manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Transition Networks
  6. •
  7. Computer Hardware
  8. •
  9. Transition Networks REDUNDANT E-FL/RED-SIC User manual

Transition Networks REDUNDANT E-FL/RED-SIC User manual

This manual suits for next models

1

Other Transition Networks Computer Hardware manuals

Transition Networks E-BR-SIC User manual

Transition Networks

Transition Networks E-BR-SIC User manual

Transition Networks N-GXE-POE-EPS-KIT User manual

Transition Networks

Transition Networks N-GXE-POE-EPS-KIT User manual

Transition Networks NM2-FXS-2230-SFP-201 User manual

Transition Networks

Transition Networks NM2-FXS-2230-SFP-201 User manual

Transition Networks PS-T-SIC User manual

Transition Networks

Transition Networks PS-T-SIC User manual

Transition Networks PCM16-FX-LC-01 User manual

Transition Networks

Transition Networks PCM16-FX-LC-01 User manual

Popular Computer Hardware manuals by other brands

Toshiba TOSVERT VF-MB1/S15 IPE002Z Function manual

Toshiba

Toshiba TOSVERT VF-MB1/S15 IPE002Z Function manual

Shenzhen MEITRACK MVT380 user guide

Shenzhen

Shenzhen MEITRACK MVT380 user guide

TRENDnet TEW-601PC - SUPER G MIMO WRLS PC CARD user guide

TRENDnet

TRENDnet TEW-601PC - SUPER G MIMO WRLS PC CARD user guide

StarTech.com CF2IDE18 instruction manual

StarTech.com

StarTech.com CF2IDE18 instruction manual

Texas Instruments LMH0318 Programmer's guide

Texas Instruments

Texas Instruments LMH0318 Programmer's guide

Gateway 8510946 user guide

Gateway

Gateway 8510946 user guide

Devon IT TC2D Quick setup guide

Devon IT

Devon IT TC2D Quick setup guide

Krüger & Matz Air Shair2 owner's manual

Krüger & Matz

Krüger & Matz Air Shair2 owner's manual

Crystalio VPS-2300 quick guide

Crystalio

Crystalio VPS-2300 quick guide

MYiR FZ3 user manual

MYiR

MYiR FZ3 user manual

Protech Systems BC-K200 Quick reference guide

Protech Systems

Protech Systems BC-K200 Quick reference guide

Miranda DENSITE series DAP-1781 Guide to installation and operation

Miranda

Miranda DENSITE series DAP-1781 Guide to installation and operation

Sierra Wireless Sierra Wireless AirCard 890 quick start guide

Sierra Wireless

Sierra Wireless Sierra Wireless AirCard 890 quick start guide

Leadtek Killer Xeno Pro Quick installation guide

Leadtek

Leadtek Killer Xeno Pro Quick installation guide

Star Cooperation FlexTiny 3 Series Instructions for use

Star Cooperation

Star Cooperation FlexTiny 3 Series Instructions for use

Hotone Ampero user manual

Hotone

Hotone Ampero user manual

Connect Tech Xtreme/104-Express user manual

Connect Tech

Connect Tech Xtreme/104-Express user manual

Yealink WF50 user guide

Yealink

Yealink WF50 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

About the Redundant 10BaseFL Slide-In Card:
The TRANSITION Networks, P/N E-FL/RED-SIC, is a slide-in card that provides a
reliable backup feature for the fiber optic connection. The fiber optic cable can
extend the transmission distance up to 6,600 feet (2 kilometers).
Figure 1 Crossview of the Fiber Redundant Slide-In Card
Redundant 10BaseFL Slide-In Card
User’s Guide
Model #: E-FL/RED-SIC
Manual #: 7339.B 5/94
Specifications:
Fiber Connection: ST type connectors (SMA type available
upon request)
Fiber Optic Cable Maximum Distance: 6,600 feet (2 kilometers)
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber
Optional 100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber
Dimensions: 5.50” x 3.00” x 1.00”
(13.97cm x 7.62cm x 2.54cm)
Environment: 0–70 degrees C, 5%–90% humidity
non-condensing, 0–10,000 feet altitude
Limited Warranty: Two years
LED's:
Fiber Port: Link - Lit green LED indicates the Slide-In Card is receiving link
pulsed from a 10Base FL (or FOIRL) compliant device.
Enable - Lit green LED indicates current link between fiber
connections. Only the active enable (1 or 2) LED will
appear.
Fault - Lit red LED indicates a break in both fiber links 1 and 2.
SQE Switch:
The SQE (Signal Quality Error) heartbeat selection jumper can be positioned ON to
enable the SQE or positioned OFF to disable the SQE. The SQE jumper is located on top
of the transceiver printed wiring circuit board. The transceiver SQE is set to the OFF
position at the factory. (Refer to Figure 1 on the front page of this guide.)
SQE Enable Position (ON): The transceiver SQE is positioned ON when connected to a
workstation or DTE.
SQE Disable Position (OFF): The transceiver SQE is positioned OFF when connected to a
Hub or Repeater.
Installation Considerations:
Personnel can hot swap, install or remove a Slide-In Card with the hub unit power
The Slide-In cards can only be installed one way, with the components facing up.
Carefully guide the Slide-In Card along the card guides, until the Slide-In Card flat
connector and internal backplane meet. Carefully seat the connector into the
backplane slot. Firmly push the card into the slot until the Slide-In Card face plate
is flat against the back of the hub frame. Tighten the thumbscrews of the installed
Slide-In Card into the threaded holes on the hub unit.
Technical Support:
For more information about this product or other TRANSITION Networks products
your local TRANSITION Networks distributor.
Direct numbers are listed below:
TN Main Phone Numbers: (800) 325-2725 or (612) 941-7600
TN Technical Support Number: (800) 260-1312
TN Fax Number: (612) 941-2322
FCC Regulations:
Note: This equipment has been tested and found to comply with the limits for a C
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to p
reasonable protection against harmful interference when the equipment is operated
commercial environment. This equipment generates, uses, and can radiate radio f
quency energy and, if not used in accordance with the
instruction manual, may cause harmful interference to radio communications. Op
of this
equipment in a residential area is likely to cause harmful interference in which cas
user will be required to correct the interference at his own cost.
Canadian Regulations:
Note: This digital apparatus does not exceed the Class A limits for radio noise for
apparatus set out on the radio interference regulations of the Canadian Departmen
Communications.
Trademark Notice:
Ethernet is a registered trademark of the Xerox Corporation, Inc.
TRANSITION Networks is a trademark of TRANSITION Networks, Inc.
Re
P/N