TRADEDOR RD3X2 User manual

Tradedor Installation Guide RD3X2(B) Control Box, 2022/1
RD3X2(B) CONTROL BOX
Installation Guide for Roller Shutters
with no vehicle/pedestrian access
Edition 2022/1

Tradedor Installation Guide RD3X2(B) Control Box, 2022/1
1 Remove the lid of the receiver box by
unscrewing small screw at bottom (g.1A)
and then sliding the lid up, being careful to
remove plug-in cable from board (g.1C).
2 Place the Receiver box on the wall with the
cable pointing downwards at a comfortable
height to operate the push buttons, but out of
the easy reach of children. Between 1500mm
up from the oor and 300mm down from the
roof/ceiling is recommended.
3 Making sure the box is square, mark the two
xings (one top and one bottom), then drill
and secure with xings (g.1B).
4 If you have a safety break with a cable then
run the two core cable from the safety brake
end across to the same end as the receiver
box, making sure to securely x the cable out
of the way of the working mechanism.
5 For ease of installation, undo the terminal
clamp at the bottom (g.1D).
6 Wiring as follows (g.2 & g.3);
Pre wired Mains Power:
N – Neutral / Blue power cable
L – Live / Brown power cable
Earth – Earth power cable
Motor:
L - Brown motor cable (4 core)
R - Blue motor cable (4 core)
Earth - Earth connection motor cable (4 core)
N - Blue motor cable (4 core)
Safety Brake:
Remove red link wire from G and S, wire 2
core cable as follows;
G - Blue safety brake cable (2 core)
S - Brown safety brake cable (2 core)
Special Attention: Red link wire from G to U
MUST stay in.
Pictures are for illustration purposes only, connector blocks are not provided and further ttings may be required.
1
1. Installing Receiver Box
fig.2
fig.2 (no safety brake)
fig.1
B
B
D
C
A
fig.3
230v TUBE MOTOR
CONNECTION
Connect tube motor
where shown
Note: This connection will supply
230v AC and is specifically for
tube motor operation
Tube Motor 230v AC 50Hz
Mains Supply
230v AC 50Hz
Stop
Gn/Yl
Brown
Blue
Mains Supply Connection
AC IN
N L
Connect mains
power supply
where shown
Recommended
Power Supply
Protection:-
13A fused Spur or
Single Pole
connected
protected by MCB
Type 'A'
Ext Key-Switch Connection
Close
Open
Com
Ext Push Button Connection
Open
Close
L
R
N
Motor Direction
Motor Earth
Motor Common
Motor Direction
Terminal Connections
U D G VU S
MANUAL PHOTOCELL
24v dc
Reflective
Photocell
0v
U D G V U S
MANUAL PHOTOCELL
24v DC Photocell Connection
+24v
N/C
com
UD G VUS
MANUA PHOTOCELL
N
LMains Power 230v AC (Live)
Mains Power 230v AC (Neutral)
Mains Power (Earth)
UExternal connection - Open
D External connection - Close
V +24v dc
G 0V / Switch Common / Photocell Common
Photocell connection - N/C contact
External connection - Stop
Mains Supply
Motor
Manual
Photocell
Basic Remote Control Operation
UDGVUS
MANUAL PHOTOCELL
External
Push Button
Connection
Safety Brake Connection
U D GVU S
MANUAL PHOTOCELL
Safety Brake
(N/C) Switch
Connection
MOTOR
L R N
230v Tube Motor Connection
Gn/Yl
Black
Brown
Blue
Connect tube
motor where
shown
Note:
This connection
will supply 230v
AC and is
specifically
for tube motor
operation
Tube Motor
230v AC 50Hz
MOTOR
L R
Volt free Switching Connection
N
Connection to
provide a 'volt
free' switching
operation
Com
Close
Open
To add an additional external
push button station
Connect where shown leaving link
fitted between G + U
To add an additional external
key-switch
Connect where shown leaving link
fitted between G + U + S
To add an additional photocell for
safety
Connect where shown leaving
links fitted between G + S
Activating the photocell will stop
and re-open a closing door
External
Key switch
Connection
Date
Drawn by
Chk'd by
Drg #
Title
Ellard House
Floats Road
Roundthorn Industrial Estate
Wythenshawe, Manchester
M23 9WB
Tel: 0161 945 4561
Fax: 0161 945 4566
This drawing is the property of ELLARD LTD, it may not be reproduced without the written authorisation of Ellard Ltimited. All interlecual property rights are expressly reserved Revision / Notes:
04/07/2018
D. England
J. Monks
This is a special connection that
does not provide a voltage output
The unit must be factory modified
to give this function and will be
marked 'Volt Free' as such
For Basic remote Control
Operation
Leave links fitted between
G + U + S
Connect safety brake where
shown
Leave link fitted between
U + S
Connection Detail For
ATHENA 2nd GEN
(White Enclosure/White Transmitter)
elec-ATHENA2-001A
Com
MAINS SUPPLY
CONNECTION
Connect mains power supply
where shown
Recommended Power Supply
Protection:- 13A fused Spur or
Single Pole connected protected
by MCB Type 'A'
Mains Supply 230v AC 50Hz
Mains Supply
230v AC 50Hz
Stop
Gn/Yl
Brown
Blue
Mains Supply Connection
AC IN
N L
Connect mains
power supply
where shown
Recommended
Power Supply
Protection:-
13A fused Spur or
Single Pole
connected
protected by MCB
Type 'A'
Ext Key-Switch Connection
Close
Open
Com
Ext Push Button Connection
Open
Close
L
R
N
Motor Direction
Motor Earth
Motor Common
Motor Direction
Terminal Connections
U D G VU S
MANUAL PHOTOCELL
24v dc
Reflective
Photocell
0v
U D G V U S
MANUAL PHOTOCELL
24v DC Photocell Connection
+24v
N/C
com
UD G VUS
MANUA PHOTOCELL
N
LMains Power 230v AC (Live)
Mains Power 230v AC (Neutral)
Mains Power (Earth)
UExternal connection - Open
D External connection - Close
V +24v dc
G 0V / Switch Common / Photocell Common
Photocell connection - N/C contact
External connection - Stop
Mains Supply
Motor
Manual
Photocell
Basic Remote Control Operation
UDGVUS
MANUAL PHOTOCELL
External
Push Button
Connection
Safety Brake Connection
U D GVU S
MANUAL PHOTOCELL
Safety Brake
(N/C) Switch
Connection
MOTOR
L R N
230v Tube Motor Connection
Gn/Yl
Black
Brown
Blue
Connect tube
motor where
shown
Note:
This connection
will supply 230v
AC and is
specifically
for tube motor
operation
Tube Motor
230v AC 50Hz
MOTOR
L R
Volt free Switching Connection
N
Connection to
provide a 'volt
free' switching
operation
Com
Close
Open
To add an additional external
push button station
Connect where shown leaving link
fitted between G + U
To add an additional external
key-switch
Connect where shown leaving link
fitted between G + U + S
To add an additional photocell for
safety
Connect where shown leaving
links fitted between G + S
Activating the photocell will stop
and re-open a closing door
External
Key switch
Connection
Date
Drawn by
Chk'd by
Drg #
Title
Ellard House
Floats Road
Roundthorn Industrial Estate
Wythenshawe, Manchester
M23 9WB
Tel: 0161 945 4561
Fax: 0161 945 4566
This drawing is the property of ELLARD LTD, it may not be reproduced without the written authorisation of Ellard Ltimited. All interlecual property rights are expressly reserved Revision / Notes:
04/07/2018
D. England
J. Monks
This is a special connection that
does not provide a voltage output
The unit must be factory modified
to give this function and will be
marked 'Volt Free' as such
For Basic remote Control
Operation
Leave links fitted between
G + U + S
Connect safety brake where
shown
Leave link fitted between
U + S
Connection Detail For
ATHENA 2nd GEN
(White Enclosure/White Transmitter)
elec-ATHENA2-001A
Com
SAFETY BREAK
CONNECTION
Connect safety brake
where shown
Safety Break (N/C) Switch
Connection
Mains Supply
230v AC 50Hz
Stop
Gn/Yl
Brown
Blue
Mains Supply Connection
AC IN
N L
Connect mains
power supply
where shown
Recommended
Power Supply
Protection:-
13A fused Spur or
Single Pole
connected
protected by MCB
Type 'A'
Ext Key-Switch Connection
Close
Open
Com
Ext Push Button Connection
Open
Close
L
R
N
Motor Direction
Motor Earth
Motor Common
Motor Direction
Terminal Connections
U D G VU S
MANUAL PHOTOCELL
24v dc
Reflective
Photocell
0v
U D G V U S
MANUAL PHOTOCELL
24v DC Photocell Connection
+24v
N/C
com
UD G VUS
MANUA PHOTOCELL
N
LMains Power 230v AC (Live)
Mains Power 230v AC (Neutral)
Mains Power (Earth)
UExternal connection - Open
D External connection - Close
V +24v dc
G 0V / Switch Common / Photocell Common
Photocell connection - N/C contact
External connection - Stop
Mains Supply
Motor
Manual
Photocell
Basic Remote Control Operation
UDGVUS
MANUAL PHOTOCELL
External
Push Button
Connection
Safety Brake Connection
U D GVU S
MANUAL PHOTOCELL
Safety Brake
(N/C) Switch
Connection
MOTOR
L R N
230v Tube Motor Connection
Gn/Yl
Black
Brown
Blue
Connect tube
motor where
shown
Note:
This connection
will supply 230v
AC and is
specifically
for tube motor
operation
Tube Motor
230v AC 50Hz
MOTOR
L R
Volt free Switching Connection
N
Connection to
provide a 'volt
free' switching
operation
Com
Close
Open
To add an additional external
push button station
Connect where shown leaving link
fitted between G + U
To add an additional external
key-switch
Connect where shown leaving link
fitted between G + U + S
To add an additional photocell for
safety
Connect where shown leaving
links fitted between G + S
Activating the photocell will stop
and re-open a closing door
External
Key switch
Connection
Date
Drawn by
Chk'd by
Drg #
Title
Ellard House
Floats Road
Roundthorn Industrial Estate
Wythenshawe, Manchester
M23 9WB
Tel: 0161 945 4561
Fax: 0161 945 4566
This drawing is the property of ELLARD LTD, it may not be reproduced without the written authorisation of Ellard Ltimited. All interlecual property rights are expressly reserved Revision / Notes:
04/07/2018
D. England
J. Monks
This is a special connection that
does not provide a voltage output
The unit must be factory modified
to give this function and will be
marked 'Volt Free' as such
For Basic remote Control
Operation
Leave links fitted between
G + U + S
Connect safety brake where
shown
Leave link fitted between
U + S
Connection Detail For
ATHENA 2nd GEN
(White Enclosure/White Transmitter)
elec-ATHENA2-001A
Com

Tradedor Installation Guide RD3X2(B) Control Box, 2022/1
Direction Of Rotation
1 Press and hold the top right button ( ) on the handset and the barrel should start turning in the
downwards direction. Should the barrel be turning in the up direction, press the bottom right stop button
( ) so the barrel stops and then move the right of the two dip switches up (g.5A).
2 Press and hold the top right button ( ) on the handset, and the barrel should start turning in the
downwards direction.
3 Press and hold the bottom button ( ) on the side of the receiver box and the barrel should start turning
in the downwards direction. Should the barrel be turning in the up direction, press the middle button ( )
on the side of the receiver box so the barrel stops and then move the single dip switch up (g.5C).
4 Press and release the down button ( ), if the barrel continues in closing direction, press the middle button
( ) and ick the left of the 2 dip switches up (g.5B), You should now have to press and hold the down
button ( ) to rotate the barrel in the close direction.
1 Slide the cover down on the remote control handset
and you will see there are four buttons (g.4).
2 Press and hold the top left button ( ), then press and hold the top
right button ( ), if the barrel moves then the handset is already
programmed in. Repeat with all other handsets and, if all are
programmed, proceed to ‘Direction of Rotation Section’, if not then
carry on with step 3.
3 With the handset in your hand, press and release the black
programming button located at the top middle of the receiver box
just below the xing screw (g.5). The green LED will start to
ash.
4 Press and release the bottom left programming button on the
handset ( ). The green LED will ash faster and go out.
5 Press and hold the top left button ( ), then press and hold the top
right button ( ) to test. The barrel should move. Repeat with all
other handsets that need programming.
Pictures are for illustration purposes only, connector blocks are not provided and further ttings may be required.
2
2. Programming Remote
Control Handsets
AB C
g.4
g.5
A B C
Deleting Remote Control Handset’s Memory
1 Press and hold the black programming button for roughly 3 seconds. The green LED will ash three
times, go solid, then rapidly ash. Keep hold until ashing stops.
2 Test to see if remote operates barrel.

Tradedor Installation Guide RD3X2(B) Control Box, 2022/1
Pictures are for illustration purposes only, connector blocks are not provided and further fittings may be required.
3. Optional Extras
3
Hard Wired Rocker / Key Switch
Wiring As Follows:
Key Switch (g.8):
Right Block 13 – Up wire
Left Block 14 – Down wire
Right Block 14 – Common wire for the supply to the
switch
Left Block 13 – Right Block 14 Link wire between
terminals
To open key switch remove screw then turn key
a quarter turn.
Rocker Switch (g.7):
4 – Up wire
3 – Down wire
5 – Common wire for the supply to the switch
Fit Link wire from 5 to 2
To open rocker switch remove screws.
Receiver Box Green 6 Block Terminal (g.6):
U – Up wire from switch
D – Down wire from switch
G – Common wire for the supply to the switch
g.6
g.8a
g.8b
g.7
Link wire
Up wire
Down wire
Common wire

Tradedor Installation Guide RD3X2(B) Control Box, 2022/1
© Tradedor 2022 All Rights Reserved. Tradedor is a trading name of
Rollerdor Ltd. Registration Number: 10676267, VAT Number: 990994847.
Tradedor
16 Jarrold Way
Bowthorpe Employment Area
Norwich
Norfolk NR5 9JD
+44 (0)1603 743215
sales@tradedor.co.uk
www.tradedor.co.uk
Edition 2022/1
This manual suits for next models
1
Table of contents