CalibratingtheSensor
Note:Whenyourstturntheignitionkeytoon,
theInfoCentershowsadvisory194,CalibrateSlope
Sensor.
1.Whileonaatsurface,removetheplugfrom
thecalibrationconnectors(Figure7).
g317369
g317368
Figure7
1.Calibrationconnectors2.Plug
2.Plugthecalibrationconnectorstogetheras
showninFigure7.
3.TurntheignitionkeytotheONposition,butdo
notstarttheengine.
4.TheInfoCentershowsadvisory195,Slope
SensorCalibrating.
Note:TheLEDlightatthetopofthedisplay
screen(Figure8)blinksasthesensorcalibrates.
g317524
Figure8
1.LEDlight
5.WhentheInfoCentershowsadvisory196,Slope
SensorCalibrated,andthelightnolongerblinks,
turntheignitionkeytotheOFFposition.
6.Disconnectthecalibrationconnectorsandinstall
theplugontotheconnectors(Figure9).
g315597
Figure9
1.Calibrationconnectors2.Plug
UpdatingtheMachine
Software
Checkandensureyourmachinesoftwareisat
revisionWorhigher.ContactyourauthorizedT oro
distributortoupdatethemachinesoftware.
5