Toshiba America Information Systems Inc. ("TAIS") shall not be liable for damages of any kind for use of this information, which is subject to
change without notice. Copyright 1994 TAIS. 3200.doc Rev. 2 04/04/00 MQC/nmm.
Page 2
IBM Compatible Expansion Slots
One full length IBM PC/XT/286 16-bit slot low profile ISA slot; One IBM PC/XT half length low profile 8-bit ISA slot
Combined power for both slots: + 5 V 2A
+12 V 0.6A
- 5 V and -12 V total of 0.2A
Maximum card sizes: 16-bit long slot 333.502mmL +/- .5mm x 106.68mmW
99.06mmW +/- .3mm w/o connector
33mmH or 13mmH if short slot used
8-bit short slot 140mmL x 13mmH, width same as 16 bit
Soft Switches
1) Change CPU speed
Fn + Ctrl + PgUp 12MHz CPU speed
Fn + Ctrl + PgDn 6MHz CPU speed
2) Character font
Fn + Right arrow Toggles display font
3) Display select
Fn + End External display
Fn + Home Plasma display
4) Extending the display area
Fn + Down arrow Toggles between 350 and 400 rows
Hardware Switches and Controls
1) Power on/off
Located on back of computer
2) A/B/PRT switch
Located on back of computer
With switch set to "A", external FDD port is accessed as drive A; internal 3.5" FDD as drive B.
With switch set to "B", external FDD port is accessed as drive B; internal 3.5" FDD as drive A.
Switch is set to "PRT" for parallel printer output.
Computer must be re-booted for switch change to take effect.
3) Plasma display brightness and contrast dials
Located on right side of display/computer
4) 6 DIP switch bank
Located on back of computer
Power off computer before changing switch settings
Factory default settings all off
SW1 OFF IBM EGA compatible ON Auto-Switched display mode
SW2 OFF PRT output only ON PRT bidirectional
SW3 OFF Serial port COM 1 ON Serial Port COM 2
SW4 OFF Single dot font ON Double dot font
SW5 OFF Enable Internal video controller ON Disable internal video controller
SW6 OFF American Font ON North European font
SW7 SW8 SW9 SW10 Tables for Monitor
OFF OFF ON OFF Monochrome (720 x 350)
ON OFF OFF ON Standard RGB ( 40 col. )(320 x 200)
OFF OFF OFF ON Standard RGB ( 80 col. )(640 x 200)
ON ON ON OFF Enhanced RGB (640 x 200)
OFF ON ON OFF Enhanced RGB (640 x 350 EGA)
OFF OFF OFF OFF Toshiba high resoultion mode (640 x 400)
5) 110V or 220V
Move metal plate for appropriate voltage. Default in USA will show 115V with 230V label covered by metal plate.