manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. TJERNLUND
  6. •
  7. Switch
  8. •
  9. TJERNLUND PS1503 DUCT BOOSTER FAN SWITCH 8500130 REV A... User guide

TJERNLUND PS1503 DUCT BOOSTER FAN SWITCH 8500130 REV A... User guide

This manual suits for next models

1

Other TJERNLUND Switch manuals

TJERNLUND 950-0452 PAI-1,2 PROVER KIT 8504044 REV. 1... User manual

TJERNLUND

TJERNLUND 950-0452 PAI-1,2 PROVER KIT 8504044 REV. 1... User manual

TJERNLUND SIDESHOT SS2 User manual

TJERNLUND

TJERNLUND SIDESHOT SS2 User manual

TJERNLUND 950-2080 NEW STYLE GAS PRESSURE SWITCH User manual

TJERNLUND

TJERNLUND 950-2080 NEW STYLE GAS PRESSURE SWITCH User manual

TJERNLUND SIDESHOT SS1C INCREASED CAPACITY OIL VENT SYSTEM... User manual

TJERNLUND

TJERNLUND SIDESHOT SS1C INCREASED CAPACITY OIL VENT SYSTEM... User manual

TJERNLUND PS2501 FAN PROVING SWITCH User manual

TJERNLUND

TJERNLUND PS2501 FAN PROVING SWITCH User manual

TJERNLUND SIDESHOT SS2 User manual

TJERNLUND

TJERNLUND SIDESHOT SS2 User manual

TJERNLUND WHKE MILLIVOLT INTERLOCK KIT (COMPATIBLE WITH UC1 CONTROL) 8504108 REV... User manual

TJERNLUND

TJERNLUND WHKE MILLIVOLT INTERLOCK KIT (COMPATIBLE WITH UC1 CONTROL) 8504108 REV... User manual

TJERNLUND PS1505 IN-LINE DRAFT INDUCER FAN PROVING SWITCH 8500135 REV 1... User manual

TJERNLUND

TJERNLUND PS1505 IN-LINE DRAFT INDUCER FAN PROVING SWITCH 8500135 REV 1... User manual

TJERNLUND SIDESHOT SS1C INCREASED CAPACITY OIL VENT SYSTEM... User manual

TJERNLUND

TJERNLUND SIDESHOT SS1C INCREASED CAPACITY OIL VENT SYSTEM... User manual

TJERNLUND SideShot SS1 Guide

TJERNLUND

TJERNLUND SideShot SS1 Guide

TJERNLUND PS1503 DUCT AIRSTAT FAN PROVING SWITCH REV A... User manual

TJERNLUND

TJERNLUND PS1503 DUCT AIRSTAT FAN PROVING SWITCH REV A... User manual

TJERNLUND PS1505 FAN PROVER 8504008 REV 1 0197 User manual

TJERNLUND

TJERNLUND PS1505 FAN PROVER 8504008 REV 1 0197 User manual

Popular Switch manuals by other brands

SMC Networks SMC6224M Technical specifications

SMC Networks

SMC Networks SMC6224M Technical specifications

Aeotec ZWA003-S operating manual

Aeotec

Aeotec ZWA003-S operating manual

TRENDnet TK-209i Quick installation guide

TRENDnet

TRENDnet TK-209i Quick installation guide

Planet FGSW-2022VHP user manual

Planet

Planet FGSW-2022VHP user manual

Avocent AutoView 2000  AV2000BC AV2000BC Installer/user guide

Avocent

Avocent AutoView 2000 AV2000BC AV2000BC Installer/user guide

Moxa Technologies PT-7728 Series user manual

Moxa Technologies

Moxa Technologies PT-7728 Series user manual

Intos Electronic inLine 35392I operating instructions

Intos Electronic

Intos Electronic inLine 35392I operating instructions

Cisco Catalyst 3560-X-24T Technical specifications

Cisco

Cisco Catalyst 3560-X-24T Technical specifications

Asante IntraCore IC3648 Specifications

Asante

Asante IntraCore IC3648 Specifications

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Siemens

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Edge-Core DCS520 quick start guide

Edge-Core

Edge-Core DCS520 quick start guide

RGBLE S00203 user manual

RGBLE

RGBLE S00203 user manual

Thrustmaster FLIGHT SIMULATOR X quick guide

Thrustmaster

Thrustmaster FLIGHT SIMULATOR X quick guide

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Southwire

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Buhler Nivotemp NT 61 Brief instructions

Buhler

Buhler Nivotemp NT 61 Brief instructions

Kramer VS-41HDCP user manual

Kramer

Kramer VS-41HDCP user manual

Techly IDATA AU-270 user manual

Techly

Techly IDATA AU-270 user manual

Belkin F1U109 user manual

Belkin

Belkin F1U109 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

TJERNLUND MODEL PS1503
POSITIVE AIR FLOW PRESSURE SWITCH
FEATURES
High Sensitivity
Maximum Temperature Limit of 1900F.
Simple Installation
Self-Sealing Factory Mounted Sampling Tube
Mounting Hardware
The Tjernlund Duct Airstat senses positive pressure in a forced
air heating and/or cooling system. The single pole, single throw,
snap-acting switch is activated by a diaphragm with a factory
installed sampling tube inserted directly into the duct or plenum.
The Duct Airstat can be used to initiate such auxiliary devices
as: Duct Boosters, Electronic Air Cleaners, Electrical Duct
Heaters, and Humidifiers. The electrical contacts of the switch
are closed upon sensing positive air pressure generated by the
blower.
Switch actuates air
cleaner by sensing
positive plenum pressure.
Switch activates humidifier
by sensing positive plenum
pressure.
Switch proves operation
of blower by sampling
positive pressure.
ELECTRONIC AIR CLEANERS HUMIDIFIERS FAN OPERATION
Switch activates Duct Booster by sensing positive pressure on either plenum, trunk, or branch lines as shown in Figures A and B above.
A B
TYPICAL MOUNTING LOCATIONS & APPLICATIONS
ELECTRICAL RATING:
278 VA Pilot Duty at 24 Volts AC
300 VA Pilot Duty at 115 to 277 Volts AC
15 AMPS Non-Inductive to 277 Volts AC
ELECTRICAL SWITCH:
SPST, N/O, Snap Action Contacts, Non Adjustable
OPERATING PRESSURE / POSITION:
On pressure rise at +.05 + .02” W.C. (Diaphragm Vertical)
MAXIMUM PRESSURE:
1/2 PSI
OPERATING TEMPERATURE RANGE:
-40 to 1900F.
SAMPLING TUBE:
Self-sealing, factory mounted tube
DIMENSIONS:
5” Diam., 5 1/2” Across Bracket, 3” High
GENERAL SPECIFICATIONS
Distributed By:
Trunk Line
Plenum
115-120V
Duct
Airstat Duct
Booster
Electronic
Air Cleaner
Electronic
Duct Heater Humidifier
Duct Booster
Branch
Run
© 1997 Tjernlund Products, Inc. P/N 8500130 Rev. A 4/99
TYPICAL APPLICATIONS
SWITCH MUST BE MOUNTED
WITH DIAPHRAGM IN
VERTICAL POSITION
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com
SIDE VIEW TOP VIEW