TLV EF200F-C User manual

172-65757M-01(EF200F-CVortexflowmeter)7June2022
EF200F-C
Vortexflowmeter
Copyright©2022byTLVCO.,LTD.
Allrightsreserved

EF200F-C
2
• Makesurethedocumentisstoredinasafeplacesuchthatitisalwaysavailablewhen
workingonorwiththedevice.
• Toavoiddangertoindividualsorthefacility,readthe"Basicsafetyinstructions"section
carefully,aswellasallothersafetyinstructionsinthedocumentthatarespecificto
workingprocedures.
• Themanufacturerreservestherighttomodifytechnicaldatawithoutpriornotice.Your
TLVSalesCenterwillsupplyyouwithcurrentinformationandupdatesto
theseinstructions.

EF200F-C Tableofcontents
3
Table of contents
1 Aboutthisdocument
1.1 Documentfunction
1.2 Symbols
1.2.1 Safetysymbols
1.2.2 Electricalsymbols
1.2.3 Toolsymbols
1.2.4 Symbolsfor
1.2.5 Symbolsingraphics
certaintypesofinformation
1.3 Documentation
1.3.1 Standarddocumentation
1.3.2 Supplementarydevice-dependent
documentation
2 Safetyinstructions
2.1 Requirementsforthepersonnel
2.2 Designateduse
2.3 Workplacesafety
2.4 Operationalsafety
2.5 Productsafety
2.6 ITsecurity
2.7 Device-specificITsecurity
2.7.1 Protectingaccessviahardwarewrite
protection
2.7.2 Protectingaccessviaapassword
2.7.3 Accessviafieldbus
3 Productdescription
3.1 Productdesign
4 Incomingacceptanceandproduct
identification
4.1 Incomingacceptance
4.2 Productidentification
4.2.1 Transmitternameplate
4.2.2 Sensornameplate(remoteversion)
4.2.3 NameplateforTEG
5 Storageandtransport
5.1 Storageconditions
5.2 Transportingtheproduct
5.2.1 Measuringdeviceswithoutlifting
lugs
(compactversion/remoteversion)
5.2.2 Measuringdeviceswithliftinglugs
6 Installation
6.1 Installationconditions
6.1.1 Mountingposition
6.1.2 Environmentandprocess
requirements
6.1.3 Ensuringaccuratemeasurements
6.2 Mountingthemeasuringdevice
6.2.1 Requiredtools
6.2.2 Preparingthemeasuringdevice
6.2.3 Mountingthesensor
6.2.4 Mountingthepressuremeasuring
unit
6.2.5 Mountingthetransmitterofthe
remoteversion
6.2.6 Turningthetransmitterhousing
6.2.7 Turningthedisplaymodule
6.3 Post-installationcheck
7 Electricalconnection
7.1 Connectionconditions
7.1.1 Requiredtools
7.1.2 Connectingcablerequirements
7.1.3 Connectingcableforremote
version
7.1.4 Terminalassignment
7.1.5 Requirementsforthesupplyunit
7.1.6 Preparingthemeasuringdevice
7.2 Connectingthemeasuringdevice
7.2.1 Connectingthecompactversion
7.2.2 Connectingtheremoteversion
7.2.3 Connectingtheconnectingcablefor
thepressuremeasuringcell
7.2.4 Ensuringpotentialequalization
7.3 Ensuringthedegreeofprotection
7.4 Post-connectioncheck
8 Operationoptions
8.1 Overviewofoperationoptions
8.2 Structureandfunctionoftheoperating
menu
8.2.1 Structureoftheoperatingmenu
8.2.2 Operatingphilosophy
8.3 Accesstotheoperatingmenuviathelocal
display
8.3.1 Operationaldisplay
8.3.2 Navigationview
8.3.3 Editingview
8.3.4 Operatingelements
8.3.5 Openingthecontextmenu
8.3.6 Navigatingandselectingfromlist
8.3.7 Callingtheparameterdirectly
8.3.8 Callinguphelptext
8.3.9 Changingtheparameters
2.8 Vibrations
2.9 PreventingExcessiveFlow
2.10 PulsatingInfluences
2.11 PreventMixedPhaseFlowy
2.12 EnsurePipeisFlooded
2.13 BypassLines
7.5 ConnectingtoTLVEC351FlowComputer

Tableofcontents EF200F-C
4
8.3.10 Userrolesandrelatedaccess
authorization
8.3.11 Disablingwriteprotectionviaaccess
code
8.3.12 Enablinganddisablingthekeypad
lock
8.4 Accesstotheoperatingmenuviathe
operatingtool
8.4.1 Connectingtheoperatingtool
9 Systemintegration
9.1 Overviewofdevicedescriptionfiles
10 Commissioning
10.1 Functioncheck
10.2 Switchingonthemeasuringdevice
10.3 Settingtheoperatinglanguage
10.4 Configuringthemeasuringdevice
10.4.1 Definingthetagname
10.4.2 Settingthesystemunits
10.4.3 Selectingandsettingthemedium
10.4.4 Configuringthecurrentinput
10.4.5 Configuringthecurrentoutput
10.4.6 Configuringthepulse/frequency/
switchoutput
10.4.7 Configuringthelocaldisplay
10.4.8 Configuringthelowflowcutoff
10.5 Advancedsettings
10.5.1 Settingthemediumproperties
10.5.2 Performingexternalcompensation
10.5.3 Carryingoutasensoradjustment
10.5.4 Configuringthetotalizer
10.5.5 Carryingoutadditionaldisplay
configurations
10.5.6 Configurationmanagement
10.5.7 Usingparametersfordevice
administration
10.6 Configurationmanagement
10.6.1 Functionscopeofthe"Configuration
management"parameter
10.7 Simulation
10.8 Protectingsettingsfromunauthorized
access
10.8.1 Writeprotectionviaaccesscode
10.8.2 Writeprotectionviawriteprotection
switch
10.9 Application-specificcommissioning
10.9.1 Steamapplication
10.9.2 Liquidapplication
10.9.3 Gasapplications
10.9.4 Calculationofthemeasured
variables
11 Operation
11.1 Readingthedevicelockingstatus
11.2 Adjustingtheoperatinglanguage
11.3 Configuringthedisplay
11.4 Readingmeasuredvalues
11.4.1 Processvariables
11.4.2 "Totalizer"submenu
11.4.3 Inputvalues
11.4.4 Outputvalues
11.5 Adaptingthemeasuringdevicetotheprocess
conditions
11.6 Performingatotalizerreset
11.6.1 Functionscopeofthe"Control
Totalizer"parameter
11.6.2 Functionscopeofthe"Resetall
totalizers"parameter
12 Diagnosticsandtroubleshooting
12.1 Generaltroubleshooting
12.2 Diagnosticinformationonlocaldisplay
12.2.1 Diagnosticmessage
12.3 Adaptingthediagnosticinformation
12.3.1 Adaptingthediagnosticbehavior
12.3.2 Adaptingthestatussignal
12.4 Overviewofdiagnosticinformation
12.4.1 Operatingconditionsfordisplaying
thefollowingdiagnostics
information
12.4.2 Emergencymodeintheeventof
pressurecompensation
12.4.3 Emergencymodeineventof
temperaturecompensation
12.5 Pendingdiagnosticevents
12.6 Diagnosticlist
12.7 Eventlogbook
12.7.1 Readingouttheeventlogbook
12.7.2 Filteringtheeventlogbook
12.7.3 Overviewofinformationevents
12.8 Resettingthemeasuringdevice
12.8.1 Functionscopeofthe"Devicereset"
parameter
12.9 Deviceinformation
13 Maintenance
13.1 Maintenancetasks
13.1.1 Exteriorcleaning
13.1.2 Interiorcleaning
13.1.3 Replacingseals
13.1.4 Adjustingthepressuremeasuring
cell
9.1.1
Currentversiondateforthedevice
12.2.2 Callingupremedialmeasures

EF200F-C Tableofcontents
5
14 Repair
14.1 Generalnotes
14.1.1 Repairandconversionconcept
14.1.2 Notesforrepairandconversion
14.2 Spareparts
14.3 Disposal
14.3.1 Removingthemeasuringdevice
14.3.2 Disposingofthemeasuringdevice
15 Accessories
15.1 Device-specificaccessories
15.1.1 Forthetransmitter
15.1.2 Forthesensor
16 Technicaldata
16.1 Application
16.2 Functionandsystemdesign
16.3 Input
16.4 Output
16.5 Powersupply
16.6 Performancecharacteristics
16.7 Installation
16.8 Environment
16.9 Process
16.10 Mechanicalconstruction
16.11 Operability
16.12 Certificatesandapprovals
16.13 Applicationpackages
16.14 Accessories
16.15 Supplementarydocumentation
17 FlowRatedata
18 FunctionalMatrix
19 TLVEXPRESSLIMITEDWARRANTY
20 Services

Aboutthisdocument EF200F-C
6
1 About this document
1.1 Document function
TheseOperatingInstructionscontainalltheinformationthatisrequiredinvariousphases
ofthelifecycleofthedevice:fromproductidentification,incomingacceptanceand
storage,tomounting,connection,operationandcommissioningthroughto
troubleshooting,maintenanceanddisposal.
1.2 Symbols
1.2.1 Safety symbols
Thissymbolalertsyoutoadangeroussituation.Failuretoavoidthissituationwillresultin
seriousorfatalinjury.
Thissymbolalertsyoutoadangeroussituation.Failuretoavoidthissituationcanresultin
seriousorfatalinjury.
Thissymbolalertsyoutoadangeroussituation.Failuretoavoidthissituationcanresultin
minorormediuminjury.
Thissymbolcontainsinformationonproceduresandotherfactswhichdonotresultin
personalinjury.
1.2.2 Electrical symbols
Symbol Meaning
Directcurrent
Alternatingcurrent
Directcurrentandalternatingcurrent
Groundconnection
Agroundedterminalwhich,asfarastheoperatorisconcerned,isgroundedviaa
groundingsystem.
ProtectiveEarth(PE)
Aterminalwhichmustbeconnectedtogroundpriortoestablishinganyother
connections.
Thegroundterminalsaresituatedinsideandoutsidethedevice:
• Innergroundterminal:Connectstheprotectivearthtothemainssupply.
• Outergroundterminal:Connectsthedevicetotheplantgroundingsystem.
DANGE
R
WARNING
CAUTION

EF200F-C Aboutthisdocument
7
1.2.3 Tool symbols
Symbol Meaning
Flatbladescrewdriver
Allenkey
Open-endedwrench
1.2.4 Symbols for certain types of information
Symbol Meaning
Permitted
Procedures,processesoractionsthatarepermitted.
Preferred
Procedures,processesoractionsthatarepreferred.
Forbidden
Procedures,processesoractionsthatareforbidden.
Tip
Indicatesadditionalinformation.
Referencetodocumentation.
AReferencetopage.
Referencetographic.
Noticeorindividualsteptobeobserved.
1. , 2. , 3. … Seriesofsteps.
Resultofastep.
Helpintheeventofaproblem.
Visualinspection.
1.2.5 Symbols in graphics
Symbol Meaning
1,2,3,... Itemnumbers
1. , 2. , 3. ,… Seriesofsteps
A,B,C,... Views
A-A,B-B,C-C,... Sections
Flowdirection

Aboutthisdocument EF200F-C
8
1.3 Documentation
ForanoverviewofthescopeoftheassociatedTechnicalDocumentation,refertothe
following:
Detailedlistoftheindividualdocumentsalongwiththedocumentationcode
→See16.15
1.3.1 Standard documentation
1.3.2 Supplementary device-dependent documentation
Additionaldocumentsaresupplieddependingonthedeviceversionordered:Always
complystrictlywiththeinstructionsinthesupplementarydocumentation.The
supplementarydocumentationisanintegralpartofthedevicedocumentation.
Documenttype Purposeandcontentofthedocument
InstructionManual
Planningaidforyourdevice
Thedocumentcontainsallthetechnicaldataonthedeviceand
providesanoverviewoftheaccessoriesandotherproductsthat
canbeorderedforthedevice.
TechnicalInformation
BriefOperatingInstructions Guidesyouquicklytothe1stmeasuredvalue
TheBriefOperatingInstructionsareaimedatspecialists
withresponsibilityforinstalling,configuringand
parameterizingthemeasuringdevice(untilthefirstmeasuredvalue).
• Incomingacceptanceandproductidentification
• Storageandtransport
• Installation
• Productdescription
• Electricalconnection
• Operationoptions
• Commissioning
• Diagnosticinformation
DescriptionofDeviceParameters Referenceforyourparameters
Thedocumentprovidesadetailedexplanationofeachindividual
parameterintheExpertoperatingmenu.Thedescriptionisaimedat
thosewhoworkwiththedeviceovertheentirelifecycleandperform
specificconfigurations.
(thisdocument)
Thisdocumentcontainsalltheinformationthatisrequiredin
variousphasesofthelifecycleofthedevice:fromproductidentifica-
tion,incomingacceptanceandstorage,tomounting,connection,
operationandcommissioningthroughtotroubleshooting,
maintenanceanddisposal

EF200F-C Safetyinstructions
9
2 Safety instructions
2.1 Requirements for the personnel
Thepersonnelforinstallation,commissioning,diagnosticsandmaintenancemust
fulfillthefollowingrequirements:
Trained,qualifiedspecialistsmusthavearelevantqualificationforthisspecific
functionandtask.
Areauthorizedbytheplantowner/operator.
Arefamiliarwithfederal/nationalregulations.
Beforestartingwork,readandunderstandtheinstructionsinthemanualand
supplementarydocumentationaswellasthecertificates(dependingonthe
application).
Followinstructionsandcomplywithbasicconditions.
Theoperatingpersonnelmustfulfillthefollowingrequirements:
Areinstructedandauthorizedaccordingtotherequirementsofthetaskbythe
facility'sowner-operator.
Followtheinstructionsinthismanual.
2.2 Designated use
Application and media
Themeasuringdevicedescribedinthismanualisintendedonlyforflowmeasurement
ofliquidswithaminimumconductivityof20µS/cm.
TheEF200F-Cvortexflowmeterisusedtomeasuretheflowofsaturatedsteam,
superheatedsteam,airandwater.Donotusetomeasuretheflowoftoxic,flammable
orotherwisehazardousfluids.
Toensurethatthemeasuringdeviceremainsinproperconditionfortheoperationtime:
Keepwithinthespecifiedpressureandtemperaturerange.
Onlyusethemeasuringdeviceinfullcompliancewiththedataonthenameplateand
thegeneralconditionslistedintheOperatingInstructionsandsupplementary
documentation.
Usethemeasuringdeviceonlyformediatowhichtheprocess-wettedmaterialsare
sufficientlyresistant.
Protectthemeasuringdevicepermanentlyagainstcorrosionfromenvironmental
influences.
Incorrect use
Non-designatedusecancompromisesafety.Themanufacturerisnotliablefordamage
causedbyimproperornon-designateduse.
Dangerofbreakageduetocorrosiveorabrasivefluidsandambientconditions!
Verifythecompatibilityoftheprocessfluidwiththesensormaterial.
Ensuretheresistanceofallfluid-wettedmaterialsintheprocess.
Keepwithinthespecifiedpressureandtemperaturerange.
Residual risks
Theelectronicsandthemediummaycausethesurfacestoheatup.Thispresentsa
burnhazard!
Forelevatedfluidtemperatures,ensureprotectionagainstcontacttopreventburns.
►
►
►
►
►
►
►
►
►
►
►
WARNING
►
WARNING
►
►
►

Safetyinstructions EF200F-C
10
2.3 Workplace safety
Forworkonandwiththedevice:
Weartherequiredpersonalprotectiveequipmentaccordingtofederal/national
regulations.
Forweldingworkonthepiping:
Donotgroundtheweldingunitviathemeasuringdevice.
Ifworkingonandwiththedevicewithwethands:
Duetotheincreasedriskofelectricshock,glovesmustbeworn.
2.4 Operational safety
Risk of injury.
Operatethedeviceinpropertechnicalconditionandfail-safeconditiononly.
Theoperatorisresponsibleforinterference-freeoperationofthedevice.
Conversionstothedevice
Unauthorizedmodificationstothedevicearenotpermittedandcanleadtounforeseeable
dangers.
If,despitethis,modificationsarerequired,consultwithTLV.
Repair
Toensurecontinuedoperationalsafetyandreliability,
Carryoutrepairsonthedeviceonlyiftheyareexpresslypermitted.
Observefederal/nationalregulationspertainingtorepairofanelectricaldevice.
UseoriginalsparepartsandaccessoriesfromTLVonly.
2.5 Product safety
Thismeasuringdeviceisdesignedinaccordancewithgoodengineeringpracticetomeet
state-of-the-artsafetyrequirements,hasbeentested,andleftthefactoryinaconditionin
whichitissafetooperate.
Itmeetsgeneralsafetystandardsandlegalrequirements.ItalsocomplieswiththeEU
directiveslistedinthedevice-specificEUDeclarationofConformity.
ProductconformityisindicatedbytheaffixationoftheCEmarktothedevice.
2.6 IT security
OurwarrantyisvalidonlyifthedeviceisinstalledandusedasdescribedintheOperating
Instructions.Thedeviceisequippedwithsecuritymechanismstoprotectitagainstany
inadvertentchangestothesettings.
ITsecuritymeasures,whichprovideadditionalprotectionforthedeviceandassociated
datatransfer,mustbeimplementedbytheoperatorsthemselvesinlinewiththeirsecurity
standards.
2.7 Device-specific IT security
Thedeviceoffersarangeofspecificfunctionstosupportprotectivemeasuresonthe
operator'sside.Thesefunctionscanbeconfiguredbytheuserandguaranteegreaterin-
operationsafetyifusedcorrectly.Anoverviewofthemostimportantfunctionsisprovided
inthefollowingsection.
►
►
►
►
►
►
►
►

EF200F-C Safetyinstructions
11
2.7.1 Protecting access via hardware write protection
Writeaccesstothedeviceparametersviathelocaldisplayoroperatingtool
canbedisabledviaawriteprotectionswitch(DIPswitchonthemotherboard).
Whenhardwarewriteprotectionisenabled,onlyreadaccesstotheparametersispossible.
2.7.2 Protecting access via a password
Apasswordcanbeusedtoprotectagainstwriteaccesstothedeviceparameters.
Thispasswordlockswriteaccesstothedeviceparametersviathelocaldisplayoranother
operatingtooland,intermsoffunctionality,isequivalentto
hardwarewriteprotection.
User-specific access code
Writeaccesstothedeviceparametersviathelocaldisplayoroperatingtool
canbeprotectedbythemodifiable,user-specificaccesscode(→See10.8.1).
Whenthedeviceisdelivered,thedevicedoesnothaveanaccesscodeandisequivalent
to0000(open).
General notes on the use of passwords
• Theaccesscodeandnetworkkeysuppliedwiththedeviceshouldbechangedduring
commissioning.
• Followthegeneralrulesforgeneratingasecurepasswordwhendefiningandmanaging
theaccesscodeornetworkkey.
• Theuserisresponsibleforthemanagementandcarefulhandlingoftheaccesscodeand
networkkey.
• Forinformationonconfiguringtheaccesscodeoronwhattodoifyoulosethe
password,seethe"Writeprotectionviaaccesscode"section→See10.8.1
2.7.3 Access via fieldbus
Cyclicfieldbuscommunication(readandwrite,e.g.measuredvaluetransmission)witha
higher-ordersystemisnotaffectedbytherestrictionsmentionedabove.

Productdescription EF200F-C
12
2.8 Vibrations
Thecorrectoperationofthemeasuringsystemisnotinfluencedbyplantvibrations
vibrationresistance(→see16.8)Consequently,thesensorsrequirenospecialmeasures
forattachment.Ifhigherlevelsofvibrationareexpected,besuretosecurepiping
beforeandaftertheflowmeter.
2.9 Preventing Excessive Flow
Toensurelongservicelifefortheflowmeter,excessiveinstantaneous/periodicalflow
ratesshouldbeheldbelowtheflowmeterʼsmaximumflowrate.Failingtodosomight
resultindamagetothesensor.Specialcareisnecessaryforsteamatstartupwhenthe
pressureislow,orwhenavalveisopenedrapidly,suchasbyasolenoidvalve,as
excessiveinstantaneousflowratesoftenoccur.
2.10 Pulsating Influences
Theabilityoftheflowmetertomeasurecorrectlymaybeadverselyaffectedifthereare
largevariationsofpressureorpulsatingpressurefromcompressorsand/orsootblow-
ers.Usetheproceduresbelowtominimizepulsatingpressures:
•Movethesourceofthepulsationstothedownstreamsideoftheflowmeter.Alterna-
tively,putasmuchdistanceaspossiblebetweenthesourceandtheflowmeter.
•Installapulsationdampeningdevice,suchasachamber.
•Closethevalvesbeforeandaftertheflowmeterwhenthereisnoflow.(Thisisto
preventfalsenon-zeroreadingsunderzero-flowconditions.)
2.11 Prevent Mixed Phase Flow
Thisflowmeterisdesignedtomeasurebothgasesandliquids.However,accurate
measurementcannotbeguaranteedwhengasesandliquidsaremixedtogether(i.e.
gas-liquidmixedphaseflow).
2.12 Ensure Pipe is Flooded
Whenmeasuringliquidsensurethatthepipeisflooded,asthiswillhaveaninfluenceon
theaccuracyofflowratemeasurements.
2.13 Bypass Lines
Theinstallationofbypasslinescanfacilitatemaintenanceandinspections.When
installingabypassline,useupstreamanddownstreamvalvesofatypethatdoesnot
disturbtheflowprofile,andsecuresufficientlengthofstraightpipe.

3 Product description
Thedeviceconsistsofatransmitterandasensor.
Twodeviceversionsareavailable:
• Compactversion‒transmitterandsensorformamechanicalunit.
• Remoteversion-transmitterandsensoraremountedinseparatelocations.
3.1 Product design
12
3456
78
9
+E
–
A0020649
Importantcomponentsofameasuringdevice
1 Electronicscompartmentcover
2 Displaymodule
3 Mainelectronicsmodule
4 Cableglands
5 Transmitterhousing(incl.HistoROM)
6 I/Oelectronicsmodule
7 Terminals(springloadedterminals,pluggable)
8 Connectioncompartmentcover
9 Sensor
EF200F-C Productdescription
13
1
A0034152
Versionsofpressuremeasuringunit
1 Ordercodefor"Sensorversion;DSCsensor;measuringtube",option"Masssteam"
Forordercodefor"Sensorversion;DSCsensor;measuringtube",option"Mass
steam",thefollowingapplies:Oil-freeorgrease-freecleaningisnotpossible

Incomingacceptanceandproductidentification EF200F-C
14
4
Incoming acceptance and product identification
4.1 Incoming acceptance
1
Arethegoodsundamaged?
Istheenvelopepresentwith
accompanyingdocuments?
Aretheproductsticker(1)
idential?
• Ifoneoftheconditionsisnotsatisfied,contactyourTLVSalesCenter.
• ContactTLVforTechnicalDocumentation.

EF200F-C Incomingacceptanceandproductidentification
15
4.2 Product identification
Thefollowingoptionsareavailableforidentificationofthedevice:
• Nameplatespecifications
• Ordercodewithbreakdownofthedevicefeaturesonthedeliverynote
ForanoverviewofthescopeoftheassociatedTechnicalDocumentation,refertothe
following:
4.2.1 Transmitter nameplate (compact version)
A0032237
1
F
1
2
3
5
4
6
7
1
2Nameofthetransmitter
3
Modelname
4
Serialnumber(ser.no.)
5
6
7
Permittedambienttemperature
Degreeofprotection
Permittedfluidtemperature
Powersupplyvoltage

Incomingacceptanceandproductidentification EF200F-C
16
4.2.2 Sensor nameplate (remote version)
1
2Nameofthetransmitter
3
Modelname
4
Serialnumber(ser.no.)
5
6
7
Permittedambienttemperature
Degreeofprotection
Permittedfluidtemperature
Powersupplyvoltage
Transmitter
1
2Nameofthetransmitter
3
Modelname
4
Serialnumber(ser.no.)
5
6
7
Permittedambienttemperature
Degreeofprotection
Permittedfluidtemperature
Powersupplyvoltage
Sensor
1
2
3
5
4
6
7
F
7
2
3
5
6
4
1
F

EF200F-C Incomingacceptanceandproductidentification
17
4.2.3 Nameplate for TEG (compact version/remote version)
Ordercode:
Ser.no.:
Ext.ord.cd.:
TTa+20K
skrowxe:WF
Date:
330820-0001B
O7F2C50-1234/56
S201EA19000
DC9...32V/2-wire
4-20mAHART
Pulse/freq./switchoutput
4-20mAInput
1xplug,1xsocketM12x1
Ta:-20...+60
V1.00.00
IP66/67Type4Xencl.
2021-02 A
VORTEXFLOWMETEREF200-C
Profile:3.02
1
6
2
3
4
5
1
2Nameofthetransmitter
3
Modelname
4
5
6
Electricalconnectionthread
Degreeofprotection
Powersupplyvoltage
Permittedambienttemperature

Storageandtransport EF200F-C
18
5 Storage and transport
5.1 Storage conditions
Observethefollowingnotesforstorage:
Storeintheoriginalpackagingtoensureprotectionfromshock.
Donotremoveprotectivecoversorprotectivecapsinstalledonprocessconnections.
Theypreventmechanicaldamagetothesealingsurfacesandcontaminationinthe
measuringtube.
Protectfromdirectsunlighttoavoidunacceptablyhighsurfacetemperatures.
Storeinadryanddust-freeplace.
Donotstoreoutdoors.
Storagetemperature:‒50to+80˚C(‒58to+176˚F)
5.2 Transporting the product
Transportthemeasuringdevicetothemeasuringpointintheoriginalpackaging.
A0029252
Donotremoveprotectivecoversorcapsinstalledonprocessconnections.They
preventmechanicaldamagetothesealingsurfacesandcontaminationinthe
measuringtube.
5.2.1 Measuring devices without lifting lugs
Centerofgravityofthemeasuringdeviceishigherthanthesuspensionpointsofthe
webbingslings.
Riskofinjuryifthemeasuringdeviceslips.
Securethemeasuringdeviceagainstslippingorturning.
Observetheweightspecifiedonthepackaging(stick-onlabel).
A0029214
WARNING
►
►
►
►
►
►
►

EF200F-C Storageandtransport
19
5.2.2 Measuring devices with lifting lugs
Specialtransportationinstructionsfordeviceswithliftinglugs
Onlyusetheliftinglugsfittedonthedeviceorflangestotransportthedevice.
Thedevicemustalwaysbesecuredattwoliftinglugsatleast.
CAUTION
►
►

Installation EF200F-C
20
6 Installation
6.1 Installation conditions
6.1.1 Mounting position
Mounting location
A0015543
Orientation
Thedirectionofthearrowonthesensornameplatehelpsyoutoinstallthesensor
accordingtotheflowdirection(directionofmediumflowthroughthepiping).
Vortexmetersrequireafullydevelopedflowprofileasaprerequisiteforcorrectvolume
flowmeasurement.Therefore,pleasenotethefollowing:
Orientation Compactversion Remoteversion
A Verticalorientation
A0015545
1)
B Horizontalorientation,transmitterheadup
A0015589
2)3)
C Horizontalorientation,transmitterheaddown
A0015590
4)5)
D Horizontalorientation,transmitterheadatside
A0015592
1) Inthecaseofliquids,thereshouldbeupwardflowinverticalpipestoavoidpartialpipefilling(Fig.A).
Disruptioninflowmeasurement!Inthecaseofverticalorientationanddownwardflowingliquid,thepipe
alwaysneedstobecompletelyfilledtoensurecorrectliquidflowmeasurement.
2) Dangerofelectronicsoverheating!Ifthefluidtemperatureis侒200˚C(392˚F),orientationBisnot
permittedforthewaferversion(EF200W-C)withnominaldiametersofDN100(4")andDN150(6").
3) Inthecaseofhotmedia(e.g.steamorfluidtemperature(TM)侒200˚C(392˚F):orientationCorD
4) Inthecaseofverycoldmedia(e.g.liquidnitrogen):orientationBorD
5) For"wetsteamdetection/measurement"option:orientationC
㾎㾎㾎㾎
㾎㾎㾎㾎
㾎㾎㾎㾎
4)
㾎㾎㾎㾎
Other manuals for EF200F-C
1
Table of contents
Other TLV Measuring Instrument manuals