This booklet has been prepared to help you use the BB-16 blower.
The instructions for use and safety guidelines must be followed in order to prevent any accident.
Any disassembly or repair must be performed by TEMPEST or an approved dealer.
Reference product :
Reference
Product
910-1801 BB-16 110v Standard w/Battery No External Charger
910-1802 BB-16 110v Standard Plus w/Battery & External Charger
910-1803 BB-16 110v Delux w/2 Batteries & 1 External Charger
910-1811 BB-16 220v Standard w/1 Battery No External Charger
910-1812 BB-16 220v Standard Plus w/Battery & External Charger
910-1813BB-16 220v Delux w/2 Batteries & 1 External Charger

3
1 INTRODUCTION ............................................................................................................... 4
2 SAFETY INSTRUCTIONS ................................................................................................. 4
3 PRECAUTIONS ................................................................................................................. 5
4 GENERAL FEATURES ..................................................................................................... 6
5 PRESENTATION ............................................................................................................... 7
6 COMMISSIONING INSTRUCTIONS ................................................................................. 8
7 SETUP ............................................................................................................................... 8
8 USE ................................................................................................................................. 10
9 BATTERY ........................................................................................................................ 12
10 DESCRIPTION OF LED STATUS WHEN OPERATING ................................................. 15
11 IDENTIFICATION ............................................................................................................ 17
12 TROUBLESHOOTING .................................................................................................... 18
13 SPARE PARTS ............................................................................................................... 18
14 WARRANTY .................................................................................................................... 19

4
1 INTRODUCTION
BB-16 is a battery-powered self-contained fan. It is powered by batteries or AC power. Easy to
install; easily stored in the boot of a response vehicle and can be carried by one person. There are 1
version for each power supply:
BB-16
110V power supply
230V power supply
50-minute battery
The 110V version will not work on a 230V power supply.
The 230V version complies with EN50178.
The 110V version is compatible with US circuit breakers (GFCI).
2 SAFETY INSTRUCTIONS
§This equipment has been manufactured in accordance with CE directives. Its use is restricted to
firefighting professionals.
§Please read this manual in full as well as the instructions for use before commissioning and using the
equipment.
§Keep fingers and hands away from the impeller.
§Only qualified personnel should operate or repair this device.
§Do not use it if you can see any damage.
§Never move the fan when it is running.
§Non-ATEX electrical blower fan: the BB-16 should not be used in explosive atmospheres.
§Always replace parts with original spare parts provided by TEMPEST.
§Wear protective goggles, gloves and hearing protection when using the fan.
§Do not use wedges or other systems to increase the fan’s pitch.
§Do not wear clothes that are too loose which could be caught by the fan.
§The device should not be disassembled when switched on.
§The battery should only be replaced by an accredited professional (low power electrical accreditation) or
by TEMPEST.
§Never allow a person to use the device without having provided them with the necessary instructions.
§Do not clean with a high-pressure washer.
§The BB-16 has a lithium-ion battery.
§Lithium-ion batteries can be dangerous if not used and handled correctly. Improper use of your battery can
risk fire or explosion.

5
3 PRECAUTIONS
ØBefore use :
§Visually inspect the BB-16 and its accessories to check there is no damage.
§If there is an unusual noise or the turbine impeller gets jammed, stop immediately and inform TEMPEST.
§The instructions for use and safety guidelines must be followed in order to prevent any accident. Any
disassembly or repair must be performed by TEMPEST or an approved operator.
§This device has a Lithium battery , and therefore it does not need to be discharged before
recharging.
Note: The BB-16 battery is shipped at a state-of-charge under 30% in accordance with
regulations on Li-ion battery transport.
§Only use the battery for your BB-16 and not for other purposes.
§Do not try to open, cut, pierce or crush the battery.
§Ensure that the BB-16 is charged in an environment with a temperature between 0°C (32°F) and +40°C
(104°F) max.
Note: The BB-16 battery will not charge at temperatures below 0°C (32°F).
§For prolonged battery storage, we recommend that it is kept fully charged in a cool and dry location.
§Do not store the battery somewhere which is too hot (over 40°C (104°F))or too cold (-5°C) (41°F)
.
The ambient storage temperature should ideally be between 5°C (41°F) and 35°C (95°F).
Note: Do not leave the battery near excessive heat such as in a car in direct sunlight, or the battery’s features
and life span might be negatively affected.
§Use between -20°C (-4°F) and +55°C (131°F) on mains power.
-20°C (-4°F) to +55°C (131°F) on battery power (whilst respecting storage temperatures).
§The BB-16 equipped with its extraction duct (option) is designed for gas temperatures up to 60 °C (140°
F).
Note: Ensure that each person responsible for the device/using this device has read the user instructions and
safety guidelines relating to a rotating machine.

6
4 GENERAL FEATURES
vDimensions in storage position
vFeatures
BB-16
Weight
23.5 Kg +/-0.5kg (51.81 +/- ib 1.1 ib) With battery,
19.4 Kg +/-0.5kg (42.8 ib +/-1.1 ib) Without battery
Battery at full capacity
50 minutes
Battery
12.5 Ah
Recharge time
External charger :100% in 3h, 80% in 1h40, Internal charger : 7h30
Power
Single phase110v - 50/60Hz
Single phase 230v – 50/60Hz
Consumption in steady state
8 A
4 A
AC power supply
US Male pin socket
125V/15A
2P+Grounding (3Wires)
CE Male pin socket
230V/16A/50-60Hz
IP68 2 P + T
Free air delivery
On AC power supply 29270 m³/h (17215 CFM). With battery 29270 m³/h (17215 CFM)
VPP flow according to AMCA 240
18600 m³/h (10940 CFM).
Motor with speed controller
600 W
Sound level
76.8 db at 3m (9.85ft)
Air flow angle
+65° at -90°
Protection rating
IP66 (Totally protected against dust, protected against powerful water jets from all
angles)
Charger
Integrated
Propeller
Résine composite - ø 420mm (1.38ft)
Turbine protective casing and box
Two-layer polyethylene
Front grille
Composite material
Handling parts
Composite material

7
5 PRESENTATION
BB-16 is equipped with a lateral control console and benefits from Easy Pow ‘Air technology and a NEO
grille.
ØDescription :
ØAvailable options :
Designation
Reference
“Rehab” mister
I60.20.164
High-expansion foam adapter - BSP F ¾” input
I60.20.105
5m (16 4ft) blowing and suction spiral sheath
I63.20.025
50 m (164ft) 3G x 2.5 mm²extension cable in a bag with
lockable European sockets for 230V version
I60.00.016
BB-16 external charger EU plug
I63.12.301
BB-16 external charger US plug 585-035
BB-16 Battery 585-005
Rear grille
Propeller
Motor
Socket
(Depending on version)
Transport handle
Transport strap
Lithium battery
Fuse
8A / 110V Version
Or
4A / 230V Version
Lower box
Casing and NEO front grille
Transport handle
User instructions
Rotation with adjustable handle
Control console

8
6 COMMISSIONING INSTRUCTIONS
- On delivery, visually inspect BB-16 and its accessories to ensure there was
no damage during transport.
Do not try and use BB-16 if you notice any damage, contact TEMPEST
immediately.
A fuse is provided for surge protection (110V or 230V).
Ensure that each person responsible for the device/using this device has read the user instructions and safety
guidelines.
7 SETUP
ØThe BB-16 fan can be used indoors and outdoors.
ØUSAGE PRECAUTIONS

9
Note: the BB-16 fan is a high-speed air drive fan.
This portable fan is designed to remove smoke, volatile gas and other gas by blowing (or ventilation with
excess pressure) in all types of facility where there is an outlet. It can also be used for suction of cold
smoke (<60°C) (140°F).
Due to their design, BB-16 fans can be used at a distance from 0.5 to 6m (1.6 to 19.69ft) from an opening.
TEMPEST recommends a minimum smoke removal opening the same size as the window.
ØDescription of control console :
ØDescription of the battery level display:
ØDescription of charger indicators :
LED Battery level
indicator (and device
fault)
On/off button -speed button Speed set point LED
+speed button
TEST button
battery level
Battery level LED
Battery
LED turns from red to
green when the battery
is charged
Fixed mains power
presence LED
LED fixed charge
External charger

10
Mains supply
8 USE
BB-16 is self-contained, there is no need to provide a power cord up the stairs.
Always keep hands away from moving parts.
If the battery is low, use the mains power
1/ Charging the battery :
Due to transport regulations, the batteries are shipped and delivered at a state-of-charge under
30%. * This level is a TEMPEST pre-requisite.
On receipt of your BB-16, start by charging its battery.
See precautions for use.
Regardless of power source (mains, power generator...) ensure that there is sufficient power
which is stable in terms of voltage and current (rated +/- 10%) before connecting the device and
when charging.
The battery can be charged either inside the BB-16 or using the external fast charger (optional).
ðCharging in the device :
Place the battery pack in its compartment inside the BB-16.Connect the
plug to the mains power. (cf4.P7).
The device automatically starts to charge. LED status.
If there is a problem, refer to the alarms table.
ðCharging off device using the external fast charger (optional):
Connect the battery to the fast external charger
Note: If you are charging will start automatically once the battery temperature falls below 40 °C (104°F).
First, connect the charger to the battery, then connect the charger
to the mains power.
Make sure you follow this order: a different order could damage
the battery connector (not covered by the warranty).
When charging is complete, disconnect the charger from the mains
power, then disconnect the battery.
Ensure that the fan is switched off before
disconnecting the battery.
If not, disconnection when the fan is
operating might damage the battery
connector (not covered by the warranty).
External
charger
Battery

11
2/ Before starting the fan :
ðPosition BB-16 in a stable position and ensure there is no obstacle between the fan and ventilation
opening.
ðAdjust the angle between +65° and -90° using the adjustable adjusting handle.
3/ Starting the fan :
ðPress the On/Off button
ðAdjust to the desired speed from 0 to 100% by pressing the and buttons.
ðBy pressing and holding for 2 seconds, the speed changes to 100%
automatically.
LED status (cf10.P15).
4/ Regularly check during use that there is no obstacle impeding the air flow from entering the building, and
that nothing is obstructing the fan suction grille.
5/ Regularly check the battery charge level.
Adjustable handle

12
6/ Stopping the fan :
ðPress the On/off button
7/ Fuses :
Never remove the fuses when the device is connected or operating. Leader will not be held liable
for any damage due to inappropriate, incorrect or abnormal handling.
ØA glass fuse is provided for surge protection. To change the fuse, disconnect the BB-16, unscrew the
fuse holder cap.
9 BATTERY
The BB-16 is equipped with a Lithium battery
èBattery 12.5 Ah.
To prevent any risk of accident, TEMPEST equips its lithium-ion batteries with a BMS
(electronic protection system) which protects the battery from misuse: short circuit, overload, usage
temperature when charging and discharging.
All rechargeable batteries have a finite useful life and they may eventually need to be replaced.
The service life of your battery varies depending on how your device is used and the settings you choose.
110V Version
Type T 8A glass fuse
(5x20mm) (5x0.06ft)
230V Version
Type T 4A glass fuse
(5x20mm) (5x0.06ft)
Version 110V Version230V
Fuse holder

13
1/ Safety Instructions
ØRules to follow regarding the battery to avoid injury and material damage:
§Do not open the battery.
§Do not immerse the battery in liquid (IP67).
§Do not expose to high temperatures (no more than 70°C (158°F)).
§Do not use chargers other than the TEMPEST charger.
§Do not modify the battery for uses other than the intended purpose.
§Do not connect the +and -terminals with a conducting material.
§Do not transport or store the battery with metal objects.
§Avoid any impact on the battery, do not pierce or crush. There is also a risk that the protection circuit
would be damaged and the battery would have no protection.
§A pack damaged following an impact is potentially dangerous and could catch fire due to an internal
short-circuit. It should be monitored carefully as it can take several minutes to catch fire.
§If your battery experiences a severe impact, do not use it again. Take it to a local recycling centre for
disposal.
§Do not charge the battery near a source of heat. It might not charge if the protection circuit is
activated.
§Do not charge near to inflammable liquids or solids.
§Do not use a battery with visible signs of damage or distortion.
§Do not reverse the polarities (or contacts), as this might cause abnormal chemical reactions.
§No longer use or charge a battery if it has obvious anomalies, such as a particular odour, overheating,
distortion or discolouration.
§Stop charging if the charging process does not end.
§During transport: package the battery correctly in a box or case to avoid damage.
§Do not expose to strong oxidising agents.
§Wear appropriate PPE (gloves, goggles, etc.) during use.
§If the cell electrolytes come into contact with your skin, wash thoroughly with soap and water. If they
come into contact with your eyes, rinse thoroughly with cold water and contact a doctor immediately.
Note: If these instructions are not followed, the battery could catch fire...
1 / Safety precaution
§ Do not remove the battery when the BB-16 is in mains or battery operation.
Note: If the battery is discharged and the BB-16 is connected to the mains or in operation.
Then stop the fan, disconnect the mains plug and disconnect the battery if necessary.
§ Do not remove the battery from the charger when it is charging.

14
2/ Implementation
ØSwitch on the battery in the fan, it clips automatically. To remove it, simply press the retaining notch.
3/ Storage
ØAvoid any exposure to direct sunlight, high temperatures, or excessive humidity levels.
ØStore in a dry place, at temperatures between: 5 °C (41°F) at 35 °C (95°F).
Storing the battery at humidity and temperature levels below -20°C (-4°F) or above +35°C (95°F)
can permanently damage the battery: corrosion of metal parts, swelling, and leakage...
If you plan to store the battery for a long period, it is better to store your battery at a stable
temperature between +5°C (41°F) and +35°C (95°F) at 100% capacity.
A maintenance charge should take place once every 6 months to avoid deterioration.
§Avoid storing in electrostatically charged areas.
§Do not store together with electro-conductive material.
4/ Battery Treatment
Discarding batteries directly in the garbage greatly harms the environment. By replacing your
batteries from TEMPEST or an authorised distributor, you can be certain they will be recycled
according to environmental rules.
Do not throw batteries away just anywhere; limit any risk of pollution and avoid contaminating nature
with the traces of heavy metals still contained in certain types of batteries.
Batteries are collected and reprocessed; they contain certain recoverable heavy metals. Deposit them
in designated areas (recycling centres, collection points...).
TEMPEST joins RECYLUM for the recycling of its WEEE (Waste electrical and electronic
equipment).

15
5/ Features
§Batterie
Reference :
Model :
Voltage :
Power :
Weight :
585-005
3300001
48v
600Wh
3.800Kg(8.38ib) +/-0,1Kg(0.22ib)
§Charger
Reference :
Model :
INPUT :
OUTPUT :
Weight :
I63.12.301(EU) / 585-035(US)
YZP-450
100-240Vac 3.5a 50/60Hz 54.6v,
5.0A
0.8 Kg (1.76ib) +/-0,1Kg(0.22ib)
7/ Transport
Lithium Ion Batteries are considered dangerous products and are subject to
regulations. Contact your carrier before shipment.
10 Description of LED status when operating
ðBattery level LED status during AC power supply use (battery charging):
ðBattery level LED status during battery use :
0 à 20%
20 à 40%
40 à 60%
60 à 80%
80 à 100%
0%
375+/-1
82+/-1
146+/-1

16
ðSpeed setpoint LED status during battery and AC power supply use:
Note : Pressing the button will increase the LED speed setpoint.
Pressing the button will decrease the LED speed setpoint.
LEDs indicate the selected speed setpoint; you must wait a few seconds to reach the desire speed.
Alarms and warnings tables:
LED Flashing
Display
Meaning
BB-16 status
Solution
Driver fault
Does not work on battery or
mains power
Restart the fan
Battery temperature too high
during discharge (Over 55°C)
(Over 131°F)
Stops during use and does
not work on battery
Stop use, place the fan at room temperature
(20°C +/-5) (68°F +/-5) and restart 1 hour later
Possibility of using it on mains power
Battery temperature too low
during discharge
(Below -20°C) (Below -4°F)
Stops during use and does
not work on battery
Place the fan in a room above -20°C (-4°F) and
wait for the battery temperature to exceed
-20°C (-4°F)
Possibility of using it on mains power
Motor current consumption
too high
Stops during use and does
not work on battery or mains
power
Possibility to reduce speed
Check for obstructions or debris on the fan
suction grille and no obstacles impeding the air
flow
Supply voltage too high
Does not work on mains
power
Disconnect and reconnect the mains power
Supply voltage too low
Does not work on mains
power
Disconnect and reconnect the mains power
Speed configuration problem
On mains power the fan self-
configures to a non-
optimised speed/does not
work on battery
Contact TEMPEST.
Temperature too high during
charge (Over 40°C)
(Over 104°F)
The fan does not charge but
works on mains power
Disconnect the fan. Place the fan at room
temperature (20°C +/-5) (68°F +/-5) and
reconnect to restart charge 1 hour later
Vitesse 20%
Vitesse 40%
Vitesse 60%
Vitesse 80%
Vitesse 100%
Arrêt

17
*Note : Charging starts automatically when the charge conditions have been met: Charging temperature between
0°C and 35°C (32°F and 95°F) at the start of charging.
11 IDENTIFICATION
Display Meaning State of BB-16
Solution
Temperature too low during
charge (Below 0°C) (Below
32°F)
The fan does not charge but
works on mains power
Place the fan at room temperature (20°C +/-5)
(68°F +/-5)
Charge time too long
The fan does not charge but
works on mains power
Check LED battery level status and repeat
charge
Charge current too high
The fan does not charge but
works on mains power
Disconnect and reconnect the mains power
Charge current too low
The fan does not charge but
works on mains power
Check battery fuse, disconnect and reconnect
the mains power
Charge voltage too high
The fan does not charge but
works on mains power
Disconnect and reconnect the mains power
Battery temperature too high
to start charging (Over 40°C)
(Over 104°F)*
The fan does not charge but
works on mains power
Place the fan at room temperature (20°C +/-5)
(68°F +/-5), leave it connected (charging will
start automatically when the battery has reached
the desired temperature)
Battery temperature too low
to start charging (Below 0°C)
(Below 32°F)*
The fan does not charge but
works on mains power
Place the fan at room temperature (20°C +/-5)
(68°F +/-5) wait 1 hour and retry
Do not unplug
A battery temperature sensor
is out of service
Normal operation fault
display on power-up on
battery
Disconnect and reconnect the battery
Charge current measurement
out of service
The fan does not charge but
works on mains power
Disconnect and reconnect the mains power
Motor current measurement
out of service
Does not work on battery or
mains
Disconnect and reconnect the mains power
Year of manufacture
Place of manufacture
Reference
Designation
Serial Number

18
12 TROUBLESHOOTING
Problem
What to do
The fan does not work on battery
power
•Check that the battery is correctly engaged.
•Check that the battery is charged (control panel LED status).
•See LED status description (P17/18).
The fan does not work on mains
power
•Check the condition of the fuses (8A) for the 110V or (4A) for the 230V version.
•Check that there is a good power supply.
•See LED status description (P17/18).
•Vérifier que la grille avant n’est pas obstruée.
The battery will not charge
•Check the condition of the fuses (8A) for the 110V or (4A) for the 230V version.
•Check that the battery is correctly engaged.
•Check that there is a good power supply.
•Check that the room temperature is between 0 and 35°C (32°F and 95°F).
•See LED status description (P17/18).
Nota : If the fan speed is 100% the load is interrupted.
The fan stopped operating on
battery
•Check that the battery is charged (control panel LED status).
•If battery is low, use AC power.
•See LED status description (P17/18).
Nota : Over time and the charge cycles, the battery will lose its autonomy.
13 SPARE PARTS
To identify your BB-16 parts, please contact us.
response@tempest.us.com

19
14 WARRANTY
TEMPEST equipment benefits from a limited contractual warranty from the date of the purchase, 3 years
parts and labor (excluding shipping and travelling fees). Normal wear parts are excluded from this warranty.
The battery warranty is 1-year subject to compliance with user recommendations in the user guide
(One charge every 6 weeks).
This warranty is specifically limited to replacing or repairing the equipment (or its parts) which after
examination proves to be defective for causes attributable to TEMPEST.
To claim under a warranty, the user (with TEMPEST is approval) will need to return the equipment to
TEMPEST, 4708 N. Blythe Ave., Fresno, CA 93722 as soon as possible following the discovery of the
defect.
After reviewing the equipment:
-If the defect is attributable to TEMPEST, it will repair it and assume the costs (excluding shipping and
handling fees).
-If the defect is not attributable to TEMPEST, see the procedures explained below in the Out-of-
warranty defect paragraph.
This warranty does not commit TEMPEST in the following cases: failures resulting from improper
handling, improper use of the equipment, no maintenance or incorrect maintenance, incident affecting the
hardware, repair or modification by another company or non-authorized personnel.
OUT-OF-WARRANTY DEFECT OR EQUIPMENT NO LONGER COVERED BY THE
WARRANTY
A complete diagnostic will be conducted on your defective equipment, at the end of which a detailed estimate
will be sent to you for the necessary repairs.
For failures and repairs no longer covered by the warranty, a diagnostic flat rate will be applied regardless of
the acceptance of the repair quote.

20
Package leaflet code:
BB-16.EN.0
This manual suits for next models
6
Table of contents
Other Tempest Blower manuals

Tempest
Tempest VSG User manual

Tempest
Tempest VS1-18-BLDC User manual

Tempest
Tempest LAMINAR ELECTRIC - LE User manual

Tempest
Tempest BD-21-H-6.5 User manual

Tempest
Tempest VSM Series User manual

Tempest
Tempest POWER BLOWER User manual

Tempest
Tempest Power Blower Direct-Drive Series User manual

Tempest
Tempest Direct-Drive User manual

Tempest
Tempest SP Power Blower User manual