Timotion TC15P Series User manual

(User Manual-Control box)
1/12
User manual-Control Box
TC15P series
General Information:

(User Manual-Control box)
2/12
Contact Information:
TiMOTION Technology Co., Ltd.
Shiyung Minyin Industrial Zone, Hengli Town, Dongguan, China, 523460
Symbol Descriptions
The following symbols may appear in this manual, on the label, or on its accessories. Some of the symbols
represent standards and compliances associated with the Control box and its use.
Caution: Consult accompanying documents
CE Mark: conform with the essential health and safety requirements set out in European
Directives.
The product can be used indoors only.
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste
separately for special treatment is necessary.
~ Alternating current
Direct current
Mode of operation:
Duty Cycle: Max 10%, Max 2 Min On /18 Min Off
Environmental Requirements
Operation conditions
Ambient temperature: 10 ~ 40℃℃
Relative humidity range: 10% ~ 93%
Atmospheric pressure: 86KPa~ 106Kpa
Storage and shipping conditions
Ambient temperature: -10 ~℃50℃
Relative humidity range: 10% ~ 93%
Atmospheric pressure: 86KPa~ 106KPa

(User Manual-Control box)
3/12
Warning:
1. Please read this user manual carefully before use.
2. You must be connected to the correct mains.
3. For any accessories connected to this control box, the plug type, pins definition and
electrical character must comply with its specifications.
4. Use only approved equipment. Do not use cables, handsets, actuators, or optional
equipment other than those specified by T-motion to function improperly.
5. Use only the specified power cord specified by the manufacturer.
6. Equipment not suitable for use in the presence of a flammable anaesthetic mixture with
air of with oxygen or nitrous oxide.
7. The device is not classified as category AP/APG equipment.
8. Disposal: Do not dispose of electrical appliances as unsorted municipal waste, use
separate collection facilities. Contact you local government for information regarding the
collection systems available. If electrical appliances are disposed of in landfills or dumps,
hazardous substances can leak into the groundwater and get into the food chain,
damaging your health and well-being.
9. The device is not suitable for use in the presence of flammable anesthetic mixtures with
air or with oxygen or nitrous oxide.
10. The device requires no calibration.
11. The device is not repairable and contains no user serviceable parts.
12. No modification of this equipment is allowed.
13. The user must check that the equipment functions safely and see that it is in proper
working condition before being used.
14. The manufacturer does not require such preventive inspections by other persons.
15. Do not position the equipment so that it is difficult to operate the disconnection device.

(User Manual-Control box)
4/12
FCC STATEMENT:
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference,and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
2. any Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC/IC Radiation Exposure Statement
This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body

(User Manual-Control box)
5/12
IC warning:
- English:
This device complies with Industry Canada’s licence-exempt RSSs. Operation is
subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause
undesired operation of the device.
- French:
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions
suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement."
Model No.:

(User Manual-Control box)
6/12
Modellist:
Model Input Max. Output (Actuator)
TC15P-ZQ120C 100-240VAC,50/60Hz,4A 32Vdc,10A
TC15P-ZQ120 100-240VAC,50/60Hz,4A 32Vdc,10A
Degree of protection against electric shock: No applied part
Protection against ingress of water: IP20
Mode of operation: Intermittent operation
This control box is designed to be used on motorized furniture and its basic function is to control
the movement of up to 2 electro-mechanical actuators.
Models TC15P-ZQ120C and TC15P-ZQ120 are identical except that 5V output.
The use of the output line is not more than 2 m.
Maintain & Cleaning:
- The control box is a maintain-free device. Under normal conditions, maintain is not
necessary.
- For some applications that not all DC Output (Actuator) connectors are used, the rubber
inserts are needed to seal those connectors which are not used. If these connectors are not
well sealed, the water/steam used in washing and cleaning may flow into the control box
which will cause unexpected damage to the control box.

(User Manual-Control box)
7/12
User manual-Control Box
TC15S series

(User Manual-Control box)
8/12
General Information:
Contact Information:
TiMOTION Technology Co., Ltd.
Shiyung Minyin Industrial Zone, Hengli Town, Dongguan, China, 523460
Symbol Descriptions
The following symbols may appear in this manual, on the label, or on its accessories. Some of the symbols
represent standards and compliances associated with the Control box and its use.
Caution: Consult accompanying documents
CE Mark: conform with the essential health and safety requirements set out in European
Directives.
The product can be used indoors only.
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste
separately for special treatment is necessary.
~ Alternating current
Direct current
Mode of operation:
Duty Cycle: Max 10%, Max 2 Min On /18 Min Off
Environmental Requirements
Operation conditions
Ambient temperature: 10 ~ 40℃℃
Relative humidity range: 10% ~ 93%
Atmospheric pressure: 86KPa~ 106Kpa
Storage and shipping conditions
Ambient temperature: -10 ~℃50℃
Relative humidity range: 10% ~ 93%
Atmospheric pressure: 86KPa~ 106KPa

(User Manual-Control box)
9/12
Warning:
1. Please read this user manual carefully before use.
2. You must be connected to the correct mains.
3. For any accessories connected to this control box, the plug type, pins definition and
electrical character must comply with its specifications.
4. Use only approved equipment. Do not use cables, handsets, actuators, or optional
equipment other than those specified by T-motion to function improperly.
5. Use only the specified power cord specified by the manufacturer.
6. Equipment not suitable for use in the presence of a flammable anaesthetic mixture with
air of with oxygen or nitrous oxide.
7. The device is not classified as category AP/APG equipment.
8. Disposal: Do not dispose of electrical appliances as unsorted municipal waste, use
separate collection facilities. Contact you local government for information regarding the
collection systems available. If electrical appliances are disposed of in landfills or dumps,
hazardous substances can leak into the groundwater and get into the food chain,
damaging your health and well-being.
9. The device is not suitable for use in the presence of flammable anesthetic mixtures with
air or with oxygen or nitrous oxide.
10. The device requires no calibration.
11. The device is not repairable and contains no user serviceable parts.
12. No modification of this equipment is allowed.
13. The user must check that the equipment functions safely and see that it is in proper
working condition before being used.
14. The manufacturer does not require such preventive inspections by other persons.
15. Do not position the equipment so that it is difficult to operate the disconnection device.

(User Manual-Control box)
10/12
FCC STATEMENT:
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference,and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
2. any Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC/IC Radiation Exposure Statement
This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body

(User Manual-Control box)
11/12
IC warning:
- English:
This device complies with Industry Canada’s licence-exempt RSSs. Operation is
subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause
undesired operation of the device.
- French:
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions
suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement."
Model No.:
Modellist:
Model Input Max. Output (Actuator)
TC15S-Z73Q 100-240VAC,50/60Hz,4A 32Vdc,8A
TC15S-Z73 100-240VAC,50/60Hz,4A 32Vdc,8A
Degree of protection against electric shock: No applied part
Protection against ingress of water: IP20
Mode of operation: Intermittent operation
This control box is designed to be used on motorized furniture and its basic function is to control
the movement of up to 2 electro-mechanical actuators.
Models TC15S-Z73Q and TC15S-Z73 are identical except that 5V output.

(User Manual-Control box)
12/12
The use of the output line is not more than 2 m.
Maintain & Cleaning:
- The control box is a maintain-free device. Under normal conditions, maintain is not
necessary.
- For some applications that not all DC Output (Actuator) connectors are used, the rubber
inserts are needed to seal those connectors which are not used. If these connectors are not
well sealed, the water/steam used in washing and cleaning may flow into the control box
which will cause unexpected damage to the control box.
Table of contents
Other Timotion Control Unit manuals
Popular Control Unit manuals by other brands

MSA
MSA Chillgard LC instruction manual

Spirax Sarco
Spirax Sarco SRV66HC Installation and maintenance instructions

TECH
TECH Sinum BT-01 quick start guide

Scully
Scully ST-47 Series Technical manual

Honeywell
Honeywell Gamewell FCI Velociti Series Installation and maintenance instructions

VAT
VAT 642 Series Installation, operating, & maintenance instructions