Terra OD001A User manual

Optical receivers OD001A, OD002
Draugystes str. 22, LT-51256 Kaunas, Lithuania, tel.: +370 37
-
31 34 44, fax: +370 37
-
31 35 55
Product description
Optical receivers (in text - receivers) are intended to convert optical signals into electrical signals, amplify and distribute
TV signals in cable TV distribution networks.
Receivers are produced with built-in switch-mode power supply for powering from the mains ~187...250 V and
DC 12...18 V through RF output (OD001A).
The receivers are intended for indoor use only.
Safety instructions
Installation of the receivers must be done according safety standards and by qualified service personnel.
The voltage of receivers is powered from is dangerous to life.
Receivers are double isolated from the mains ~230 V.
Equipment for DC remote powering of receivers must have protection from short connection.
To ensure safe operation of the receivers follow these instructions:
connect receivers to earth before power supplying;
do not plug the receivers into the mains supply if the power cord or plug are damaged and until all cables have been
connected correctly;
the mains socket must be easily accessible;
avoid placing the receivers next to heating components;
ensure normal ventilation conditions for the receivers;
an optical connector after disconnection emits optical radiation;
avoid looking directly into beam, laser light can cause eye injuries and result in permanent loss of vision.
Operating controls

Structure diagram
Installation
The receivers should be mounted vertically with cable inputs underneath in order to ensure good ventilation conditions.
Ground the receivers housing connection "earthing clamp" with at least ∅∅
∅∅
∅4 mm2wire to an earth connection.
Fiber installation should be done very carefully. Bending radius of fibers must be not less 25 mm. All optical connectors and
adaptors should be cleaned before connecting them.
Default settings
The receivers are supplied with the following default settings:
A1 AC
A2 0 dB
Eq 0 dB
After powering of module restarted the internal microcontroller recovers the settings before powering lost.
Power supply
Receivers have the mains powering. It is powered from ~187...250 V via the AC power cord. DC 12...18 V feeding through
RF output port allows simply realize functions of remote powering or power redundancy (OD001A).
Operating and adjustment
There are adjustment buttons on the panel of the receiver. Parameters can be controlled and monitored with adjustments
buttons. Values of parameters are dispayed on LED display.
Adjustments buttons:
- button marked "Mode" is used for selecting parameter;
- button marked "Value" is used for changing value or monitoring.
The following parameters of the receivers can be changed or monitored:
1) A1 - first attenuator, value (in dB): 0; 1; 2...19; 20; AC. AC - automatic gain control (AGC). If this function is selected,
the output level will be constant by changing optical input level in range -7... 2 dBm.
2) A2 - interstage attenuator, value (in dB): 0; 0.5; 1.0; 1.5...9.5; 10.
3) Eq - interstage equalizer, value (in dB): 0; 5; 10.
4) tE - internal temperature.
5) OL - optical input power in dBm, when indicator is blinking - optical input power has a positive meaning, if not - negative.
h
2

Technical characteristics
* output level (CTB, CSO) is measured with 5 dB interstage equalizer
softwarecontrol
pr.
pr.
pr.
Type OD001A OD002
Opticalwave lenght 1100-1600nm
AGC controlled optical input level -7 ... 2 dBm
Noise current density ≤ 7.0 pA/√kHz
Frequencyrange 47-862MHz
Impedance 75Ω
Return loss 18 dB/40MHz-1.5dB/oct
Frequency response ±0.75dB
Output level (AGC controlled, 4.9% OMI) 95 dBµV 107dBµV
Output level*(CTB ≤60 dB, 42 ch. Cenelec) 99 dBµV 107dBµV
Output level*(CSO ≤60 dB, 42 ch. Cenelec) 101dBµV 110dBµV
Interstageattenuator 0-10 dB by 0.5 dBstep
Interstage equalizer 0/5/10 dB switchable
Powerconsumption AC 187-250 V/5 W; DC 12-18 V/4 W AC 187-250 V/6 W
Current consumption 12 V DC 0.27A -
14 V DC 0.24A -
16 V DC 0.20A -
18 V DC 0.18A -
Loss in test point -20 dB
Optical connector SC/APC
RF connectors F
Operating temperature range -20o÷+ 60oC
Dimensions/Weight(packed) 185.5x95x47mm/0.9kg
Diagnostic
Internal microcontroller scans and collects diagnostic data.
Diagnostic information is displayed on internal LED display. Meanings of diagnostic messages see in table.
Diagnostic messages on LED display Comments
E1 no input signal
E2 AGC out of range
E4 overheat
E3 no input signal and AGC out of range
E5 overheat and no input signal
E6 AGC out of range and overheat
E7 no input signal, AGC out of range and overheat
ÒèïÒèï
ÒèïÒèï
Òèï OD001AOD001A
OD001AOD001A
OD001A OD002OD002
OD002OD002
OD002
Äëèíà âîëíû 1100-1600nm
Îïòè÷åñêèé óðîâåíü íà âõîäå êîíòðîëèðóåìûé APÓ -7... 2 dBm
×óâñòâèòåëüíîñòü ≤ 7.0 pA/√kHz
×àñòîòíûé äèàïàçîí 47-862MHz
Èìïåäàíñ 75 Ω
Êîýôôèöèåíòîòðàæåíèÿ 18 dB/40 MHz-1.5 dB/íà îêòàâó
Íåðàâíîìåðíîñòü À×Õ ± 0.75 dB
Âûõîäíîé óðîâåíü (êîíòð. ÀÐÓ, 4.9 % OMI) 95 dBµV 107 dBµV
Âûõîäíîé óðîâåíü*(CTB ≤60 dB, 42 êàí. Cenelec) 99 dBµV 107 dBµV
Âûõîäíîé óðîâåíü* (CSO≤60 dB, 42 êàí. Cenelec) 101 dBµV 110 dBµV
Ìåæêàñêàäíûé àòòåíþàòîð 0-10 dB ñ øàãîì 0.5 dB
Ìåæêàñêàäíûé êîððåêòîð 0/5/10 dB êîììóòèðóåìûé
Ïîòðåáëÿåìàÿ ìîùíîñòü AC 187-250 V/5 W; DC 12-18 V/4 W AC 187-250 V/6 W
Ïîòðåáëÿåìûé òîê 12 V DC 0.27 A -
14 V DC 0.24 A -
16 V DC 0.20 A -
18 V DC 0.18 A -
Êîýôôèöèåíò îñëàáëåíèÿ íà êîíòðîëüíîì âûâîäå -20 dB
Îïòè÷åñêèé ðàçúåì SC/APC
Â× ðàçúåìû F
Äèàïàçîí ðàáî÷èõ òåìïåðàòóð -20o÷+ 50oC
Ãàáàðèòû/Âåñ (â óïàêîâêå) 185.5x95x47 mm/0.9 kg
* âûõîäíîé óðîâåíü (CTB, CSO) èçìåðåí ñ ìåæêàñêàäíûì êîððåêòîðîì 5 dB
Технические характеристики
Диагностическая информация
Внутренний микрокотроллер выдает диагностическую информацию о состоянии.
Диагностическая информация отображается на индикаторе. Значении диагностической информации приведены в
таблице.
Диагностическая информация на индикаторе Комментарии
E1 нет входного сигнала
E2 вне диапазона работы АРУ
E4 перегрев
E3 нет входного сигнала и вне диапазона работы АРУ
E5 перегрев и нет входного сигнала
E6 вне диапазона работы АРУ и перегрев
E7 нет входного сигнала, вне диапазона работы АРУ и перегрев
36
ïåðåêëþ÷àåòñÿ ïðîãðàìíûì ïóòåìpr.
pr.
pr.

Оптические приемники OD001A, OD002
Назначение изделия
Оптические приемники (далее - приемники) конвертируют оптические сигналы в электрические сигналы, усиливают
и распределяют ТВ сигналы в магистральных сетях кабельного телевидения.
Приемники выпускаются со встроенным импульсным блоком питания для питания от сети ~187...250 V и для питания
от источника постоянного напряжения 12...18 V через ВЧ выход (OD001A).
Приемники предназначен работать в закрытом помещении.
Инструкция по электробезопасности
Инсталляция приемников должна быть проведена квалифицированным персоналом в соответствии с
требованиями стандартов электробезопасности.
Приемники питаются опасным для жизни напряжением.
Приемники имеют двойную изоляцию от сети питания ~230V.
Оборудование дистанционного питания приемников должно иметь защиту от короткого замыкания.
Для обеспечения безопасной работы приемников необходимо соблюдать следующие условия:
заземлите корпус приемников перед включением его в сеть;
не включайте приемники в сеть, если шнур или вилка питания повреждены и пока не подключены все
соединения;
розетка питания должна быть легко доступна;
не устанавливайте приемник вблизи приборов отопления;
обеспечьте нормальные вентиляционные условия приемников;
оптический разъем после отключения от сети излучает оптическую радиацию;
не смотрите на луч прямо, лазерный свет может повредить глазам.
Органы управления
Структурная схема
Инсталляция
Приемники должны быть установлены вертикально, кабельными вводами вниз для обеспечения нормальных
вентиляционных условий.
Заземлите корпус приемников проводом не меньше ∅4 mm2.
Инсталляция волоконно-оптического кабеля должна быть сделана очень аккуратно. Радиус загиба волоконно-оптического
кабеля должен быть не меньше 25 mm. Все оптические разъемы и адаптеры перед подключением необходимо очистить.
Конфигурация изготовителя
Изготовителем выставлены следующие значения параметров:
A1 AC
A2 0 dB
Eq 0 dB
При выключении питания информация сохраняется.
Источник питания
Приемники имеют питание от сети переменного тока ~187...250 V через шнур питания. Питание от источника
постояного напряжения 12...18 V через ВЧ выход позволяет легко реализовать функции дистаннционного или
резервирования питания (OD001A).
Управление и регулирование
Параметры устанавливаются кнопками, находящимися на панели приемника. Значения параметров отображаются
на индикаторе.
Кнопки регулирования:
"Mode" - выбрать параметр;
"Value" - заменить значение или наблюдение.
Можно изменять и наблюдать следующие параметры приемников:
1) A1 - первый аттенюатор, значения (в dB): 0; 1; 2...19; 20; AC. AC - автоматическое регулирование усиления (AРУ).
Если эта функция выбрана, выходной уровень будет постоянный, изменяя оптический входной уровень в диапазоне
-7... 2 dBm.
2) A2 - межкаскадный аттенюатор, значения (в dB): 0; 0.5; 1.0; 1.5...9.5; 10.
3) Eq - межкаскадный корректор, значения (в dB): 0; 5; 10.
4) tE - внутренняя температура.
5) OL - мощность оптического входа в dBm, когда индикатор мигает - мощность оптического входа имеет позитивное
значение, если нет - негативное.
45