manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Terra
  6. •
  7. Receiver
  8. •
  9. Terra OD005 User manual

Terra OD005 User manual

Product description
Optical receivers OD005, OD005P (in text – receiver) are intended to convert signals from optical to electrical. Devices
are equipped with Optical Level Control and optical input power indicator as well as bidirectional output test point to simplify
measurement, adjustment and troubleshooting.
OD005P receiver is powered from the mains 230 V~. OD005 receiver is powered from external +6 V DC power supply
unit (PSU) through F-type connector.
Devices are intended for indoor use only.
Suitable for moderate and tropical climates.
Safety instructions
Installation of the receiver must be done according IEC60728-11 and national safety standards.
Any repairs must be done by a qualied personnel.
The OD005P is powered from mains 230 V~. The voltage is dangerous to life.
The OD005 is powered from external +6 V DC power supply unit (PSU) through F-type connector. Output of PSU +6 V
must have a short circuit protection. Follow external PSU safety instructions during installation.
To ensure safe operation of the receivers follow these instructions:
do not remove the cover of the power supply section of OD005P, without disconnecting the unit from the mains supply;
do not plug the receiver into the mains supply if the power cord or plug are damaged;
do not plug the receiver OD005P and the PSU of OD005 into the mains supply until all cables have been connected correctly;
to disconnect the OD005P from the mains completely, disconnect plug from the mains socket;
to disconnect the OD005, disconnect the PSU from mains;
the mains socket must be easily accessible;
receiver shall not be exposed to dripping or splashing water and no objects lled with liquids, such as vases, shall be
placed on it;
avoid placing the receiver next to central heating components and in areas of high humidity;
no naked ame sources, such as lighted candles, should be placed on receiver;
if the receiver has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours before
plugging into the mains;
do not insert any objects into ventilation openings;
the ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, table-cloths,
curtains;
mount the receiver in vertical position with RF connections underneath;
from top, front and bottom of installed receiver must be at least 10 cm free space.
An optical connector after disconnection emits optical radiation.
Avoid looking directly into beam, laser light can cause eye injuries and result in permanent loss of vision.
Optical receivers OD005, OD005P
Draugystes str. 22, LT-51256 Kaunas, Lithuania, tel.: +370 37
-
31 34 44, fax: +370 37
-
31 35 55
E-mail: [email protected], http://www.terraelectronics.com
This product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must be recycled
or discarded according to applicable local and national regulations.
Equipment intended for indoor usage only.
Equipment is double insulated from the mains, with functional earthing.
Functional earthing. Connect to the main potential equalization.
TERRA conrms, that this product is in accordance to following norms of EU: EMC norm EN50083-2, safety norm EN60065 and
RoHS norm EN50581.
TERRA confirms, that this product is in accordance with Custom Union Technical Regulations: “Electromagnetic compatibility of
technical equipment“ CU TR 020/2011, “On safety of low-voltage equipment“ CU TR 004/2011.
Structure diagram
Vers. 1.02
OD005
Technical characteristics
* output level (CTB, CSO) is measured with 8 dB interstage equalizer
Type OD005P OD005
Optical input optical wave lenght 1100-1600 nm
optical input level (AGC range) -6 ...0 dBm
optical return loss > 40 dB
noise current density ≤ 6.5 pA/√Hz
RF output frequency range 47-862 MHz
impedance 75 Ω
return loss ≥ 14 dB at 40 MHz-1.5 dB/octave
frequency response ± 0.75 dB
output level (AGC controlled, 4.9% OMI) 106 dBµV
output level (CTB, EN50083-3)* 107 dBµV (42 ch.)
output level (CSO , EN50083-3)* 107 dBµV (42 ch.)
interstage attenuator 0-15 dB
interstage equalizer 0/4/8 dB
loss in test point -30 ± 0.7 dB
Supply voltage limit values 198-250 V~ 50/60 Hz DC 6 V
Consumption 7 W 0.6 A
Operating temperature range -20o÷ + 50oC
Dimensions/Weight (packed) 135x180x52 mm/0.7 kg 135x120x32 mm/0.34 kg
INSTALLATION INSTRUCTIONS
Read the product description and safety instruction rst.
The receiver should be mounted vertically with cable RF output underneath in order to ensure good ventilation conditions.
The receiver must be xed with steel screws Ø 4-5 mm. The screws are not included in a package.
Fiber installation should be done very carefully. Bending radius of bers must be not less 25 mm. All optical connectors
and adaptors should be cleaned before connecting them.
Plug the receiver into the mains after all cables have been connected correctly.
1. Optical input SC/APC
2. OUTPUT TEST-30 dB -RF output signal test point
(F socket)
3. OUTPUT -RF signal output connector (F socket)
4. Functional grounding clamp
5. 0 / 4 / 8 dB slope switch
6. 0 / 5 / 10 dB gain switch
7. 5 dB ne tuning gain regulator
8. 3 LED optical input power indicator
9. Power cord
10. Screwdriver
11. DC IN
External view
OD005P
Operating and adjusting
Optical level control (OLC) is active at optical input power -6 .. 0 dBm. The output level remains constant (adjusted by user
using discrete 0/5/10 dB switch and ne tuned with 0 .. 5 dB regulator) while optical input power uctuates in range of -6 .. 0 dBm.
The receiver owns optical input power indicator formed from 3 LED. Note the table below for detailed description.
Indication OLC Optical input power
Left LED Middle LED Right LED
Glowing red Not glowing Not glowing OFF < 20 dBm or optical signal is missing
Blinking green Not glowing Not glowing OFF - 20 .. - 6 dBm
Glowing green Not glowing Not glowing ON - 6 .. - 4 dBm
Glowing green Glowing green Not glowing ON - 4 .. - 2 dBm
Glowing green Glowing green Glowing green ON - 2 .. 0 dBm
Glowing green Glowing green Glowing red OFF > 0 dBm
Requirements for external power supply unit
(PSU) for OD005
OD005 is powered from external 6V DC power supply unit.
Requirements:
• Output voltage: 6 V ±5%
• Output current: > 0.7 A
• Output connector: type F, (+) inside
• Short circuit protection
• Double insulated (marked )
• Meet EN 55022 class B conducted emisions requirements,
measuring with grounded load
Power supply
+6 V DC
12 3 4
5
6
7
8
11
5
6
7
8
12 3 4
9
10

This manual suits for next models

1

Other Terra Receiver manuals

Terra OD001A User manual

Terra

Terra OD001A User manual

Terra ORF302 User manual

Terra

Terra ORF302 User manual

Terra OD001A User manual

Terra

Terra OD001A User manual

Terra sdi416 User manual

Terra

Terra sdi416 User manual

Terra OD006 User manual

Terra

Terra OD006 User manual

Terra OD202 User manual

Terra

Terra OD202 User manual

Terra OD012 User manual

Terra

Terra OD012 User manual

Terra OD007H User manual

Terra

Terra OD007H User manual

Terra OT401 User manual

Terra

Terra OT401 User manual

Terra OT301 User manual

Terra

Terra OT301 User manual

Popular Receiver manuals by other brands

Harman Kardon AVR 8000 Service manual

Harman Kardon

Harman Kardon AVR 8000 Service manual

Pioneer X-HM82-S operating instructions

Pioneer

Pioneer X-HM82-S operating instructions

Carlson SS900 Charging Instructions

Carlson

Carlson SS900 Charging Instructions

Rt WOLKS BOX IDL 6650n Web Edition manual

Rt

Rt WOLKS BOX IDL 6650n Web Edition manual

Kenwood TR-2200G Service manual

Kenwood

Kenwood TR-2200G Service manual

USD TV DB2010 operating instructions

USD TV

USD TV DB2010 operating instructions

Motorola DSR-4530 Operator's guide

Motorola

Motorola DSR-4530 Operator's guide

SOMFY 1810872 operating instructions

SOMFY

SOMFY 1810872 operating instructions

Hammarlund HQ-110A Instruction and service information

Hammarlund

Hammarlund HQ-110A Instruction and service information

Hawkeye Mfg Little Pilot manual

Hawkeye Mfg

Hawkeye Mfg Little Pilot manual

Fusion Apollo MS-RA670 installation instructions

Fusion

Fusion Apollo MS-RA670 installation instructions

PCB Piezotronics J320C15 Installation and operating manual

PCB Piezotronics

PCB Piezotronics J320C15 Installation and operating manual

Me BELL-510 RX instruction manual

Me

Me BELL-510 RX instruction manual

Pioneer MVH-S329BT owner's manual

Pioneer

Pioneer MVH-S329BT owner's manual

JVC RX-D301S instructions

JVC

JVC RX-D301S instructions

Sony CX-VX33 Service manual

Sony

Sony CX-VX33 Service manual

LG LHT888 user manual

LG

LG LHT888 user manual

MacroSystem Digital Video Casablanca S-2000 user manual

MacroSystem Digital Video

MacroSystem Digital Video Casablanca S-2000 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.