Electronic type B earth leakage current protection and monitoring relay. Associated to
external core balance transformer the . It has 2 programmables outputsyCTB-1/xxx famil
relays. Main trip and prealarm signal. It has one free voltage input for external TRIP/RESET.
Mounting in DIN rail 466277 (EN 50022) or PANEL 72x72 by means of accesories .3EDA03
Displays setting values and instantaneus earth leakage current value.
GENERAL DESCRIPTION
PRELIMINARY CONSIDERATIONS
INSTALLATION AND START-UP
IMPORTANT !
!
Tripping delay (s)
Sensivity (A)
Type
code
CHECKS ON RECEPTION
On receving the instrument, check the following points:
You can download more information from Contrel Elettronica website, www.contrel.it
SAFETY PRECAUTIONS
warning included in the instruction manual.
green LED (ON) when it is operation and, therefore, it shows that there is voltage and
The user must take into account and observe the informations and warnings included in
this instruction manual to guarantee the correct operation of the equipment and comply
the electrical panel.
Disconnect the equipment from the power supply when the unit´s safety protection
systems are not working or there are signs of a problem (in case of visible damage).
INSTALLING THE EQUIPMENT
Wheight : 168 gr
52,5
85
45
43,5
67,9
Fixed by rail DIN 46277 (EN 50022)
dimensions in mm.
Rated current: 10 Ac.a.
Rated voltage: 250 Vc.a.
Rated Load: 2.500 V·A
89
1245 6
10
11
13 14 15
Reset
Test
ELR-3B Residual Current device and Monitor type B
RGU - 10 C
3 Not used
4 Pre-alarm output relay common
5 Pre-alarm output relay, NC
6 Pre-alarm output relay, NA
7 Not used
8 Input Current sensor 1S2
9 Input Current sensor 1S1
10 Power Supply (L - 230 Vac or +/-24÷125Vdc)
11 Power supply (N - 230 Vac or +/-24÷125Vdc)
12 Not used
Optocoupled, 0.7W /230 Vac ± 20%
Rated current: 10 Ac.a.
Rated voltage: 250 Vc.a.
Rated Load: 2.500 V·A
ELR-3B
TECHNICAL FEATURES
- Reclosing type: Manual via RESET button or by cutting power supply.
- Rated power supply voltage: 230 ( 20%) 50/60 Hz, 6 VA
±
- : -10ºC / +50ºCOperating temperature
- Humidity (without condensation) : 5% .... 95%
- IP Protection
Assembled equipment (front) : IP 41
Non assembled equipment (sides and rear cove) : IP 20
- Maximum operating height : 2000 m.
-:Connections
2
0,127 - 2,082 mmPermissible cable section:
Recommended tightening torque: 0.5-0.6 Nm
Length of cable to strip: 7 mm
Recommended screwdrivers length: Bar 0.4 x 2.5 x 80 mm, 160 mm
- 13-14-15 and 4-5-6Switch Output contact features
: 10 / 15 A a.c.Rated current/Maximum instant current
: 250 / 400 V a.c.Rated voltage/Maximum switching voltage
AC1: 2,500 V·ARated load in
DIMENSION
Instruction Manual IM4000-U-T v0.92
Pag. 1/2
IM4000-U-T v0.92
Rated Power Supply
3ED36G ELR-3B 0,1-0,2-0,3-0,4-0,5-0,75-1-5-10 220-240V 50-60Hz
3ED36T ELR-3B 24-125
0,03-0,1-0,3-0,5-1-3
0,03-0,1-0,3-0,5-1-3 0,1-0,2-0,3-0,4-0,5-0,75-1-5-10 24÷125V dc
Optional front panel adapter