Thermostatic Radiator Valves (TRVs) sense the air temperature around them and
regulate the ow of water through the radiator that they are tted to. They do not
control the boiler.
They should be set at a level that gives you the room temperature you want. These
settings may need to be different in each room. You should set the TRVs to suit
each room and then leave them to do their job.
Turning a TRV to a higher setting will not make the room heat up any faster. How
quickly the room heats up depends on the boiler size and setting, as well as the
radiator size. Turning a TRV to a lower setting will result in the room being controlled
at a lower temperature, which saves energy.
TRVs require a free ow of air to sense the temperature, so they must not be
covered by curtains or blocked by furniture.
PRODUCT INFORMATION

INSTALLATION MANUAL
MODEL: TIS-TRV, TIS-TRV-16CNV
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TRV (THERMOSTATIC RADIATOR VALVE)
2
Mounting Location
Connected directly to the radiator valve or
with adaptors accessories.
Data Cable
Connect TIS-TRV-16CNV gateway by
stranded RS485 data cable with four
twisted pairs. Connect devices in a “daisy
chain.”
Do not cut or terminate live data cables.
Warranty
We provide a warranty as required by law.
Please send the description of the defect
with Product S/N to our dealer network.
Read Instructions
We recommend that you read this
Instruction Manual before installation.
Safety instructions
Electrical equipment should only be
installed and tted by electrically skilled
persons.
Failure to observe the instructions may
cause damage to the device and other
hazards.
These instructions are an integral part of
the product and must remain with the end
customer.
Programming
This device can be tested and
programmed manually. Advanced
programming requires TIS’s Device
Search software. Advanced software
programming knowledge should be
obtained in TIS’s advanced training
courses.
Simple Installation
TIS-TRV has an M30 x 1.5 universal type
head-to-body connection.

INSTALLATION MANUAL
MODEL: TIS-TRV, TIS-TRV-16CNV
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TRV (THERMOSTATIC RADIATOR VALVE)
3
INSTALLATION STEPS
1Replace your Radiator valve by TIS TRV,
in case your valve size or type not t
with TIS TRV you can use the adaptor
accessories inside the TIS TRV package.
▸
Valve installation (with M30 adaptor as an
example)
ADAPTERS
Thread-measure dimension of M30× 1.5
(Heimeier, Junkers Landys+Gyr, MNG,
Honeywell, Braukmann,)
NO ADAPTER REQUIRED
Danfoss RAV (accompanying pin must be
plugged on the valve tapped)
Danfoss RA
Danfoss RAVL

INSTALLATION MANUAL
MODEL: TIS-TRV, TIS-TRV-16CNV
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TRV (THERMOSTATIC RADIATOR VALVE)
4
2
3
Insert 2×AA batteries into the device.
Once the batteries are installed, the
TRV will display INIL, which means
initialization.
When the TRV displays AdAP, press the
UP button (change 0 to 1), which means
the TRV will adapt itself to the stroke of
your valve body. To do so, the TRV will
open and close twice to store the end
points.
INSTALLATION STEPS
MOUNTING POSITIONS

INSTALLATION MANUAL
MODEL: TIS-TRV, TIS-TRV-16CNV
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TRV (THERMOSTATIC RADIATOR VALVE)
5
Low battery indicator
Signal icon (Indicate when paired with gateway)
Current period
Child lock
Away mode
Window opened
Clock and weekday
Manual mode
PRG mode
DISPLAY & BUTTONS
MODE SETTING
Press the M button to choose between
Manual mode / Away mode / PRG mode.
CLOCK & WEEKDAY SETTING
Press and hold the P button for 5s, and set
the clock (Min-Hour-Weekday) by pressing
the UP and DOWN buttons. Each press of
the P button will go to next item setting.

INSTALLATION MANUAL
MODEL: TIS-TRV, TIS-TRV-16CNV
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TRV (THERMOSTATIC RADIATOR VALVE)
6
7-DAY PROGRAMMABLE SETTING
After completing the clock settings, press P
to go to PRG schedule settings.
Set the schedule (Weekday-Period-Start
time-Temp.) by pressing the UP and DOWN
buttons. Each press of the P button will go to
next item setting.
PERIOD 1 2 3 4
Time Temp Time Temp Time Temp Time Temp
12345
(Mon.~Fri.) 7:00 22℃ 8:30 19℃ 17:00 22℃ 22:00 19℃
6 (Sat.) 8:00 22℃ 8:30 22℃ 17:00 22℃ 22:00 19℃
7 (Sun.) 8:00 22℃ 8:30 22℃ 17:00 22℃ 22:00 19℃
2
1

INSTALLATION MANUAL
MODEL: TIS-TRV, TIS-TRV-16CNV
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TRV (THERMOSTATIC RADIATOR VALVE)
7
OPEN WINDOW DETECT FUNCTION (OWD FUNCTION)
When the Open Window mode is enabled
in the parameter settings, the system will
automatically stop heating when it detects
a sudden drop of room temperature (2°C
in 15 minutes as default). This is normally
caused when a window or door is opened
without turning off the heating device.
The device will return to the previous
mode of operation after 30 minutes. At
that time, the OP indicator will disappear.
Pressing any button will exit the OWD
function during the heating off period.
PARAMETER SETTINGS
To congure your TRV, you need to turn
off the thermostat rst and then press and
hold the Mand UP buttons for 3s, until it
displays 01. Each press of the Mbutton
will go to the next item setting. Adjust the
range by using the UP and DOWN buttons.
3”
30’

INSTALLATION MANUAL
MODEL: TIS-TRV, TIS-TRV-16CNV
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TRV (THERMOSTATIC RADIATOR VALVE)
8
MENU DESCRIPTION RANGE DEFAULT
VALUE
01 Temp. calibration for internal sensor -8 ℃ ~8 ℃ 0℃
02 Set Point Max. 5 ℃ ~35℃ 35 ℃
03 Set Point Min. 5 ℃ ~35℃ 5 ℃
05 Frost Protection Temp. 5 ℃ ~15℃ 5 ℃
10 Display 0: Room temp.
1: SET temp. 0
12 Open window detect function 1: ON 0: OFF 0
13 OWD Detect Time 2~30mins 15mins
14 OWD Drop temp. select
(within detect time) 2.3.4’C 2 ‘C
15 OWD Delay time select
(Return to previous working status) 10~60min 30mins
17 Factory reset
0: No
1: Yes, and then press On/off button
for 5s, waitt until thermostat restarts
0
18 Software version
19 Software version
31 Battery voltage Unit: 10mv
32 PID P-band select 2 ℃ ~10℃ 7℃
33 PID I-time select 30~90min 30min
PARAMETER SETTINGS

INSTALLATION MANUAL
MODEL: TIS-TRV, TIS-TRV-16CNV
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TRV (THERMOSTATIC RADIATOR VALVE)
9
PRG Button
1Press the Gateway’s (TIS-TRV-16CNV)
PRG button 3 times. The PRG green
LED will turn steady ON.
You can pair up to 16 TIS TRVs to the TIS-TRV-16CNV Gateway. To do so, follow these
instructions:
Turn the TRV module OFF by pressing
the power button.
2
CONFIGURATION STEPS (Pairing TRV with Gateway)
Long press the M button on the TRV for
6 seconds. The graph on the TRV’s LCD
will change.
3
6”

INSTALLATION MANUAL
MODEL: TIS-TRV, TIS-TRV-16CNV
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TRV (THERMOSTATIC RADIATOR VALVE)
10
Press the UP button on the TRV.
Wait for the Gateway’s (TIS-TRV-16CNV)
PRG LED to change to normal. The
pairing is done.
You can see each TRV number and edit its name in the Device Search software by double
clicking on the TRV.
From Luna or another TIS panel’s Slave AC, you can add the Subnet Device ID and slave
number for the TRV.
From the TIS app, you can control the TRV by selecting Panel Control > AC and adding the
address of the TRV Gateway and AC number as TRV numbers.
Do the same steps for other TRVs. You can pair a maximum of 16 TRVs.
You can also delete all info and remove TRV from network.
4
5
CONFIGURATION STEPS (Pairing TRV with Gateway)

INSTALLATION MANUAL
MODEL: TIS-TRV, TIS-TRV-16CNV
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TRV (THERMOSTATIC RADIATOR VALVE)
11
TROUBLESHOOTING
PRG button blinks purple color
rapidly.
Reason: The plug address conicts with
another device in the TIS network. You
need to press and hold the PRG button for
6 seconds so that the module can get a new
address.
No display turned on in the TRV
LCD
Reason: The battery is low. Replace it with
a new one.
TRV cannot link to Gateway.
Reason 1: The Gateway is full. Use the
Device Search software to format it or delete
the programmed TRV.
Reason 2: TRV is too far from the Gateway.
“OP” signal displayed and
heating not turning on.
Reason: Door opening detection is
enabled, and there were sudden changes
in temperature. Press any button to turn the
heat on again.
The wall panels can’t control
the TRV.
Reason 1: The TIS-BUS connection is
not linked to the TRV Gateway.
Reason 2: The programming address is
wrong.
This manual suits for next models
1
Table of contents
Other TIS Control Unit manuals
Popular Control Unit manuals by other brands

Telegesis
Telegesis ETRX357-LR Command manual

Jetter
Jetter JXM-IO-EW30-G27 user manual

KSB
KSB MIL 76000 instruction manual

Samsung
Samsung OfficeServ 7400 GPLIMT user manual

Allen-Bradley
Allen-Bradley POINT I/O 1734-VHSC5 user manual

Jefferson Solenoid Valves U.S.A. Inc.
Jefferson Solenoid Valves U.S.A. Inc. Z1314BV**AT Z1314BLV24AT Installation and Maintenance