Eos 1
• Warnings
• Eos 1 – Humidify/Dehumidify Controller Overview
• Instructions for Operation
• Troubleshooting Tips
• Controller Specifications
• Installation Examples
• Warranty Information
• Service and Repair Program
Warnings
• Read all instructions before operating controller.
• Do not put your controller in an area where it can get wet or sprayed.
• Mount your controller securely to the wall using hardware provided.
• When using “bug bombs” in area, cover controller completely to avoid corrosion.
• Keep vents free from obstructions to allow the controller to function properly.
• There are no serviceable parts in controller. Do not attempt to repair the unit.
• Breaking “warranty” seal will void your warranty.
• Do not put paperclips, tools, etc. into unit. Possible electrocution may occur.
• Plug controller into surge protector to avoid potential damage to the unit.
• Make sure to verify your power source prior to plugging controller into outlet.
• Check that all equipment that will be activated by this controller is the proper voltage.
• This controller is designed for inside use only.
• Avoid placing the controller near heat generating sources.
• Use caution when operating controller in extremely humid environments.
• Do not use controller for purposes other than the unit was designed to function
• Use controller within defined environmental specifications.
• Ask your Dealer for tips and techniques regarding the use of this controller.
• Be conscientious when disposing of any products.
• Enjoy your Titan Controls environmental controller for years to come!
Eos 1 – Humidify / Dehumidify
Controller Overview
The EOS 1 Humidify/Dehumidify Controller is used to control a device that will either increase
or reduce the humidity in your area. You can set your desired relative humidity by adjusting the
dial on the front of the unit. The adjustment of the dial ranges from 10% RH to 90% RH in a
non-condensing environment. After setting the dial at the preferred setting, the controller will
WARRANTY SERVICE: Please read warranty information first
If after reviewing the troubleshooting tips the unit will still not work, you should return it to the
Dealer where you purchased it. They will be able to further evaluate the unit and test its various
components and quite possibly will be able to identify and/or fix any problems. If the Dealer is
unable to fix the unit, they will return it to us for factory repair.
If there are no Dealers in your area, you may contact us directly for technical support. If we cannot
help you resolve the problem over the phone, we will issue you a RMA # (return merchandise
authorization) authorizing you to return the unit to us for factory reconditioning (if the unit is under
warranty). Contact the number below for a RMA and shipping address. Complete the form below
and include it with your unit. Also please write the RMA # on the outside of the box.
Please package the unit in its original packaging. If it is damaged in shipment we cannot be
responsible.
Once we receive the unit back, we will repair it within 48 hours (business) and return it to you
freight prepaid via FedEx or UPS ground shipment.
Include the following if returning directly to Titan Controls
• Proof of purchase • This completed form • RMA # on the outside of the box
Return Merchandise Authorization Number (Required
Company Name: ____________________________________________________________________________________
Contact Name: _____________________________________________________________________________________
Address: __________________________________________________________________________________________
____________________________________________________________________________________________________
Phone #: ___________________________________________________________________________________________
Email address: _______________________________________________________________________________
What is the nature of the problem?
______________________________________
___________________________________________________________
___________________________________________________________
___________________________________________________________
___________________________________________________________
_______________________________________________________
Send to your nearest location – shipping address will be given when the RMA # is issued:
www.titancontrols.net
For technical assistance call us at 1-888-80-Titan or 1-888-808-4826.
maintain that setting utilizing a 4% differential or deadband. At 70% RH in the humidify mode,
the equipment will be activated at 68% RH, and will deactivate at 72% RH. In the dehumidify
mode, with the setting at 70% RH, the equipment will activate at 72% RH, and deactivate at
68% RH. This differential allows your equipment to perform at an optimum level with minimum
cycling and reduces stress to your equipment.
The switch on the bottom right of the controller is used to determine whether it will be used in
the “Humidify” mode or the “Dehumidify” mode.
The Eos 1 provides up to 15 amps of capacity on a standard 120 volt circuit. The Eos 1 is built
with the highest quality components and will provide the user with years of trouble free service.
Instructions for Operation
• Securely mount your Eos 1 in your enclosure and away from any spray/water/mist, etc.
• Set the “Humidify/Dehumidify” switch to activate your equipment at preferred setting.
• Plug your equipment into the female side of the piggyback cord set.
• Adjust your equipment (humidifier, dehumidifier or fan) to highest setting on the dial.
• Verify that the equipment to be activated is turned “ON”
• Plug the male side of the piggyback cord set into a 120 volt / 15 amp outlet. Use of a surge
protection power strip is recommended.
• Your Eos 1 will now control your equipment at the desired settings until the power is defeated.
• To reset your Eos
1. Simply unplug the piggyback cord from the 120 volt outlet, adjust your settings,
and plug it back into the 120 volt outlet to activate controller at new settings
Troubleshooting Tips
If the Eos 1 is not performing as expected, try the following:
a. Confirm that your power input is active and providing 120 volts/ 15 amps
to the controller.
b. Check the voltage output of your piggyback cord set using a voltage test meter,
fan or 120 volt light to verify power is flowing through controller when activated.
c. Make sure that your “Humidification/Dehumidification” switch is in the correct
mode for your application.
d. If your Eos 1 is not functioning in the correct mode, check the vents to see if there
are any obstructions or impediments covering them. If so, clean the vents using
warm water on a soft cloth. Allow unit to completely dry before using.
e. Should you find that your Eos 1 is not activating your equipment, verify that your
setting on the controller is correct and that the power switch on your equipment is
“on” and at the highest setting.
f. If you’re still having problems with your Eos 1, please contact our Technical Service
Representative to assist you further.
Warranty Information
• Titan Controls warrants the original purchase of this product against defects in material and
workmanship under normal use for three (3) years from the date of purchase.
• During the warranty period, Titan Controls will, at our option, and without charge, repair or
replace this product if the controller or any of its components fail or malfunction.
• All returns or repairs must be accompanied by a Return Merchandise Authorization (RMA)
number prior to any service of the product.
• This warranty is expressly in lieu of all other warranties, expressed or implied, including the
warranties of merchantability and fitness for use and of all other obligations or liabilities on the
part of the seller.
• This warranty shall not apply to this product or any part thereof which had been damaged by
accident, abuse, misuse, modification, negligence, alteration or misapplication.
• Controllers with serial numbers or date tags that have been removed, altered or obliterated;
broken seals or that show evidence of tampering; mismatched board serial numbers or
nonconforming parts, are excluded from coverage.
• Titan Controls makes no warranty whatsoever in respect to accessories or parts not
supplied by Titan Controls.
• Monetary refunds of the warranty will not be given.
• The Buyer assumes all responsibility regarding the use & installation of this controller.
• All warranty service is provided through the factory or an authorized service representative.
• This warranty shall apply only to the United Sates, including Alaska, Hawaii and territories of the
United States.
• Defective controllers need to be returned with the “proof of purchase/receipt”.
• For additional warranty information, contact a Titan Controls Technical Service Representative or
your Dealer.
• NOTE: Titan Controls is a manufacturer of environmental controls. All sales offerings to the
public are done through a nationwide group of Dealers. No sales offerings will be made directly
to the general public.
Service and Repair Program
• For all service and repairs please contact one of our Technical Service Representatives for a
Return Merchandise Authorization (RMA) number.
• All factory service & repairs will be completed within 48 hours of receipt of controller and after
authorization by customer for repairs.
• Titan Controls will, at its discretion, repair or replace the controller.
• Factory calibration services are available for all Titan Controls.
• Returning Units: Please contact your retail store for returns.
Controller Specifications:
• Size = 8”H x 4”W x 2.5”D
• Weight = 2 lbs.
• Input Voltage = 120 VAC – 60 Hz
• Output Voltage = 120 VAC – 60 Hz
• Maximum Amperage = 15 amps
• Differential/Deadband = 4% split
• Minimum Humidity Control = 10% RH (Non-condensing)
• Maximum Humidity Control = 90% RH (Non-condensing)
• RoHS compliant = Yes
• Cord set = 6 feet - 14/4 SWJ
• Storage Temperature = 32°F (0°C) to 135°F (58°C)
• Operating Temperature = 32°F (0°C) to 120°F (50°C)
Installation Examples
Eos 1
Humidifier
E
os
1
Fan
Dehumidifie
Eos 1
Controlling a Humidifier
Controlling a Fan
Controlling a Dehumidifier

Other Titan Controls Controllers manuals

Titan Controls Helios 16 User manual

Titan Controls

Titan Controls Helios 16 User manual

Titan Controls Atlas 3 User manual

Titan Controls

Titan Controls Atlas 3 User manual

Titan Controls Nyx 1 User manual

Titan Controls

Titan Controls Nyx 1 User manual

Titan Controls Helios 13 User manual

Titan Controls

Titan Controls Helios 13 User manual

Titan Controls Helios 7 User manual

Titan Controls

Titan Controls Helios 7 User manual

Titan Controls HELIOS 3 Product information sheet

Titan Controls

Titan Controls HELIOS 3 Product information sheet

Titan Controls Helios 11 User manual

Titan Controls

Titan Controls Helios 11 User manual

Titan Controls EOS 702603 User manual

Titan Controls

Titan Controls EOS 702603 User manual

Titan Controls Helios 6 User manual

Titan Controls

Titan Controls Helios 6 User manual

Titan Controls Helios 3 User manual

Titan Controls

Titan Controls Helios 3 User manual

Titan Controls HyperioN 2 User manual

Titan Controls

Titan Controls HyperioN 2 User manual

Titan Controls SPARTAN Series User manual

Titan Controls

Titan Controls SPARTAN Series User manual

Titan Controls Helios 17 User manual

Titan Controls

Titan Controls Helios 17 User manual

Titan Controls Hades  2 User manual

Titan Controls

Titan Controls Hades 2 User manual

Titan Controls SOARTAN Series User manual

Titan Controls

Titan Controls SOARTAN Series User manual

Titan Controls Helios 12 User manual

Titan Controls

Titan Controls Helios 12 User manual

Titan Controls Helios 3 User manual

Titan Controls

Titan Controls Helios 3 User manual

Titan Controls Mercury 3 Product information sheet

Titan Controls

Titan Controls Mercury 3 Product information sheet

Titan Controls Kronus 4 User manual

Titan Controls

Titan Controls Kronus 4 User manual

Titan Controls 8 Light Controller User manual

Titan Controls

Titan Controls 8 Light Controller User manual

Titan Controls CO2 Regulator User manual

Titan Controls

Titan Controls CO2 Regulator User manual

Titan Controls Helios 14 User manual

Titan Controls

Titan Controls Helios 14 User manual

Titan Controls Oceanus 1 User manual

Titan Controls

Titan Controls Oceanus 1 User manual

Titan Controls Mercury 2 Product information sheet

Titan Controls

Titan Controls Mercury 2 Product information sheet

Popular Controllers manuals by other brands

SEW-Eurodrive MOVIFIT-MC manual

SEW-Eurodrive

SEW-Eurodrive MOVIFIT-MC manual

Fagor CNC 8070 Programming manual

Fagor

Fagor CNC 8070 Programming manual

Honeywell HR 80 Installation and user guide

Honeywell

Honeywell HR 80 Installation and user guide

Emerson Bettis RTS CL Series User instructions

Emerson

Emerson Bettis RTS CL Series User instructions

Hamworthy Merley Installation, commissioning and operating instructions

Hamworthy

Hamworthy Merley Installation, commissioning and operating instructions

Sunricher SR-ZV9001T-CCT-US instruction manual

Sunricher

Sunricher SR-ZV9001T-CCT-US instruction manual

Osram ENCELIUM EN-WS-SC3D-GB2-WT Wiring and installation instruction

Osram

Osram ENCELIUM EN-WS-SC3D-GB2-WT Wiring and installation instruction

Sonelco P3271 manual

Sonelco

Sonelco P3271 manual

ICPDAS TPD-433F quick start guide

ICPDAS

ICPDAS TPD-433F quick start guide

Fleck 7000SXT Service manual

Fleck

Fleck 7000SXT Service manual

Omron SGE Series manual

Omron

Omron SGE Series manual

Chamberlain T Installation

Chamberlain

Chamberlain T Installation

Overland Storage NEO 200S instructions

Overland Storage

Overland Storage NEO 200S instructions

DFE STEADYWEB 6 quick start guide

DFE

DFE STEADYWEB 6 quick start guide

National Instruments NI-7931 Getting started guide

National Instruments

National Instruments NI-7931 Getting started guide

Ramix PMC422 Hardware reference manual

Ramix

Ramix PMC422 Hardware reference manual

Linear Technology DC1900A Demo Manual

Linear Technology

Linear Technology DC1900A Demo Manual

TIS ADS-4CH-0-10V installation manual

TIS

TIS ADS-4CH-0-10V installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.