Topway Tewaycell TW-MB-51300-100A-HBW User manual

SHENZHEN TOPWAY NEW ENERGY CO., LTD.
15KWH Mobile ESS Battery
Product instruction

1/22
www.tewaycell.com
Catalogue
1. Safety tips ........................................................................................................................................2
1.1 Preface .................................................................................................................................. 2
1.2 Safety disclaimer .................................................................................................................. 2
1.3 Description of safety matters ................................................................................................2
2 Product description .......................................................................................................................... 3
2.1 Product dimension ................................................................................................................ 3
2.2 Product details ...................................................................................................................... 4
2.3 Electrical schematic diagram ................................................................................................6
2.4 Parallel Connection Diagram ............................................................................................... 7
3 Technical specifications ...................................................................................................................8
4 BMS characteristics ......................................................................................................................... 9
4.1 Instructions for LED lights ...................................................................................................9
4.1.2 SOC capacity indicator ..............................................................................................9
4.2 Boot and sleep mode ...........................................................................................................12
4.3 Communication area ...........................................................................................................12
5 Operating instructions ....................................................................................................................14
5.1 Operating instructions of the display screen ...................................................................... 14
5.1.1 Introduction of LCD Display .................................................................................. 14
5.1.2 Boot screen .............................................................................................................. 14
6 Product list and tools ..................................................................................................................... 20
6.1 Product packing lists ...........................................................................................................20
6.2 Prepared tools and instruments .......................................................... 错误!未定义书签。
7 Instruction manual ....................................................................................................................... 21

2/22
www.tewaycell.com
1. Safety tips
1.1 Preface
Thanks for choosing Topway New Energy power wall battery. In order to make you
better use and maintain this product, please read the user manual carefully before use.
The features of this product are as follows:
1. Adopt brand new lithium iron phosphate cell; Higher security; In the standard state, 100%
DOD charge-discharge ≥4000 times cycle;
2. Highly integrated analog front end; Isolating power supply circuit;
3.
Integrated serial port IC, high voltage accuracy (≤20mV), high current accuracy
(≤2%@FS);
4. Four-channel battery temperature detection (≤2℃), SOC estimation function, SOH
estimation function;
5. Short-circuit protection function, adjustable overcurrent protection, a variety of sleep and
wake up mode, low power consumption;
6. Dual-port RS485 communication, parameter adjustable setting, buzzer alarm function,
LED status indicator function, with charge balance power;
7.
Wide temperature range: -20℃~60℃;
8.
Parallel connection (up to 15 groups) application expansion is supported, but serial
connection is not recommended.
1.2 Safety disclaimer
When installing, using and maintaining this product, users must read this chapter
carefully and follow the safety precautions required in this chapter. Any injuries and losses
caused by illegal operation are not related to our company.
1.3 Description of safety matters
1. Keep the battery out of the reach of children and babies;
2. Do not put the battery in the oven or other similar equipment;
3. Do not remove the product label;
4. Do not try to open the battery pack;
5. Do not be exposed to the environment above 60℃(300F);
6. Do not short-circuit the positive and negative terminals of the battery with wires or other
metal objects. Do not transport or store batteries with metal objects;
7. Do not expose the battery to direct heat or flame. Do not use or store batteries near fire or
high temperature;
8. Do not immerse the battery in water, salt water or any other liquid or make it wet;
9. Do not pierce the battery with any sharp object, knock it with a hammer or similar device,

3/22
www.tewaycell.com
step on it, fall it or get strong vibration;
10. Do not use the battery if it is damaged or deformed;
11. If the battery produces odor, smoke or abnormal heat, please stop using it immediately;
12. If the battery liquid leaks and comes into contact with your eyes, please don't rub your
eyes, and immediately rinse them with plenty of water before seeking medical assistance.
2 Product description
2.1 Product dimension

4/22
www.tewaycell.com
2.2 Product details
Display screen
Function buttons

6/22
www.tewaycell.com
2.3 Electrical schematic diagram
picture1 Electrical schematic diagram

7/22
www.tewaycell.com
2.4 Parallel Connection Diagram
Support up to 15 batteries in parallel.
Picture 2 Parallel connection diagram

8/22
www.tewaycell.com
3 Technical specifications
Table 1 Technical specification table
No.
Project
Specifications
1
Model
TW-MB-51300-100A-HBW
TW-MB-48300-100A-HBW
2
Nominal
capacity
3
Nominal voltage
51.2V
48.0V
4
Charging
voltage
56.8-57.6V
53.2-54V
5
Operating
voltage
44.8V~56.8V
42.0V~53.2V
6
Charging
current
Charging standard: 0.2C
Fast charging: 0.33C
7
Standard
charging mode
At a temperature of 0°C to 45°C, charge to 54.75V with a constant
current of 0.2C5A, and then change continuously with a constant
voltage of 54.75V until the current is not greater than 0.02C5A.
8
Maximum
charging current
100A
9
Maximum
discharge
current
100A
10
Charging
temperature
0°C to 45°C (32°F to 113°F) @60±25% relative humidity
11
Discharge
temperature
-20°C to 60°C (-4°F to 140°F) @60±25% relative humidity
12
Storage
temperature
-0°C to 45°C (32°F to 113°F) @60±25% relative humidity
13
Measure
900*520*300mm
14
Line joint
120A Self-Locking Fitting Quick Release Connector
15
Weight
136Kg
127.5Kg
16
Communication
protocol
RS485、RS232、CAN
17
Support inverter
brand
Growatt、Deye、Goodwe、Voltronic power、Sofar、VICTRON、
Solis、Megarevo、SRNE

9/22
www.tewaycell.com
4BMS characteristics
4.1 Instructions for LED lights
Picture 3 Battery indicator lamp
Four green capacity indicators, a red alarm indicator, a green running indicator and a switch
indicator.
4.1.2 SOC capacity indicator
Table 2 SOC indicator status table
Condition
Charge
Discharge
Capacity indicator
lamp
L1
L2
L3
L4
L1
L2
L3
L4
power
(%)
0~25%
Flash
2
OFF
OFF
OFF
ON
OFF
OFF
OFF
25~50%
ON
Flash
2
OFF
OFF
ON
ON
OFF
OFF
50~75%
ON
ON
Flash
2
OFF
ON
ON
ON
OFF
75~100~
ON
ON
ON
Flash
2
ON
ON
ON
ON
Running indicator
light
ON
Flash 3
4.1.3 Status indicator

10 /22
www.tewaycell.com
Table 3 Status indicator status table
Status
Warning/Normal/
Protection
ON/OF
F
Run
Alert
LED Battery Level
Indicator
Explain
●
●
●
●
●
●
●
Shut
down
Sleep mode
ON
OFF
OFF
OFF
OFF
OFF
OFF
Light off
Standby
Normal
ON
Flash
1
OFF
According to the electricity
indication
Standby mode
Warning
ON
Flash
1
Flash
3
Module low voltage
charge
Normal
ON
ON
OFF
According to the power
indicator (the maximum
LED of the power indicator
flashes 2)
The maximum power
LED flashes (flash
2),and the ALM does
not flash during the
overshoot.
Warning
ON
ON
Flash
3
Overcharge
Protection
ON
ON
OFF
ON
ON
ON
ON
If there is no mains
supply,the indicator
turns to standby
Temperature,over
current,failure,
protection
ON
OFF
ON
OFF
OFF
OFF
OFF
Stop charging
discharge
Normal
ON
Flash
3
OFF
According to the electricity
indication
Warning
ON
Flash
3
Flash
3
UVLO
ON
OFF
OFF
OFF
OFF
OFF
OFF
Stop discharge
Temperature,
over current,
short out,
reversed
polarity ,FAIL-S
AFE
ON
OFF
ON
OFF
OFF
OFF
OFF
Stop discharge
Invalid
OFF
OFF
ON
OFF
OFF
OFF
OFF
Stop charging and
discharging

11 /22
www.tewaycell.com
Table 4 LED flashing description
Flashing mode
ON
OFF
Flash 1
0.25s
3.75s
Flash 2
0.5s
0.5S
Flash 3
0.5s
1.5s

12 /22
www.tewaycell.com
4.2 Boot and sleep mode
Sleep mode: the battery will be in sleep mode if any of the following conditions are met
1) The battery or battery pack over discharge protection lasts for 30 seconds and is not
released.
2) Press the power on / off button for 3 seconds and release.
3) The minimum voltage of the battery is lower than the "sleep voltage" setting in the
setting, without charging and discharging.
4) Standby for more than 24 hours without charging and discharging.
5) Switch to the upper computer for sleep manually.
Wake up: the battery will exit sleep mode if any of the following conditions are met
1) Charger is plugged in;The charger voltage is greater than 48V.
2) Press the power on / off button for 3 seconds and release.
3) Plug in the communication cable and open the upper computer software (not
available if it is under over discharge protection).
Note: if over discharge protection is enabled, the battery will be in sleep mode. The
battery will wake up automatically every 4 hours and turn on the charge / discharge MOS. If
charging is available, the battery will be charged, otherwise it will return to sleep mode. If it
has been awakened 10 times but cannot be charged, the battery will not wake up again
automatically.
4.3 Communication area
Picture 4 Communication interface diagram
1. RS232: BMS can communicate with upper computer through RS232 interface, so as to
monitor various information of battery, including battery voltage, current,temperature,
status and battery production information, etc. the default baud rate is 9600bps.
2. RS485: with dual RS485 interface, you can view the information of pack. The default
baud rate is 9600bps.If it is necessary to communicate with the monitoring equipment
through RS485, the monitoring equipment is used as the host, polling data according to
the address, and the address setting range is 1 ~ 15.
3. CAN: CAN communication, baud rate 9600bps.
4. DCT:dry contact interface.

13 /22
www.tewaycell.com
5. ADS: dial switch
6. Rst: reset button

14 /22
www.tewaycell.com
5 Operating instructions
5.1 Operating instructions of the display screen
5.1.1 Introduction of LCD Display
Button Description:
MENU: enter the management system.
Enter: enter the submenu.
Down: moves the cursor down or to the next page.
ESC: returns to the previous one
5.1.2 Boot screen
Battery protection status:
Overvoltage: OV
Low voltage: LV
Overtemperature: OT
Low temperature: IT
Over current: OC
Short circuit: SC
Note:when the battery is protected,the corresponding
protection status will be displayed; otherwise,the
protection status will not be displayed as the protection
state.

15 /22
www.tewaycell.com
1Press “MENU” to enter the main menu
Note:“》”indicates that there is a submenu. Press”ENTER” to enter the submenu
2Move the cursor to “Analog info” and press “Enter”
Move the cursor to "Temperature" and press "Enter" to check the battery temperature
information, then press "DOWN" to turn the page
Analog Info
》
BMS Status
》
Para Setting
》
Sys Setting
》
Pack V
Im
Temperature
》
Cell Voltage
》
T1
XX℃
T2
XX℃
T3
XX℃
T4
XX℃
PCB-T
XX℃
ENV-T
XX℃

16 /22
www.tewaycell.com
Move the cursor to "Cell Voltage" and press "Enter" to check the battery voltage
information, then press "Down" to turn the page
Move the cursor to “CellCapacity” and press “Enter” to check the battery capacity
information
SOC
X%
FCC
XAH
Rm
XAH
CC
0
Cell 01
xxxxmV
Cell 02
xxxxmV
Cell 03
xxxxmV
Cell 04
xxxxmV
Cell 05
xxxxmV
Cell 06
xxxxmV
Cell 07
xxxxmV
Cell 08
xxxxmV
Cell 09
xxxxmV
Cell 10
xxxxmV
Cell 11
xxxxmV
Cell 12
xxxxmV
Cell 13
xxxxmV
Cell 14
xxxxmV
Cell 15
xxxxmV

17 /22
www.tewaycell.com
3Move the cursor to “BMS Status”, press “Enter” to check the battery status, and
press “▼” to turn the page
Move the cursor to "Record", then press "Enter" to check the battery alarm
information, then press "DOWN" to turn the page.
Status
IDLE/DISCHG/
CHARGE/FULL
Record
》
BMS Status
》
SCP
0/UTP
0CP
UVP
0VP

18 /22
www.tewaycell.com
Move the cursor to "BMS Status", then press "Enter" to check the battery protection
information, and then press "DOWN" to turn the page.
4Move the cursor to "Para Setting" and press “Enter”to check the gyroscope
information, then press "▼" to turn the page.
UV
Y/N
UVP
Y/N
OC
Y/N
OCP
Y/N
OT
Y/N
OTP
Y/N
OV
Y/N
OVP
Y/N
SCP
Y/N
Failure
Y/N

19 /22
www.tewaycell.com
5Move the cursor to "Sys Setting", then press “Enter” to check the version
information, and then press "▼" to turn the page.
6Hibernation and activation functions
After 1 minute of button-free operation in normal operation, the display will turn off
(backlight only), and pressing any button while the screen is off will allow the screen
to light up and function normally.
This manual suits for next models
1
Table of contents
Popular Batteries Pack manuals by other brands

Livoo
Livoo TEA308 user manual

Lowell power
Lowell power UPS-XBP Series User & installation manual

Sunamp
Sunamp Thermino 20 Installation and user manual

Fosmon
Fosmon C-10729 quick start guide

Mitsubishi Electric
Mitsubishi Electric BC16 Installation, operation & maintenance manual

Iluv
Iluv myPower 2500 quick start guide