TILLQUIST P30U User manual

1
1
TRANSDUCER
OF TEMPERATURE
AND STANDARD SIGNALS
P30U
USER’S MANUAL

2
2

3
3
Contents
1. APPLICATION........................................................................ 6
2. TRANSDUCER SET.................................................................. 8
3. BASIC REQUIREMENTS, OPERATIONAL SAFETY .............................. 8
4. INSTALLATION ...................................................................... 9
4.1. Mounting method ............................................................. 9
4.2. External connections diagrams............................................ 10
5. OPERATION......................................................................... 11
5.1. P30U transducer front panel description................................. 11
5.2. Messages after switching on the power.................................. 12
5.3. Key functions ................................................................. 13
5.3.1. Individual key functions................................................ 13
5.3.2. Functions of key combinations........................................ 15
5.3.3. Programming matrix.................................................... 16
5.4. Programming transducer parameters .................................... 17
5.4.1. Changing the value of the selected parameter ..................... 22
5.4.2. Changing floating-point values ....................................... 22
5.4.3. Programmable transducer parameters ............................. 23
5.5. Transducer functions ........................................................ 40
5.5.1. Measurement input ..................................................... 40
5.5.1.1. Interface RS-485 Master mode................................... 40
5.5.1.2. Interface RS-485 Monitor mode.................................. 43
5.5.1.3. Median filter ........................................................ 44
5.5.1.4. Averaging time...................................................... 46
5.5.1.5. Maximum and minimum values of measured signals ........ 46

4
4
5.5.1.6. Mathematical operations on measured values ................ 46
5.5.1.7. Mathematical functions ........................................... 48
5.5.1.8. Input individual characteristic ................................... 48
5.5.1.9. Displayed value range limitation ................................ 50
5.5.2. Analog output ........................................................... 50
5.5.2.1. Analog output individual characteristic ......................... 50
5.5.2.2. Analog output overflow management ........................... 51
5.5.3. Alarm and power outputs ............................................. 55
5.5.4. LCD display .............................................................. 57
5.5.4.1. Custom unit definition ............................................. 59
5.5.4.2. Displaying two values with their units .......................... 60
5.5.5. Writing and reading transducer configuration from file........... 61
5.5.5.1. Storing the transducer configuration file ....................... 61
5.5.5.2. Reading the transducer configuration file ...................... 61
5.6. Default settings .............................................................. 62
5.7. Firmware update............................................................. 67
5.8. Archiving measured values ................................................ 69
5.8.1. Transducer memory structure ........................................ 69
5.8.2. Internal memory ........................................................ 70
5.8.2.1. Record structure ................................................... 71
5.8.2.2. Downloading archived data from the internal memory....... 72
5.8.3. Archiving configuration ................................................ 73
5.8.4. Memory card or internal file system memory (option)............ 76
5.8.5. Archive file structure ................................................... 79
5.9. RS-485 Interface ............................................................. 80
5.9.1. Serial interface connection........................................... 80

5
5
5.9.2. MODBUS protocol description ........................................ 81
5.9.3. Description of the implemented functions .......................... 82
5.9.4. Register map ............................................................ 86
5.9.5. Read and Write registers .............................................. 89
5.9.6. Read-only registers................................................... 110
5.10. 10/100-BASE-T Ethernet interface ..................................... 117
5.10.1. Connecting 10/100-BASE-T Ethernet interface .................. 117
5.10.2. WWW server ......................................................... 119
5.10.2.1. Website general view .......................................... 120
5.10.2.2. WWW user selection ........................................... 120
5.10.3. FTP server ............................................................ 122
5.10.3.1. FTP user selection .............................................. 122
5.10.4. TCP/IP Modbus....................................................... 124
6. ACCESSORIES.................................................................... 125
7. ERROR CODES ................................................................... 125
8. TECHNICAL DATA................................................................ 127
9. ORDERING CODE ................................................................ 132

6
6
1. APPLICATION
The P30U programmable transducer is designed to convert
temperature, resistance, direct voltage and direct current signals into
a standard DC voltage or DC current signal. The output signal is galva-
nically isolated from the input signal and power supply. The transducer
is tted with a 2x8 LCD screen.
Features of the P30U transducer:
•converting measured values into any output signal based
on an individual linear characteristic,
• calculating measured values using one of ve implemented
mathematical functions,
• calculating measured values based on a 21-point individual
characteristics,
•one or two NO (normaly open) relay alarms operating in 6 modes
• auxiliary power supply 24V DC 30mA switched on/off by software
(options),
• indication of exceeding the alarm values set,
•programming alarm and analog outputs with a reaction to selected
input value (main input, auxiliary input or RTC),
• real time clock (RTC) with independent battery supply
•recording the input signals in programmed time periods in the inter-
nal memory and on an SD/SDHC card (option),
• internal archive memory with 534336 record capacity,
•automatic decimal point setting,
•preview of preset parameters,
•password protected parameter change
• RS-485 interface support with the MODBUS protocol in RTU mode,
•programmable averaging time,
• Median lter with various number of samples
• SD/SDHC memory cards support – compatible with FAT and FAT32
le system (option),
• RS-485 interface Master mode – ability to poll a single slave device

7
7
• RS-485 interface Monitor mode – ability to monitor transmission
on RS-485 interface and react to the value of the selected register.
• 10/100 BASE-T Ethernet interface (option)
• protocol: Modbus TCP/IP, HTTP, FTP,
• services: WWW server, FTP server, DHCP client

8
8
2. TRANSDUCER SET
- P30U transducer 1 pc.
- user’s manual 1 pc.
- guarantee card 1 pcs.
- plug-able screw terminal blocks 4 pcs.
3. BASIC REQUIREMENTS,
OPERATIONAL SAFETY
The transducer meets the requirements of EN 61010-1 standard
in terms of operational safety.
Safety precautions:
•The assembly and installation of electrical connections must be
carried out by a person authorized to install electrical equipment.
• Before switching the transducer on, one must check the correct-
ness of connections.
•The device is destined to be installed and used in industrial electro-
magnetic environment conditions.
•The building installation should be equipped with a switch
or an automatic circuit breaker located near the device,
which should be easy accessible by the operator and properly
marked.
• Removal of the transducer housing during the warranty period
may cause its invalidation.

9
9
4. INSTALLATION
4.1. Mounting method
P30 transducers should be mounted on a 35 mm rail bracket
according to PN-EN 60715. Dimensions and method of mounting are
shown in gure 2.
Fig.2. Overall dimensions and method of mounting
the transducer.
Lock

10
10
4.2. External connections diagrams
Fig.3. External connections diagram of the P30U transducer
For the connection of input signals in environments with a high noise
level, shielded wires should be used.

11
11
5. OPERATION
5.1 P30U transducer front panel description
Fig.4. Front panel description
Note: The memory card (option) should be inserted to the transducer
slot with contacts facing down
LED indicator description:
RX – green diode – Data reception on RS-485 indicator
TX – yellow diode – Data transmission on RS-485 indicator
P30U P30U
LED
indicator
Increase
value key
Change
value key
SD/SDHC
memory card
Power
indicator
Result
Unit
Cancel key
Accept key
LED
indicator
Increase
value key
Change
value key
Power
indicator
Result
Unit
Cancel key
Accept key
RJ45 port
(Ethernet)

12
12
M – red diode – full internal memory indicator or writing le
to SD/SDHC memory indicator, when the internal
memory usage exceeds 95%, the diode is
constantly on, if the transducer operates
with an installed memory card, then the LED ashes
when data is being written on the card.
A1 – red diode – indicator of switching on the rst alarm
A2 – red diode – indicator of switching on the second alarm
or 24V d.c. power supply
Power indicator – green diode.
5.2. Messages after switching on the power
After connecting external signals and switch the power supply
on which is signalled with a green LED (power indicator), the transdu-
cer displays the type, current firmware version and the serial number.
If the transducer is equipped with Ethernet interface (P30U-X2XXXXXX)
IP address is displayed after serial number (stored in memory or recei-
ved from the DHCP server).
Fig.5. Fig.5. Start-up messages of a transducer not equipped
with an Ethernet interface.
Fig.6. Start-up messages of a transducer equipped with an Ether-
net interface.

13
13
5.3. Key functions
5.3.1. Individual key functions
- accept key
•enters programming mode (hold for about 3 seconds),
• navigates the menu – level select,
•enters parameter value change mode,
•accepts the changed parameter value,
•changes the content displayed in the lower line of the display,
•switching the transducer power supply on while holding this key
enters the software update mode through the RS-485 interface,
connection parameters: rate 9600 kb/s, mode 8N2.
- increase value key
• displays the maximum value of the main input,
•enters the parameters group level,
•navigates the selected level
• changes the value of a selected parameter – increase value,
After about ve seconds, the transducer automatically
switches to operating mode; it makes a measurement and converts it
into an analog output signal. It displays the measured value in the top
row of the display and auxiliary information in the bottom row of the dis-
play (section 5.5.4). The LED indicator signals the transmission status
on the RS-485 interface, status of the internal memory use and alarm
states. If transducer is equipped with an Ethernet interface, Ethernet
services start-up: WWW server, FTP server, TCP/IP Modbus

14
14
- change digit key
•displays the minimum value of the main input,
•enters the parameters group level,
•navigates the selected level,
• changes the value of a selected parameter – switches to the sub-
sequent digit,
•switching the transducer power supply on while holding this key
enters the software update mode through the RS-485 interface,
connection parameters: rate 15200 kb/s, mode 8N2.
- cancel key
•enters the transducer parameters preview menu (hold for about
3 seconds),
• exits the transducer parameters preview menu,
•changes the content displayed in the lower line of the display,
•cancel the parameter change,
•completely cancels the programming mode (hold for about
3 seconds).
•switching the transducer power supply on while holding the key
forces reading transducer con guration from P30U_PAR.CON le
stored on an external SD/SDHC memory card or in the internal le
system memory (depending on the manufacturing variant).

15
15
5.3.2. Functions of key combinations
- hold for about 3 seconds
•clear alarm indication; this action works only when the alarm
indication memory function is switched on;
- hold for about 1 second
• clears the maximum value for the measured value
- hold for about 1 second
•clears the minimum value for the measured value
- hold for about 1 second
• unmounts the SD/SDHC memory card enabling safe removal –
for transducer equipped with an external SD/SDHC memory slot
- hold for about 1 second
•force start copying the archive from the internal memory into
the SD/SDHC memory card– for transducer equipped with
an external SD/SDHC memory slot
•force start copying the archive from the internal memory
to the le system memory – for transducer equipped
with an Ethernet interface; this action enables downloading
current archive data les from the transducer via FTP protocol
Push and hold the programming key for about
3 seconds to enter the programming matrix. The programming matrix
can be protected with a safety code.

16
5.3.3. Programming matrix
Fig.7. P30U operation algorithm
Tr
ansducer
parameters
preview menu
preview menu
Displa
y
max. value
3 seconds
3 seconds
Displa
y
min. value
Enter
passw
or
d
Check
ing
the passw
or
d
Ente
r
programming
mode
correc
t
incorre
ct
Displa
y
message
Erase
min. value
Erase
max. value
Clear alarm
memor
y
Unmount memor
y
card (only transducer
variants equipped
with SD/SDHC slot)
W
rite internal archiv
e
into the SD memor
y
or internal le sy
stem
memor
y
MEASUREMENT

17
5.4. Programming transducer parameters
Press and hold for about 3 seconds key
to enter the programming matrix. If access is password protected,
transducer will ask for password. If the entered password is incorrect,
Err.Code message will be displayed. Correct password enables
access to the programming matrix. Fig. 8 shows the matrix
in the programming mode. Use or to select
the menu level or navigate the parameters of a given sub-level.
The parameter symbol is displayed at the upper line of the display,
while the parameter is displayed at the lower line of the display.
Press to edit parameter. Press to cancel changing
parameter. Press and hold to exit the programming matrix
and enter the measurement mode. If the transducer remains inactive
for 30 seconds in the parameter programming mode, it will exit the pro-
gramming mode and display the displayed value.

18
18
Settings
Input
Input
parameters
Input
Measured
value type
AvgTime
Averaging
time
Compens.
Compensa-
tion type
Comp.Val
Manual com-
pensation
value
Median
Number
of median
lter
samples
Settings
Ind.Char
Individual
charac-
teristic
parameters
Point No
Number of
individual
char.points
X1
The rst
point of the
individual
char.
Point x
Y1
The rst
point of the
individual
char. Point y.
….
X21
The last point
of the individual
char.
Settings
Display
Display
parameters
DecimalP
Minimum
decimal
point of the
displayed
value
Unit
Displayed
unit
Over Lo
Lower
display range
threshold
Over Hi
Upper
display range
threshold
Bcklight
Display back-
light time
Settings
Alarm 1
Alarm 1
parameters
Param.A1
Input value
type for
alarm 1
Type A1
Alarm 1 type
OverLoA1
Alarm 1
lower thres-
hold
OverHiA1
Alarm 1
upper thres-
hold
DlyOnA1
Alarm 1 acti-
vation delay
Settings
Alarm 2
Alarm 2
parameters
Param.A2
Input value
type for
alarm 2
Type A2
Alarm 2
type
OverLoA2
Alarm 2
lower
threshold
OverHiA2
Alarm 2
upper
threshold
DlyOnA2
Alarm 2
activation
delay
Settings
Output
Analog
output
parameters
Param.An
Value which
controls
analog
output
AnIn Lo
Low level
input signal
AnIn Hi
High level
input signal
AnOut Lo
Low level
output signal
AnOut Hi
High level
output signal

19
19
Math Fun
Mathematical
function on
measured
value
Y21
The last point
of the indivi-
dual char.
Bckl.Int
LCD display
backlight
intensity
Disp.Reg
Number
of register
displayed
at the lower
line of the
display
Dec.P 2
Minimum
decimal
point of
the second
displayed
value
Unit2
Second
displayed
value unit
DlyOffA1
Alarm 1
deactivation
delay
OnLockA1
Alarm 1
reactivation
delay
SgKeepA1
Alarm 1
indication
mode
DlyOffA2
Alarm 2
deactivation
delay
OnLockA2
Alarm 2
reactivation
delay
SgKeepA2
Alarm 2
indication
mode
OverServ
Over ow
management
activation
OvrIn Lo
Lower input
over ow
OvrIn Hi
Upper input
over ow
OvrOutLo
Value
expected
on output at
input lower
over ow
OvrOutHi
Value expected
on output at input
upper over ow

20
20
Settings
Mbus 485
RS-485
interface
parameters
Address
Device
address
ModeUnit
Transmis-
sion frame
mode
BaudRate
Transmission
rate
Base.Reg
Number of pol-
led/monitored
base register
in Master/Mo-
nitor mode
No.ofVal
Number of
polled values
in Master /
Monitor mode
No.OfErr
Number of
acceptable
errors in
Modbus RS-485
answers
Settings
Archive
Archiving
parameters
Arch.Val
Archived
value
selection
Param.Ar
Value type
triggering
conditional
archiving
Ar. Mode
Archiving
type
OverLoAr
Archive lower
threshold
OverHiAr
Archive upper
threshold
Settings
Service
Service
parameters
Fabr.Par
Write
standard
parameters
Security
Enter
password
Time
Set current
time
Date
Set current
date
AutoTime
Auto change
of summer/
winter time
Settings
Ethernet
Ethernet
parameters
DHCP
DHCP client
on/off
addrIP32
B3,B2
byte of IP
address
(IPv4)
addrIP10
B1,B0 byte
of IP address
(IPv4)
mask 32
B3,B2 byte of
subnet mask
maska 10
B1,B0 bajt
maski pod-
sieci
received from DHCP or entered manually when DHCP is off,
AddrmTCP
Device
address for
TCP/IP Mod-
bus service
PortMbus
TCP/IP
Modbus
port
TimeMbu
TCP/IP
Modbus
service close
time when
inactive
no.c.TCP
Number
of allowed
simultaneous
connections
with TCP/IP
Modbus
service
p.comFTP
FTP server
command port
number
Table of contents
Other TILLQUIST Transducer manuals
Popular Transducer manuals by other brands

Simrad
Simrad ES120-25X10 - REV C datasheet

PCI
PCI DPT-4001 Operation & maintenance manual

RS PRO
RS PRO ICA 31 instruction manual

Consilium
Consilium SAL R1E Installation

S+S Regeltechnik
S+S Regeltechnik THERMASGARD MWTM Operating Instructions, Mounting & Installation

Raymarine
Raymarine RV2 Series installation instructions