Tri-Tronics Label-Eye LER Manual

Normal Label Opacity Autoset Button
This category includes most paper or melallized film labels adhering to paper or
transparent backing materials.
To implement the one button Autoset routine, utilize the external alignment guides to
position the gap between labels in line with the dot shown in the center of the detection
zone. Then push the Autoset button marked "Normal".
An alternative set up procedure would be to remove a label and the push
the "Normal" Autoset button.
HINT: If the location of the sensor is several labels up-stream from the peeler plate,
removing just one label will result in applying two labels onto one product and one
product receiving no label what so-ever. This is why we recommend setting up the
sensor with the actual "gap" between the labels properly positioned.
On rare occasions, when the light is unable to penetrate the backing materials, both
the red and green led indicators will blink four times. When this indication occurs, the
sensor will be unable to detect the presence of the labels.
Translucent Label Opacity Autoset Button
This category includes translucent labels adhering to transparent backing materials.
This sensor cannot detect transparent labels adhering to transparent backing
materials. The question is how close to transparent can the translucent labels be and
still be detected? There is no definitive answer to that question. To determine if detection
of a translucent label adhering to transparent backing material is to try the following
Autoset procedure. First utilize the external alignment guides to position the gap
between labels in line with the dot shown in the center of the detection zone. Then
push the Autoset button marked "Translucent". The next step is to move the web so that
the translucent label goes in and out of the light beam. If detection is possible, the red
led output indicator should go on when the label passes through the detection zone.
INVERT OUTPUT: The status of the red led and output transistors can be inverted by
pressing both buttons simultaneously. When the output status has been inverted, the
red led and the output transistors will turn off when the label comes into view.
LABEL•EYE AUTOSET
Set-Up Instructions

070-0150 Rev 3
DIMENSIONS
SPECIFICATIONS
Made in U.S.A.
A
LABEL OPACITY
PLACE GAP OR
WEB ON DOT
BLU
BLK
BRN
WHT
10 to
30 VDC
LOAD
150MA MAX
NEG
PNP
LOAD
POS
NPN
T
R
TM
S
L
U
OUTPUT
AUTOSET
R
L
N
www.ttco.com
O
R
M
A
N
T
N
E
C
34
12
1
2
3
4
RED
BROWN* (1)
WHITE
BLACK* (4)
GREEN
BLACK
BLUE* (3)
GRAY* (5)
BLUE
WHITE* (2)
NPN
AUTOSET INPUT
REMOTE
LOAD
(SOURCE)
NEG
PNP
(SINK)
30 VDC
10 TO
LOAD
POS
BROWN* (1)
RED
WHITE* (2)
WHITE
BLACK* (4)
BLACK
GREEN
BLUE* (3)
LOAD
LOAD
(SOURCE)
NEG
PNP
(SINK)
NPN
POS
30 VDC
10 TO
5 (ONLY ON REMOTE
M12 CONNECTOR
PINOUT
M8 CONNECTOR
PINOUT
* SENSORS WITH CONNECTORS
6" [152.40] P IGTAIL
CONNECTOR
(M12 MO DELS)
* SENSORS WITH CONNECTORS
AUTOSET MODELS)
6' (1.83 METERS)
CABLE
3.641"
(92.47 mm)
0.709"
(18.00 mm)
2.116"
(53.76 mm)
0.117"
(2.98 mm)
0.926"
(23.53 mm )
0.709"
(18.00 mm)
1.071"
(27.21 mm )
2X Ø0.167"
(Ø4.25 mm )
0.984"
(25.00 mm)
0.630"
(16.00 mm)
2.520"
(64.00 mm)
0.472"
(12.00 m m)
2X 6-32 X 1/4" DEEP
MOUNTING HOLES
P.O. BOX 25135, TAMPA, FL 33622-5135
813-886-4000 / 800-237-0946
Nano Cable (M8) Selection Guide
P/N Length Thread Coupling
GEC-6 6 ft. (1.8m Straight Female
GEC-15 15 ft. (4.6m) Straight Female
RGEC-6 6 ft. (1.8m) 90° Female
RGEC-15 15 ft. (4.6m) 90° Female
RoHS Compliant
Product subject to change without notice.
SUPPLY VOLTAGE
• 10 to 30 VDC
• Polarity Protected
• Intended for use in class two circuits
CURRENT REQUIREMENTS
• 45 milliamps (exclusive of load)
OUTPUT TRANSISTORS
• (1) NPN and (1) PNP output transistors
• Sensor outputs can sink or source up to 150 milliamps (current
limit)
• All outputs are continuously short circuit protected
REMOTE AUTOSET INPUT
• opto isolated momentary sinking input (10 milliamps)
Note: Remote models only
RESPONSE TIME
• Light state response = 100 microseconds
• Dark state response = 100 microseconds
LED LIGHT SOURCE
• High intensity red LED
• Pulse modulated
PUSH BUTTON CONTROL
• Automatic set-up routines based on web opacity
• One push button set-up
• Simultaneously pushing both buttons inverts the output
HYSTERESIS
• Minimal hysteresis promotes the detection between the
backing material and the label depending on the settings
LIGHT IMMUNITY
• Responds to sensor’s pulsed modulated light source …
immune to most ambient light
INDICATORS
• Green LED flashes when AUTOSET routine is activated and
stays illuminated when AUTOSET is completed
• Red LED illuminates when sensors output transistors are
“ON”.
Note: The status of the output transistors can be inverted by
pushing both buttons simultaneously.
AMBIENT TEMPERATURE
• –40°C to 70°C (-40°F to 158°F)
RUGGED CONSTRUCTION
• Chemical resistance to harsh cleaners such as detergents,
alcohols, and ketones
• Waterproof, ratings: NEMA 2
• Conforms to heavy industry grade CE and UL requirements
Model Numbers:
Label•Eye Description
LER Red LED, 4 conductor 6 ft. cable
LERC Red LED, 4-pin Nano connector
LERR Red LED, 5 Conductor, 6 ft. Cable
LERRC-M12 Red LED, 5-Pin M12 Pigtail Connector
LERC-M12 Red LED, 4-Pin M12 Pigtail Connector
This manual suits for next models