ᘻ᩿ዓဇ⇶∞ኵᇌᙲ
Rear connection Flat bar
Instruction Manual
࢟ࡸ(Types)
TPRP05K
TPRP12K
TPRP05S
TPRP16S
ᮏ᭩䛿䠈Te m B r e a k 2 䝅䝸䞊䝈䛻㠃᥋⥆⏝䝞䞊䜢ྲྀ䛡䜛せ㡿䜢グ㍕䛧䛶䛔䜎䛩䚹㻌
This document has described the procedure which attaches Rear conection Flat bar in
Te m B r e a k 2 series.
ᮏ᭩ࡣ㸪ࡈ⏝࡞ࡿ᪉ࡢ࠾ᡭඖ࡛ษಖ⟶ୗࡉ࠸ࠋᮏ᭩グ㍕ࡢ࡞࠸ྲྀᢅ
࠸㸪ཬࡧㄗࡗࡓྲྀᢅ࠸ࡼࡾ⏕ࡌࡿᦆᐖ㛵ࡋ࡚㸪ᘢ♫ࡣ㈐௵ࢆ㈇࠸ࡲࡏࢇࠋ
Please retain this manual for future reference. The Manufacturer assumes no responsibility for
damages resulting from non-application or incorrect application of the instructions provided herein.
2G1459SAD 㻔KRB-0989d㻕
ڧ
3
ܤμɥ↝Ↄද
Safety Notice
ᕤ㸪⏝㸪ಖᏲ࣭Ⅼ᳨ࡢ๓㸪ᚲࡎᮏ᭩ࡑࡢࡢᒓ᭩㢮ࢆ࠾ㄞࡳ㡬ࡁ㸪
ᶵჾࡢ▱㆑㸪Ᏻࡢሗ㸪ཬࡧὀព㡯ࡢ࡚⩦⇍ࡋ࡚ࡽ࠾ྲྀᢅ࠸ୗࡉ࠸ࠋ
ᮏ᭩࡛ࡣ㸪Ᏻὀព㡯ࡢࣛࣥࢡࢆࠕ ༴㝤ࠖ㸪ࠕ ὀពࠖ༊ศࡋ࡚࠸ࡲࡍࠋ
༴㝤㸸
ྲྀᢅ࠸ࢆㄗࡗࡓሙྜ㸪༴㝤࡞≧ἣࡀ㉳ࡇࡾ࠼࡚㸪Ṛஸࡲࡓࡣ㔜യࢆཷ
ࡅࡿྍ⬟ᛶࡀᐃࡉࢀࡿሙྜࠋ
ὀព㸸
ྲྀᢅ࠸ࢆㄗࡗࡓሙྜ㸪༴㝤࡞≧ἣࡀ㉳ࡇࡾ࠼࡚㸪୰⛬ᗘࡢയᐖࡸ㍍യ
ࢆཷࡅࡿྍ⬟ᛶࡀᐃࡉࢀࡿሙྜཬࡧ≀ⓗᦆᐖࡢࡳࡀᐃࡉࢀࡿሙྜࠋ
࡞࠾㸪ࠕ ὀពࠖグ㍕ࡋࡓ㡯࡛ࡶ㸪≧ἣࡼࡗ࡚ࡣ㔜࡞⤖ᯝ⤖ࡧࡘࡃྍ
⬟ᛶࡀ࠶ࡾࡲࡍࠋ࠸ࡎࢀࡶ㔜せ࡞ෆᐜ࡛ࡍࡢ࡛㸪ᚲࡎᏲࡗ࡚ୗࡉ࠸ࠋ
Be sure to read these Instructions and other associated documents accompanying the product
thoroughly to be familiarize yourself with the product handling, safety information, and all other
precautions before mounting, using, servicing, or inspecting the productIn these Instructions,
safety notices are divided into Warning and Caution according to the hazard level:
Warning :
A warning notice with this symbol indicates that neglecting the suggested procedure
or practice could result in lethal or serious personal injury.
Caution :
A caution notice with this symbol indicates that neglecting the suggested procedure or
practice could result in moderate or slight personal injury and/or property damage.
Note that failing to observe Caution notices could result in serious injury/damage in some situations.
Because safety notices contain important information, be sure to read and observe them.
༴㝤Warning
ڦ⏝ୖࡢࡈὀពOperation Precautions
ە㟁➃Ꮚ㒊ゐࢀ࡞࠸࡛ୗࡉ࠸ࠋឤ㟁ࡢ࠾ࡑࢀࡀ࠶ࡾࡲࡍࠋ
Never touch live terminals. Doing so may result in electric shock.
ὀពCaution
ڦᕤୖࡢࡈὀពInstallation Precautions
ە㟁Ẽᕤࡣ㸪᭷㈨᱁⪅㸦㟁Ẽᕤኈ㸧ࡀ⾜ࡗ࡚ୗࡉ࠸ࠋ
Installation work must be performed by competent persons.
ەసᴗࡣ㸪ୖ㐽᩿ჾ➼ࢆษ㸦2))㸧ࡋ㸪ᅇ㊰ཬࡧไᚚᅇ㊰ࡀ㟁ࡋ࡚
࠸࡞࠸ࡇࢆ☜ㄆࡋ࡚⾜ࡗ࡚ୗࡉ࠸ࠋឤ㟁ࡢ࠾ࡑࢀࡀ࠶ࡾࡲࡍࠋ
Prior to commencing any work on the product, open an upstream circuit breaker or the
like to isolate all sources of power/voltage. Doing so may result in electric shock.
ە㠃᥋⥆⏝ࣂ࣮㐽᩿ჾࡢྲྀ㠃ࢆࡁࢀ࠸ࡋ࡚ୗࡉ࠸ࠋởࢀࡓ≧ែ࡛ࡢ
ྲྀࡅࡣ㸪ⅆ⅏ࡢཎᅉ࡞ࡾࡲࡍࠋ
Clean the Rear connection Flat bar mounting surface (contact surface with the breaker
terminals). Otherwise, a fire may result.
ە㠃ࢫࢱࢵࢻࡣ㸪ࡑࡢྲྀ㠃ࡀ㐽᩿ჾࡢྲྀ㠃ࡋࡗࡾ᥋ゐࡍࡿࡲ࡛
ዟᕪ㎸ࢇ࡛ࡽ⥾ࡅ࡚ୗࡉ࠸ࠋ᥋ゐⰋࡣ㸪ⅆ⅏ࡢཎᅉ࡞ࡾࡲࡍࠋ
Insert the Rear connection Flat bar to the full depth until the mounting surface comes into
contact with the breaker terminals, and tighten it with the stud fixing screws. Otherwise, a
fire may result.
ڧ
1
ᢘဇᢚૺ֥࢟ࡸ↗ӷԼ
Applicable Breaker Types/ Packaged Items
#3 : M616
ڧ
2
࣏ᙲ↗↙↺φ
Assembly tools
ὀពCaution
ڦᕤୖࡢࡈὀពInstallation Precautions
ە㠃᥋⥆⏝ࣂ࣮ᅛᐃࡡࡌ㸪ཬࡧ➃Ꮚࡡࡌࡣ㸪ᶆ‽⥾ࢺࣝࢡ࡛☜ᐇ㐽᩿
ჾ⥾ࡅ࡚ୗࡉ࠸ࠋ⥾ࡅഛࡣⅆ⅏ࡢ࠾ࡑࢀࡀ࠶ࡾࡲࡍࠋ
Tighten the Rear connection Flat bar fixing screws and the terminal screws to the torque
specified in this manual. Otherwise, a fire may result.
ە➃Ꮚࡡࡌࡢ⥾ࡅཬࡧ᥋⥆ᚋ㸪㠃᥋⥆⏝ࣂ࣮↓⌮࡞ຊࡀຍࢃࡽ࡞࠸
ࡼ࠺ࡋ࡚ୗࡉ࠸ࠋ㠃ࢫࢱࢵࢻࡢ㐣࡞ᛂຊࡣ㸪ⅆ⅏ࡢ࠾ࡑࢀࡀ࠶ࡾ
ࡲࡍࠋ
Even when tightening the terminal screws and after conductor connection, do not apply
excessive force to the Rear connection Flat bar. Otherwise, a fire may result.
ە᥋⥆ᑟయࡣ㸪㏻㟁㟁ὶᛂࡌ࡚ࡁ࡞㟁☢ຊࡀⓎ⏕ࡍࡿࡓࡵ㸪ୗ⾲ࡢ⨨
࡛ᅛᐃ㸦⤖᮰㸧ࡋ࡚ୗࡉ࠸ࠋ
Each connected conductor must be supported at a distance P. See following table.
㠃᥋⥆⏝ࣂ࣮㓄⨨
Rear connection Flat bar arrengement 0r 45r, 90r
ᅛᐃ⨨ P
Distance P Pӌ350mm Pӌ200mm
ەࡡࡌࡣྠᲕࡉࢀ࡚࠸ࡿࡶࡢࢆࡈ⏝ࡃࡔࡉ࠸ࠋࡡࡌࡢᙧ≧ࡀᕷ㈍ࡢࡶࡢ
ࡣ␗࡞ࡿሙྜࡀ࠶ࡾࡲࡍࠋ
Use the screws included in the package. The shape of the screw may differ from the one
on the market.
ەྲྀࡅࡽࢀࡓ㐽᩿ჾࢆྲྀእࡍࡁࡣ㸪㠃᥋⥆⏝ࣂ࣮ᅛᐃࡡࡌࢆ⦆ࡵࡓ
ࡾ㸪እࡋࡓࡾࡋ࡞࠸࡛ୗࡉ࠸ࠋᑟయࢆྲྀእࡋ࡚ࡽ㸪㐽᩿ჾࢆྲྀእࡋ࡚ୗ
ࡉ࠸ࠋ
When removing the installed breaker, loosen the terminal screws without loosing the Rear
connection Flat bar fixing screws.
ڦ⏝ୖࡢࡈὀពOperation Precautions
ە⮬ືⓗ㐽᩿ჾࡀࢺࣜࢵࣉ㸦㐽᩿㸧ࡋࡓሙྜࡣ㸪ཎᅉࢆྲྀࡾ㝖࠸࡚ࡽධ
㸦ON㸧᧯సࡋ࡚ୗࡉ࠸ࠋⅆ⅏ࡢ࠾ࡑࢀࡀ࠶ࡾࡲࡍࠋ
When the breaker trips open automatically, remove the cause; then close the breaker.
Otherwise, a fire may result.
ڦಖᏲ࣭Ⅼ᳨ୖࡢࡈὀពMaintenance Precautions
ەಖᏲ࣭Ⅼ᳨ࡣ㸪ᑓ㛛▱㆑ࢆ᭷ࡍࡿேࡀ⾜ࡗ࡚ୗࡉ࠸ࠋ
Service and/or inspection of the product must be done by persons having expert
knowledge.
ەಖᏲ࣭Ⅼ᳨ࡣ㸪ୖ㐽᩿ჾࢆษ㸦OFF㸧ࡋ㸪㟁ࡋ࡚࠸࡞࠸ࡇࢆ☜ㄆ
ࡋ࡚⾜ࡗ࡚ୗࡉ࠸ࠋឤ㟁ࡢ࠾ࡑࢀࡀ࠶ࡾࡲࡍࠋ
Before service or inspection of this product, please ensure that no voltage is present on
the breaker supply side. Any device upstream of this breaker should be suitably isolated
otherwise electric shock may result.
ە㠃᥋⥆⏝ࣂ࣮ᅛᐃࡡࡌ㸪ཬࡧ➃Ꮚࡡࡌࡣ㸪ᐃᮇⓗᶆ‽⥾ࢺࣝࢡ࡛ቑ
ࡋ⥾ࡵࡋ࡚ୗࡉ࠸ࠋ⦆ࡳࡣ㸪ⅆ⅏ࡢཎᅉ࡞ࡾࡲࡍࠋ
Regularly check that the Rear connection Flat bar fixing screws and the terminal screws
are tightened to torque values shown within this manual, failure to do so may result in fire.
C
D
5
A
B
10 13 5
#4 : M622
10
#5 : M823
13
㠃᥋⥆⏝䝞䞊
Rear connection Flat bar
㐺⏝㐽᩿ჾᙧᘧ
Applicable Breaker Types ྠᲕ≀ Items
MCCB ELCB
ᴟᩘ
Poles ᙧᘧ
Types A B C D
2 TPRP052K 2 2 4 4
3 TPRP053K 2 4 6 6
PE30-NF/NN,
PS30-NF,
PE50-NF/NN/NFZ,
PS50-NF/NFZ
PZE30-NF,
PZS30-NF,
PZE50-NF,
PZS50-NF
#1 #4
2 TPRP122K 2 2 4 4
PE60-NF, PS60-NF,
PE125-NF/NN/NFZ
PZE60-NF,
PZS60-NF,
PZE125-NF 3 TPRP123K 2 4 6
#2
6
2 TPRP052S 2 2 4 4
3 TPRP053S 2 4 6 6
PS50-PF 䇷
4 TPRP054S 4 4 8
#1
(*1)
*1: ≉Ṧ䛽䛨 Special screw
8
#5
#1 : M514
#2 : M616
2 TPRP162S 2 2 4 4
3 TPRP163S 2 4 6 6
PS125-NF/PF/NM/NN,
PS125-NE/PE,
P160䕕
䇷
4 TPRP164S 4 4 8
#3
8
〒547-0002
大阪市平野区加美東6
–
13
–
47
TEL 06
–
6791
–
2756
FAX 06
–
6791
–
2732
https://www.terasaki.co.jp
kiki-info@terasaki.co.jp
6-13-47 Kamihigashi, Hiranoku, Osaka
547-0002, Japan
TEL +81-6-6791-2763
FAX +81-6-6791-2732
http://www.terasaki.co.jp