Installation Instruction
1. Tape template to the door and mark and drill holes where necessary.
2. Attach Fixing Trim Posts into the holes of front plate.
3. Attach lockset device to the door:
1st: Screw two Top Bolts thru Battery Bracket, thru door and into Lockset,
2nd: Attach Bottom Fixing Bolt into Fixing Post using Metal Flange when necessary.
4. Run battery wire terminal through the Wire Hole as indicated.
5. Attaching exit device to the door:
1st: Screw Top Fixing Bolts into top Fixing Posts
2nd: Attach bottom of exit with thru bolts (sold separately)
6. Fit the Spindle from the rear side spindle hole to the front plate.
7. Attach panic device to fixing posts, then at point insert fixing screws onto fixing post at point.
8. Plug in Battery Pack to the Lockset, place the wires into the door and attach Battery Pack to Bracket with Cover.
Provided
Front Plate
Bottom
Fixing Bolt
Top Fixing
Bolts
Spindle
(marked
L or R)
Fixing
Trim
Posts
Thru-Bolts
(sold separately)
Thru-Bolts
(sold separately)
Battery Bracket
Wire Hole
Battery Pack/
Cover
Top Bolts
Metal
Flange
Lockset
CL5000 Electonic Lock Trim
Using the template on page 2, install the CL5000 Lock Trim with the Exit Device. Tape
template to the door, mark the holes and drill where needed.