manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. TransLite
  6. •
  7. Laboratory Equipment
  8. •
  9. TransLite Veinlite R User manual

TransLite Veinlite R User manual

OR
Selecting Colors:
Depress the End Button [B] to cycle
through these modes:
Orange Optimal wavelength for highlighting the
contrast between the venous blood
vessels and surrounding tissue.
Green Assist in finding arteries and veins.
White Exam light.
Off
Cleaning Directions
Cleaning the device will not be necessary if properly
used with the disposable plastic cover.
In the event that the device needs to be cleaned,
use germicidal wipes sparingly.
Do not submerge the unit in liquid.
Protective Cap:
The purpose of the Protective Cap [E] is to protect
the End Button [B], Side Button [C], and LED
Window [A] while the device is not in use.
Keep a disposable plastic cover on device to
ensure a proper fit.
Attaching an optional Lanyard:
Attach lanyard to the Cap [E]
then snap it over the
End Button [B].
The Protective Cap and lanyard should be cleaned
regularly with alcohol or germicidal solution.
Installing/Replacing Batteries:
The Veinlite R is powered by a single
AAA battery.
1Press firmly on the Battery Cover [D]
near the seam and slide it off.
2Remove the used battery.
3Install a new AAA battery,
oriented as indicated by the
markings inside the battery
compartment.
4Slide the Battery Cover into place.
Warranty
The Veinlite R has a one year parts & labor warranty.
Troubleshooting
Before returning the device to TransLite
for repair, please call or e-mail to obtain an
authorization number and shipping details.
No refunds will be given for
devices shipped without
authorization.
LED Failure
If one of the LED fails to turn on please replace the
batteries. If the problem persists contact TransLite
for assistance.
No Light From Any LEDs
Replace the battery, then try turning the unit on
again. If the device still will not turn on, please
contact TransLite for assistance.
Specifications
Number of LEDs: 1 Orange
1 Green
1 White
Weight with battery: 29g
Dimensions: 96.1×19.0×16.5mm
Battery: AAA 1.5V
Explanation of Symbols
Model Number
Serial Number
Manufacturer
EC Representative (EU Only)
Do not dispose of as unsorted municipal waste
M. Devices Group
Health Education Centre
The Church, Portland Street
Southport PR8 1HU
United Kingdom
+44 1704 544 944
Operating Directions
Disposable Covers:
The Veinlite R should always be used with a
single-use disposable plastic cover to protect it from
contamination and to prevent the spread of
infection.
1Place the Veinlite R inside
the disposable plastic cover.
Check the cover to make sure it
is intact and the flap is on the
side away from the LED
Window [A].
2These covers are not sterile.
They should be wiped
with a germicidal wipe
prior to use.
3Discard the single-use
disposable plastic cover after each
subject.
Disposable plastic covers are not included and
must be ordered fromTransLite or any of its
authorized dealers.
Device:
1 Install a new Cover [F].
2 Slide Large Tail Holder [G] or Small Tail
Holder [H] over the LED Window [A] to
allow illumination of tail veins.
3 Place Veinlite R against the
tail with the Tail Holder in
contact with the tail.
4Depress the End Button [B] to
turn on the LED.
5Apply gentle pressure to the Veinlite R to
maintain optimal contact.
6Device will turn off after cycling
through the colors or you can
depress and hold the End Button [B] for one
second to turn device off.
7When you turn on a device with a low battery the
device will shut itself off.
8Device will shut off after approximately 4 minutes.
Brightness Control:
There are 3 brightness levels. Depress the
Side Button [C] to change the brightness. Each
depression of the button will cycle through low,
medium, and high brightness levels. The lowest
brightness level is the default setting.
Caution
Veinlite R is designed for external use only.
To avoid contamination of the device, Veinlite R must
be used with the disposable plastic cover.
To avoid cross contamination, always change the
disposable plastic cover between subjects and wipe
the new cover with a recommended germicidal wipe.
Always turn the LEDs on after the device is in
position. Do not look directly at the LEDs when they
are illuminated or shine the light from them directly
into anyone’s eyes.
Do not immerse the device in liquid.
Do not autoclave the device.
Introduction
The Veinlite R is a hand-held battery powered
transillumination device for visualizing veins and
arteries in the tails of rats and mice.
Applications
To assist in venous and arterial access in rats and
mice tails.

READ INSTRUCTIONS BEFORE USE
TransLite LLC
345 Commerce Green Blvd
Sugar Land TX 77478 USA
+1 281 240 3111
www.veinlite.com
[email protected]
LED Window [A]
End Button [B]
Cap [E]
Cover [F]
Large Tail Holder [G]
Small Tail Holder [H]
Side Button [C]
Battery Cover [D]
Veinlite R
Selecting Colors:
Depress the End Button [B] to cycle
through these modes:
Orange Optimal wavelength for highlighting the
contrast between the venous blood
vessels and surrounding tissue.
Green Assist in finding arteries and veins.
White Exam light.
Off
Cleaning Directions
Cleaning the device will not be necessary if properly
used with the disposable plastic cover.
In the event that the device needs to be cleaned,
use germicidal wipes sparingly.
Do not submerge the unit in liquid.
Protective Cap:
The purpose of the Protective Cap [E] is to protect
the End Button [B], Side Button [C], and LED
Window [A] while the device is not in use.
Keep a disposable plastic cover on device to
ensure a proper fit.
Attaching an optional Lanyard:
Attach lanyard to the Cap [E]
then snap it over the
End Button [B].
The Protective Cap and lanyard should be cleaned
regularly with alcohol or germicidal solution.
Installing/Replacing Batteries:
The Veinlite R is powered by a single
AAA battery.
1Press firmly on the Battery Cover [D]
near the seam and slide it off.
2Remove the used battery.
3Install a new AAA battery,
oriented as indicated by the
markings inside the battery
compartment.
4Slide the Battery Cover into place.
Warranty
The Veinlite R has a one year parts & labor warranty.
Troubleshooting
Before returning the device to TransLite
for repair, please call or e-mail to obtain an
authorization number and shipping details.
No refunds will be given for
devices shipped without
authorization.
LED Failure
If one of the LED fails to turn on please replace the
batteries. If the problem persists contact TransLite
for assistance.
No Light From Any LEDs
Replace the battery, then try turning the unit on
again. If the device still will not turn on, please
contact TransLite for assistance.
Specifications
Number of LEDs: 1 Orange
1 Green
1 White
Weight with battery: 29g
Dimensions: 96.1×19.0×16.5mm
Battery: AAA 1.5V
Explanation of Symbols
Model Number
Serial Number
Manufacturer
EC Representative (EU Only)
Do not dispose of as unsorted municipal waste
M. Devices Group
Health Education Centre
The Church, Portland Street
Southport PR8 1HU
United Kingdom
+44 1704 544 944
Operating Directions
Disposable Covers:
The Veinlite R should always be used with a
single-use disposable plastic cover to protect it from
contamination and to prevent the spread of
infection.
1Place the Veinlite R inside
the disposable plastic cover.
Check the cover to make sure it
is intact and the flap is on the
side away from the LED
Window [A].
2These covers are not sterile.
They should be wiped
with a germicidal wipe
prior to use.
3Discard the single-use
disposable plastic cover after each
subject.
Disposable plastic covers are not included and
must be ordered fromTransLite or any of its
authorized dealers.
Device:
1 Install a new Cover [F].
2 Slide Large Tail Holder [G] or Small Tail
Holder [H] over the LED Window [A] to
allow illumination of tail veins.
3 Place Veinlite R against the
tail with the Tail Holder in
contact with the tail.
4Depress the End Button [B] to
turn on the LED.
5Apply gentle pressure to the Veinlite R to
maintain optimal contact.
6Device will turn off after cycling
through the colors or you can
depress and hold the End Button [B] for one
second to turn device off.
7When you turn on a device with a low battery the
device will shut itself off.
8Device will shut off after approximately 4 minutes.
Brightness Control:
There are 3 brightness levels. Depress the
Side Button [C] to change the brightness. Each
depression of the button will cycle through low,
medium, and high brightness levels. The lowest
brightness level is the default setting.
Caution
Veinlite R is designed for external use only.
To avoid contamination of the device, Veinlite R must
be used with the disposable plastic cover.
To avoid cross contamination, always change the
disposable plastic cover between subjects and wipe
the new cover with a recommended germicidal wipe.
Always turn the LEDs on after the device is in
position. Do not look directly at the LEDs when they
are illuminated or shine the light from them directly
into anyone’s eyes.
Do not immerse the device in liquid.
Do not autoclave the device.
Introduction
The Veinlite R is a hand-held battery powered
transillumination device for visualizing veins and
arteries in the tails of rats and mice.
Applications
To assist in venous and arterial access in rats and
mice tails.

VLNR DFU Rev B 0519
Made in USA
Veinlite R®is a Registered Trademark.
* Patent Pending

Popular Laboratory Equipment manuals by other brands

Grace Medical 990-001 quick start guide

Grace Medical

Grace Medical 990-001 quick start guide

Miele PG8582 CD Installations plan

Miele

Miele PG8582 CD Installations plan

PASCO OS-9102C quick guide

PASCO

PASCO OS-9102C quick guide

Agilent Technologies Labware MiniHub G5584A user guide

Agilent Technologies

Agilent Technologies Labware MiniHub G5584A user guide

Gerhardt Vapodest 30 instruction manual

Gerhardt

Gerhardt Vapodest 30 instruction manual

Tuttnauer TIVA2 TD Instructions for use

Tuttnauer

Tuttnauer TIVA2 TD Instructions for use

Tektronix 1741C user manual

Tektronix

Tektronix 1741C user manual

Dionex P680 Quick installation guide

Dionex

Dionex P680 Quick installation guide

OHAUS STHVAL instruction manual

OHAUS

OHAUS STHVAL instruction manual

MELAG MELAdem 53 user manual

MELAG

MELAG MELAdem 53 user manual

Sartorius cubis MPS Quick reference guide

Sartorius

Sartorius cubis MPS Quick reference guide

Caframo BDC1850 user manual

Caframo

Caframo BDC1850 user manual

Labnet BioPette PLUS quick start guide

Labnet

Labnet BioPette PLUS quick start guide

Thermo Scientific MaxQ SHKE420HP Operating and maintenance manual

Thermo Scientific

Thermo Scientific MaxQ SHKE420HP Operating and maintenance manual

Bruker 300'154 Ascend DNP user manual

Bruker

Bruker 300'154 Ascend DNP user manual

H.E. Anderson Feeder J Plus Installation Guidelines and Operation

H.E. Anderson

H.E. Anderson Feeder J Plus Installation Guidelines and Operation

Syngene G:Box Chemi XRQ Installation quick guide

Syngene

Syngene G:Box Chemi XRQ Installation quick guide

Kodak Dryview 5800 user guide

Kodak

Kodak Dryview 5800 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.