Toa IC-100 Series User manual

TOA INSTITUTIONAL COMMUNICATION SYSTEM
IC-100 Series
System Specifications
CK-100B

SYSTEM DESCRIPTION
The TOA IC-100 Series is a microprocessor-controlled, fully electronic
institutional communication system specially designed to enhance
administrative efficiency in schools, correctional institutions or other
facilities.
The IC-100’s modular construction and flexible configuration facilitate
small-or large-system installation, maintenance, and system expansion
from a single line card supporting one control station and up to 15 sub-
stations, to 8 line cards for up to 8 control and 120 sub-stations per
exchange, with up to 9 tie-lined exchanges per multi-exchange system.
Using the optional CT-100, each exchange can have 2 outside lines, or
a C/O line and a PBX extension. The IC-100 can also be connected to
an external computer with the RS-232C port included on the MU-110
main control unit.
FEATURES
1. Modular construction for easy installation, maintenance and system
expansion.
2. Exchange unit may be rack- or wall-mounted.
3. Flexible configurations are available for a variety of applications,
from the smallest exchange configuration of 1 control station and
up to 15 sub-stations, to up to 8 control stations, and 120 sub-sta-
tions per exchange.
4. Two (2) outside (C/O) telephone lines, or one each of C/O line and
PBX (internal telephone) extension can be connected.
5. Tie-line capability, up to 9 exchanges, 72 control stations and 1,080
sub-stations.
6. RS-232C port for connection of a PC, for easy programming and
system maintenance.
7. Eight speech links (4 through tie-line) for full-duplex or voice switch
conversation.
8. Built-in programmable clock with 8 schedules x 32 events.
9. High fidelity Westminster Chime and 4-note chime.
10. Up to 60 (59 + all zone) zones can be established for paging, time
signal and program source output functions.
11. Random paging, time signal and program source broadcast pro-
gram for up to 10 sub-stations, 9 zones or 9 combination zones
12. External PA paging capability.
13. Convenient call forwarding, speed dialing, redialing, call transfer,
conference and transfer functions.
14. 5 calling priorities available.
15. 12-digit LCD display for calling/called numbers, time functions, pro-
gramming verification and sub-station mode.
16. Call queuing for up to 120 stations.
17. Message display on control station LCD display and an external
display.
18. Control station Duress Alarm.
19. Sub-station emergency status call.
20. Arbitrary stations can be assigned to each zone at random.
IC-100 SERIES EXCHANGE & STATIONS
1. MAIN SYSTEM EQUIPMENT
CK-100B Card Case
The CK-100B houses all system boards and can be installed in an
“EIA standard 19” rack.
MU-110 Main Control Unit
The MU-110 Main Control Unit uses a Z80 CPU to automatically
control speech path switching functions upon reception of either a
dial signal from the control station or a “call” or “privacy” signal from
any of the connected sub-stations. The MU-110 also generates time-
programmable signal tones. It provides external input/output controls
and a computer communication capability via its RS-232C port. The
MU-110 also provides the circuitry necessary to interface the DI-
100/DI-110 boards.
LU-100 Line Unit
The LU-100 contains interface circuitry for control station connection,
relay and talk-back, hybrid circuitry for sub-station connection, and a
speech path switch. The control station interface outputs a dial sig-
nal to the Main Control Unit when it receives a control station dial
signal. Other control station functions include FM signal demodula-
tion, sound amplification and power supply control for control station
and sub-station speaker talk-back capability. One control station and
up to 15 sub-stations can be connected per Line Unit. The sub-sta-
tion interface features an AGC-equipped 15W power amplifier (25V
line) for sub-station speaker talk-back, relayed switching of up to 15
sub-stations, photocoupled reception of “call” and “privacy” signals,
and hybrid circuitry for sub-station handset operation.
LU-200 Line Unit
The LU-200 contains interface circuitry for a control station, and a
speech path switch. Control stations include FM signal demodula-
tion, sound amplification, and talk-back capability. Only one control
station can be connected per LU-200.
PS-100 Power Supply Unit
The PS-100 receives AC power from the PU-200 Power Transformer
Unit, and provides 5V, 15V and 24V DC power to all other boards in
the exchange via its rectification and stabilizer circuitry. DC input is
also provided for an optional standby battery and charging circuit,
that ensures full operating capability in case of a power failure.
PU-200 Power Transformer Unit
The wall-mountable PU-200 provides two 20V/2AAC outputs to the
PS-100 Power Supply Unit to drive up to four LU-100 Line Units. A
maximum of two PU-200s can be connected to the PS-100.
2. OPTIONAL SYSTEM EQUIPMENT
CT-100 Telephone & Tie-Line Unit
The CT-100 Telephone & Tie-Line Unit functions as an interface for
both an outside telephone line and an exchange tie-line. Its C/O
telephone line interface is compatible with both loop and ground
start systems. It uses DTMF dialing signals for each of its 2 outside
lines, or one C/O line and one PBX extension. The CT-100 complies
fully with FCC Parts 68 regulations, The tie-line interface permits
interconnecting of up to 9 exchanges, with 4 voice paths, 1 program
I/O, and 1 control I/O.
DI-100/Dl-110 Interface Boards
The Interface Boards allow a control station operator to make or
receive calls from other stations via a single switch on a custom or
off-the-shelf control panel. Calls to or from corresponding sub-sta-
tions can be announced by flashing LED’s on the control panel, or
by numbers shown on the displays of associated AS-100A or AS-110
control stations.
PN-100 Rack Mount Panel
The PN-100 provides side-by-side rack mounting capability for up to
two PU-200 Power Transformer Units.
YC-300 Wall Mounting Frame
The YC-300 is used to mount the CK-100 Cards Case to a wall sur-
face.
3. MASTER CONTROL AND SUB-STATION CONTROL
AS-100A Control Station
The AS-100A Control Station provides full-duplex communication
with other control stations and sub-stations via its handset unit. It
also features “hands free” communication, and a 12-digit display of
the contacting/cd room number, the dialed number, sub-station prior-
ity status, a digital clock, and other indicators. The AS-100A utilizes
a 4-pin modular telephone connector.
AS-110 Control Station
A flush-mount version of the AS-100A, this control station can be
mounted in a console or on a wall.
RS-100 Switch Panel
The RS-100 Switch Panel mounts two switch buttons, a red “call”
button and a white “privacy” button, to control an RS-110 Handset or
a remote speaker. This flush-mount panel can be installed in a stan-
dard 1-gang electrical box and connected via a single-pair shielded
cable.
RS-110 Sub-Station Handset
The RS-110 Sub-Station Handset provides full-duplex communica-
tion with the Control Station. The wall-mount cradle can be installed
in a standard 2-gang electrical box and connected via a single-pair
shielded cable.
RS-150 Economy Sub-Station
The RS-150 Economy Sub-Station includes a heavy-duty faceplate,
call switch, loudspeaker and matching transformer.
RS-160 Indoor Sub-Station
The RS-160 Indoor Sub-Station includes a heavy-duty faceplate,
vandal-resistant call switch, loudspeaker and matching transformer.
RS-170 Outdoor Sub-Station
The RS-170 Outdoor Sub-Station is weather-resistant and includes a
heavy-duty faceplate, vandal-resistant call switch, loudspeaker and
matching transformer.
RS-180 Panic Sub-Station
The RS-180 Panic Sub-Station is weather-resistant and includes a
heavy-duty faceplate, vandal-resistant call switch, loudspeaker, match-
ing transformer, red call LED, red call button and control output.

FUNCTIONS
1. Conversation
Call from a Sub-Station
Pressing the RS-100 switch panel CALL switch or picking up the sub-station
handset initiates a call-in to the control station, indicated by a flashing LED
on the switch panel.
Pressing the PUSH-TO-TALK switch or picking up the AS-100A or AS-110
control station handset enables conversation, with the LED indicator fully on.
Conversations through the sub-station speaker are automatic half-duplex
with the voice switch and manual half-duplex with the PUSH-TO-TALK
switch. Sub-station handset conversations are full-duplex, converting to half-
duplex when the PUSH-TO-TALK switch is used.
The LED indicator goes off at the end of a conversation.
Pressing the CALL switch continuously for more than 3 seconds initiates an
emergency call to the control station, setting off the emergency status dis-
play at the control station.
Call from a Control Station
Dialing a station number with the keypad initiates a calling tone and sets up
a voice link. Hands-free conversation is half-duplex when the PUSH-TO-
TALK switch is used, and automatic with the voice switch.
Pressing the [#/C] key or replacing the handset terminates the conversation.
2. Display
The AS-100A/AS-110 control station is equipped with a 12-digit LCD display
for the calling party’s station number and priority level, or the numbers of the
stations on hold. Holding station capacity is 120 per system. Current time,
control station privacy status, time schedule status, sub-station mode dis-
play or a message from a personal computer can be displayed while the
control station is on-hook (in idle status).
3. Privacy
Pressing the RS-100 switch panel PRIVACY switch puts the sub-station in
privacy mode and causes the privacy LED to go on. In privacy mode,
incoming calls are refused. The sub-station can still be called, but sub-sta-
tion conversations cannot be heard. Pressing the switch again cancels the
privacy mode. Pressing the [*] key on a control station twice puts it into pri-
vacy mode, causing incoming calls from other control stations to be refused.
Pressing [*] and [#/C] cancels the privacy mode.
4. Alert Tone
While a control station and a sub-station are connected, a periodic alert tone
can be sent to the stations to prevent sub-station conversations from inad-
vertently being overheard by the control station.
5. Time-Out
Conversation, sub-station calling, paging and PBX conversation can be
automatically reset within a programmable time frame.
6. Priority
Five levels of priority can be established for all individual station calls, dis-
played in the following order: (1) Emergency (2) Priority (3) Alarm (4)
Normal (5) Staff.
7. Paging
Sub-Station Paging
Permits simultaneous paging of up to 10 individual sub-stations.
Zone Paging
Permits simultaneous paging of pre-programmed combinations of sub-sta-
tions in zones. Up to 60 zones (59 zones + all zones) can be established,
regardless of the number of tie-lined exchanges.
Combination Zone Paging
Permits simultaneous paging of pre-programmed combinations of zones. Up
to 9 combinations can be established, regardless of the number of tie-lined
exchanges.
All-Call Paging
Permits simultaneous paging through all the stations assigned to all zones
and external PA speakers.
Emergency All-Call Paging
Takes precedence over all other functions to permit simultaneous paging
through all the stations assigned to all zones and external PA speakers
assigned to all-call.
External Microphone All-Call Paging
All-Call paging can be performed from a connected external microphone
after activation with an external switch.
PA Paging
Permits All-Call or zone paging through a connected external PA system. An
auxiliary selection device can control PA zone selection output, making up to
three different PA zones possible.
8. Program Source Output
Permits broadcast of a selectable program source to individual sub-stations,
zones, combination zones and all zones.
9. Time Signal
Permits broadcast of time signals to individual sub-stations, zones, combina-
tion zones, and all zones. Time signals can either be automatically output at
preset times using the system’s programmable clock, six external time sig-
nal trigger inputs, or manually output from a control station.
The programmable clock permits programming of 8 separate 32-event
schedules.
Schedules can be selected at the control station. Built-in time signals are (1)
an FM quality, high-fidelity generation of the Westminster Chimes, and (2) a
‘trill tone’. Provision exists for input of up to 3 alternate, user-supplied tones.
An external bell relay can be driven either by itself, or in conjunction with
any tone or tone input.
10. Call Transfer
Calls between control stations or to a sub-station can be transferred to a
third station.
11. Call Forwarding
All calls to a control station can be automatically forwarded to any other
locally pre-designated control station. This function can also be used to for-
ward calls to/from the external C/O telephone lines.
Auto-Call C/O Transfer
This function permits handset sub-station calls to a control station registered
for this function to be automatically forwarded to a programmed C/O tele-
phone number. The auto-call C/O transfer function can be operated in one
of two ways, either directly by a control station, or by external make-contact
inputs typically controlled by an external timer, etc.
Control Station Group Call (Selectable Function)
All control stations pre-programmed for the same group can be called simul-
taneously from a sub-station. Up to 8 groups of 8 stations each can be pro-
grammed.
12. Speed Dialing
Up to ten station, telephone or paging numbers can be registered for con-
venient speed dialing.
13. Redialing
The last number dialed at a control station can be automatically re-dialed
with a touch of the REDIAL key.
14. Conference
Calls can be made from a control station to up to two other control or sub-
station numbers.
15. External Telephone (C/O) Line Communication
Up to 2 external telephone Iines can be connected to the exchange via the
CT-100 C/O & Tie-Line Unit. External-line incoming or outgoing call capabili-
ty can be independently assigned to all control stations
PBX Extension Communication
All stations can access the PBX using the CT-100 C/O & tie-line card. The
CT-100 features two outside C/O line terminals which can be registered for
either C/O line or PBX extension use by system programing. Only one out-
side C/O Iine terminal may be connected to the PBX extension
16. Personal Computer Connection
The exchange can be connected to an external personal computer via the
RS-232C connector attached to the MU-110 Main Control Unit. System pro-
gramming and maintenance can then be easily performed at the computer’s
keyboard, with password protection.
17. Message Display
Messages input at the connected computer can be output at the control sta-
tion LCD display, and acknowledgments in turn displayed on the computer
monitor.
18. Tie-Line Connection
Up to 9 exchanges can be interconnected using the CT-100 C/O & Tie-Line
Board to provide extended communication capability to a maximum of 72
control stations and 1,080 sub-stations. The maximum number of 60 pro-
grammable zones and 9 combination zones remains limited to 9 each,
regardless of the number of interconnected exchanges
19. Duress Alarm
The Control Station can be pre-programmed to automatically transmit an
emergency status call to all other control stations when the handset is
removed from the cradle and a call or page is not started within 6 seconds.
The control station in emergency can then be called by another control sta-
tion, whether or not the handset of the control station in emergency has
been replaced.
20. Emergency Call
Any Sub-StatIons can be pre-programmed to automatically transmit an
emergency status call to the designated control station when the “Call” but-
ton is pressed and held for three seconds.
21. Direct Select Interface
With the use of DI-100 or DI-110 Interface Boards, calls may be made or
received from other stations at the touch of a single control panel switch.
Call announcements are shown by flashing control panel LEDs or AS-100A/
AS-110 alphanumeric displays.
22. Off-Hook Indication
Any RS-110 handset left off-hook after conclusion of the conversation wiII
be indicated on the AS-100A/AS-110 LCD display.
23. Busy/Privacy Status Indication
The AS-100A/AS-110 LCD display wiII indicate the busy or privacy status of
called stations.
24. Scan Monitor
Any control station can scan an arbitrary group of sub-stations (in consecu-
tive order) for auditory monitoring of each sub-station at a pre-set time inter-
val.

CT-100
Telephone & Tie Line Unit
Main System Equipment
CK-100B Card Case
PU-200 Power Transformer Unit
MU-110
Main Control Unit LU-100
Line Unit LU-200
Line Unit PS-100
Power Supply Unit
DI-100
Interface Board
PN-100 (optional)
Rack Mounting Panel for PU-200
YC-300 (optional)
Wall Mounting Kit for CK-100B
DI-110
Interface Board

Master Control and Room Station Equipment
AS-100A
Control Station
SYSTEM CONSTRUCTION TABLE
Sample System SET 1 SET 2 SET 3 SET 4 SET 5
No. of Sub-Stations 1-15 max. (N)*1 1-15 max (N)*1 1-15 max (N)*1 1-60 max (N)*1 1-120 max (N)*1
No. of Control Stations 1 max. 1 max. 1 max. 4 max. 8 max.
C/O Lines 0 0 2 max. 2 max. 2 max.
Equipment:
CK-100B 1 1 1 1 1
YC-300 0 1 0 0 0
PU-200 1 1 1 1 2
PN-100B 1 0 1 1 1
MU-110 1 1 1 1 1
LU-100 1 1 1 4 8
PS-100 1 1 1 1 1
CT-100 0 0 1 1 1
AS-100A or AS-110 1 max. 1 max. 1 max. 4 max. 8 max.
RS-100, RS-150/160/170/180 15 max. 15 max. 15 max. 60 max. 120 max.
Room Speakers (N) (N) (N) (N) (N)
SET 1 15 sub-stations—Rack mounting type without C/O line
SET 2 15 sub-stations—Wall mounting type without C/O line
SET 3 15 sub-stations—Rack mounting type with C/O line
SET 4 60 sub-stations—Rack mounting type with C/O line
SET 5 120 sub-stations—Rack mounting type with C/O line
*1 N is the number of sub-stations
AS-110
Control Station RS-100
Switch Panel
Call
Privacy
RS-110
Handset
RS-150
Economy Sub-Station
"
"
"
"
"
"
"
RS-160
Indoor Sub-Station
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
RS-170
Outdoor Sub-Station RS-180
Panic Sub-Station

Exchange Method Space division
Control Method Common stored program control
Call Method Speaker-output call signal or voice
Conversation Method Voice Switch or PTT-activated talk-back,
or full-duplex handset communication
Dialing System AM-modulated pulse number transmission
(control station), and current loop transmis-
sion (sub-station) systems
Station Line Capacity Max 8 sets of 1 control station & 15 substations
per exchange
C/O Line Capacity Max. 2 outside telephone (C/O) lines or one
(PBX Extension Capacity) each of C/O line and PBX extension per
exchange
Link Capacity 8
Station No. Schedule No. 00-99 (2-digit)
No. 000-999 (3-digit)
No. 0000-9999 (4-digit)
Signal Tones Call/Busy/Hold/Page/Time/(Others)
Wiring Control station: 2 twisted pairs
Sub-station: 1 twisted pair. shielded
Cable Length Control station: 4,800 ft. (1,464m); 22AWG
Sub-station: 2,800 ft. (854m); 22AWG
Speaker Output 1W (25V line)
C/O Line Start signal: Loop or Ground start
Dialing signal: DTMF
Tie Line Link Capacity: 4
Connection: Multi-drop
Number of lines: Voice lines—8 pairs
Program lines—1 pair
Data lines—1 pair
Power Requirements AC MAINS 50/60Hz
Backup battery: 24 VDC ± 10%
Power Consumption Max.: 250W, (at All-call to 120 sub-stations)
Min.: 40W, (at Stand-by configuration with 120
sub-stations)
Operating Temperature 32°to 104°F (0°to 40°C)
Dimensions (W x H x D) 14.0 x 16.6”x 10.4”(355 x 420 x 263mm)
Weight 35.3 lbs (16kg)
Case Material Zinc-plated steel
Finish Front panel: Noland Gray Enamel
Case: Dark Gray Enamel
*Specifications are subject to change without notice.
SPECIFICATIONS SAMPLE SYSTEM CONFIGURATION
PN-100B
IC-100 (1)
IC-100 (2)
IC-100 (9)
MU-110
CT-100
PS-100
LU-100 (1)
(supports
one control
station and
up to 15
sub-stations)
LU-100 (2)
LU-100 (8)
CK-100B/YC-300
PU-200
DI-100/110
PU-200
RS-232
Control & Monitoring
NOTE: shows optional units used according to job requirements
RS-100 RS-110
AS-110
OR
RS-150/160/170/180
RS-100
RS-102 RS-110
speaker station
paging amplifier
camera
controller or
graphic panel
Custom Station Types
AS-100A
TOA Electronics, Inc.
Phone: 800-733-7088 Fax: 800-733-9766
Web Site: www.toaelectronics.com
TOA Canada Corp.
Phone: 905-564-3570 Fax: 905-564-3569
Other manuals for IC-100 Series
5
Table of contents