Tema Telecomunicazioni FXO Series User manual

Revision
Date
Revision reason
Prepared
Checked/Approved
3 13-09-2016
Update GM, GBC DP
MAS-AA514-REV03EN Page 1 of 56
AA-514
Analog Doorphone with 4 buttons
for connection to PBX extension (FXO)
AA-516P additional 8 buttons module
AA-516K additional keyboard module
AA-516R additional index module
TECHNICAL MANUAL – INSTALLATION
PRELIMINARY DOCUMENTATION
AA-514 system manual - Version HW 2.0 – FW 2.8
Recommendations
1. Use only original spare parts and consumables supplied by Tema Telecomunicazioni Srl for this equipment. The company shall not be
held responsible for anydamage caused bythe use of materials that they have not supplied.
2. The device has been carefully manufactured and tested. In any case, the product is not recommended for use in situations in which
incorrect operating may result in damage to persons and/or property.
3. We recommend that you carefully read all this manual before starting to use the device.
4. Do not expose the device to sunlight and protect it from sources of heat, dust, humidityand chemical agents.
5. This manual is the property of Tema Telecomunicazioni Srl and any duplication and reproduction, even partial, as well as storage on
any type of media is forbidden without written permission from Tema Telecomunicazioni Srl.
TEMA
TELECOMUNICAZIONI S.r.l.
Telecommunications - Electronics

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 2 of 56
We, TEMA TELECOMUNICAZIONI SRL Via C. Girardengo, 1/4 - 20161 MILANO
declare under our sole responsibility that the product:
product name Interfaccia Citotelefonica – Door Phone
trade name TEMA TELECOMUNICAZIONI Srl
type or model AA-514, AA-514A, AA-514H, AA-514HA
AA-514C, AA-514AC, AA-514HC, AA-514HAC
and accessories AA-516P, AA-516KA, AA-516KB, AA-516KC, AA-516R
to which this declaration relates is in conformity with the essential requirements and other
relevant requirements of the R&TTE Directive ( 1999/5/EC, 2006/95/EC, 2004/108/EC ).
The product is in conformity with the followings standards and/or other normative documents:
HEALT & SAFETY EN 60950-1:2006
+A11:2009
+A1:2010
+A12:2011
EMC EN 55022:2010
EN 55024:2010
EN 61000-3-2:2006
EN 61000-3-3 :2008
TERMINALE DI ES 203 021 – Access and Terminals (AT); Harmonized basic
TELECOMUNICAZIONE attachement requirements for Terminals for connection to analogue
interfaces of the Telephone Networks; Update of the technical contents of
TBR 021, EN 301 437, TBR 015, TBR 017
MILANO, 01 October 2013 TEMA TELECOMUNICAZIONI SRL
D. Pontillo
DECLARATION OF CONFORMITY (DoC)

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 3 of 56
I. IMPORTANT INFORMATIONS REGARDING THE RECOVERY AND RECYCLING OF THIS
ELECTRONIC DEVICE
The crossed-out wheeled bin symbol below indicates that this electronic equipment is intended to be disposed in a
separate collection and not in an unsorted municipal waste, in order to provide for the treatment of WEEE (Waste
Electrical and Electronic Equipment) using best available recovery and recycling techniques.
Specific treatment for WEEE is indispensable in order to avoid the dispersion of pollutants and other hazardous
substances into the waste stream, while recycling leads to reduction of disposal of waste and the negative impacts
on environment and human health. That is, priority is given to reuse of WEEE in its components, subassemblies
and consumables.
As the final holder, the user has an important role in contributing to reuse, recycling and other forms of recovery of
WEEE and is responsible to return this waste in the collection facilities set up by EC Member Stases and to fulfill
other duties in compliance with Directive 2002/96/EC and local laws.

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 4 of 56
1.
OVERVIEW..................................................................................................................................5
2.
MAIN
FEATURES.......................................................................................................................6
3.
PARTS
COMPRISING
THE
SYSTEM
(PACKING
LIST) ...........................................................7
3.1.
C
ROSS
-
REFERENCE TABLE OF FEATURES
/
SERVICES OF THE VARIOUS MODELS
.................................. 8
4.
TECHNICAL
SPECIFICATIONS...............................................................................................10
5.
OPERATION..............................................................................................................................12
5.1.
B
UTTONS AND NUMERIC KEYPAD EXPANSIONS
..............................................................................12
6.
OPERATING
MODES ...............................................................................................................14
6.1.
DAY
/
NIGHT
M
ODE
...............................................................................................................14
6.2.
DAY
/
NIGHT
MODE WITH CALL REPETITION TO THE SAME NUMBER
.................................................15
6.3.
GROUP
M
ODE
,
CYCLIC CALLS
..................................................................................................15
6.4.
A
DDITIONAL FEATURES OF THE KEYPAD EXPANSION
......................................................................15
6.5.
800
N
UMBERS FEATURE
...........................................................................................................16
6.6.
RELAYS
CONTROL WITH ACCESS CODES
...................................................................................16
6.7.
200
ADDITIONAL ACCESS CODES
S
PECIAL
F
UNCTION
....................................................................17
6.8.
C
ALLS GENERATED BY
AA-514 .................................................................................................17
6.9.
C
ALLS TO
AA-514...................................................................................................................18
6.10.
A
DDITIONAL FEATURES OF THE BUILT
-
INCAMERA AND THE DEDICATED FRONT LIGHTING
......................18
7.
COMMANDS
AND
CODES
FOR
THE
INTERNAL
OPERATOR.............................................19
7.1.
S
IGNALING
L
ED AND
AA-514
FRONT PANEL DESCRIPTION
..............................................................20
8.
INSTALLATION.........................................................................................................................21
8.1.
I
NSTALLATION OF SYSTEMS
.......................................................................................................21
8.2.
I
NSERTING OR REPLACING THE NAMES ASSOCIATED WITH THE BUTTONS
...........................................24
8.3.
CONNECTIONS ...................................................................................................................25
8.3.1.
C
ONNECTION OF THE BASE SYSTEM
AA-514........................................................................25
8.3.2.
C
ONNECTING THE SYSTEM EXPANSION
AA-516P
AND
AA-516K .............................................26
8.3.3.
C
ONNECTING THE SYSTEM EXPANSION
AA-516R..................................................................27
8.3.4.
C
ONNECTION OF THE BASE SYSTEM
AA-514C
WITH CAMERA
..................................................28
8.4.
D
ESCRIPTION OF THE TERMINAL BLOCKS OF RELAYS
.....................................................................29
8.4.1.
S
OLID
S
TATE RELAYS AND
E
LECTROMECHANICAL RELAYS
......................................................29
8.5.
D
ESCRIPTION AND EXAMPLES OF OPERATIONMODES WITH THE INTERNAL RELAYS
,
CONNECTIONS
........30
8.5.1.
CASE
1:
DRIVE TWO ELECTRIC LOCKS WITH SYSTEM POWERED WITH EXTERNAL POWER SUPPLY
..30
8.5.2.
CASE
2:
DRIVE OF TWO ELECTRIC LOCKS WITHSYSTEM POWERED WITH TELEPHONE LINE ONLY
...31
8.5.3.
CASE
3:
DRIVE OF TWO ELECTRIC LOCKS SYSTEM POWERED WITH
3
DIFFERENT POWER SUPPLIES
32
8.5.4.
CASE
4:
SYSTEM WITH SHARED POWER SUPPLYBETWEEN THE SYSTEM AND ELECTRIC LOCK
.......33
8.5.5.
CASE
5:
DRIVE OF AN ELECTRIC LOCK AND AN OPENING BUZZER
.............................................34
8.5.6.
CASE
6:
DRIVE OF AN ELECTRIC LOCK AND AUTOMATIC BACKLIGHT
D/N
WITH POWERED SYSTEM
.35
8.5.7.
CASE
7:
CONNECTION BETWEEN BASE UNIT AND EXPANSIONS
................................................36
8.5.8.
C
ONNECTING
AA-516R
MODULES IN CASCADE STARTING FROM A
AA-514
BASE MODULE
............37
8.5.9.
C
ONNECTING
AA-516R
MODULES IN CASCADE STARTING FROM A
AA-516R
POWERED MODULE
...37
9.
PARAMETERS
PROGRAMMING
AND
COMMANDS.............................................................38
9.1.
P
ARAMETERS PROGRAMMING
....................................................................................................38
9.2.
R
ESET PARAMETERS TO FACTORY DEFAULTS
...............................................................................39
9.3.
F
IRMWARE VERSION INSTALLED ON THE DEVICE
............................................................................39
9.4.
P
ARAMETERS TABLE
................................................................................................................40
9.5.
S
TANDARD GREETING MESSAGES
..............................................................................................45
9.6.
S
PECIAL COMMANDS
................................................................................................................49
9.7.
E
XAMPLES OF PROGRAMMING
/
O
PERATOR COMMANDS
.................................................................50
9.8.
I
NFORMATIONS FOR THE WALL INSTALLATION OF THE SYSTEMS
.......................................................51

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 5 of 56
1. OVERVIEW
The AA-514 family of Doorphone is designed to manage a passage through an analog FXO extension line of the
PBX and optionally provides a wired analog video connection on a monitor available to the operator.
When a visitor presses a button, the unit will call a programmed extension of the PBX. The person who answers
the call can speak to the caller and can open the door by sending a DTMF command
If equipped with the camera, the images of the area framed by AA-514 will be screened on the monitor placed near
the operator.
AA-514C AA-516P AA-516K AA-516R
The units are equipped with two relays to control the door opener. The commands can be given to the unit via
DTMF tones, such as activate the second relay, set the operation mode or to program the parameters of AA- 514.
The doorphone can be called directly from an extension to activate the opening of the controlled gate even without
the request for access from an outside visitor or to be programmed.
The base system in version with electromechanical relays is the model AA-514.
The base system in version with electromechanical relays and amplified audio is the model AA-514A.
The base system in version with solid state relays is the model AA-514H.
The base system in version with solid state relays and amplified audio is the model AA-514HA.
The systems listed above are available with built-in analog color camera in the versions AA-514xC.
The base system is available with 4 buttons. There is an expansion module AA-516P to add 8 additional buttons to
the base system and an index window zone, to get up to a maximum of 12 call buttons. As an alternative to the AA-
516P module, it is also possible to add to the base system the AA-516K module with full numerical keyboard and
an index window zone, to expand the services offered by the system and give way to the visitor to directly dial the
numbers.
Among the expansions is also available the AA-516R module, which is useful in conjunction with the keypad, with
two wide backlit surface to be used to present to the visitor a complete legend of numbers to dial. AA-516R can
also be used to provide more general informations such as the civic number etc. These modules can be added at
will, depending on the amount of information to be presented to the visitor.
Completing the series of systems: wall frames, rain shields, external wall boxes and a power supply.
AA-39 AA-517-C1 AA-517-T1 AA-517-S1 . . .

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 6 of 56
2. MAIN FEATURES
AA-514 main features are:
•Outdoor doorphone with FXO port, for PBX internal extension analog line
•Self-powered from the telephone line only for notice service and conversation, AA-514 model
•Self-powered from the telephone line for notice service, conversation and door opener, AA-514H model
•Operating modes DAY / NIGHT or GROUP (different handling of calls)
•Phone call generation in front of the pressing of a button on the device
•Possibility of courtesy message in two languages to the visitor for forwarded call notify
•Hands-free high quality audio talking with visitor in half duplex
•Service of voice announcements for small environments such as warehouses or other
•Programmable talking time with the possibility to extend the normal talking time
•Possibility of environment noise reduction during the conversation
•Possibility of acoustic signals for each operation performed by the system
•DTMF multifrequency tones selection on the telephone line
•Ability to enable DTMF post selection during a call (with keyboard module)
•Command code to hang up the call immediately (may be combined with the opening command)
•Auto disconnection (hang up) upon receipt of the reorder tone
•Possibility to detect silence during a conversation with a consequent hang up of the call
•Two door opener relays to drive two different electric locks, for example to make the distinction between
gate and pedestrian entrance
•Door opener relay activation directly from the called phone through DTMF tones
•Different ways of activating the built-in relays, door opener or button repeater for extra door bell,
automatically delayed opening of the relay 2 eg. marker lights for pedestrian and other, possibility to
backlight the system automatically in Night using the relay 2, and more
•Possibility to power AA-514, the load of the relay 1, the load of relay 2 with 3 different power sources
•Possibility to power the expansion modules in cascade
•Circuit of internal anti-humidity heating to increase reliability and durability
•Up to 3 programmable access codes for each relay to allow to access to the company directly from the
doorphone without the intervention of the operator (eg useful to service personnel or external assistance,
which for work reasons frequently comes out and return back in company)
•Up to 200 programmable access codes to allow to access to the company directly from the doorphone
without the intervention of the operator (option available only with the keypad module)
•Pleasant and reliable LED backlighting of the buttons and of the label holder
•System parameters programming by a phone call to AA-514 with DTMF commands
•Programmable ringer volume (for calls to the doorphone)
•Screws front with a special vandal proof fingerprint
•Device assembly and assistance facilitated by the use of practical insertion-type terminals
•Terminals with a large entrance area for the possible use of cables up to 1.5mm
2
or AWG16
Other features dependent on the various versions of the base system:
•Model AA-514 with electromechanical relays (maximum load 30V 2A)
•Model AA-514H with solid state relays (maximum load 30V 2A)
•Model AA-514A with amplified audio section and electromechanical relays (maximum load 30V 2A)
•Model AA-514HA with amplified audio section and solid state relays (maximum load 30V 2A)
Other features dependent on the various versions of the base system with camera, camera models are AA-514C,
AA-514HC, AA-514AC, AA-514HAC:
•Models with outodoor analog color camera and integrated LED illuminator.
•Wide angle view field, 140°of framing view field.
•Mode of operation of the built-in camera: off, always on, active during the call.
•Operating mode of LED lighting camera: off , always on, active during the call.
•SOFT-ON lighting function (progressive power) of internal LEDs for forced lighting of the frontal area of the
camera in order to not be unpleasant for visitors
•Ability to enabled the camera according to the number dialed by the visitors
•Ability to enabled the camera after entering DTMF code
Other features dependent on additional options of the system:
•Expansion up to 12 buttons using the module that adds 8 buttons and a legend, AA-516P
•Expansion with full numerical keyboard and a legend using the AA-516K module
•Expansion with additional modules for the display of numbers to call, the street number or other
informations, by one or more dual legend AA-516R modules.

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 7 of 56
3. PARTS COMPRISING THE SYSTEM (PACKING LIST)
The AA-514 system consists of the parts included in the following list:
•An AA-514 device (external unit with 4 buttons)
•A special key for the front panel screws
•Two plastic sliding tabs for frontal screws protection
•A set of die cut labels with extractor for label holders
•A CD-ROM with documentation and technical manual
The AA-514C system consists of the parts included in the following list:
•An AA-514C device (external unit with 4 buttons + camera)
•A special key for the front panel screws
•Two plastic sliding tabs for frontal screws protection
•A set of die cut labels with extractor for label holders
•A CD-ROM with documentation and technical manual
•Adapter for connecting the output video a over twisted pair
•Two balun adapters to carry video signal over UTP cable twisted pair
The AA-516P expansion consists of the parts included in the following list:
•An AA-516P module (8 push buttons)
•Cable for connection to the base unit AA-514
•A special key for the front panel screws
•Two plastic sliding tabs for frontal screws protection
•A set of die cut labels with extractor for label holders
The AA-516K expansion consists of the parts included in the following list:
•An AA-516K module (full numeric keypad)
•Cable for connection to the base unit AA-514
•A special key for the front panel screws
•Two plastic sliding tabs for frontal screws protection
The AA-516R expansion consists of the parts included in the following list:
•An AA-516R module (Legend)
•A special key for the front panel screws
•Two plastic sliding tabs for frontal screws protection
•One die cut label for the index legend (already inserted in the system)
It is possible to add also the following accessories:
Frames for wall covering
for one, two or three devices respectively
AA-517-C1, AA-517-C2, AA-517-C3
Frames for wall covering and flush box
for one, two or three devices respectively
AA-517-T1, AA-517-T2, AA-517-T3
Complete box for external wall mounting with
rain shield for one, two or three devices respectively
AA-517-S1, AA-517-S2, AA-517-S3
Power supply adapter AA-39AL

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 8 of 56
3.1. Cross-reference table of features / services of the various models
The following table shows for each system the main features that characterize it and the required needed
configuration:
AA-514 AA-514A AA-514H AA-514HA
Amplified Audio
-- Yes (▲) -- Yes (▲)
Doorphone and
conversation
Yes Yes (▲) Si Yes (▲)
Relay drive
EM (▲) EM (▲)SS SS
Fixed Backlight
Automatic Backlight
Yes (▲)
Yes (▲) Yes (▲)
Yes (▲) Yes (▲)
-- Yes (▲)
--
Anti
-
condensation
(internal heating)
Yes (▲) Yes (▲) Yes (▲) Yes (▲)
▲= AA-39AL power supply required, EM= electromechanical, SS= solid state, cells with gray
background indicate the services obtained with AA-514 powered only by the telephone line
The following table shows for each system with camera the main features that characterize it and the
required needed configuration:
AA-514C AA-514AC AA-514HC AA-514HAC
Amplified Audio
-- Yes (▲) -- Yes (▲)
Doorphone and
conversation
Yes Yes (▲) Yes Yes (▲)
Relay drive
EM (▲) EM (▲)SS SS
Fixed Backlight
Automatic Backlight
Yes (▲)
Yes (▲) Yes (▲)
Yes (▲) Yes (▲)
-- Yes (▲)
--
Anti
-
condensation
(internal heating)
Yes (▲) Yes (▲) Yes (▲) Yes (▲)
Camera support
Yes (▲) Yes (▲) Yes (▲) Yes (▲)
SOFT
-
ON front camera
area lighting
Yes (▲) Yes (▲) Yes (▲) Yes (▲)
▲= AA-39AL power supply required, EM= electromechanical, SS= solid state, cells with gray
background indicate the services obtained with AA-514C powered only by the telephone line
At any base model AA-514, it is possible to add one expansion module chosen between the two models AA-
516P and AA-516K while it is possible to add more AA-516R modules.
The keyboard module is available in three versions, AA-516KA with plastic keyboard, AA-516KB with metal
keyboard and AA-516KC with metal backlighted keyboard.

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 9 of 56
The expansions AA-516P or AA-516K are connected and powered directly from the base unit via a supplied
cable, expanding the functions of the base system:
Expansion
AA-516P
Expansion AA-516KA
Expansion AA-516KB
Expansion AA-516KC
Expansion
AA-516R
Numbers of buttons
8 -- --
Telephone Keypad
-- Yes --
Door opening codes
Yes Yes --
Button matching to the
phone number
Yes Yes (keys from 1 to 9) --
Direct number dialing
-- Yes --
Speed dial
-- Yes --
Possibility of filter/prefix
digits
-- Yes --
Backlighting
Yes Yes legend, keyboard only AA-516KC Yes
Label holder
Yes, buttons -- Yes, front area
Ad
ditional front area
for informations with
backlight
Yes Yes Yes
+

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 10 of 56
4. TECHNICAL SPECIFICATIONS
Base Systems Power Supply
Conditions: system in conversation, audio presence
on the loudspeaker and two relays activated
12V
AC
voltage with power consumptio
n:
AA-514, AA-514H stand-by 10 - max. 150 mA
AC
AA-514A, AA-514HA stand-by 10 - max. 750 mA
AC
AA-514C, AA-514HC stand-by 30 – talk. max. 500 mA
AC
AA-514AC, AA-514HAC stand-by 30 – talk. max. 500 mA
AC
AA-514 backlight circuit max. 070 mA
AC
AA-514 anti-condensation circuit max. 310 mA
AC
Active camera power consumption max. 200 mA
AC
Camera lighting max. 300 mA
AC
Power Supply of additional systems
Powered from the base system using the supplied cable:
AA-516P backlight circuit max. 250 mA
AC
AA-516P anti-condensation circuit max. 310 mA
AC
AA-516K backlight circuit max. 250 mA
AC
AA-516K anti-condensation circuit max. 310 mA
AC
AA-516R backlight circuit max. 250 mA
AC
AA-516R anti-condensation circuit max. 310 mA
AC
Number of built
-
in relays in
AA
-
514
2
Max relay contacts load
30V
–
2A
Minimum working voltage of solid state
relay circuits
12V
Difference of potential between 3 power
sources that can be connected to AA-514
(system - relay 1 - relay2)
1500V
Insertion type terminals for relays a
nd
other
Possibility to use cables up to 1.5mm
2
or AWG16
Material of the container
Corrosion
-
resistant aluminium 9006/1
-
T6 (6060
-
T6)
Buttons body in Mackrolon® Polycarbonate (UL94-V2)
ABS Novodur® heads
Mounting type
Flush mounting, wall mounting with ac
cessory AA
-
517
-
S
IP grade of protection
IP54
Operating Temperature
From
-
20
˚C to +50˚C
Relative humidity
95% not
-
condensing
Systems dimensions and weight
AA
-
514
L 123 x H 216 x D 16 (+45) mm
-
525 g
AA-514C L 123 x H 216 x D 16 (+45) mm - 600 g
AA-516P L 123 x H216 x D 16 (+45) mm - 525 g
AA-516K L 123 x H216 x D 16 (+45) mm - 525 g
AA-516R L 123 x H 216 x D 16 (+45) mm - 525 g
(dimensions of the flush part into the wall)
Accessories for mounting and security of the systems
Dimension
s and weight
AA
-
517
-
C1
L 138 x H 230 x D 2 mm
-
070 g
AA
-
517
-
C2
L 262 x H 230 x D 2 mm
-
125 g
AA
-
517
-
C3
L 386 x H 230 x D 2 mm
-
175 g
AA
-
517
-
T1
L 143 x H 232 x D 43 mm
-
240 g
AA
-
517
-
T2
L 267 x H 232 x D 43 mm
-
330 g
AA
-
517
-
T3
L
391 x H 232 x D 43 mm
-
470 g
AA
-
517
-
S1
L 143 x H 232 x D 90 mm
-
0740 g
AA
-
517
-
S2
L 267 x H 232 x D 90 mm
-
1250 g
AA
-
517
-
S3
L 391 x H 232 x D 90 mm
-
1740 g

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 11 of 56
Camera section (only for AA
-
514C systems)
Sensor
C
-
MOS color ¼”
Resolutio
n
420 TV lines
System
PAL
Sensitivity
1 Lux
Viewing angle
Wide
ang
le 14
0°
Gain adjustment
Automatic
White balance
Automatic
Video output
Composite video 1Vp
-
p 75
Ω
Connector
RCA female
Camera grade of protection
IP67
Telephone section
Current when line is released
< 250
µ
A
Line Impedance
8000
Ω
@ 1KHz
Audio bandwidth
300
-
3400Hz
Impedance during RING
> 40000
Ω
@ 200..4300Hz, > 5000
Ω
@12..16KHz
RING sensibili
ty
10Vrms @ 25/50Hz
Line voltage / current characteristic
8Vdc @ 20mA
Minimum operating current
line 24Vdc
7.5Vdc @ 15mA @ Line imp. 1200
Ω
line 48Vdc 7.6Vdc @ 18mA @ Line imp. 1200Ω
Impedance with taken line
According to ETSI ES 203 021
Return loss
Ac
cording to ETSI ES 203 021, less than
-
15dBV
Dialing DTMF level
First group
-
9dBV, second group
-
11dBV (+/
-
2dBV)
DTMF RX sensibility
Better than
-
30dBV
Dialing tones sensibility
Better than
-
30dBV

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 12 of 56
5. OPERATION
When, in standby condition, someone press one of the call buttons on the AA-514 base system or on the AA-516P
expansion or is dialed a number on the AA-516K numeric keypad, the doorphone automatically generates a
telephone call through the connected internal extension of the PBX.
In systems equipped with video camera, this is activated at the beginning of the call and the images made available
on the connected monitor, until the end of the conversation. There are other operating modes available, such as to
keep it always on or off.
The visitor begins to listen from the louspeaker of AA-514 the result of his access request whether or not
accompanied by a voice message. The visitor will then hear the first ringing control tone, then the reply from the
operator who was called by AA-514.
The operator who answered may then decide to activate the electric lock directly typing the correct sequence of
programmed DTMF digits (door opener code). After the opening pulse, the audio connection can be automatically
closed or the operator himself can type on the keyboard of his phone the hang up code or simply hang up (AA-514
will detect the reorder tone). In addition, a programmable conversation time-out provides to limit the maximum
duration of the call. When there are less than 30 seconds before the expiry of timeout, AA-514 will play a warning
tone. It is possible to extend the duration of the call by typing the recharge time code.
It is also possible for the operator or other extensions, to reach the telephone number where AA-514 is connected
for example to make a programming, to change the operating mode or to directly activate the two integrated relays.
It is possible, within certain limits, to adjust the loudspeaker output level and the microphone sensitivity of AA-514
in order to better adapt to the acoustic characteristics of the area or environment where it is installed. It may be the
case that when AA-514 is installed in particular area or gates, the audio conditions are particularly "difficult" and
you hear the typical Larsen effect due to feedback during the conversation. The characteristics and the
loudspeaker level and microphone adjustments of AA-514 are made at the factory and normally allows to
overcome these situations without having to take other special precautions. Finally, there is the possibility to enable
the noise reduction to improve the calls audio quality.
AA-514 allows to manage the two built-in electromechanical relays in two different modes, active with normally
closed contact and active with normally open contact. In the first case , when the operator gives the activation
command, the relay is activated while in the second case, the exchange of the relay (normally activated) is
deactivated at the reception of the command.
AA-514 and its expansion modules AA-516P, AA-516K, AA-516R have the possibility to activate an internal heating
circuit that can be inserted via an internal jumper. AA-514 and its expansion modules also have the possibility to
activate the label holder backlighting or keyboard backlighting in a fixed way or in some cases also automatically
when switching between Day and Night mode. The backlight is activated permanently via an internal jumper and
automatically through the built-in second relay (by connecting power supply and contacts).
5.1. Buttons and numeric keypad expansions
Adding the AA-516P expansion, it is possible to have 8 extra buttons, to get up to 12 call buttons in total. Adding
instead the AA-516K expansion it is possible to have the telephone keypad that allows some additional services.
There is for example the possibility for the visitor to directly call a phone number, or to call the numbers
(appropriately pre-programmed in the parameters) of the Speed Dial operating.
See for example the case of a possible visitor who goes to the entrance of a building site and among the dozens of
companies on the job site must conctat one in particular: just provide a legend in the proximity of the device that
has the instructions and the various numbers to call to get in touch with the person of each company.
The same operation mode may be applicable in public facilities, large buildings and other environments. The calls
(if allowed by the appropriate class of service of the extension number assigned to AA-514 on the PBX) can also
be made to mobile phones or trunks and not only just to the extensions of PBX to which it is connected.

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 13 of 56
It is also possible to compose only the final part of the number using the operation mode with a root number. In this
case the system prepends to the dialed number on the keypad a pre-programmed prefix. For example, if the root
number is "3" and the user types on the keyboard "14", the system will associate the prefix and dial the number
"314". This service is also found useful to mask the true extension number of the person to contact.
In addition, this field or service may be used to avoid to make calls directly from the system, when equipped with a
AA-516K keypad, engaging the external lines of the connected PBX. In fact, if a visitor will try to dial 02123456, the
system will call 302-123456 preventing the external call.
The direct dialing mode is NOT an alternative to the speed dialing mode and can both work.
Below is shown the position of the buttons with their logic mapping on the systems.
AA-514 AA-516P
3
1
2
4
5
7
6
9
8
10
11
12

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 14 of 56
6. OPERATING MODES
The system has the label holders combined with the buttons. When a visitor presses one of the buttons, the system
make a call on a PBX extension associated with the pressed button.
The call will be made with the delay set by parameter 128 (refer to the table of the programming parameters on the
following pages) when the button is pressed the first of a possible “code sequence" (see below in "RELAYS control
with access codes") to which must be added the delay set in parameter 130 .
The numbers that are called may differ depending on the operating mode in which the system is programmed, Day
- Night mode / Group mode, set by parameter 118.
If the system AA-514 is equipped with the 8 buttons expansion the operation described below for the 4 buttons on
the base system remains valid and is extended to additional buttons (parameters 200-207 for the Day mode and
210-217 for the Night mode).
In the case of keyboard expansion, are valid the same informations as stated for the buttons on the base system
while the keyboard allows to dial the desired number, or to handle additional functions described later.
When is used the keyboard in Speed Dial mode, described below, the descriptions of the operating modes listed
below are valid only for the numbers associated with the Speed Dial service.
6.1. DAY / NIGHT Mode
In the Day mode will be called the number associated with the corresponding pressed button (associated in the
parameters 110-111-112-113). In Night mode will be called the number associated with the corresponding pressed
button (parameters 114-115-116-117). At the press of the button the system makes the call only once irrespective
of the result. The visitor hears signalings of ongoing call preceded by a voice message, when enabled.
If the visitor presses a button again while the call is in progress, the system stops the call and returns to standby
mode. In systems with the keyboard expansion, to stop the call, it is necessary to press the star key (*).
To put the system in Day mode, the operator must submit to the system the command entered in parameter 121.
To activate the Night mode, the operator must send the command entered in parameter 122. The system reply
playing two beeps to confirm the activation of the Day mode and five confirmation beeps for the Night mode.
It should be noted here that following a reset of the internal parameters of the system, the system restores the Day
mode. The preparation of the active mode is stored in the system also when system is powered off and then when
it reactivate itself, previous active mode will be restored (if the phone line is disconnected and then reconnected for
example).

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 15 of 56
6.2. DAY / NIGHT mode with call repetition to the same number
To activate this mode should be set up properly its parameter (parameter 118). The operation is similar to that of
the above described mode with in addition the possibility to perform a cycle of call attempts in order to increase the
possibilities of handling the call with a positive outcome. The call is considered successful when the operator dials
the code specified in parameter 123. In all other cases (busy, free, no answer, answer without send the code...) the
system waits for the time specified in parameter 155 after that make a new call attempt to the same number until
the end of the number of call attempts set in parameter 151.
Pressing another button during the call cycle has no effect. The visitor will not be able to listen to the call attempts
until the operator has not entered the code to enable communication.
The operator that receive the call will hear the system tones as a call alert by the visitor. The system returns to
standby at the end of the notice cycles or when the operator (after he has entered the correct code) closes the
conversation with the visitor.
6.3. GROUP Mode, cyclic calls
To activate this mode should be set up properly its parameter (parameter 118).
For each button it is possible to associate two contact numbers, normally used in the Day / Night mode described
above. When the system is instead set to operate in the Group mode, the pressure of a button causes the system
to begin a cycle of calls to both numbers associated with each individual button and a third number common to all
the buttons defined in the parameter 220.
The cycle is interrupted only when the operator that receive the call type the correct code set in parameter 123.
This mode is similar as the Day / Night mode with calls repeat with the difference that each cycle of calls is carried
out on three different numbers.
If the system is in Day mode will be first called the number in the parameter associated with the Day mode button,
then Night and then the third number. If the system is in Night mode will be first called the number associated with
the Night mode button, then Day and then the third number.
This operating mode is particularly useful when you want to get the best chance to contact one of the operators by
the visitor (temporary job sites, other).
6.4. Additional features of the keypad expansion
If the expansion module AA-516K is installed, the visitor can make a call simply by dialing the desired number if
known by him or presented into an index table placed near the doorphone (eg the AA-516R expansion), typing it
directly on the keyboard.
The introduced number to dial is considered finished after about two seconds after the last dialed digit by the
visitor. It is possible to speed up the dialing without waiting for the system timeout by pressing the pound key (#) at
the end of the number, in which case the call is made immediately.
The visitor, realizing that has made mistakes in typing can be immediately cancel the entered digits by pressing the
star key (*), the same key has the function to break down if the call is already in progress.
In addition to direct dialing mode, the keypad allows for Speed Dial function, in which it is possible to associate a
number to call to each digit of the keyboard (10 phone numbers associated with the digits from 0 to 9), this service
can be enabled via the parameter 149. The numbers are 20 in total as 10 are associated with the digits in the Day
mode and the other 10 can be associated with the same digits in the Night mode.
According to the system mode, the visitor can then contact one of the 20 numbers entered. The Speed Dial mode
is NOT exclusive but coexist with the possibility of direct dialing with the only exception that it is not possible to
directly dial single digit numbers. Having to select the visitor directly to a single-digit numbers it is not possible to
use the Speed Dial service.
The Speed Dial feature (single digit of the keyboard) behaves as pressing a button on the base system and it is
also adjusted according to the parameter 118 about the operation in Day/Night mode, Day/Night with repeating
calls, or Group mode. In practice, for the user the keyboard also add 10 more call buttons.
By directly dialing the number to call on the keyboard, may be possible for the visitor to dial a number that you do
not want to be dialed, or at least reached (eg outside the company). To avoid this possibility, use the parameter

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 16 of 56
150. This is a code that, if programmed, provides to prepend a number to the dialed number. If the numbers of
operators are in the numbering plan of the PBX (internal extensions), it is sufficient to program the parameter 150
with the first digit of the numbering plan and expose the legend for visitors with numbers to reach without the first
digit. For example, to call the operator at the extension number 311 it must be programmed the parameter 150 with
a value of 3 and indicate to the caller to dial the number 11.
In the case there is the need that the the visitor must dial external numbers, this parameter may be useful if filled
with the value of a code that instructs the PBX to use a specific trunk group for outgoing governed by the desired
class of service, with restrictions on certain numbers for calls when the PBX allows it (long distance calls, foreign
calls, fee-based services, mobile network, etc.).
In other cases, remember to activate some kind of control on the possible numbers that a general visitor can dial,
to prevent unauthorized calls.
AA-514 is equipped with a special table of up to 10 numbers that allows to create a filter on the selections made by
the user, in order to allow or reject it, even without the control of the PBX. This table and this service are very
useful for systems equipped with the full keyboard expansion module. See the parameters from 230 to 240 for the
programming of these particular functions.
There is a special code (stored in parameter 178) that allow, during a call, to enable the keyboard to emitt DTMF
tones, like a analog phone. This function is usefull when you reach telephone systems that interact with the user
and must be controlled with DTMF tones.
6.5. 800 Numbers feature
Starting from the 2.8 firmware version, the 'Speed Dial' function of AA-514 systems was expanded, bringing the
total of the numbers associated with Speed Dial from 10 to 800. It is important that the optional AA-516K (numeric
keypad) is present and that the function 'Super Speed Dial' is enabled. The Speed Dial numbers to type on the AA-
516K keyboard have a range from 000 to 799 (for a total of 800 numbers) and each of them can be associated with
a number that AA-514 will dial, the maximum lenght of the numbers to dial is 15 digits. Enabling this new function, it
is NOT possible to use the Day/Night/Cycling operating modes of AA-514; the Doorphone will be in fact always
considered exclusively set up in Day mode, regardless of the related programmed parameters.
The audio messages playable from AA-514 last up to 7 seconds each, for a total of 14 seconds, compared to 16
seconds of the previous versions.
Enabling the new feature, the direct selection by AA-516K numeric keypad will remain unchanged. The system will
check the number of entered digits; if it is less than or equal to 3, it will activate the new service, otherwise the
entered digits will be normally composed. If it is needed to call directly a 3 digits internal extension, it is necessary
to insert them in the corresponding memory table. Using the 'Super Speed Dial' service, it is not possible to directly
call the internal extension between 800-999. Usually, 'Super Speed Dial' service is used in residences/villages
realities with a great number of contacts and it is not necessary to directly call other internal extensions.
Similarly, the AA-514 call buttons function remains unchanged, the only limitation is that they will work only in Day
mode, regardless of how AA-514 is set. To enable this service, the parameter 149 and the parameters from 1000
to 1799 must be correctly set, please see the parameter table.
6.6. RELAYS control with access codes
The opening function of the door opener connected to the two relays can be made available to a visitor who is
familiar with the various preset access codes.
The code is made up by the alternating pressure of the buttons of the device: for example, the code "121212" on
the system AA-514 correspond to press the first and the second button in sequence three times. It is possible to set
up to three access codes for each relay, one common always active if set, one vaild only in Day mode and another
one for Night mode only.
The parameters to set are 124-125-126 for the relay 1, and 164-165-166 for the relay 2. The time between the
pressing of a button and the other one for code entering must not exceed the value set in parameter 128. Upon
detection of the code correctly inserted, the corresponding relay will be activated for the time set in parameter 137
or 142.
The opening codes for the system based on 4 buttons will obviously consist of combinations of single digits from 1
to 4. If the system is equipped with the AA-516P expansion with 8 additional buttons it is actually possible to use all
the digits excepts zero (1-9).

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 17 of 56
If the system uses the AA-516K expansion, the opening codes must be typed directly on the keyboard preceded by
the star key (*) to distinguish them from a normal telephone call. The visitor will get access without operator
intervention (for example, useful to service personnel or external assistance, which for work reasons comes out
and returns back frequently in the company).
It is possible to set in the parameter 151 the maximum number of attempts of code introduction to open the door in
a way that, when the maximum number set is exceeded, the system make an alert call to the number set in the
parameter 152. This is an useful service to alert people inside the company of an unauthorized attempt to access
or to report difficulty to access by a visitor. The alert is made with a series of calls according to the value set in the
parameter 151.
6.7. 200 additional access codes Special Function
Starting from the 2.8 firmware version, are added 200 more access codes that allow to activate the integrated
relays. The new additional codes can be inserted only by the expansion numeric keypad AA-516K and follow the
same rules of the 3 base access codes. The codes must be preceded by the star key (*). For each additional code,
it is possible to associate the activation of the relay 1, the relay 2 or both. The codes will activate the associated
relay regardless of the AA-514 day/night mode set. To enable this service, it is necessary to program the proper
parameters (from 3000 to 3199); please refer to the parameter table for the correct values.
6.8. Calls generated by AA-514
These are the calls that the system generates on the line, triggered by the pressure of the button by a visitor by the
previously described ways.
Who answers the call can speak to the caller for a fixed time set in the parameter 101. If the conversation goes on,
warning tones will be played in the phone so that the operator can enter the code set in the parameter 127 to
extend the call duration.
Also during the conversation, the operator can enter a code to open the door (parameter 120/141). The parameter
119 contains the code to close the call. If it contains the same code of the parameter 120, the door will be opened
and the doorphone immediately release the line for the next possible visitor. If the parameter 120 contains a
different value than parameter 119, once the door is opened, the talking will remain active until the timeout expires
or, if the operator hangs up, the system returns to standby after a few moments detecting the reorder tone.
It is also possible to enable the system to hang up and go back to standby if it detects silence that lasts during the
conversation. To enable this feature the parameter 161 must be set to 1 and must be defined in the parameter 162
for how long the silence lasts in the call; when the system “hear” the silence, it behaves as viewing a reorder tone,
hangs up and returns to standby.

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 18 of 56
6.9. Calls to AA-514
Call the system AA-514 from the PBX phones is useful to activate the conversation or issue commands for
example when a visitor is detected near the doorphone, through a video surveillance system of the gate, or if some
vehicle arrived at the entrance driveway or as announcer to serve certain areas of warehouses without using a
more complex system of public address audio diffusion (i.e. using the amplified unit AA-514A).
Calling the extension number connected to the AA-514 system, it will answer after the number of rings specified by
the parameter 136. In conversation the caller has the same commands described above for incoming calls to
trigger the door opening and other controls such as the programming, the change of the operating mode, and
more.
It is possible to set the reply of the system by pressing a button or typing a code to be carried out directly on the
doorphone. This service, governed by the parameters 158 and 159, allows to avoid an undesired conversation in
the absence of the specific intended operator in his working place.
It is also possible to force the direction of the conversation (audio delivered to the doorphone / audio received from
the doorphone) following by the reply of AA-514. These functions, governed by the parameter 158, allows to
generate services of monitoring from/to the doorphone. Please note that in all cases the functions of time-
out/reorder tone/silence disconnection are enabled and also the DTMF commands that the operator can normally
send to AA-514. When the system is set up in this way, it is in fact not possible to establish a bi-directional
conversation.
6.10. Additional features of the built-in camera and the dedicated front lighting
The systems equipped with built-in analog color camera can send pictures of the framed area to a monitor usually
located at the operator that controls the passage. The images integrate the normal telephone call. When the
conversation is established, the camera and its dedicated lighting will activate for the duration of the call.
Is it possible to maintain active the camera in a fixed way, not tying it to the conversation, allowing to continuously
watch videos of the framed area. The same service and in a distinct way can be obtained with the lighting function
dedicated to the camera.
The parameters that set this mode of operation are described in the programming table and are the fields from
number 171 to number 175.
It is also possibile to condition the activation of the camera to the composition of a particolar number by AA-514.
This number can be composed on additional keyboard or it can be associated to a button. It is possible to check
max 10 numbers, stored in parameters 241-250. The parameter 143 set this function ON or OFF.
It is finally possibile to force the activation of the camera entering a special DTMF code stored in parameter 177.
Whene the camera is set on in this way it remains active for the duration of the conversation.

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 19 of 56
7. COMMANDS AND CODES FOR THE INTERNAL OPERATOR
These are the main commands normally available when you are called by AA-514, the only ones that the operator
might need to know.
Upon receiving a call from AA-514, the communication will be activated and will be possible to send the commands
described here:
DTMF
Command
Function Description
#0 Close the call
Used to close the call forcing the unit to hang up. May
coincide or not with the opening code for relay 1 (parameter
120), defined in the parameter 119.
#1 Activate the door opener
contact of the relay 1
Used to activate the electric lock connected to
the first relay
during communication, it is a code from 1 to 4 digits, default
#1. Once the door was opened, AA-514 close immediately
the call if the code set in parameter 120 is the same with
the value set in parameter 119 (close call).
#2 Activate the door opener
contact of the relay 2
Used to activate the second relay during communication, it
is a code from 1 to 4 digits, default #2. Defined in
parameter 141. Warning: the function is also regulated by
the parameter 144 that should be set to 0 to allow the
operator for the function described here.
#3 Set the DAY mode
Sets AA
-
514 so that the pressure of the call button is dialed
the phone number associated with each button for the Day
mode. Defined in the parameter 121.
#4 Set the NIGHT mode
Sets AA
-
514
so that the pressure of the call button is dialed
the phone number associated with each button for the Night
mode. Defined in the parameter 122.
#5 Extension of talking time
It is possible to reload the original time to continue the call.
AA-514 will play some alert tones 30 seconds before
closing the call.
Normally it is always possible to call AA-514 from any PBX extension to talk with a visitor who stands in the device
proximity, to send other DTMF commands or to program it, by simply dialing the internal extension number to which
AA-514 is connected.

TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN Page 20 of 56
7.1. Signaling Led and AA-514 front panel description
Positioned above the speaker, AA-514 has a frontal signaling LED with two different modes of operation. In the
default mode, with the system in stand-by, the LED is off.
When receiving a call, the Led flashes according to the ring frequency, with the system in conversation the Led
follows the level of voice and also indicates the presence or absence of dialing tones.
In the default mode, with the system in stand-by, the Led is off. When receiving a call, the Led flashes according to
the ring frequency, with the system in conversation the Led follows the level of voice and also indicates the
presence or absence of dialing tones.
In the second mode of operation, that can be set using the parameter 156, when the system is busy, the Led lights
steadily and remains lit for the duration of the conversation.
Below are showed the parts on the system and their function. The model shown below is the model AA-514C with
the camera.
Signaling Led
Buttons Label Holders
Special closing screw protected by a plastic insert
( note: ** = only in the models with camera )
Loudspeaker
Microphone
Special closing screw protected by a plastic insert
Lighting Led **
Camera **
This manual suits for next models
7
Table of contents
Other Tema Telecomunicazioni Intercom System manuals