Timeguard DCA2 User manual

INSTALLATION & OPERATING INSTRUCTIONS
AUDIO DOOR ENTRY SYSTEM
Model: DCA1 Single Channel
DCA2 Twin Channel
DCA1DCA2
DCA1/2
DCA1_DCA2_Instructs_1.4.indd 1DCA1_DCA2_Instructs_1.4.indd 1 30/1/07 11:00:25 am30/1/07 11:00:25 am

1
7
3
10
5
2
1
4
9
8
1. Introduction
The DCA1/DCA2 Door Entry System enhances entry security by enabling the user
to recognise the potential entrant by audible means before opening the door.
An electric door catch (not supplied) is available as an optional extra for the
DCA1/DCA2 to make the door opening automatic.
The DCA2 external intercom has the ability to call separately located internal
intercoms for two individual dwellings with a common entrance.
The DCA1 calls one.
Connecting cables between component parts are all 2 core, so existing bell flex
can be used to connect the internal and external units if desired.
2. Overview
If operation with an electric door catch is required then part DCLR is a fail
(power off) secure catch available from Timeguard.
Fig 1
Component parts
of Single Channel
system.
1. External intercom
(1 channel shown)
2. Internal intercom
3. Mains adaptor
4. 15m of 2 core
connecting cable
5. Cable terminals
7. Ring button
8. Ringtone volume
adjust (2 position
switch)
9. Door open button
10. Mains adaptor low
voltage plug
DCA1_DCA2_Instructs_1.4.indd 2DCA1_DCA2_Instructs_1.4.indd 2 30/1/07 11:00:33 am30/1/07 11:00:33 am

2
Fig 2
Wiring diagram for Two Channel system.
6. Terminal strip
11. Mains adaptor socket
12. Internal intercom mounting hole
13. Cable channel
Note: For single channel operation ignore second channel internal intercom
and its 2 core connecting cable to terminals 3 and 4 on the external intercom.
Internal intercom
(first channel)
Internal intercom
(second channel)
External intercom
(DCA2 shown)
Electric door catch
(not supplied)
Handset cable
Handset cable
DCA1_DCA2_Instructs_1.4.indd 3DCA1_DCA2_Instructs_1.4.indd 3 30/1/07 11:00:34 am30/1/07 11:00:34 am

3
50cm
165
cm
75º
165
cm
3. Selecting intercom sites and cabling
3.1 Intercom sites
The internal intercom should be located at a convenient position for all potential
users at the height indicated in fig 3a and at a maximum distance of 70m from
the external intercom. If all the users are significantly above or below average
height then a different mounting height may be considered appropriate.
The external intercom should be sited in an area away from driving rain
and surface water, out of direct sunlight as far as possible and protected by the
minimum of an open porch in a position readily accessible to potential entrants.
It should be mounted at the height indicated in fig 3b.
Fig 3a
Internal intercom
mounting height
Fig 3b
External intercom mounting
height and coverage
DCA1_DCA2_Instructs_1.4.indd 4DCA1_DCA2_Instructs_1.4.indd 4 30/1/07 11:00:34 am30/1/07 11:00:34 am

4
3.2 Cabling
Connection between the internal and external intercoms is by 2 core cable and
must be no more than 70 m long. Two core (13 x 0.2) bell flex is suitable.
A 15m length (2 lengths for DCA2) of 2 core cable is supplied with the kit and
existing bell cable runs can be made use of.
The cable run should be kept at least 100mm away from mains cables to avoid
interference.
A second relatively short 2 core cable (13/0.2 bell flex) will be required between
the external intercom and the door catch (if used).
A further 2 core cable (13/0.2 bell flex) will be required (if extension beyond
15m is necessary) between the external intercom and the second internal
intercom for the DCA2.
4. Fixing Intercoms
4.1 External intercom
Important: To give the best possible waterproofing and appearance
we recommend taking the wiring through the exterior wall directly
behind the external intercom so that the cabling will feed directly
through the back box wiring slot. If the surface to be fixed to is not
even (e.g. pebbledash or brickwork with raised pointing) we recommend
the use of at least 10mm (3/8") thick marine ply as a mounting plate
between the wall and the back box to prevent its distortion and loss of
waterproofing.
DCA1_DCA2_Instructs_1.4.indd 5DCA1_DCA2_Instructs_1.4.indd 5 30/1/07 11:00:35 am30/1/07 11:00:35 am

5
xY
i Remove the back box from the external
intercom in the following way. Insert a
small screwdriver blade in the end cap
screwdriver notch (fig 4, i) and lever
end cap so that it slides outwards from
the main case (in opposite directions to
those shown in fig 4, iv). Remove the two
fixing screws (as shown in fig 4, iii) and
remove the back box from the rear of the
external intercom.
ii This is a convenient time to mark the
nameplate(s).
Referring to figs 5i and 5iii push catches
at each end of the transparent housing
inwards as shown in fig 5iii and remove
ring burtton and nameplate assembly
followed by the nameplate transparent
cover, finally levering out the nameplate
as required.
Mark the nameplate as required with a
permanent fibre-tipped pen. When dry
insert the name plate in its transparent
cover, ensuring it is the right way up.
Snap the transparent cover into the
housing bearing in mind it is not
symmetrical and the end with the thicker
lip goes at the end closest to the ring
button switch.
Offer the transparent housing to the
external intercom casing ensuring wiring
is not trapped and snap the catches into
place.
Check the ring button and the nameplate
are correctly located.
Repeat for second ring button and
nameplate assembly if necessary.
Fig 4
i
X = wire to the inside intercom
(2 for DCA2)
Y = wire to door catch (if required)
End plate
Screwdriver
notch
ii
iii
iv End cover
End cover
Wiring slot
DCA1_DCA2_Instructs_1.4.indd 6DCA1_DCA2_Instructs_1.4.indd 6 30/1/07 11:00:35 am30/1/07 11:00:35 am

6
12345678
Fig 5i – Rear access to nameplates (DCA2 shown)
Fig 5ii – Side view of length of nameplate
Fig 5iii – Transparent housing
Ring button
switch
CatchTransparent
housing
Push catch
inwards
PCB
This (thicker) end goes closest
to ring button switch
Catch
Ring button
switch
Transparent
housing
Catch
DCA1_DCA2_Instructs_1.4.indd 7DCA1_DCA2_Instructs_1.4.indd 7 30/1/07 11:00:35 am30/1/07 11:00:35 am

7
iii Offer the back box up to the required position on the wall (refer to section
3.1). Feed the cables through the wiring slot in the back box (see fig 4, ii).
Mark the positions of the two fixing screws (No. 8 roundhead) using the back
box as a template (see fig 4, ii). Remove the back box, drill and, if necessary
plug holes. Feed the cables through the wiring slot. Fix the back box to the
wall.
iv Make the necessary wire terminations (see fig 2) and offer the external
intercom up to the back box. Tighten the fixing screws as indicated (fig 4, iii).
v Slide the two end covers inwards as shown until fully home (see fig 4, iv).
4.2 Internal intercom
Choose a position which can be reached easily by all potential users. If one
person usually in one location will be the main user it may be considered
appropriate to locate the internal intercom within reach of that person.
Mark out two holes suitable for No. 8 roundhead screws 164mm vertically apart
at the required location on the wall (refer to section 3.1 and fig 2). Drill and
plug the holes if necessary then screw the screws home leaving 5mm of the
shank exposed (see fig 6) to enable keyhole fixing points to slide behind the
screws.
Connect the two core lead from the external intercom according to fig 2. Plug
the mains adaptor low voltage plug (see fig 1) into the mains adaptor socket
(see fig 2). Arrange the two cables in the cable channel on the back of the
internal intercom. Finally locate the internal intercom mounting holes on the
two fixing screws, and slide the intercom downwards.
Fig 6
Wall surface
5mm
DCA1_DCA2_Instructs_1.4.indd 8DCA1_DCA2_Instructs_1.4.indd 8 30/1/07 11:00:36 am30/1/07 11:00:36 am

8
5. Commissioning/Use
Press the ring button (fig 1, 7) at the external intercom – a buzz will be heard
locally and a ring tone will be heard at the internal intercom unit for 2 to 3
rings.
Once handset is lifted, two way communication is possible via the microphone
and speaker at the external intercom.
Finally, if a door catch is fitted, the door open button (fig 1, 9) should be pressed
and the door can be opened.
It is not necessary for the handset to be lifted to use the door open facility.
It is possible to adjust the ringtone volume with the slide switch (fig 1, 8) on the
side of the internal intercom.
6. Do’s and Dont’s
1. Never use the product if it shows any signs of damage.
2. In case of damage to the product unplug the mains adaptor from the mains
supply to avoid any possibility of electric shock and have the damage
examined by a competent person.
3. When laying cabling ensure that no cables (particularly mains cables) are
damaged.
4. Never try to operate the mains adaptor at a voltage other than 230V 50Hz.
5. The installation should only be carried out by a competent person.
6. The internal intercom should be kept out of reach of children and
unauthorised persons.
7. Keep low voltage cabling at least 100mm away from any mains cabling.
8. Ensure that all electrical connections are made and wires are arranged
according to the instructions.
9. Do not cover the louvres on the internal intercom.
DCA1_DCA2_Instructs_1.4.indd 9DCA1_DCA2_Instructs_1.4.indd 9 30/1/07 11:00:36 am30/1/07 11:00:36 am

9
7. Troubleshooting
No Audio Check cable between internal and external intercoms
is connected correctly.
Check that there are no breaks or damage to the
interconnecting two core cable.
Check that the mains adaptor is plugged in and
switched on.
Door catch not working Check cable between external intercom and door
catch for breaks or damage.
Check that terminations are correctly made at each
end of the above cable.
Check that the mains adaptor is plugged in and
switched on.
8. Cleaning
Unplug mains adaptor before cleaning product.
Clean internal and external intercoms with a damp cloth only – no cleaning
agents.
Remove dust deposits from the louvres on the internal intercom with a soft
brush or vacuum cleaner.
(if fitted)
DCA1_DCA2_Instructs_1.4.indd 10DCA1_DCA2_Instructs_1.4.indd 10 30/1/07 11:00:36 am30/1/07 11:00:36 am

10
9. Specifications
Mains adaptor: 230V 50Hz/15V, 1A
Maximum interconnect length between
internal and external intercoms: 70m (13/0.2 bell flex)
Power consuption Standby: 3W
In operation: 10W
Operating temperature: -10°C to +50°C
Ringtone volume: 80dBA at 0.3m maximum
(adjustable by 2 position
slide switch)
Door catch: Max 12V DC 1A
3 Year Guarantee
In the unlikely event of this product becoming faulty due to defective material
or manufacture within 3 years of the date of purchase, please return it to your
supplier in the first year with proof of purchase and it will be replaced free of
charge. For years 2 and 3 or any difficulty in the first year telephone the helpline
on 020 8450 0515.
Recycling
When service life is over please consult your local
authority regarding method of disposal.
DCA1_DCA2_Instructs_1.4.indd 11DCA1_DCA2_Instructs_1.4.indd 11 30/1/07 11:00:36 am30/1/07 11:00:36 am

11
For a product brochure please contact:
Timeguard Ltd.
Victory Park, 400 Edgware Road,
London NW2 6ND
020-8452-1112
HELPLINE
020-8450-0515
67-058-232
DCA1_DCA2_Instructs_1.4.indd 12DCA1_DCA2_Instructs_1.4.indd 12 30/1/07 11:00:36 am30/1/07 11:00:36 am
This manual suits for next models
1
Table of contents
Other Timeguard Intercom System manuals