Transcension UP2-RF User manual

Order code: BOTE32
UP2-RF
Dimmer Controller
User Manual

www.prolight.co.uk UP2-RF Dimmer Controller User Manual 2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Before your initial start-up, please make sure that there is no damage caused during transportation.
• Should there be any damage, consult your dealer and do not use the equipment.
• To maintain the equipment in good working condition and to ensure safe operation, it is necessary
for the user to follow the safety instructions and warning notes written in this manual.
• Please note that damages caused by user modications to this equipment are not subject to warranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc.
Do not endanger your own safety and the safety of others!
Incorrect installation or use can cause serious damage to people and/or property.
• Never let the power cable come into contact with other
cables. Handle the power cable and all mains voltage
connections with particular caution!
• Never remove warning or informative labels from the unit.
• Do not open the equipment and do not modify the unit.
• Do not connect this equipment to a dimmer pack.
• Do not switch the equipment on and off in short intervals,
as this will reduce the system’s life.
• Only use the equipment indoors.
• Do not expose to ammable sources, liquids or gases.
• Always disconnect the power from the mains when
equipment is not in use or before cleaning! Only handle
the power-cable by the plug. Never pull out the plug by
pulling the power-cable.
• Make sure that the available voltage is 230V AC~50Hz.
• Make sure that the power cable is never crimped or
damaged. Check the equipment and the power cable
periodically.
• If the equipment is dropped or damaged, disconnect the
mains power supply immediately and have a qualied
engineer inspect the equipment before operating again.
• If the equipment has been exposed to drastic
temperature uctuation (e.g. after transportation),
do not connect power or switch it on immediately.
The arising condensation might damage the equipment.
Leave the equipment switched off until it has reached
room temperature.
• If your product fails to function correctly, stop use
immediately. Pack the unit securely (preferably in the
original packing material), and return it to your Pro Light
dealer for service.
• Only use fuses of same type and rating.
• Repairs, servicing and power connection must only be
carried out by a qualied technician. THIS UNIT CONTAINS
NO USER SERVICEABLE PARTS.
• WARRANTY: One year from date of purchase.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!

www.prolight.co.uk UP2-RF Dimmer Controller User Manual 3
Product overview & technical specications
The UP2-RF is a single channel DMX dimmer which can be converted to a single channel switch pack. The unit
features 0 -100% dimming and a 3 push button LED menu system.
• Compact, 1 channel DMX / HTP Dimmer Pack
• Standard DMX 512 Protocol
• Dim Preset - Dim Limiter and can be changed
from a Dimmer to a Switch Pack
• Suitable for use with incandescent loads
when used as a switch pack
• LED Display makes it easy to set DMX
channels
• HTP function
• 3-Pin XLR input/output
• Output: 2 x IEC Socket
• Easy to use mounting bracket
• Maximum Power: 10A
UP2-RF Dimmer Controller
Specications
Power supply 230V, 50Hz
Fuse F10A 250V
Dimensions 182 x 92 x 68mm
Weight 1.1kg
Order code BOTE32
01 - 2 x IEC outputs
02 - LED display
03 - HTP fader
04 - Menu button
05 - Up button
06 - Down button
07 - External HTP fader
08 - Captive power
connection
09 - Fuse F10A 250V
10 - 3-Pin XLR DMX input
11 - 3-Pin XLR DMX output
12 - Phone jack to connect
external HTP fader
In the box:
1 x controller,
1 x External HPT fader
& 1 x user manual
IP20
10 11
09
08
12
04 05 06
01
03
02
07

www.prolight.co.uk UP2-RF Dimmer Controller User Manual 4
Operating instructions
When the unit is powered up the unit will show
the DMX address that the unit was last in before
it was powered down. If the DMX address 123
was selected in the units last use the the unit will
display “A123”.
By using the “UP” or “DOWN” buttons the user
is able to select the required DMX address.
Once the DMX address is selected, it will be
automatically stored into the units memory.
Press the “MENU” button until
the display shows d---.
Press the “UP” or “DOWN”
button so the display shows
S---.
Press the “MENU” button to
enter switch pack mode. Use
the “UP” or “DOWN” buttons
to change between S-on
and S-oF.
Press the “MENU” button to exit switch pack mode. In Switch pack
on mode the output is on and the xture will illuminate
regardless of the DMX signal. In switch pack off mode the output is
turned off and the xture is controlled via the DMX signal. If the DMX
level is less than 40% the xture will blackout, above 40% the xture
will illuminate.
DMX address mode:
Switch pack mode:
--- ---

www.prolight.co.uk UP2-RF Dimmer Controller User Manual 5
Operating instructions
Dimmer pack mode:
Press the “UP” or “DOWN”
button so the display shows
d---.
---
MENU
Press the “MENU” button to
enter Dimmer limit mode.
Use the “UP” or “DOWN”
buttons to change the value
between 10-100.
Use the “UP” or “DOWN”
buttons to change the value
between 00-100. Once the
dimmer preset is selected it
will be automatically stored
into the units memory.
Press the “MENU” button exit
out of any of the above options.
Press the “MENU” button to
enter Dimmer preset mode.
MENU
MENU
Please note: The HTP Fader MUST be at value 0 for the DMX to operate correctly.

www.prolight.co.uk UP2-RF Dimmer Controller User Manual 6
Setting the DMX address:
The DMX mode enables the use of a universal DMX controller. Each xture requires a “start address”
from 1- 512. A xture requiring one or more channels for control begins to read the data on the channel
indicated by the start address. For example, a xture that occupies or uses 7 channels of DMX and was
addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104,
105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in
the chain starts at 107.
DMX 512:
DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent
xtures and controllers. A DMX controller sends DMX data instructions form the controller to the xture.
DMX data is sent as serial data that travels from xture to xture via the DATA “IN” and DATA “OUT”
XLR terminals located on all DMX xtures (most controllers only have a data “out” terminal).
DMX linking:
DMX is a language allowing all makes and models of different manufactures to be linked together
and operate from a single controller, as long as all xtures and the controller are DMX compliant.
To ensure proper DMX data transmission, when using several DMX xtures try to use the shortest
cable path possible. The order in which xtures are connected in a DMX line does not inuence the
DMX addressing. For example; a xture assigned to a DMX address of 1 may be placed anywhere in
a DMX line, at the beginning, at the end, or anywhere in the middle. When a xture is assigned a
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,
no matter where it is located in the DMX chain.
DATA cable (DMX cable) requirements (for DMX operation):
This xture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit.
Your unit requires either a standard 3-pin or 5-pin XLR connector for data input/output, please check
the xtures specications as to which your unit accepts.
Also remember that DMX cable must be daisy chained and cannot be split.
DMX setup
Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight Concepts dealers.
Please quote: CABL10 – 2m CABL11 – 5m CABL12 – 10m3-Pin:
CABL185 – 2m CABL187 – 5m CABL188 – 10m5-Pin:

www.prolight.co.uk UP2-RF Dimmer Controller User Manual 7
Notice:
Be sure to follow the diagrams below when making your own cables.
Do not connect the cables shield conductor to the ground lug or
allow the shield conductor to come in contact with the XLRs
outer casing. Grounding the shield could cause a short circuit
and erratic behaviour.
Line termination:
When longer runs of cable are used,
you may need to use a terminator on
the last unit to avoid erratic behaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90,
5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR xtures
may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a
3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.
5-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup
Termination reduces signal
transmission problems and
interference. It is always
advisable to connect a DMX
terminal, (resistance 120
Ohm 1/4W) between pin 2
(DMX-) and pin 3 (DMX+) of
the last xture.
5-Pin
1
2 4
5
3
3-Pin
1 2
3
Pin Conguration
3-Pin 5-Pin
Pin 1 - Ground
Pin 2 - Negative
Pin 3 - Positive
– Pin 4 - N/C
– Pin 5 - N/C
1
2
3
1
2
3
DMX 512
3-Pin XLR output
DMX 512
3-Pin XLR input
GROUND
DMX +
DMX –
DMX 512
5-Pin XLR output
DMX 512
5-Pin XLR input
1
2
45
3
12
4
5
3
GROUND
N/C
DMX –
N/C DMX +
1 ground
3 hot
2 cold
3-Pin XLR male 3-Pin XLR female
2 cold
3 hot
1 ground
2 cold
1 ground 5 N/C
3 hot 4 N/C
5-Pin XLR male 5-Pin XLR female
4 N/C
5 N/C 1 ground
3 hot 2 cold

www.prolight.co.uk UP2-RF Dimmer Controller User Manual 8
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
This marking shown on the product or its literature, indicates that it should not be disposed of
with other household wastes at the end of its working life. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, please separate this from other
types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their
local government ofce, for details of where and how they can take this item for environmentally
safe recycling.
Business users should contact their supplier and check the terms and conditions of the
purchase contract. This product should not be mixed with other commercial wastes for disposal.
This manual suits for next models
1
Table of contents
Other Transcension Controllers manuals
Popular Controllers manuals by other brands

National Instruments
National Instruments PXIe-8106 installation guide

Beckett
Beckett R7184 Technical bulletin

Festo
Festo Controller CECC manual

Aurora
Aurora AU-A1ZBSCRGBCX quick start guide

Welker
Welker INLOOP ACE Installation, operation and maintenance manual

Mitsubishi Electric
Mitsubishi Electric MELSEC Q Series Programming manual