Torus Power AVR ELITE Series User manual

AVR ELITE Series Owner’s Manual
O

Torus Power toroidal isolation transformers dramatically improve the performance of all audio and video
systems. Connect audio equipment to a Torus Power isolation transformer and it comes alive - with more
dynamics, improved imaging, and cleaner, enhanced bass. Video is crisper, with darker blacks, and brighter
colours. Torus Power toroidal isolation transformers are the consistent choice of knowledgeable
audiophiles, home theater enthusiasts, custom electronic system integrators and designers, whose
discriminating tastes and technical requirements mandate the ultimate performance and protection levels
achievable.
Power system design and custom integration using Torus is effortless, due to the wide range of models,
power ratings, chassis types, mounting choices, and control options, which include a local web browser
interface and remotely via the cloud-based Torus Power Connect service.
Virtually all power line noise artifacts are eliminated through the toroidal isolation transformer, using
patented Narrow Bandwidth Technology. The toroidal isolation transformer provides high levels of
instantaneous current, making sure even dynamic components (such as high power amplifiers) are never
starved for power. It’s like having a clean power source directly adjacent to the plugged-in components.
Torus Power isolation transformers also protect connected equipment from potentially damaging AC power
line events, including severe lightning strikes and brownouts, thereby increasing system reliability, and
extending product life.
Precision engineered, with more than 30 years of experience, and an unparalleled reputation, Torus Power
is manufactured under ISO9001: 2008 quality management system in Canada. Whether you are a music
lover with a mid-level system, a dedicated audiophile, a home theater enthusiast, a custom designer,
installer or integrator specifying power systems for home, studio, stadium, or commercial applications, a
Torus Power isolation transformer will provide the ultimate clean power source solution.
Cover page photos show the TOT AVR ELITE 10 and AVR ELITE 20 North American models.

Table of Contents
IMPORTANT SAFETY INSTRUCTIONS ............................................................................................................................1
Shipping Carton & Packing Material.............................................................................................................................3
Placement & Ventilation...............................................................................................................................................3
Warranty.......................................................................................................................................................................3
Torus Power AVR ELITE SERIES Overview.....................................................................................................................4
Front Panel Display .......................................................................................................................................................5
Voltage Fault Protection...............................................................................................................................................6
Component Connections..............................................................................................................................................8
Rear Panel Connections................................................................................................................................................9
Specifications..............................................................................................................................................................10
North American Models ...................................................................................................................................10
International Models........................................................................................................................................11
Circuit Schematics.......................................................................................................................................................12
AVR ELITE Embedded Software ..................................................................................................................................15
Username and Password..................................................................................................................................15
AVR ELITE Menu Selections..............................................................................................................................16
Torus Power Connect .................................................................................................................................................20
User Registration ..............................................................................................................................................21
Device Registration (applies to Self Registered Users only).............................................................................21
User Menu ................................................................................................................................................22
System Status ...........................................................................................................................................22
Live Data ...................................................................................................................................................23
Power Control...........................................................................................................................................24
System Setup ............................................................................................................................................25
Historical Charts .......................................................................................................................................27
Historical Data ..........................................................................................................................................29
Schedule ...................................................................................................................................................31
Report .......................................................................................................................................................33
Personal Information................................................................................................................................34
Document Revision
Date
1.0
10/20

1 | Page
IMPORTANT SAFETY INSTRUCTIONS
CAUTION! To reduce the risk of electric shock and fire, do not remove the cover of this device. There are no
user serviceable parts inside. Please refer all servicing to licensed service technicians.
CAUTION! The international symbol of a lightning bolt inside a triangle is intended to alert the user to
uninsulated “dangerous voltage” within the device’s enclosure. The international symbol of an
exclamation point inside a triangle is intended to alert the user to the presence of important
operating, maintenance and servicing information in the manual accompanying the device.
CAUTION! To prevent electrical shock, match wide blade of plug to wide slot, fully insert.
CAUTION! To reduce the risk of electrical shock, do not expose this equipment to rain or moisture.
1. Read Instructions—All safety and operating instructions should be read before operating the device.
2. Retain Instructions—The safety and operatinginstructions should be retained for future reference.
3. Heed Warnings—All warnings on the device and in the operating instructions should be adhered to.
4. Follow Instructions—All operating and safety instructions should be followed.
5. Water & Moisture—The device should never be used in, onor near water for risk of fatal shock.
6. Ventilation—The device should always be located in such a way that it maintains proper ventilation. It should
never be placed in a built-in installation or anywhere that may impedethe flow of air through its ventilation
slots.
7. Heat—Never locate the device near heat sources such as radiators, floor registers, stoves or other heat-
generating devices.
8. Power Cord Protection—Power cables should be routed so they are not likely to be stepped on or crushed by
items placed on them or against them. Special attention should be paid to areas where the plug enters a socket
or fused strip and where the cord exits the device.
9. Periods Of Non-Use—The device should be unpluggedwhen not being used for extended periods.
10. Dangerous Entry—Care should be taken that no foreign objects or liquids fall or are spilled inside the
device.
11. Service—The device should always be serviced by licensed technicians. Only replacement parts
specified by the manufacturer should be used. The use of unauthorized substitutions may result in fire,
shock, or other hazards.
12. Damage Requiring Service—The device should be servicedby licensed technicians when:
•The plug or power supply cord has been damaged.
•Objects have fallen or liquid has spilled inside the device.
•The device has been exposed to moisture.
•The device does not appear to be operating properly or exhibits a marked change in performance.
•The device has been dropped or the enclosure becomes damaged.

2 | Page
13. Do not position the equipment so that it is difficult tooperate the disconnecting device (power cord).
14. If the equipment is used in a manner not specified by the manufacturer, the protection provided by
the equipment may be impaired.
15. The power switch should be in the “off” position when connecting or disconnecting equipment from
a Torus Power unit.
16. CAUTION Some units can be very heavy, please use safe practices when lifting.

3 | Page
Shipping Carton & Packing Material
Please keep the original shipping box and all packing material. This will ensure the unit is protected in future
transport.
In the unlikely event you have a problem and must return it for service you must use the original packing
material.
Ship the unit only in the original packing material, as the unit is not insurable by carriers otherwise.
Placement & Ventilation
Torus Power PIUs (Power Isolation Units) are extremely efficient yet very high power devices, and must be
adequately cooled.
PIUs have ventilation slots on the base, side panels and on the cover. Maintain at least 1” distance
from each of these surfaces to anything else. Should your installation conditions be confined,
additional forced air-cooling may be necessary.
Do not install the unit directly above heat generating equipment. Maintain at least 6” behind the PIU for
adequate wiring space.
Warranty
Torus Power Inc. products are warranted to be free from manufacturing defects as follows;
•Five years from the original date of sale for toroidal transformers
•Two years from the original date of sale for all other components
The product warranty includes parts, labour and return shipping to the customer. Shipping to Torus
Power Inc. for warranty repair is the responsibility of the customer.
Warranty coverage is not transferrable and original proof of purchase is required for warranty claims. In the
event of a warranty claim, Torus Power Inc. will remedy the issue by repair or replacement, as we deem
necessary, to restore the product to full performance.
This warranty is considered void if the failure of the product or any component part is caused by damage or
misuse. Failure to fully comply with Torus Power Inc. operating instructions voids the warranty.

4 | Page
Torus Power AVR ELITE SERIES Overview
Torus Power AVR ELITE models deliver clean AC power with noise attenuation from 2 KHz to beyond 1 MHz. They
provide true isolation (using large toroidal transformers) along with low source impedance and high
instantaneous current for today’s most sophisticated and powerful audio amplifiers. The performance level is far
beyond what any typical power conditioner using discrete filters can provide.
Torus Power AVR ELITE series products are full-feature state-of-the art power transformers and voltage
stabilizers, with a built-in web browser interface for Local Area Network and Cloud based connectivity for
monitoring and control of audio/video systems. It is not necessary to use either as the AVR ELITE provides all the
standard features, performance, and benefits right out of the box.
The AVR ELITE series provides multiple outlet zones that can be separately turned on or off through the web
browser or via user defined schedules. A key feature is the voltage stabilization that keeps an optimal output
voltage range (North America models +/- 4V, Europe/Asia/Australia +/- 8V of nominal operating voltage)
regardless of fluctuations in the line voltage. Voltage sags, brownouts, and surges can stress components and
shorten equipment life with worst case catastrophic events destroying valuable equipment. In such real world
conditions, the Torus Power AVR ELITE can protect your equipment and improve the quality of your audio and
video experience.
Series mode surge suppression is built into each AVR ELITE to provide protection against lightning strikes and
other power disturbances, meeting IEEE endurance standards of 6000 volts, 3000 amps, with 1000 repeats.
Summary of AVR ELITE Series Features
• Toroidal isolation provides ultimate clean power performance
• Remote power management using Torus Power Connect cloud-based service
• Automatic voltage regulation with 4V increments maintains stable voltage output
• Series mode surge suppression protects against lighting, surges, spikes etc.
• Connect to local network using Web page browser
• Addressable outlet zones for control and monitoring
• Scheduling and sequencing of outlet zones
• Password control
• Email notification of fault conditions
• No programming or internet connection needed (required if using Torus Power Connect service)
• Powerful 32-bit processor
• Large graphical display of key power parameters
• Internal Flash Memory for 10,000 events to record data when cloud unavailable
• Internal high reliability power supply module
• Enhanced communication module including WiFi connectivity
• USB 2.0 port for 3rd party connectivity, LED lighting, and charging
• Optical isolation between high voltage and low voltage to increase safety and compliance to new standards

5 | Page
Front Panel Display
The front panel consists of a 4 line LCD display and a pushbutton switch. Each time you push the button
the display will show a different feature of the AVR ELITE.
When you first turn on the AVR ELITE the System Status will appear. Each time you push the button it
will change from one information screen to another.
Time/Day/Date System Status
Power Status IP and MAC Address
IMPORTANT NOTE:
The following screen is shown but does not apply to the AVR ELITE models which do not have individual
outlet zones. It will indicate all zones as ON or OFF. Individual zone control is available on AVR-2 ELITE
models only.

6 | Page
Voltage Fault Protection
If the AC voltage supplied to the AVR ELITE is too high or too low voltage (see reference chart at the end
of this section) for 1 second or more, a voltage fault message is displayed and the back panel fault
output is turned on. The unit automatically goes into shut down mode so the voltage to each power
outlet on the back panel is automatically turned off even while the front panel power switch remains in
the ON position.
The front panel display will alternate to show either of the following message pairs:
OR
When the AC supply voltage has returned to a normal operating range for 1 minute consecutively the AVR
ELITE will resume normal operation and the High or Low AC Voltage advisory message will no longer appear
on the LCD display. The rear panel outlets will provide power again.
Nominal
Input
Output
Fully
Regulated
Output
Range
Auto
Shutdown
Low Input
Voltage
Auto
Shutdown
High
Input
Voltage
Output
Range
Before
Auto
Shutdown
Fully
Regulated
Input
Range
Auto
Turn
On
Low
Input
Value
Auto
Turn
On
High
Input
Value
North American
120
120
+/- 4V
116-124
<85
>135
110-130
90-130
90
130
Notes:
1. The AVR ELITE unit with SMSS option need to be switched ON at all times for series mode surge
protection (SMSS) tobe active. If the AVR ELITE and connected components will not be used for
an extended period of time, it is recommended to unplug the AVR ELITE unit from main power.
2. There is a 20-second delay built into the AVR ELITE system, to prevent nuisance switching. The AVR
ELITE will take approximately 20-seconds to change relay taps to switch to the properoutput
voltage setting.
3. North American models (10A): Torus AVR ELITE will keep the output constant within the range of
120±4V, with an input voltage of 90V to 130V. Between 85V to 90V,and between 130V and 135V, the
regulation will be reduced.

7 | Page
4. The output current (Amps) displayed on the LCD is the RMS reading of the load. It doesnot
indicate the peak current loads.
5. A drop in the input voltage is normal when increasing the load on the AVR ELITE. This is a result of
the impedance of the power line, a function of the distance from the electrical panel and
transformer regulation.

8 | Page
Component Connections
The number of outlet connections for audio and video equipment is dependent on the model of AVR ELITE
(see charts on pages 16 and 17).
TOT AVR ELITE 10 / TOT AVR ELITE 10 SMSS / AVR ELITE 15 / AVR ELITE 20
TOT AVR ELITE 4 CE / TOT AVR ELITE 4 CE SMSS
The full output current of the AVR ELITE is available from any outlet. If, for example, the equipment connected
to an outlet draws 5 amps then in the case of an AVR ELITE 20 there is 15 amps still available for equipment
connected to any of the other outlets.

9 | Page
Rear Panel Connections
Ethernet
Allows access to the AVR ELITE and internal software via a local web browser interface (See AVR ELITE software
section for more details) or Torus Power Connect service (see Torus Power Connect section).
USB 2.0 Port
For charging and external control (future)
12VDC Trigger On/Off
The AVR ELITE can be turned on and off by a 12 volt trigger input. Applying 12 volts turns ON the AVR
ELITE and removing the 12 volts turns it OFF. Requires a 3.5 mm TS type male audio connector with tip
wired as positive and sleeve wired as negative from controlling source.
12VDC Fault Output
The AVR ELITE provides a 12 volt fault output through a jack on the back panel. The output goes to 12
volts when a relay or voltage fault is detected. The maximum current that can be drawn from this
output is 75mA. Requires a 3.5 mm TS type male audio connector with tip wired as +ve and sleeve wired
as -ve.
Antenna
Connect the provided antenna for WiFi functionality if using the Torus Power Connect service.

10 | Page
Specifications
North American Models
Electrical Specifications
Model Number
Input Voltage
Nominal
Output Voltage
Nominal
Input Fuses Maximum Available
Output Current
Number of Outlets
AVR ELITE 15
120VAC, 60Hz
(Operating Range
85V to 135V)
120VAC ± 4V
1
1 x 15A
15A
10
AVR ELITE 20
1 x 20A 20A 10
TOT AVR ELITE 10
1 x 10A
10A
10
TOT AVR ELITE 10
SMSS
1 x 10A 10A 10
Mechanical Specifications
Model Number Input Connector
(Rear Panel)
Output Connector
(Rear Panel)
Line Cord
Size, mm (WxDxH)
Size, inch (WxDxH)
Weight
Kg (lbs)
Chassis
Height
AVR ELITE 15
IEC 20A Inlet,
NEMA C20
10 Medical Grade
Outlets, 15A
N5/15, 14AWG-C13,
15A/125V
483x483x203
17x19x8
40.5(89)
2U (4”)
AVR ELITE 20 IEC 20A Inlet,
NEMA C20
10 Medical Grade
Outlets, 20A
N5/20, 12AWG-C19,
20A/125V 483x559x249
17x22x9.8
63(139) 4U (8”)
TOT AVR ELITE 10
IEC 15A Inlet,
NEMA C14
10 Medical Grade
Outlets, 15A
N5/15, 14AWG-C13,
15A/125V 31.8 x 36.8 x 10.2
12.5 x 14.5 x 4
16 (35.3) 2U (4”)
TOT AVR ELITE 10
SMSS
IEC 15A Inlet,
NEMA C14
10 Medical Grade
Outlets, 15A
N5/15, 14AWG-C13,
15A/125V
16.4(36.2) 2U (4”)
Surge Suppression
Series Mode Surge Suppression (SMSS)
SMSS non sacrificial surge suppression can added to provide protection on the output side of the transformer.
Electrical specifications remain the same for each model with or without the TVSS surge suppression option.

11 | Page
International Models
Electrical Specifications
Model Number
Input Voltage
Nominal
Output Voltage
Nominal
Input Circuit
Breaker (Fuses)
Maximum Available
Output Current
Number of Outlets
TOT AVR ELITE
4 CE
230VAC, 50Hz
(Operating Range
170V to 270V)
230VAC ± 8V 1 x 4A
4A
4
TOT AVR ELITE
4 CE SMSS
Mechanical Specifications
Model Number
Input Connector
(Rear Panel)
Output Connector
(Rear Panel)
Line Cord Size, cm (WxDxH)
Size, inch (WxDxH)
Weight
Kg (lbs)
Chassis
Height
TOT AVR ELITE
4 CE
IEC 15A Inlet,
NEMA C14
SCHUKO CEE 7/7
10A/250VAC, 2.5M
Plug: CEE 7/7
Connector: IEC -
C13
43.2 x 48.3 x 10.2
17 x 19 x 4
24.5 (54)
2U (4”)
TOT AVR ELITE
4 CE SMSS 25 (55)
Surge Suppression
Series Mode Surge Suppression (SMSS)
SMSS non sacrificial surge suppression can added to provide protection on the output side of the transformer.
Electrical specifications remain the same for each model with or without the TVSS surge suppression option.

12 | Page
Circuit Schematics
North American TOT AVR ELITE 10 Model

13 | Page
TOT AVR ELITE 4 CE Model

14 | Page
Factory Reset Procedure
1. Disconnect the Ethernet cable from the AVR.
2. Turn the power switch to the OFF position. The power light will go out.
3. Press and hold the little pushbutton switch below the front panel display on the AVR.
4. Continue to hold the pushbutton switch and turn the power switch to the ON position. Hold the
pushbutton switch for approximately 30 seconds and then release the pushbutton switch.
5. Use the pushbutton as you would normally to scroll through the various screens until you get to the IP
address screen and it should now show as 0.0.0.0.
6. Plug in the Ethernet cable. The IP address should change to a value appropriate for your new network
setup as the unit’s network configuration is now set to factory default as DHCP.
7. You can then use this new IP address to access the unit as you did previously if you wish to assign it a new
static IP address.

15 | Page
AVR ELITE Embedded Software
The AVR ELITE local area network web browser interface is resident in the microprocessor on the internal
control board. There are two methods to access the software.
1) Connect the AVR ELITE Ethernet port to a local network port and open a web browser on a PC that
is connected to the same local network. Enter AVR (or the IP address displayed on the AVR ELITE’s LCD
display) into the browser window. Press ENTER and the software will open.
2) Use a three way DHCP Router. You then connect both PC and AVR ELITE to the same DHCP Router.
Open a browser window from the PC. Type AVR, (or the IP address displayed on the LCD) into the
browser window. Press ENTER and the software will open.
Username and Password
The password is required to change the setup of the Torus unit.
Username: admin
The username is factory set and cannot be changed.
Password: avr
This is the default password, and can be changed.
You can change your password by selecting: Set Password
Forget your password
The AVR ELITE can be restored to the factory default password
avr by pressing and holding the button on the front panel for at
least 10 seconds.

16 | Page
AVR ELITE Menu Selections
System Status
This screen indicates the overall status of the
system, showing Voltage In, Voltage Out,
Current Out, and Power Consumption.
It also reports if the system is functioning
normally or whether there is a fault condition.
(No password required to monitor status)
IMPORTANT NOTE:
This AVR ELITE model does not have individual
outlet zones. It will indicate all zones as ON or OFF.
Switch Main Power
This screen allows ON/OFF control of the AVR
ELITE unit.
Press the SET button to implement your
selection. As the output power from the Torus
AVR ELITE unit is shut down, all the connected
equipment is turned off.
The AVR ELITE main power switch remains in
the ON position, although there is no power to
the load.

17 | Page
Zone Power Control
IMPORTANT NOTE:
Individual outlet
zone power control is not available
on this AVR ELITE model.
Email Fault Alert Notification
In the unlikely event your AVR ELITE
experiences an issue the AVR ELITE will shut
down and send an email notification, if this
section is configured.
After entering the configuration parameters use
the ‘Send Test Email’ button to confirm your
settings are correct.
Date and Time Setup
When the AVR ELITE is connected to the
Internet, the date, time and day will
automatically be set. However, when the AVR
ELITE has no access to the Internet the Date,
Time and Day can be set manually which will
allow the AVR ELITE to follow scheduled
programming even if the Internet is later
unavailable.
If the Internet connection is restored the date,
time and day will be automatically set.
WARNING: If the unit is powered off/on when
the Internet connection is lost the date, time
and day is nulled. It can be manually re-
entered here.
This manual suits for next models
6
Table of contents
Other Torus Power Transformer manuals
Popular Transformer manuals by other brands

Maddox
Maddox MIT100-15A Installation, operation & maintenance manual

LiteOn
LiteOn Chameleon 100 Installation and operation manual

Sealey
Sealey TR1000.V3 instructions

Hubbell
Hubbell Dual-Lite Trident TRF 924 user manual

marklin
marklin 81705 user manual

Titanium
Titanium TT-DR-CVB-080 electrical connections