TeraBee IN5 User manual

Terabee Air Quality IN5
User manual
Document version: 1.1
Technical support: [email protected]
Sales and commercial support: [email protected]

Table of contents
1. Package contents 3
2. Intended purpose 3
3. Warnings 3
4. Technical specifications 4
5.Device description 5
5.1. Overview 5
5.2. LED 6
5.3. Button 6
5.4. Power plug 7
6.Quick device set up 7
7.Device behavior 9
7.1. Config state 10
7.2. Nominal state 10
7.3. Factory Reset state 11
7.4. LED behaviour 12
8. Web applications 12
8.1. Configuration Web app 12
8.2. Air Quality displaying web app 14
9. Troubleshooting 18
10. Cleaning instructions 18
11. Maintenance 19
12. Safety and Regulatory statement 19
12.1 Safety Instruction 19
12.2 EU Regulatory statements 22
12.3. UK Regulatory statements 26
12.4. US and Canada Regulatory statements 26
Copyright © Terabee 2022
Terabee, 90 rue Henri Fabre
01630 Saint-Genis-Pouilly, France (next to CERN)
Terabee Air Quality IN5 User manual
Version 1.1
2 / 26

1. Package contents
●Terabee Air Quality IN5 device x1
●Quick start guide x1
●Power supply x1
●USB type C cable x1
2. Intended purpose
Using our product will allow you to monitor indoor environments such as rooms and
buildings thanks to CO2, Total Volatile Organic Compounds Index (TVOC), Particulate
Matter (PM), temperature and relative humidity meters.
Please read and follow all instructions in this user manual. If you have any questions or
remarks regarding the product, please contact your commercial representative or our
technical support at [email protected].
3. Warnings
●CAUTION: To avoid the risk of electric shock.
●CAUTION: No modification of this equipment is allowed.
●CAUTION: Do not restrict the airflow of the product.
Copyright © Terabee 2022
Terabee, 90 rue Henri Fabre
01630 Saint-Genis-Pouilly, France (next to CERN)
Terabee Air Quality IN5 User manual
Version 1.1
3 / 26

●CAUTION: Not to be used by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction.
Children should be supervised to ensure: that they do not play with the
appliance.
●CAUTION: If the power cord is damaged in any way it must be replaced by a
special cord or assembly available from the manufacturer or its service agent.
●CAUTION: Terabee Air Quality IN5 not a water-resistant device; keep the device
away from water or any moisture.
●CAUTION: It is mandatory to use the AC/DC power adapter: ULLPOWER, modèle/
ICP06c-050-1000B, INPUT : 100-240V ~ 50/60Hz 0.3A, OUTPUT : 5.0V - 1.0A,
RATED POWER: 5.0W and the USB-C cable furnished by Terabee in this package.
If the device is used in a manner not specified by the manufacturer, the protection
provided by the device may be compromised.
4. Technical specifications
Connectivity
Data communication
Wi-Fi 802.11b/g/n
Local configuration
Wi-FI Access Point
Power supply
USB-C cable
Visual user interface
RGB LED
On board sensors
Particulate Matter (PM)
Sensirion SPS30 PM2.5 sensor - ug/m3
0-1000 μg/m³
Carbon dioxide (CO2)
Sensirion SCD41 Sensor - ppm
Accuracy: ±40 ppm
Measurement range: 400 - 5000 ppm
Total Volatile Organic Compounds
(TVOC)
Sensirion SGP40 - TVOC Index
Processed output: 0 - 500 TVOC Index
Measurement range (TVOC): 0 - 1000 ppm
Copyright © Terabee 2022
Terabee, 90 rue Henri Fabre
01630 Saint-Genis-Pouilly, France (next to CERN)
Terabee Air Quality IN5 User manual
Version 1.1
4 / 26

Air temperature and humidity
Sensirion SCD41 Sensor - ppm °C and % RH
Typ relative humidity accuracy: 6 % RH
Operating relative humidity range: 0 - 95 % RH
Typical temperature accuracy: 0.8°C
Operating temperature range: -10 to -60°C
Powering
Supply voltage VIN
5 V +/- 10%
Average consumption
(mains powered)
1 W
Enclosures
Dimensions
120 x 40 x 60 mm
Weight
110 g
Recommended ambient
temperature operation
0°C to 40°C
Recommended relative humidity
operations
10 - 90% RH
Recommended altitude
0 - 2000 m
Conformity
Reference standard
(certifications on-going)
CE, FCC, RoHS, UKCA
Table1 - Technical specifications
5.Device description
5.1. Overview
Figure1 shows a global overview of the device.
Figure1 - Device overview
Copyright © Terabee 2022
Terabee, 90 rue Henri Fabre
01630 Saint-Genis-Pouilly, France (next to CERN)
Terabee Air Quality IN5 User manual
Version 1.1
5 / 26

5.2. LED
The LED (Figure2) provides visual feedback of the system. Please refer to the Figure6 to
know the colour's meaning.
Figure2 - LED overview on the device
5.3. Button
The button (see Figure3) is usable with a needle or a very thin object.
Figure3 - Button
The button has 2 press types as shown in Table2.
Press type
Definition
Usage
Short press
Hold the button, then
release before 2 seconds
Enter in the configuration
state.
Copyright © Terabee 2022
Terabee, 90 rue Henri Fabre
01630 Saint-Genis-Pouilly, France (next to CERN)
Terabee Air Quality IN5 User manual
Version 1.1
6 / 26

See 7.1. Config state
section.
Long press
Hold the button, then
release after 2 seconds
Reset all the device
settings.
See 7.3. Factory Reset state
section.
Table2 - Button press definition
5.4. Power plug
The device is powered by an USB type C cable as shown in Figure4.
Figure4 - USB type C power plug
6.Quick device set up
Here is the procedure to set up your device quickly. If you want more information,
please read the next sections.
1. Power on the device
Connect the Terabee Air Quality IN5 device to the USB-C power supply.
Once powered, the device is ready within 10 seconds.
Copyright © Terabee 2022
Terabee, 90 rue Henri Fabre
01630 Saint-Genis-Pouilly, France (next to CERN)
Terabee Air Quality IN5 User manual
Version 1.1
7 / 26

The flashing blue LED indicates that the device is in config state and activates a
Wireless Access Point with the following format: TAQ-IN5_xx:xx:xx:xx:yy:yy
2. Connect to the Access Point
From a smartphone or a computer, connect to the Access Point using the following
credentials:
○SSID: TAQ-IN5_xx:xx:xx:xx:yy:yy (where x and y represent any hexadecimal
digit)
○Password: PW yyyy (with 2 spaces between PW and yyyy, yyyy is a 4
hexadecimal digit from the last part of the SSID above)
WiFi restrictions
Only 2.4GHz WiFi can be used.
3. Configure your WiFi communication
Once connected to the access point, open a Web browser and go to: https://192.168.4.1
to access the Configuration Web app.
Enter your in-home Wi-Fi network SSID and password.
Copyright © Terabee 2022
Terabee, 90 rue Henri Fabre
01630 Saint-Genis-Pouilly, France (next to CERN)
Terabee Air Quality IN5 User manual
Version 1.1
8 / 26

4. You’re all set!
The device is configured and starts pushing your data to the network.
7.Device behavior
The device has 2 main states:
●Config state: the device is ready to be configured
●Nominal state: the device measures the air quality and send data to the
network
Copyright © Terabee 2022
Terabee, 90 rue Henri Fabre
01630 Saint-Genis-Pouilly, France (next to CERN)
Terabee Air Quality IN5 User manual
Version 1.1
9 / 26

This behavior is detailed in Figure5 below.
Figure5 - Device state machine
7.1. Config state
At the first power on, the device is blocked in the config state waiting for WiFi
parameters to connect to the Internet. The LED flashes in blue in this state.
In this state, the device activates a WiFi access point and provides a Web app to
configure (see 8.1. Configuration Web app section) in order to connect the device to a
smartphone or computer and configure it.
To force the config state when the product has already been configured, you need to do
a short press on the button (press the button between 0 and 2 seconds). See 5.3. Button
section.
7.2. Nominal state
As soon as the WiFi connection is set, the device goes into nominal state. The device
stays in this state until you press the button or any internal error occurs.
In this state, the device:
●pushes data to the network every 2 minutes,
●activates a display Web app (see 8.2. Air Quality displaying Web app section)
allowing you to visualize air quality measurements.
Copyright © Terabee 2022
Terabee, 90 rue Henri Fabre
01630 Saint-Genis-Pouilly, France (next to CERN)
Terabee Air Quality IN5 User manual
Version 1.1
10 / 26

The LED indicates the air quality for 10 seconds, then the device status for 10 seconds
and loops again to the air quality indicator as shown in Figure6 and Table 3.
Figure6 - LED colours meaning
The sensors are not operational just after the power on. They need a warm up phase
which takes between 10 and 15 minutes. The LED is set on in solid white during this
phase.
7.3. Factory Reset state
If you want to erase all your settings (eg. WiFi parameters), you can force a factory reset
using a long press on the button (press for more than 2 seconds and release the
button). The LED will flash in red during 3 seconds and the device state will be forced to
the config state.
If you just want to modify existing WiFi parameters, you can force entering in the
config state using a short press on the button (instead of using the factory reset).
7.4. LED behaviour
Device status
LED Colour
Status
Flashing blue
Config state
Access point is activated, the device needs to be
Copyright © Terabee 2022
Terabee, 90 rue Henri Fabre
01630 Saint-Genis-Pouilly, France (next to CERN)
Terabee Air Quality IN5 User manual
Version 1.1
11 / 26

connected to the Internet.
White steady
Nominal state
Warm up phase takes between 5-10 minutes.
Flashing pink
Device is not connected
Device is in Nominal state but is not connected anymore.
Air quality indicator*
LED Colour
Status
Green
Excellent Air Quality Environment
Light Blue/Green
Good Air Quality Environment
Orange
Fair Air Quality Environment
Red
Poor Air Quality Environment
Table3 - LED behaviour
*Nominal state: Based on CO2, Particulate Matter (PM) and Total Volatile Organic
Compounds values.
8. Web applications
8.1. Configuration Web app
This Web application is only available when the device is in the config state (see 7.1.
Config state section). In this state, the device enables an access point allowing you to
connect a computer or a smartphone to the device. Please refer to the 6. Quick device
setup section.
Ensure your computer or smartphone is connected to the WiFi access point of the
device, open a Web browser and go to this url: https://192.168.4.1
The application is not reachable using http.
Only https is usable.
When the application is launched, you will see a Web form as shown in the Figure7. The
Tab “Configure” allows you to modify some settings whereas the tab “Update” allows
you to update the device.
Copyright © Terabee 2022
Terabee, 90 rue Henri Fabre
01630 Saint-Genis-Pouilly, France (next to CERN)
Terabee Air Quality IN5 User manual
Version 1.1
12 / 26

The Update feature is not yet available (still in development), so the button “Launch
update” has no effect.
Figure7 - Configuration Web app
8.2. Air Quality displaying web app
This web application is only available when the device is in the nominal state (see 7.2.
Nominal state section). In this state, the device tries to connect to your WiFi network.
Copyright © Terabee 2022
Terabee, 90 rue Henri Fabre
01630 Saint-Genis-Pouilly, France (next to CERN)
Terabee Air Quality IN5 User manual
Version 1.1
13 / 26

WiFi restrictions
Only 2.4GHz WiFi can be used.
If the device fails in connecting to the WiFi network (no network, or bad WiFi
parameters), the LED flashes in pink for 10 seconds every minute and the Air Quality
displaying web app is not available.
To launch the Air Quality displaying web app, open a web browser and type the
Terabee Air Quality IN5 IP address using this format https://IP address. For instance
https://192.168.1.2
Use the IP address assigned by your WiFi router (in most cases, the IP address is
available in your router administration page, next to the device name “Terabee Air
Quality IN5”), as shown in Figure8.
Figure8 - Example of a router administration page
The application is not reachable using http.
Only https is usable.
When the app is launched, you will see a web page with some widgets to observe the air
quality as shown in the Figure9 and Figure10.
Copyright © Terabee 2022
Terabee, 90 rue Henri Fabre
01630 Saint-Genis-Pouilly, France (next to CERN)
Terabee Air Quality IN5 User manual
Version 1.1
14 / 26

Figure10 - Air Quality web app (mobile version)
Copyright © Terabee 2022
Terabee, 90 rue Henri Fabre
01630 Saint-Genis-Pouilly, France (next to CERN)
Terabee Air Quality IN5 User manual
Version 1.1
16 / 26

9. Troubleshooting
Problem
Suggestion
The LED remains off
Please check if the USB type C cable is
well plugged in. If OK, try to unplug and
plug again. The LED would switch on after
5 seconds.
The configuration Web application is
not reachable at https://192.168.4.1
Please check that you don’t try to access
this page using http. Only https is
available.
Please check that the LED is blinking in
blue. If it’s not the case, the device is not
in the config state, so this url is not
enabled. Do a short press (< 2s) on the
button to enter in the config state, and
try again to load the app at
https://192.168.4.1.
The device has a WiFi configuration
but the LED still blinks in pink
Please ensure your WiFi router provides
2.4 GHz network.
If this section doesn’t help you, please contact your commercial representative or our
description, some photos and screenshots are often useful to identify the problem)
10. Cleaning instructions
In case the product has been soiled, it is recommended to use a dry or slightly damp
cloth to clean the outer part of the product only.
Do not use any products directly on this device as they may influence the values read by
the sensor in a definitive way.
Copyright © Terabee 2022
Terabee, 90 rue Henri Fabre
01630 Saint-Genis-Pouilly, France (next to CERN)
Terabee Air Quality IN5 User manual
Version 1.1
17 / 26

11. Maintenance
Terabee Air Quality IN5 is given for a lifetime of 10 years.
the sensor components.
The user is not allowed to open the product or perform maintenance himself and must
contact Terabee support services in case a problem is faced.
TERABEE
Telephone: +33 (6) 23 60 01 48
Mail: [email protected]
Address: 90, rue Henri Fabre, 01630 Saint-Genis-Pouilly, France
12. Safety and regulatory statement
12.1 Safety instruction
EN To avoid the risk of electric shock no modification of this equipment is allowed. Do
not restrict the airflow of the product. Not to be used by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction. Children should be
supervised to ensure: that they do not play with the appliance. If the power cord is
damaged in any way it must be replaced by a special cord or assembly available from
the manufacturer or its service agent. Terabee Air Quality IN5 not a water-resistant
device; keep the device away from water or any moisture. It is mandatory to use the
AC/DC power adapter: ULLPOWER, modèle/ ICP06c-050-1000B, INPUT : 100-240V ~
50/60Hz 0.3A, OUTPUT : 5.0V - 1.0A, RATED POWER: 5.0W and the USB-C cable
furnished by Terabee in this package.
If the device is used in a manner not specified by the manufacturer, the protection provided
by the device may be compromised.
FR Pour éviter tout risque d'électrocution. Aucune modification de cet équipement
n'est autorisée. Ne pas restreindre le flux d'air du produit. Ne doit pas être utilisé par
des personnes (y compris des enfants) dont les capacités physiques, sensorielles ou
mentales sont réduites, ou qui manquent d'expérience et de connaissances, à moins
qu'elles n'aient reçu une surveillance ou des instructions. Les enfants doivent être
surveillés pour s'assurer qu'ils ne jouent pas avec l'appareil. Si le cordon d'alimentation
Copyright © Terabee 2022
Terabee, 90 rue Henri Fabre
01630 Saint-Genis-Pouilly, France (next to CERN)
Terabee Air Quality IN5 User manual
Version 1.1
18 / 26

est endommagé de quelque façon que ce soit, il doit être immédiatement remplacé par
un cordon ou un assemblage spécial disponible auprès du fabricant ou de son agent de
service. Le Terabee Air Quality IN5 n'est pas un appareil résistant à l'eau ; gardez
l'appareil à l'abri de l'eau ou de toute humidité. Il est obligatoire d'utiliser l'adaptateur
d'alimentation AC/DC : ULLPOWER, modèle/ ICP06c-050-1000B, INPUT : 100-240V ~
50/60Hz 0.3A, OUTPUT : 5.0V - 1.0A, RATED POWER : 5.0W et le câble USB-C fourni par
Terabee dans cet emballage.
Si l'appareil est utilisé d'une manière non spécifiée par le fabricant, la protection fournie par
l'appareil peut être compromise.
DE Um die Gefahr eines Stromschlags zu vermeiden. An diesem Gerät dürfen keine
Änderungen vorgenommen werden. Den Luftstrom des Geräts nicht einschränken. Das
Gerät darf nicht von Personen (einschließlich Kindern) mit eingeschränkten physischen,
sensorischen oder mentalen Fähigkeiten oder mangelnder Erfahrung und Kenntnissen
benutzt werden, es sei denn, sie werden beaufsichtigt oder erhalten Anweisungen.
Kinder sollten beaufsichtigt werden, um sicherzustellen, dass sie nicht mit dem Gerät
spielen. Wenn das Netzkabel in irgendeiner Weise beschädigt ist, muss es durch ein
spezielles Kabel oder eine spezielle Baugruppe ersetzt werden, die beim Hersteller oder
seinem Kundendienst erhältlich ist. Terabee Air Quality IN5 ist nicht wasserfest; halten
Sie das Gerät von Wasser oder Feuchtigkeit fern. Es ist zwingend erforderlich, den
AC/DC-Netzadapter zu verwenden: ULLPOWER, modèle/ ICP06c-050-1000B, INPUT :
100-240V ~ 50/60Hz 0.3A, OUTPUT : 5.0V - 1.0A, RATED POWER: 5.0W und das von
Terabee in diesem Paket mitgelieferte USB-C-Kabel.
Wenn das Gerät auf eine Weise verwendet wird, die nicht vom Hersteller angegeben wurde,
kann der vom Gerät gebotene Schutz beeinträchtigt werden.
ES Para evitar el riesgo de descarga eléctrica no se permite ninguna modificación de
este equipo. No restrinja el flujo de aire del producto. No debe ser utilizado por
personas (incluidos los niños) con capacidades físicas, sensoriales o mentales reducidas,
o con falta de experiencia y conocimientos, a menos que hayan recibido supervisión o
instrucciones. Los niños deben ser supervisados para garantizar que no jueguen con el
aparato. Si el cable de alimentación está dañado de alguna manera, debe ser sustituido
por un cable o un conjunto especial disponible en el fabricante o en su agente de
servicio. El Terabee Air Quality IN5 no es un aparato resistente al agua; mantenga el
aparato alejado del agua o de cualquier humedad. Es obligatorio utilizar el adaptador
de corriente AC/DC: ULLPOWER, modèle/ ICP06c-050-1000B, ENTRADA : 100-240V ~
50/60Hz 0,3A, SALIDA : 5,0V - 1,0A, POTENCIA NOMINAL: 5,0W y el cable USB-C
suministrado por Terabee en este paquete.
Si el dispositivo se utiliza de una manera no especificada por el fabricante, la protección
proporcionada por el dispositivo puede verse comprometid
IT Per evitare il rischio di scosse elettriche, non è consentito modificare questa
apparecchiatura. Non limitare il flusso d'aria del prodotto. Non deve essere utilizzato da
persone (compresi i bambini) con ridotte capacità fisiche, sensoriali o mentali, o con
Copyright © Terabee 2022
Terabee, 90 rue Henri Fabre
01630 Saint-Genis-Pouilly, France (next to CERN)
Terabee Air Quality IN5 User manual
Version 1.1
19 / 26

mancanza di esperienza e conoscenza, a meno che non abbiano ricevuto supervisione o
istruzioni. I bambini devono essere sorvegliati per garantire che non giochino con
l'apparecchio. Se il cavo di alimentazione è danneggiato in qualsiasi modo, deve essere
sostituito con un cavo o un gruppo speciale disponibile presso il produttore o il suo
agente di assistenza. Terabee Air Quality IN5 non è un apparecchio resistente all'acqua;
tenere l'apparecchio lontano da acqua o umidità. È obbligatorio utilizzare l'adattatore di
alimentazione CA/CC: ULLPOWER, modèle/ ICP06c-050-1000B, INPUT : 100-240V ~
50/60Hz 0.3A, OUTPUT : 5.0V - 1.0A, RATED POWER: 5.0W e il cavo USB-C fornito da
Terabee in questa confezione.
Se il dispositivo viene utilizzato in modo diverso da quello specificato dal produttore, la
protezione fornita dal dispositivo potrebbe essere compromessa.
NL Om het risico van elektrische schokken te vermijden is het niet toegestaan
wijzigingen aan dit apparaat aan te brengen. De luchtstroom van het product niet
beperken. Niet te gebruiken door personen (inclusief kinderen) met verminderde
fysieke, zintuiglijke of mentale mogelijkheden, of gebrek aan ervaring en kennis, tenzij
zij onder toezicht of instructie staan. Kinderen moeten onder toezicht staan om ervoor
te zorgen: dat zij niet met het apparaat spelen. Als het netsnoer op enigerlei wijze
beschadigd is, moet het worden vervangen door een speciaal snoer of een assemblage
die verkrijgbaar is bij de fabrikant of zijn serviceagent. De Terabee Air Quality IN5 is
geen waterbestendig apparaat; houd het apparaat uit de buurt van water of vocht. Het
is verplicht de AC/DC stroomadapter te gebruiken: ULLPOWER, modèle/
ICP06c-050-1000B, INPUT : 100-240V ~ 50/60Hz 0,3A, OUTPUT : 5,0V - 1,0A, RATED
POWER: 5,0W en de USB-C kabel die door Terabee in dit pakket wordt geleverd.
Als het apparaat wordt gebruikt op een manier die niet door de fabrikant is gespecificeerd,
kan de door het apparaat geboden bescherming in gevaar komen.
PT Para evitar o risco de choque eléctrico, não é permitida qualquer modificação deste
equipamento. Não restringir o fluxo de ar do produto. Não deve ser utilizado por
pessoas (incluindo crianças) com capacidades físicas, sensoriais ou mentais reduzidas,
ou com falta de experiência e conhecimentos, a menos que lhes tenha sido dada
supervisão ou instrução. As crianças devem ser supervisionadas para garantir: que não
brincam com o aparelho. Se o cabo de alimentação for danificado de alguma forma,
deve ser substituído por um cabo ou conjunto especial disponível junto do fabricante
ou do seu agente de serviço. Terabee Air Quality IN5 não é um dispositivo resistente à
água; mantenha o dispositivo afastado da água ou de qualquer humidade. É obrigatória
a utilização do adaptador de corrente AC/DC: ULLPOWER, modèle/ ICP06c-050-1000B,
INPUT : 100-240V ~ 50/60Hz 0.3A, OUTPUT : 5.0V - 1.0A, POTÊNCIA RATEADA: 5.0W e o
cabo USB-C fornecido pela Terabee neste pacote.
Se o dispositivo for utilizado de uma forma não especificada pelo fabricante, a protecção
fornecida pelo dispositivo pode ser comprometida.
SE För att undvika risken för elektriska stötar är det inte tillåtet att ändra den här
utrustningen. Begräns inte produktens luftflöde. Får inte användas av personer
Copyright © Terabee 2022
Terabee, 90 rue Henri Fabre
01630 Saint-Genis-Pouilly, France (next to CERN)
Terabee Air Quality IN5 User manual
Version 1.1
20 / 26
Table of contents
Other TeraBee Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Burkert
Burkert 8640 quick start

SATO KEIRYOKI
SATO KEIRYOKI SK-5RAD-MR instruction manual

SK telecom
SK telecom Air Cube T instruction manual

Endress+Hauser
Endress+Hauser Proline Promag P 100 technical information

Fast Forward
Fast Forward EnergyCam Getting Started Tutorial

Mantech
Mantech L100 PeCOD Operation manual