
will
continue
to
operate
for
extended
periods
under
normal
oper-
ating
conditions.
1.03
Endurance,
environmental
extreme
or
electrical
parameter
testing
information
is
not
provided in
this
part.
This
type
of
information
is
found
to
some
extent
in
Part
2,
Troubleshooting
and
is
used
to
isolate
and
correct
troubles
indicated
in
this
part.
1.04
The
testing
information
provided herein
should
normally
be
used
to
determine
if:
(a) A repaired
teleprinter
is
operating
properly
before
being
returned
to
a
customer
or
placed in service.
(b) A questionable
component
installed
in
the
teleprinter
operates
properly
or
requires
repair.
(c) A questionable teleprinter, in service
or
received
from
a
customer,
is
operating
properly
or
requires repair.
1.05
Following installation
or
routine
mainten-
ance calls
at
a
location,
either
the
testing
in
this
part
or
an
installation
checkout
using
the
HTO
manual should
be
performed
to
make
sure
the
teleprinter
is operational.
1.06
On
trouble
calls, a local
test
or
a
trouble
verification
test
under
the
direction
of
a
test
station
(if available) should
be
performed
to
isolate
the
trouble
within
or
to
the
teleprinter.
After
correction
of
a
trouble,
the
test
may
be
confined
to
the
specific
area
that
was failing.
1.07
The
checkout
routines
are
presented
in
table
form
with
test
conditions
arranged
in a specific sequence. A response is given
to
verify
the
test
condition
has
passed.
1.08
Always
perform
the
tests in
the
order
given.
The
test
steps are based
on
satis-
factory
results
of
all previous steps.
1.09
If
the
indicated
response is
not
obtained
in
any
step
of
a
test
procedure,
repeat
the
step
to
make sure
that
the
procedure
has
been
performed
properly.
If
the
results
are
still unsatis-
factory,
refer
to
Page 2-1, Troubleshooting.
1.10
Teleprinters
with
TAUs
or
with
no
Ter-
minal
Data
Unit
must
be
associated
with
locally developed
external
testing
arrangements
and
procedures
to
perform
actual
On-Line Tests.
If
test
station
is
remote,
a
copy
of
the
testing
procedure
should
be
available
at
the
test
station.
Note:
The
local
tests
specified
in
this
part
simu-
late
most
on-line
tests
for
these
teleprinters.
--1.11
Before
an
on-line
test
can
be
performed,
the
remote
testing
station
must
be
pro-
vided with advance details
about
the
teleprinter
under
test,
such as,
telephone
number,
type
of
terminal
(KSR
or
RO) (friction
or
sprocket)
option
exceptions
present,
speed,
etc.

391,
1-2
1.12
Before proceeding
with
the
checkout
procedure,
check
the
following:
(a) Is
teleprinter
connected
to
a properly
grounded
and
polarized ac
outlet?
(b) Are all cable
connectors
fully seated?
(c) Are
printer
paper
and
ribbon
properly
installed?
(d) Are
any
option
exceptions
present?
Refer
to
Manuals
368
(KSR)
and
373
(RO),
Page 2-1.
(Part
8
or
9)
Procedures in Off-Line Tests are based
on
standard
factory
furnished
options
being present.
If
option
exceptions
are present,
the
test
response will
be
as
shown
in
the
KSR
or
RO
Variable
Features
Checkout.
1.13
All references
to
columns
are
after
a one-
second delay,
to
allow
the
print
head
to
index
two
character
spaces
to
the
right.
The
print
head
indicates
the
next
character
position
to
be
printed.
2.
TEST
EQUIPMENT
2.01 Off-Line
and
Variable
Feature
Test pro-
cedures are provided
to
simulate On-Line
Tests where
external
communication
test
devices
are
not
available.
To
perform
these
tests,
the
connector
terminals, as follows, should
be
strapped
before
proceeding
with
the
tests.
The
remaining
terminals should
be
connected
or
measured as
specified
during
the
test
steps.
Note:
Contact
Teletype
Corporation
Sales
Department,
312-982-2000,
for
availability
of
a
43
Teleprinter
Interface
Test
Box, which pro-
vides
both
arrangements
shown
as follows:
EIA INTERFACE
TTL
INTERFACE
:S
SEND DATA
~~
RECEIVE
DAT,&
RECEIVE DATA SEND DATA
5 CLEAR TO SEND
.:
TERMINAL READY
6 DATA SET READY f
DATA TERM READY DATA READY
25)
ANALOG LOOP V +5V Use
volt
7)
GND
11)
·12V
meter.
4)
REQUEST TO SEND
1~
+12V (Indica-
~
GND
tors
pro-
1)
DIGITAL LOOP vided
on
3)
ANALOG LOOP
Test
6)
REQUEST TO SEND
box.)
2.02
A
43
KSR
Operator
Console,
43K101/
CAA
or
CAB
can
be
substituted
in
RO
Teleprinters
to
perform
tests
and
variable
feature
checks off-line
when
external
communication
test
devices are
not
available
for
on-line
operation.
2.03
A
volt-ohmmeter
or
equivalent means
to
measure ±12volts
and
+5volts
and
perform
continuity
checks is required.

3.
KSR TESTING
OFF-LINE TESTS
TEST
Power
On/Off
Printer
Option
431.a.
432.a.
STEP
1.
2.
3.
TABLE A
OFF-LINE TEST PROCEDURES
PROCEDURE
ON
t
OFF
(Rear
View)
~PRINT
HEAD
MARKER
I 10
~
"PRINT
INDICATOR
SCALE
Hold
PRINTER
TEST
key
depressed
until
approximately eight lines are printed.
MANUAL
391,1-3
RESPONSE
Print
head returns
to
the
left-hand margin.
Paper feeds
to
next
line.
TERM READY (AUTO
ANSW)
turns
on.
Print
head
marker
points
to
first
mark
on
indicator
scale.
ALARM
and
LOCAL
(LOCAL-TALK)
turn
on.
Characters
printed
as
in
Fig.
1.
(Refer
to
Options
431
and
432b
and
c
for
any
exceptions.)
Bell rings
at
end
of
each
line. (Right-Hand Margin
and
Test Message.)
Note
1:
First line
may
start
with
any
character
for
sprocket
or
friction feed printers.
~nopqrstuvwxyZ{:
}
....
• ".tX&/().+,-.IOt23456789:;<=>!@ABCDEF6HIJKLMNOPDRSTUVUXYZ(\]h_'abcdefghiJklMnopqrstuvwxyz{
}N
• ".tX&'()*+,-.IOt23456789:;<=>?@ABCDEFGHIJKlHNOPURSTUVUXYZ[\)'_'abcdefghiJklMnopqrstuvwxyz{
}H
• ".tX&'()*+,-.IOt23456789:;<=>!@ABCDEF6HIJKLHNOPDRSTUVUXYZ[\]'_'abcdefghijklMnopqrstuvwxyz{ }P
• "'$X&'().+,-.I0123456789:;<=>?@ABCDEF6HIJKLHNOPDRSTUVUXYZ(\]h_'abcdefghijklMnopqrstuvwxyz{
}H
• ".tX&'().+,-.IOt23456789:;<=>?@ABCDEF6HIJKLHNOPGRSTUVUXYZ[\]h_'abcdefghijklMnopqrstuywxyz{
}H
• "'$X&'()*+,-.IOt23456789:;<=>?@ABCDEF6HIJKLMNOPGRSTUVUXYZ[\]h_'abcdefghijklMnopqrstuvwxyz{
}N
• "ItX&'().+,-.IOt23456789:;<=>?@ABCDEF6HIJKlMNOPGRSTUVUXYZ[\]A_'abcdefghijklMnopqrstuvwxyz{
}N
• "'$%&'().+,-.IOt23456789:;<=>?@ABCDEF6HIJKLMNOPDRSTUVUXYZ[\]h_'abcdefghijklMnopqrstuvwxyz{
}N
Sprocket Feed -
13
Characters
per
inch
See
Note
1.
Note
2:
The lower case
"0"
/ does
not
print
on
80
character line.
"tllVW>:YZ{:}"
\
•
'"I.X&'().+,-./01234567891;<=>?@ABCDEFGHIJKlHNOPQRSTUVUXYZC\J~_'abcdefghiJkl"~
pqrstuyw)(yz{I}"
•
~"I.X"().+,-.I0123456789:;<=>"ABCDEFGHIJKlHNOPQRSTUVUXYZC\]h_'abcdefghiJkl"n
pqrstuywxyz{!}"
•
!"N.X&'()*+,-./0123456789:;<=)?IABCDEFGHIJKlHNOPQRSTUVUXYZC\JA_'abcdefghijkl"n
pqrstllYW)(Yz{:}"
•
!"N.%&~()*+,-./Ot23456789:;<=)?@ABCDEFGHIJKlHNOpaRSTUVUXYZ(\JA_'~bcdefghijkl"n
pqrstllYWXYz{:}-"'
Friction Feed
-10
Characters
per
inch
Fig. 1

391,
1-4
KSR OFF-LINE TEST (Cont)
TEST STEP
Printer
4.
(Cont)
Operator
5.
Console
6.
TEST STEP
Operator
7.
Console
(Cont)
8.
9.
TABLE A (Cont)
OFF-LINE TEST PROCEDURES
PROCEDURE
Release
PRINTER
TEST key.
Hold CTRL
key
depressed
and
depress RETURN
key.
Place CAPS LOCK
key
in
DOWN position.
Starting with
top
row and moving from
left
to
right, depress unshaded keys
in
Fig. 2.
RESPONSE
ALARM
turns
off.
Character printing stops.
Print head is
returned
to
left-hand margin
and
paper
feeds
to
next
line.
Characters
printed
as
in
Fig. 3.
Fig. 2
1234567890-+'OWERTYUIOP=\ASDFGHJKL;~{ZXCVBNM,.1
Fig. 3
'1
23456?890-+
···qwer'tyuiop:=\asdf'3hjkl;··
{z;.:cvbnf"l,
.1
Fig. 4
TABLE A (Cont)
OFF-LINE TEST PROCEDURES
PROCEDURE
Depress RETURN
and
then
LINE
FEED
key.
Depress
and
release CAPS LOCK
key
so
it
returns
to
UP position. Starting with
top
row
and
moving
left
to
right, depress each unshaded
key
in Fig. 2.
Depress RETURN and
then
LINE
FEED
key.
RESPONSE
Print
head
is
returned
to
left-hand margin
and
paper
feeds
to
next
line.
Characters
printed
as
in
Fig. 4.
Print head returns
to
left-
hand
margin
and
paper
feeds
to
next
line.

TEST STEP
Operator 10.
Console
(Cont)
TEST STEP
Operator
II.
Console
(Cont)
12.
13.
14.
15.
TABLE A (Cont)
OFF-LINE TEST PROCEDURES
PROCEDURE
Hold left SHIFT key depressed and starting with
top
row and moving from left
to
right, depress
each unshaded key in Fig. 5. Hold right SHIFT key
depressed
and
depress
rn
key.
Fig. 5
!
@#$:.~
;"
(~:t:
( )
...
]
....
1:·
[ : :
II
}<>
'?'f
Fig. 6
TABLE A (Cont)
OFF-LINE TEST PROCEDURES
PROCEDURE
Depress RETURN and then LINE FEED key.
Hold
CTRL
key
depressed
and
depress
~
S~B
~
key.
Hold
CTRL
key
depressed
and
depress
~
"ilL
~
key.
Hold
CTRL
key
depressed
and
depress
rn
key. H
Depress SPACE BAR.
lV1ANUAL
391,
1-5
RESPONSE
Characters printed
as
in
Fig.
6.
RESPONSE
Print head returns
to
left-
hand margin and paper
feeds
to
next
line.
SUB prints 8
Signal bell rings.
Print head moves
one
character position
to
the
left.
Print head moves
one
character position
to
the
right.

391,1-6
KSR OFF-LINE TESTS (Cont)
TEST
Operator
Console
(Cont)
Cover
Inter-
lock
Right
Margin
and
Signal
Bell
Margin
Set
and
Clear
(Remem-
ber
Lower
Case)
STEP
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
TABLE A (Cont)
OFF-LINE TEST PROCEDURES
PROCEDURE
Depress BACK SPACE key.
Depress LINE FEED key.
Depress
and
hold
REPT and
rn
keys.
Depress TERM READY (AUTO ANSW) key.
Raise cover.
Close cover.
Depress RETURN and
the
LINE
FEED
key.
Space
print
head
to
column
125
(sprocket feed).
(See
1.13)
Space
print
head
to
column
73
(friction feed).
Depress
~
""Ii'
~
key.
Depress SPACE BAR six times.
Depress SPACE BAR
two
times.
Depress ESC
and
then
~
c~
~
key. (ESCx)
Depress SPACE BAR nine times.
Depress ESC and
then
rn
key.
(ESCL lower case.) L
RESPONSE
Print
head
moves
one
character position
to
the
left.
Paper feeds
to
next
line.
The k
is
printed
until
end
of
line
is
reached.
, Signal bell rings
at
end
of
line.
TERM READY (AUTO
ANSW) goes off. LOCAL
(LOCAL-TALK)
and
ALARM
turns
on.
ALARM goes off.
Print head returns
to
left-
hand margin
and
paper
feeds
to
next
line.
Signal bell operates as
character b
is
being
printed.
Signal bell does
not
oper-
ate. Print head moves six
character positions
to
the
right.
Signal bell operates
two
times.
Print head returns
to
left-hand margin and indi-
cates beginning
of
line.
Print head moves
to
Column 10.

TEST
STEP
Margin
26.
Set
and
Clear
(Cont)
27.
28.
29.
30.
3l.
TABLE A (Cont)
OFF-LINE
TEST
PROCEDURES
PROCEDURE
Space
print
head
to
Column
5l.
Depress ESC and
then
~
D~2
~
key. (ESCr)
Depress
RETURN
key.
Depress BACK SPACE key.
Space
print
head
to
Column 50.
Depress SPACE BAR.
Depress SPACE BAR.
Depress ESC
and
then
mkey (ESCm)·
Depress SPACE
BAR
four
times.
Depress ESC
and
then
~
EJ:
~
key
(ESCw).
MANUAL
391,
1-7
RESPONSE
Print
head
returns
to
left
margin
(Column
10).
Signal bell rings.
Signal bell operates.
Print
head
indicates
Column
5l.
Signal bell rings.
Print
head
remains
at
Column
5l.
Print
head
moves
to
Column
55.
Print
head
returns
to
left-
hand
margin
(Column
10)
and
paper
feeds
to
next
line.
Turn
off
POWER switch
and
connect
the
test
arrangement
shown
on
Page 1-2
to
the
interface
connector
before
proceeding
to
Step
32.
If
the
43
Teleprinter Interface
Test
Box
is available,
connect
the
test
box
to
the
teleprinter
interface
connector
(TTL
or
EIA). See instructions furnished
with
test
box.
TEST
STEP
Loopback
32.
~---
32.a.
TABLE A (Cont)
OFF-LINE
TEST
PROCEDURES
PROCEDURE
Place
teleprinter
in
loopback
mode:
Perform 32 a
or
32
b.
1------------------
EIA
INTERFACE
-
Connect
Carrier
Detect
to
Data
Term
Ready.
Turn
on
Teleprinter
POWER switch.
RESPONSE
1----------
Print
head is
returned
to
left-hand margin.
Paper
feeds
to
next
line.
DATA
turns
on.
EIA
INTERFACE
CONNECTOR
+
12
V will
be
present
on
pin4 (Issue
2A
Logic Card)
GND will be
present
on
pin
7.

391,
1-8
KSR OFF-LINE TESTS (Cont)
TEST
STEP
Loopback
32.b.
(Cont)
----
Option
33.
434.a.
34.
----
Option
35.
433.a.
----
36.
37.
TABLE A (Cont)
OFF-LINE TEST PROCEDURES
PROCEDURE
TTL
INTERFACE -
Connect
Terminal Ready
to
Data
Ready.
Measure
continuity
between
pins 6
and
9
on
TTL
interface
connector.
Tum
on
Teleprinter POWER switch.
Depress
and
release PARITY
key
to
UP position
(PARITY ON).
Place DUPLEX
key
in
UP
position (HALF-
DUPLEX).
Place CAPS LOCK
key
in DOWN position.
Type
the
following:
ANALOG
Depress SPACE BAR.
Place DUPLEX key.in DOWN position
(FULL
DUPLEX).
Type
the
following:
TEST
Watch TERM READY (AUTO ANSW)
key,
then
hold
CTRL
key
depressed
and
depress
~
E~T
~
key.
Depress
INTRPT
key.
Hold CTRL
key
depressed
and
depress RETURN
key.
RESPONSE
Print
head
is
returned
to
left-hand margin. Paper
feeds
to
next
line. Meter
should read 0
ohms
(Issue
2A
Logic Card).
DATA
turns
on.
INTERFACE
CONNECTOR
+5 V
dc
will be
present
on
pin
7.
-12 V
dc
will
be
present
on
pin
II.
+
12
V
dc
will
be
present
on
pin
13.
GND will
be
present
on
pin
9.
AANNAALLOOGG is
printed.
(Refer
to
Option
434b
for
any
exceptions).
TEST is
printed.
DATA
and
TERM READY
(AUTO ANSW) indicators
flash as EOT key
is
depressed.
(Refer
to
Option
433b
for
any exceptions.)
INTRPT
turns
on
momentarily.
Signal bell rings.
Print
head
does
not
return.

TEST
Loopback
(Cont)
Option
435.a.
Option
435.a.
Low
Paper
(Friction
Feed)
Paper-Out
(Sprocket
Feed)
STEP
38.
39.
40.
41.
TABLE A (Cont)
OFF-LINE TEST PROCEDURES
PROCEDURE
Depress RETURN and
then
LINE FEED key.
Depress REPT
and
K keys.
Hold
down
until
two
lines
of
Ks
are printed.
(Check
time
to
print
line.)
Place
CPS
key
in
DOWN position. (10 CPS.)
Depress REPT
and
K keys.
Hold
down
until
two
lines
of
Ks
are printed.
(Check time
to
print
line.)
Remove
the
paper
-paper-out (sprocket feed).
Lift paper roll from
paper
support
-(friction
feed).
Watch DATA key
and
depress LINE
FEED
key eight times.
MANUAL
391,
1-9
RESPONSE
Continuous
Ks
will
be
printed
across entire
new
line.
Bell rings
at
end
of
line
and
automatic
return
and line
feed will
be
performed. One
printed
line plus
return
will
occur
in approximately:
4 seconds (sprocket feed)
2.5 seconds (friction feed)
(Refer
to
Option
435b
for
any exceptions.)
Continuous
Ks
will
be
printed
across
entire
line.
Bell rings
at
end
of
line
and
automatic
return
and
line feed will
be
performed.
One
printed
line plus
return
will occur
in
approximately:
14
seconds (sprocket feed)
8.5
seconds (friction feed)
First
part
of
second
line
(approximately
18
char-
acters) will
be
printed
at
a
faster
rate
of
speed.
(Refer
to
Option
435b
for
any
exceptions.)
Signal Bell rings (sprocket
feed only).
Alarm
turns
on.
S:Qrocket Feed
DATA
turns
off. LOCAL
(LOCAL-TALK)
turns
on
as
8th
LINE
FEED
is
received.
Friction Feed
DATA remains
on.
LOCAL
(LOCAL-TALK) remains
off.

391,1-10
KSR
OFF-LINE
TESTS
(Cont)
TEST
STEP
Low
42.
Paper
(Friction
Feed)
Paper-Out
(Sprocket
Feed)
(Cont)
43.
44.
Loopback
45.a.
Clear
----
45.b.
Analog
46.
Loop
47.
TABLE A
(Cont)
OFF-LINE
TEST
PROCEDURES
PROCEDURE
Depress
TERM
READY (AUTO ANSW)
key.
Replace
the
paper.
Depress
DATA
key.
EIA
INTERFACE
-
Disconnect
strap
between
Data
Term
Ready
and Carrier
Detect.
------------------
TTL
INTERFACE
-
Disconnect
strap
between
Data
Ready
and
Terminal Ready.
I
-
Depress ESC
key.
Hold
SHIFT
key
depressed
and
depressIT]
key.
Depress ESC
key
and
then
m
key.
RESPONSE
SQrocket
Feed
DATA
remains
off.
LOCAL (LOCAL-TALK)
remains
on.
Friction
Feed
DA
TA
turns
off.
LOCAL (LOCAL-TALK)
turns
on.
Alarm
turns
off.
DATA
turns
on.
LOCAL (LOCAL-TALK)
turns
off.
TERM
READY
(AUTO
ANSW)
turns
on.
DATA
turns
off.
ALARM flashes
EIA
INTERFACE
CONNECTOR
DATA
turns
on.
TERM
READY
(AUTO
ANSW)
turns
off.
+12
V will
be
present
on
interface
pin
25
(Analog
Loop).
TTL
INTERFACE
CONNECTOR
oV will
be
present
on
TTL
interface
pin
3 (Analog
Loop).
ALARM
turns
off.
EIA
INTERFACE
CONNECTOR
DATA
turns
off.
TERM
READY
(AUTO
ANSW)
turns
on.
-12 V will
be
present
on
interface
pin
25
(Analog
Loop).
TTL
INTERFACE
+5 V
dc
will be
present
on
interface
pin
3 (Analog
Loop).

TEST
STEP
Digital 48.
Loop
49.
Low
50.
Paper
(Friction
Feed)
Paper-Out
(Sprocket
Feed)
51.
52.
53.
TABLE A (Cont)
OFF-LINE
TEST
PROCEDURES
PROCEDURE
TTL
INTERFACE
-Depress ESC key.
Hold
SHIFT
key
depressed
and
depress
rn
key
TTL
INTERFACE
-Depress ESC key
then
mkey.
Sprocket
Feed
-Remove paper.
Friction
Feed
-
Lift
paper
roll from
paper
roll
support.
~
Depress TERM READY (AUTO ANSW) key.
Replace
the
paper.
Place CPS
key
in
UP
position
(30
CPS)
Place DUPLEX
key
in
UP
position
(HALF-
DUPLEX).
MANUAL
391,
1-11
RESPONSE
oV will
be
present
on
TTL
interface pin 1 (Digital
Loop).
+5 V
dc
will
be
present
on
TTL
interface
pin 1
(Digital
Loop).
Signal bell rings
(sprocket
feed only).
TERM
READY
(AUTO
ANSW)
turns
off.
LOCAL (LOCAL-TALK)
and
ALARM
turn
on.
TERM
READY
(AUTO
ANSW) remains off.
LOCAL (LOCAL-TALK)
and
ALARM
remain
on.
ALARM
turns
off.
This
completes
the
OFF-LINE
test
of
the
43
KSR
Teleprinter. Use local
procedures
and
arrangements
for
ON-LINE testing.

391,1-12
KSR VARIABLE FEATURES CHECKOUT
3.01
The
procedures in Tables
Band
C verify
proper
operation
of
variable features
exceptions only.
The
features as furnished from
A.
Loopback
Mode
the
factory are checked in
the
Off-Line Tests in
Table A.
3.02
Off-line
checkout
of
Options
433b,
434b,
and 435b will require placing
the
tele-
printer
into
the
loopback
mode
(see Table B).
TABLE B
LOOPBACK MODE PROCEDURES
PROCEDURE RESPONSE
EIA
INTERF
ACE -Connect
the
test
arrangement Print head returns
to
left-hand margin.
shown
on
Page 1-2
to
the
interface connector. Printer performs one line feed.
Connect
Carrier
Detect
to
Data
Term Ready. DATA
turns
on.
Turn
on
Teleprinter POWER switch.
TTL
INTERF
ACE -Connect
the
test
arrangement
shown
on
Page 1-2
to
the
interface connector.
Connect
Terminal Ready
to
Data
Ready.
Tum
on
Teleprinter POWER switch.
B.
Variable Features Checkout
TABLE C
VARIABLE FEATURES CHECKOUT PROCEDURES
CHECK PROCEDURE RESPONSE
Option
Depress
and
hold
PRINTER
TEST key. Characters printed as in Fig. 6.
431.b. Bell sounds
at
end
of
each line.
and c.
(Option
431.b.)
•
!",.%&,()*+,-./J'234567B9:;<=>T@ABCDEFGHIJKLHN~PGRSTUVUXYZ[\J!!'abCdefghijkl~nOpqrstuvwXYZ{:}N
(Option
431.c.) + f H
•
!"It%&'()*+,-./0123456789:;<=>?@ABCDEFGHIJKLHNIPQRSTUVUXYZ[\J
••
'abcdefghijkl~nopqrstuvwxY2{:}N
Fig.
6-Printer
Test
Message

MANUAL
391,
1-13
TABLE C
(Cont)
VARIABLE
FEATURES
CHECKOUT PROCEDURES
CHECK PROCEDURE RESPONSE
Option
Depress
and
hold
PRINTER
TEST
key. Line length will
be:
432.b.
432
b -
72
characters
andc.
432
c -
80
characters
Characters
printed
as in Fig. 7.
Bell sounds
at
end
of
each line.
Note:
The
lower
case
"g"
does
not
print
on
72
character
lines.
*(Option
432.b.)
/
•
!"'.ZI~C)*+,-.I0123456789:;<=>!'ABCDEFGHIJKLHNOPQRSTUVUXYZ[\]A_
'abedef
hijkl"nopqrstuvwxyz{I}N
•
!"'.ZI'C)*+,-.I0123456789:;<=>!@ABCDEFGHIJKLHNOPQRSTUVUXYZ[\]~_'abedef
hijkl"nopqrstuvwxyz{l}" Note:
The
lower
case
"0"
does
*(Option
432.c.)
not
print
on
80
character
lines.
•
!"'.ZI'C)*+,-.I0123456789:;<=>!@ABCDEFGHIJKLHNOPORSTUVUXYZ[\]A_'abcdefghijklMn
'
pqrstuvwxyz{I}N
•
!"'.Z&'C)*+,-.I0123456789:;<=>!@ABCDEFGHIJKLHNOPORSTUVUXYZ[\]h_'abcdefghijklMn
pqrstuvwxyz{l}"
*Sprocket
Feed
(13
characters
per
inch), Friction Feed (10 characters
per
inch)
Fig.
7-Printer
Test
Message
TABLE C (Cont)
VARIABLE FEATURES CHECKOUT PROCEDURES
CHECK PROCEDURE RESPONSE
Option
Place
teleprinter
in
loopback
mode.
433.b.
Depress DUPLEX
key
to
DOWN
position
(FULL
DUPLEX).
Depress
the
following keys:
ABC Printer will
print
ABC.
Hold CTRL
key
depressed
and
DATA remains
on
(does
not
flash).
depress
ij
EgT
~
key.
TFiRM
READY (AUTO ANSW) remains
off
(does
not
flash) as
EOT
key
is
depressed.

391,1-14
TABLE C
(Cont)
VARIABLE
FEATURES
CHECKOUT
PROCEDURES
CHECK
PROCEDURE
RESPONSE
Option
Place
teleprinter
in
loopback
mode.
434.b.
Depress
DUPLEX
key
to
DOWN
position
(FULL
DUPLEX).
Printer
will
print:
••
Rrr.
TE.T
Depress
and
release
PARITY
key
to
UP
position
(PARITY
ON).
Place CAPS LOCK
key
in
DOWN
posiiton.
Depress
the
following keys:
PARITY
TEST
Option
Place
teleprinter
in
loopback
mode.
Characters
will be
printed
until
end
435.b.
Place
DUPLEX
key in DOWN
position
of
line is reached.
(FULL
DUPLEX).
Automatic
return
and
line feed will
not
be
performed.
Depress
REPT
and
K keys. Bell will
sound
continuously
until
Hold
down
until
end
of
line is reached.
keys
are released.
Note:
Options
433,
434,
and
435
-Depress LOCAL (LOCAL-TALK)
key
to
terminate
checkout
pro-
cedure.
Disconnect
Interface
Test
Arrangement
if
present.
This manual suits for next models
1
Table of contents
Other Teletype Touch Terminal manuals