Congratulations..............................................................
Safety Warnings..............................................................
Line Drawing Key...........................................................
TidalFit Conguration and Water Capacities...............
Electrical Requirements and Installation.....................
Basic System Features and Functions...........................
60 Hz Electrical Wiring...........................................
50 Hz Electrical Wiring...........................................
TidalFit Start Up..............................................................
Selecting a Location..............................................
Inspection..............................................................
Filling the Pool with Water......................................
Turning the Power On............................................
Verifying Water Circulation.....................................
Testing the GFCI Breaker......................................
Priming the Pump..................................................
Water Preparation.................................................
ML 700 Panel User Guide..............................................
Diagnostic Messages.....................................................
Various Exercises..........................................................
Rowing Exercise....................................................
Upper Body Exercise.............................................
Treadmill/Advanced Swimming.w/Superswim.......
1
3
5
6
7
8
9
11
12
12
13
13
14
14
14
15
15
16
25
30
31
32
33
33
33
34
35
36
36
37
37
38
39
40
40
Maintaining Your TidalFit...............................................
Draining Your Pool................................................
Pillow Care............................................................
Jet Care................................................................
Removing, Installing, and Cleaning Filters...........
Winterizing Your Pool............................................
Replacing the Light Bulb.......................................
Pool Cabinet Care.................................................
Cleaning Your Pool Interior....................................
Cover Care...........................................................
Chemical Treatment of Water...............................
Water Chemistry............................................................
Water Treatment Glossary....................................

TABLE OF CONTENTS cont....
Spa Chemicals Glossary..........................................
Maintaining the Proper pH....................................
Warranty Information....................................................
Interior Pool Diagram...................................................
45
46
47
53

1
Before you do anything else, make sure you
register your new TidalFit exercise pool.
Congratulations...
Congratulations on the purchase of your new TidalFit. We know
you will enjoy your TidalFit. Not only will your TidalFit be a physical
workout, but also it will be relaxing and fun. We believe this
will be an indispensable part of a healthy lifestyle. The TidalFitl
lifestyle is one that encourages health and well-being.
Owning a TidalFit brings some responsibility. With proper care,
your TidalFit will provide years of enjoyment and therapy for your
family and friends. Please take time to read and understand all of
the instructions provided before you install your TidalFit exercise
pool. This owner’s manual is meant to be a supplement to the
training you should receive from your dealer when you purchase
and start up your TidalFit for the rst time.
Please remember your TidalFit is a powerful piece of electrical
equipment. It is extremely important that you have it properly
installed to ensure safe use. This manual explains safety
precautions, installation instructions, and operating and
maintenance procedures. If you have any questions regarding
this manual, please call your competent dealer, who will be
happy to further assist you.

For your future reference and convenience, please record the Se-
rial and Model number along with the installation date in the spaces
provided below. STORE THIS MANUAL WHERE YOU CAN EAS-
ILY FIND IT WHEN NEEDED. The serial and model numbers are
mounted on the base of the equipment enclosure area, as shown
below.
Spa Serial Number_____________________________________
Spa Model Number_____________________________________
Spa Installation Date____________________________________
Dealer Name, Address, and Telephone Number
____________________________________________________
____________________________________________________
____________________________________________________
Diagram of Where to Find Serial Number
2
Serial Number Information

3
PLEASE TAKE THE TIME TO READ ALL OF THESE WARNINGS AND
CAUTIONS PRIOR TO USING YOUR POOL
PLEASE, be a responsible TidalFit owner. When installing and using this
pool, always adhere to basic safety precautions. Be sure to list emergency
telephone numbers at the telephone nearest the pool, including physician,
hospital, ambulance, police, and the re department. Be certain to explain
safety precautions to all new or occasional users of your pool. Remember,
they may not be aware of the possible risks associated with the pool water
temperature.
Have at least one family member learn CPR (cardiopulmonary resuscita-
tion). IT COULD SAVE A LIFE!
1. READ AND FOLLOW ALL INSTRUCTIONS!
2. WARNING - To reduce the risk of injury, do not permit children to use
this product unless they are closely supervised at all times.
3. A wire connector is provided on this unit to connect a minimum 8 AWG
(8.4 mm ) solid copper conductor between this unit and any metal
equipment, metal enclosures of electrical equipment, metal water pipe, or
conduit within 5 feet (1.5 m) of the unit.
4. DANGER - Risk of Accidental Drowning - Extreme caution must be
exercised to prevent unauthorized access by children. To avoid accidents,
ensure that children cannot use this spa unless they are supervised at all
times.
5. DANGER - Risk of Injury - The suction ttings in this area are sized
to match the specic water ow created by the pump. Should the need
arise to replace the suction ttings or the pump, be sure the ow rates are
compatible.
Never operate spa if the suction ttings are broken or missing. Never re-
place a suction tting with one rated less than the ow rate marked on the
original suction tting.
6. DANGER - Risk of Electrical Shock - Install at least 5 feet (1.5 m) from
all metal surfaces. As an alternative, a spa may be within 5 feet of metal
surfaces if each metal surface is permanently connected by a minimum 8
AWG (8.4 mm ) solid copper conductor to the wire connector on the ter-
minal box that is provided for this purpose.
7. DANGER - Risk of Electric Shock - Do not permit any electrical appli-
ance such as a light, telephone, radio, or television, within 5 feet (1.5 m)
of a spa.
SAFETY WARNINGS

SAFETY WARNINGS cont...
8. WARNING - To reduce the risk of injury:
a) The water in a pool should never exceed 40ºC (104ºF). Water temper-
atures between 38ºC (100ºF) and 40ºC are considered safe for a healthy
adult. Lower water temperatures are recommended for young children
and when pool use exceeds 10 minutes.
b) Since excessive water temperatures have a high potential for causing
fetal damage during the early months of pregnancy, pregnant or possibly
pregnant women should limit pool water temperatures to 38ºC (100ºF).
c) Before entering pool, the user should measure the water temperature
with an accurate thermometer since the tolerance of water temperature
regulating devices varies.
d) The use of alcohol, drugs, or medication before or during pool use may
lead to unconsciousness with the possibility of drowning.
e) Obese persons and persons with a history of heart disease, low or high
blood pressure, circulatory system problems, or diabetes should consult a
physician before using a pool.
f) Persons using medication should consult a physician before using pool
since some medication may induce drowsiness while other medication
may affect heart rate, blood pressure, and circulation.
AUDIO COMPONENT WARNINGS
If pool is equipped with Audio system you should follow these guide-
lines for safety:
1. CAUTION - Risk of Electrical Shock - Do not leave compartment door
open.
2. CAUTION - Risk of Electrical Shock - Replace components only with
identical components.
3. Do not operate the audio controls while inside the pool.
4. WARNING - Prevent Electrocution - Do not connect any auxiliary
components (for example cable, additional speakers, headphones, ad-
ditional audio/video components, etc.) to the system.
5. These units are not provided with an outdoor antennae; when provided,
it should be installed in accordance with Article 810 of the National Electri-
cal Code, ANSI/NFPA 70.
4

6. Do not service this product yourself as opening or removing covers
may expose you to dangerous voltage or other risk of injury. Refer all ser-
vicing to qualied service personnel.
KEEP THESE SAFETY INSTRUCTIONS IN A CONVENIENT AND
READILY ACCESSIBLE LOCATION!!
5
LINE DRAWING KEY
Name of Component Symbol for Component
Line Drawing may not be exact model of your particular spa.
Certain options may be shown that are not included on your spa.
7” Jumbo Storm Massage W / ESC
Ozone Jet
3” Helix Roto W /ESC
5” Helix MSSG W / ESC
5” Helix Direct W / ESC
2” Helix Direct

CONFIGURATION AND WATER CAPACITY
TidalFit
Volume 1715 gal 7554 l
Weight (dry/lled) 2000 / 16,303 lbs 907 / 7,395 kg
Dimensions 168x91x52in 427x231x132 cm
Control CE SWIM SPA CE SWIM SPA
Heater 4kW in.THERM 4kW in.THERM
Circulation System Hi-Flo Standard Hi-Flo Standard
Ozone CD CD
Cartridge Filter 2 2
Disposable Filter 1 1
Cascade Standard Standard
6

7
ELECTRICAL REQUIREMENTS
AND INSTALLATION
The following information is provided for hooking up electrical supply to
your new pool. A qualied, licensed, electrician must perform this work.
Failure to follow these instructions will terminate all warranty coverage
and can cause serious injury or death.
Your 60Hz pool is preset at the factory to run on 240V with a 48 amp
input. This feature gives you the most performance out of your pool.
This will require a 240V, 60-amp GFCI
Your export 50Hz pool is preset out of factory to run 230V-240V 3 wires
30 amp max input. This product must always be connected to residual
current device (RCD) having a trip current of not more than 30 mA.
ELECTRICAL WIRING
WARNING: Your pool must be wired by a certied electrician and
according to these instructions. Failure to do so will terminate all
warranties and all listings from the independent listing facility.
1) The TidalFit requires a 240 VAC dedicated system. The pool must be
hard wired to the power supply, with no plug-in connections, extension
cords, or sharing of service.
2) The pool requires that you run 6 (10 mm²) or 8 (8.4 mm²) AWG cop-
per wire, depending on the GFCI size. Do Not Use Aluminum Wire.
3) The power supply must have a suitable Ground Fault Circuit Inter-
rupter (GFCI), according to Section 422-20 of the National Electrical
Code, ANSI/NFPA 70-7987 or other national installation requirement
with a residual current device (RCD) having a trip current of not more
than 30 mA. This could be used as the shut-off switch, which must be
installed in plain view of the pool. This electrical service must be readily
accessible to the pool occupants, but must not be within 5 feet of the
pool.
4) Use only non-metallic conduit and ttings when installing power to
the spa.
5) After your pool has been positioned, route lines through the knockout
on the left or right front corner of the pool.
6) Connect the power to the pool.

8
Basic System Features and Functions
Main Board Power Requirements (60Hz)
240VAC, 48A, Class A GFCI-protected service (Circuit Breaker
rating = 60A max.)
4 wires (hot, hot, neutral, ground)
Auxiliary Heater Power Requirements (60 Hz)
240VAC, 60Hz, 24A, Class A GFCI-protected service (Circuit
Breaker rating = 30A max.)
4 wires (hot , hot, neutral, ground.)
•
•
•
•
Main Board Power Requirements (50Hz)
Single Service {3 wires (line, neutral, ground)}
230VAC, 50Hz, 1 - ,16A/32A, (Circuit Breaker rating = 20A/40A
max.
Dual Service {5 wires (line 1, neutral 1, line 2, neutral 2,
ground)}.
230 VAC,, 50Hz, 1 -, 2x 16A, Circuit Breaker rating = 20 max
each service.)
3-Phase Service [5 wires (line 1, line 2, line 3, neutral, ground)]
400VAC, 50Hz, 3N -, 16A, (Circuit Breaker rating = 20A max
each phase line.)
IMPORTANT - Service must include a neutral wire, with a line to
neutral voltage of 230VAC.
Auxiliary Heater Board Power Requirements
Single service {3 wires (line, neutral, ground)}
230VAC, 50Hz, 1 -, 24A, (Circuit Breaker rating = 30A max.)
•
•
•
•
•
•
•
•
•

9
60Hz GFCI WIRING DIAGRAM

10
1) The black and red wires from the main electrical box* must be con-
nected to the input lugs in the GFCI.
2) The white wire from the main electrical box* must be connected to the
dedicated neutral bar inside the GFCI box.
3) The green or copper wire from the main electrical box* must be con-
nected to a separate dedicated ground bar inside the GFCI box.
4) The red and white wires from the pool connect to the GFCI breaker
output terminals.
5) The white wire from the pool must connect to the center load terminal
ON THE GFCI BREAKER, usually behind the white pig-tail on the breaker
itself
6) The white pig-tail from the GFCI breaker must connect to the dedicated
ground bus inside the GFCI breaker box.
7) The green or copper wire from the pool must connect to the dedicated
ground bus inside the GFCI box.
*Main electrical box refers to the house distribution panel and not the
GFCI
Pack Terminal Block from GFCI
MUST BE DONE BY A CERTIFIED ELECTRICIAN
50Hz Electrical Service Conguration Options
For DIP Switch Congured
System
Single Service (1 x 16 Amp
or 1 x 32 Amp)
This option is congured and
shipped as the default.
For 1 x 32 Amp Service:
DIP Switch A2 can be ON
For 1 x 16 Amp Service.
DIP Switch A2 must be OFF

50Hz Electrical Service Conguration Options
cont’d..
11
Dual Service Option (2 x
16 Amp)
Completely remove the
white wire from J26 and
J32.
Note: J32 and J23 are
electrically identical.The
white wire may be at-
tached to either terminal
before removal.
DIP Switch A2 must be
ON.
Completely remove the blue wire from J28
and J57.
Note: J57, J58 and J59 are electrically identical. The blue wire may be
attached to any of these terminals before removal.
Move the brown wire from J23 or J32 to J28.
DIP Switch A2 must be ON
DIP Switch A2 must be ON.
Move black wire from J27 to J53.
3 Phase Service Option
IMPORTANT - Service
MUST include a neutral
wire, with a line to neutral
voltage of 230VAC.
Completely remove the
white wire from J 26 and
J 32
Note: J32 and J23 are
electrically identical. The
white wire may be at-
tached to either of these
terminals before removal.

TidalFit START-UP
Please read each step of the Start-up section prior to doing the
step.
SELECTING A LOCATION
In preparation for installing your new TidalFit, you should ensure that
your chosen location meets some minimum guidelines:
1) Place your TidalFit on a surface that is large enough for the entire Tidal-
Fit to t. Consider the space needed to easily access equipment compart-
ments and circuit breakers. Remember, all electronics must be kept dry.
2) The TidalFitl must be on a solid, level foundation. Recommended: 4
inches of cement slab that has cured for at least 72 hours. Your warranty
will be voided if the TidalFit is not properly installed. Structural damage
due to an improper foundation is not covered under warranty.
3) To avoid potential water damage to the skirt and frame, your TidalFit
should be placed on a site where it will not be in the way of water sprin-
klers.
(4) OUTDOOR POOL: Consider building codes, electrical and plumbing
codes, desired proximity to house, wind and sun exposure, location of
trees (falling leaves, shade), dressing area, landscaping and lighting when
selecting a location.
5) INDOOR POOL: Floor surface must have traction to prevent slipping
when wet. A oor drain is optimum. As room humidity will increase be-
cause of the spa, provide ample ventilation to prevent dry rot, mildew and
mold. Use materials that will withstand humidity. There may be a need for
cross-ventilation fans and/or dehumidiers. The spa chemicals may cor-
rode some household metals. Provide ample room if servicing should be
needed. Strong foundational support is vital, particularly if a second-story
site is selected.
6) Ensure the equipment compartment is in a location where it will not
be damaged by water drainage. Cover the equipment compartment with
a heavy screen if rodents are a problem. Damage due to rodents is not
covered under warranty.
7) Have the pool deck installed by a knowledgeable contractor to ensure
proper support.
12

13
8). If the TidalFit is placed on the ground, even for a short period of time,
it must be supported by stones that are at least 2 inches thick and 12
inches square. A solid foundation is recommended as soon as pos-
sible.
INSPECTION
You will want to inspect your TidalFit, prior to lling it up with water. Look
for and remove any debris in the pool tub and in the lter. Verify that
pump plugs are installed on the pumps and the pump unions are tight.
FILLING THE TidalFit WITH WATER
NOTE: DO NOT ll your TidalFit with hot water straight out of your
water heater or tap. This water may be as hot as 180ºF and will
cause damage to the surface and plumbing of the pool. This will
void your warranty. Level the pool before lling.
1) Prepare to ll the tub by removing all debris.
2) Remove the lters from your pool (see Removing, Installing and
Cleaning Filters, page 35.)
3) Place your garden hose in the center of the lter .
4) Fill the tub from the circulation pump line until water level is above
the foot-well.
Note: This will purge all the air out of the circulation pump. An air
lock can cause damage to the circulation pump and is not covered
under warranty.
5) Once the water level is lled over the foot-well, you can pull the hose
out of the lter line and continue lling the pool from the lter well.
6) Fill the pool to the bottom of the pillows. Note: DO NOT OVER-FILL
YOUR POOL!
7) With the front panel off, verify there are no leaks at the pump union.
Note: Pump unions can become loose during shipping. Verify that
there are no leaks during lling of the pool.
8) Reinstall the circulation pump screen and all lters.

14
TURNING THE POWER ON
Turn the power to the pool on at the main circuit breaker. Verify that
your pool has no error codes. Verify that there is good water circulation
in the pool. The pumps will come on in cycles, for 1 minute each cycle.
VERIFYING WATER CIRCULATION
1) Open all the jets.
2) Press the Pump 1 key to turn the pumps on or off.
3) Make sure each seat has water ow. Note: On certain pools there is
a diverter valve. Verify where the diverter valve is located.
TESTING THE GFCI BREAKER
NOTE: The electrical service panel for your pool should be equipped
with a GFCI breaker. To avoid the risk of electrical shock, perform the
following safety test before each use of your pool.
1) Make sure the power is turned on at the electrical service panel.
2) Turn on the GFCI breaker. If the breaker stays on, it is functioning
properly.
DANGER: RISK OF ELECTRICAL SHOCK
If the GFCI breaker fails to operate as described, there is a possibility of
an electrical shock if the TidalFit is used. Shut off the power at the main
electrical service panel until the source of the problem has been identi-
ed and corrected by a licensed electrician or qualied pool technician.

15
Tidal Fit START-UP cont...
TESTING THE GFCI BREAKER cont...
NOTE: When power is turned on, your pool is automatically programmed
to start circulating water through the circulation pump. Each pump and/
or blower will come on consecutively for approximately 1 minute to au-
tomatically purge the system. Adjust your temperature by pressing the
up button on your touch pad until the desired temperature is displayed.
This setting will allow your pool to heat to the set temperature.
CAUTION: If water is not noticeably coming from your pool jets during
the automatic purge, turn on the high speed pump. If water is still not
coming from the jets, the pump needs to be manually primed, following
the steps below.
PRIMING THE PUMP
1) Turn off power at electrical service panel.
2) Locate and loosen one of the pump plugs on each pump by turning it
counterclockwise one half of one turn.
3) Allow air to escape from ttings. When a steady stream of water ows
from the pump plug, close it by turning it clockwise until tight.
4) Turn on power at electrical service panel.
5) Check once more to make sure that water is owing from the jets dur-
ing auto purge. If so, continue. If no water is coming from your spa jets,
please call your Artesian dealer for further assistance.
WATER PREPARATION
NOTE: Before putting your new pool into operation, understand that
preparing your new water is an important part of maintenance. Failure
to properly prepare your water can result in substantially decreasing
the life of the components and may void your warranty in severe cases.
Your Artesian dealer should have a start-up and maintenance kit avail-
able for you when you receive your pool.

ML700 PANEL USER GUIDE
.
Initial Start-up
When your pool is rst actuated, it will go into Priming mode (after dis-
palying some conguration information). Please see the M-7 Installa-
tion Instruction Manual for complete instructions on Power-up and
Pump Priming. The Priming mode will last for up to 4 minutes and then
the pool will begin to heat and maintain the water temperature in the
Standard mode. You can exit Priming mode early by pressing “Warm” or
“Cool”.
Icon Legend
Heat Icon - Indicates different stages of heating.
Jets Icon - Spins fast on high speed; spins slow
On low speed
Blower Icon - Biggest in highest speed; smallest
In lowest speed.
16