Test Equipment Depot PS-1303C User manual

CONTENTS
1.INTRODUCTION
2.PRODUCTION MODELS
3.SPECIFICATIONS
3-1 General
3-2 Specifications
4.PANEL CONTROLS AND INDCATORS
a. 30V3A/30V5A/60V3A Front panel
b. 30V3A/30V5A/60V3A Rear Panel
c. 60V5A/30V10A Front Panel
d. 60V5A/30V10A Rear Panel
4-1 Front Panel
4-2 Rear Panel
5.OPERATION INSTRUCTIONS
5-1 Precaution
5-2 Setting Current Limit
5-3 Setting Constant Voltage
6.MAINTENANCE
1
2
3
3
4
6
6
7
8
9
10
11
12
13
11
11
Specifications are subject to change without notice.
6

1.INTRODUCTION
Regulated DC power supply are designed to provide the required in laboratory, university and production lines.
The output voltage is continuously adjustable between 0 to rating voltage. The load currentmay have any
value from 0 to rating current. Voltage and Current are adjusted by means of a coarse and fine potentionmeter.
Both outputs can accurately read on voltmeter and ammeten.
Both stability and ripple are extremely good to meet the requirements of modern circuit design.
The unit can be used as either constant voltage or current source. It has output standby function (optional),
fixed DC 5V/1A output (optional).Four digital LED display (optional).
Overload protection circuits.
1
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com

1
2
3
4
5
6
7
8
0-30V
0-30V
0-30V
0-30V
0-60V
0-60V
0-30V
0-60V
3A
3A
5A
5A
3A
3A
10A
5A
2.PRODUCTION MODELS
Ltem Model Output
Voltage
Output
Current
Output
Standby
Fixed
5V/1A
6. MAINTENANCE
WARNING
The following instructions are for use by qualified personnel only.To avoid electrical shock, do not perform
any servicing other than contained in the operating instruction unless you are qualified to do so.
6-1 lf the fuse blows, the CV or CC indicators will not light and the power supply will not operate. The fuse should
not normally open unless a problem has developed in the unit. Try to determine and correct the cause of the
blown fuse, then replace only with a fuse of the correct rating and type.
The fuse is located on the rear panel.
When line voltage are changed, replade the required fuse shown on page 10
6-2 ln constant voltage mode, if the output voltage is less than presetted
value and CC indicator light, it is over current protection. Unit automatically changed to constant current
mode. Should check the load or increase current set value deponds on the situation.
6-3 ln constant current mode, if the output current is less than presetted value and CV indicator light, the unit
automatically changed into constant voltage mode. Should check the load or increase the presetted voltage
value.
6-4 lf the output voltage is unstableness, please check the AC line it may less than 198V/105V.
2
13
PS-1303C
PS-1303
PS-1305C
PS-1305
PS-1603C
PS-1603
PS-3010
PS-6005

3.SPECIFICATIONS
3-1 General
Main Supply: 110/220V±10 , 50/60Hz Switch selectable (customer optional)
Operation Temperature & Humidity 0 C to 40 C,<80%
Storage Temperature & Humidity -10 C to 70 C,<70%
Accessories
Power cord
Operation Manual
%
1
1
5-3 Setting Constant Voltage
1 Turn the power switch on, the CV indicator light.
2 Rotating the Coarse and Fine voltage control to the desired volts.
3 Press Output standby button, the output standby indicator light, then the terminals have voltage output.
4 For the models which do not have output standby function, the output voltage will supplied cross terminals
immediately after power on.
312
。 。
。 。

3-2 Specifications
0-30V/5A 0-30V/3A
CV≤0.01%+3mV
CV≤0.02%+5mV
CV≤1mV(rms)
300ppm/ C
。
≤0.01%+3mV
≤0.01%+3mV
≤1mV(rms)
CC≤0.2%+3mA
CC≤0.2%+3mA
500ppm/ C
。
≤2mV(rms)
Three LED≤1%+2d
≤100μS
±1%
Model
Constant Voltage Operation
Line regulation
Load regulation
Riple Noise&
Temperature coefficient
Constant Current Operation
Line regulation
Load regulation
Temperature coefficient
Fixed 5V/1A Output:
Voltage accuracy
Riple Noise: CV&
Display accuracy:
Recover time
5. Operation instructions
5-1 Precaution
1 AC input of DC power supply should be within the range of line voltage 220±10% 50Hz.110 5 60Hz
2 To avoid electrical shock, the power cord protective grounding conductor must be connected to ground.
3 Do not use the unit in a place where ambient temperature exceeds 40 C. The heat sink located at rear of
the supply must have sufficient air space for radiation.
4 This unit is a float DC power supply. lf the output have to connected to ground, please short the "+" or -
terminal to "GND" .
5-2 Setting Current Limit
1 Determine the maximum safe current for the device to be powered
2 Temporily Short the"+" and"-" terminals of the power supply togegher with a test lead.
3 Rotated the COARSE VOLTAGE control away from zero sufficiently for the CC indicator to light.
4 Readr the current value on the Ammeten, Adjust the CURRENT control for the desired current limit.
5 The current limit (overload protection) now has been preset. Do not change the CURRENT control setting
after this step.
6 Remove the short lead between the"+" and"-" terminals.
± %
" "
4
11
。
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com

3-2 Specifications (continuance)
Model
Constant Voltage Operation
Constant Current Operation
Line regulation
Load regulation
Riple Noise&
Temperature coefficient
Line regulation
Load regulation
Temperature coefficient
Riple Noise&
Display accuracy:
Recover time
0-30V/10A 0-60V/3A
CV≤0.01%+5mV
CV≤0.02%+5mV
CV≤2mV(rms)
300ppm/ C
。
CC≤0.2%+3mA
CC≤0.2%+5mA
CC≤3mA
500ppm/ C
。
Three LED≤1%+2d
≤100μS
510
0-60V/5A
4-2. Rear panel
17 Power Socket
18 Fuse holder:
19 AC selects switch:
(customer optional)
20 Fan
Fuse rate
30V/3A series: 1.5A 3A
30V/5A series: 3.15A 6.3A
60V/3Aseries: 3.15A 6.3A
60V/5A 6.3A 10A
30V/10A 6.3A 10A
220V 110VA
The power transformer is designed to permit operation in
110V (115V/120V) or 220V(230V/240V),50/60Hz line voltage.
To convert from one line voltage to another is done by change
AC selector as shown in page 8.

VOLTAGE
OUTPUT
LABORATORY DC POWER SUPPLY
POWER
CURRENT
-GND +
C.C. C.V.
5V
- +
ON OFF
FINE
COARSE COARSE
FINE
7 6
16 15 14 13 121
4
11
10
2
5
8
9
3
4-1 Front Panel
1 Power switch: ON/OFF the power
2 Output standby: After power on, there are no voltage cross the terminals.
Press this button, output LED on, unit has power out.Repress this
button, output LED off, output voltage cross the terminals is zero, unit is on
standby mode.
3 Output standby indicator: see above.
4 C.C. indicator: lights when the supply is in the constant current operation.
5 C.V. indicator: lights when the supply is in the constant voltage operation.
6 Voltmeter: lndicates the output voltage.
7 Ammeter: lndicates the output current.
8 Voltage Coarse: for coarse adjustment of the output voltage.
9 Voltage Fine: for fine adjustment of the output voltage.
10 Current Coarse: for coarse adjustment of the output current.
11 Current Fine: for fine adjustment of the output current.
12 " +" Output terminal: positive polarity
13 "GND" terminal: earth and chassis ground
14 "-" Output terminal: negative polarity
15 Fixed 5V/1A "+ " output terminal
16 Fixde 5V/1A"-"output terminal
6
9
4. PANEL CONTROLS AND INDICATORS
a
.30V3A/30V5A/60V3A Front panel: b
.30V3A/30V5A/60V3A Rear Panel:
110 V
22 0V
19
17
18

78
110V
22 0V
19
17
18
20
.60V5A/30V10A Rear Panel lndicator
cd
114 13 12
COARSE
4POWER
ON OFF
3
10
FINE
-
CURRENT
C.C.
COARSE
VOLTAGE
76
5
9
8
ON/OFF
OUTPUT
11
2
FINE
C.V.
GND +
.60V5A/30V10A Front Panel Controls and lindicator:
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com
This manual suits for next models
7
Table of contents
Other Test Equipment Depot Power Supply manuals