1.1 Use
The sensors 02LINE 10020076 are designed to measure the outside ambient temperature and
transmit it wirelessly to a matched receiver. As the sensor is supplied by a solar cell, it is
maintenance-free. As soon as the change in temperature exceeds +/-1°C, a signal is sent
immediately. Moreover the signal is retransmitted every 15 minutes.
Note: Read the operating manual carefully before initial use.
1.2 Guarantee terms
This operating manual is an integral part of the device and our guarantee terms. It must always be
delivered to the user. We reserve the right to modify the technical design of these devices without
warning. TRI02SYS products are manufactured and their quality checked by making use of the
latest technologies and taking into account the applicable national and international directives. If
nevertheless a fault arises, TRI02SYS undertakes to remedy the default as follows, without
prejudicing the rights of the end customer that arise from the sales contract with his reseller:
If the event of exercising of a legitimate and regular right, TRI02SYS, may at its sole discretion,
rectify the device fault or supply a fault-free device. Any claim beyond this and all claims for
consequential damages are excluded.
A legitimate fault exists if the device cannot be used at the time of delivery to the end customer
because of a design or manufacturing defect or if its practical use is severely limited. The guarantee
is void in cases of natural wear and tear, incorrect use, incorrect connection, where the device has
been repaired or external influence. The period of guarantee is 24 months (from the date of
invoicing). French law applies to the regulation of guarantee rights.
1.3 Recycling of the device
To recycle the device, conform to the legislation and standards in force in the country of
use.
The casing is made from recyclable plastic.
Installation and operating manual
Exterior temperature sensor -30/+50°C
Ref. 10020076
EN
1. General
TRI02SYS sarl –8 grande rue le village 21160 FLAVIGNEROT
TOC1408NUENa_1214 2/4
Observe the following points:
• The laws, standards and directives in force.
• Best practice at the time of installation
• The device operating manual.
• An operating manual can only give general instructions. They must be interpreted in the context of
a specific installation.
The device is intended solely for use conforming to its purpose. Any repairs or modifications by the
user are forbidden! Do not use with other devices the operation of which could endanger people,
animals or property.
Note: The signal strength between the transmitter and the receiver decreases as the distance
increases. Where there is a line of sight connection, the range is approximately 30 m in corridors
and 100 m in large workshops or halls. The range can be increased with an 02LINE repeater.
General characteristics
Transmission frequency
868.3 MHz
Transmission power
10 mW max.
2. Safety
3. Technical characteristics
EnOcean Equipment Profile
A5-02-13
Measurement range
from -30°C to +50°C
Measurement resolution
0.314°C
Storage temperature
From -20°C to +60°C
Illumination
>100 lux on average per day
Degree of protection
IP 54, on its base
Range in buildings
Masonry
20m, through 3 walls at most
Reinforced concrete
10m, through 1 wall/ceiling at most
Plasterboard / wood
30m, through 5 walls at most
Installation altitude
2000m max.
Measurement accuracy
+/- 1°C from -5°C to +35°C
+/- 1.5°C from -30°C to +50°C
TOC1408NUENa_1214 3/4
The sensor is supplied on a base which as well as installation allows a learn process to be
performed close to the matched receiver by separating (using a small screwdriver to depress the
clips) the sensor from the base; the base remaining in position.
Base clip
4.1 Installation instructions:
Never mount the sensor in a metallic casing or close to a largely metallic object.
Installation on the ground or close to the ground is not recommended
The sensor must be positioned so that air can circulate freely around it and within an area
representative of the temperature to be measured.
Secure the base by gluing or screwing.
Place the sensor on its base until it engages.
4.2 Initial use:
The devices are supplied in an operational state but will probably require recharging, following
storage of the radio sensors in the dark.
Prior to first use, charge the sensor's power reserve using light with an illuminance of at least
200 lux for 5 minutes or more.
Ensure that averaged across the day, the mean illuminance is 100 lux/d.
The sensor's operating power reserve (when fully charged) in conditions of total darkness is 4
days.
Note: The device is designed for external use. To clean, use a damp cloth!
10020076 sensors transmit the measured temperatures using the frame described in the EnOcean
Equipment Profiles EEP2.1 document §A5-02-13 (consultable under www.enocean.com).
5.1 Temperature measurement:
The temperature is measured every 100 seconds. If the temperature change between two
measurements exceeds +/-1°C, a signal is sent.
If the change remains below this level, the temperature is transmitted approximately every 15
minutes.
5.2 Programming and LRN button:
A single press of the LRN button causes the sending of
a frame for identification or association of a matched
receiver.
When the sensor is located on its base, it must be first
unclipped from the base to access the LRN button and
to place the sensor closed to the matched receiver
during the identification or association phase (the
receiver having reduced sensitivity during this phase).
78 mm
25 mm
LRN button
4. Installation and initial use
5. Controls and functions
ion and initial use
TOC1408NUENa_1214 4/4
6.1 New or existing installation
• If the receiver functions at a shorter distance relative to the sensor, it is subject to interference or
used outside the transmission range.
• Search the system environment for changes that could cause the interference (for example
movement of metallic cabinets, furniture or partitions).
• Use the sensor or receiver in a more suitable location.
• Clear the receiver and perform a new learn process.
6.2 Limitation of the range of the radio signals
• Transmitter/receiver used close to metallic objects or close to materials containing metallic
elements. Observe a distance of at least 10 cm.
• Humidity in the materials.
• Devices emitting high frequency signals such as audio and video systems, computers, electronic
ballasts or fluorescent tubes. Observe a distance of at least 0.5 m.
6.3 Contacts
E-mail:............................ [email protected]
This product can be sold and operated in the countries of the European Union. TRI02SYS hereby
declares that the receiver 10020076 complies with the essential requirements and other relevant
prescriptions of Directive 1999/5/EC R&TTE. For more details on the applied standards please
consult website www.trio2sys.fr D.Girard
6. Troubleshooting
ion and initial use
7. Declaration of conformity

Popular Temperature Controllers manuals by other brands

AKO AKO-16523-V manual

AKO

AKO AKO-16523-V manual

KEY RK-2006LPP Operation manual

KEY

KEY RK-2006LPP Operation manual

Climax Technology TS-9EL manual

Climax Technology

Climax Technology TS-9EL manual

Franke EVCO EVKB21N7VCXSX Service manual

Franke

Franke EVCO EVKB21N7VCXSX Service manual

ILX Lightwave LDT-5900 Series user guide

ILX Lightwave

ILX Lightwave LDT-5900 Series user guide

Hugo Müller TS 3.10 KNX Series instruction manual

Hugo Müller

Hugo Müller TS 3.10 KNX Series instruction manual

Veris TE series installation guide

Veris

Veris TE series installation guide

METER ES-2 Operator's manual

METER

METER ES-2 Operator's manual

dixell IC200CX Series Quick reference guide

dixell

dixell IC200CX Series Quick reference guide

tiko Energy Solutions Sense-3 user manual

tiko Energy Solutions

tiko Energy Solutions Sense-3 user manual

ELEKTRA DIGI2 installation manual

ELEKTRA

ELEKTRA DIGI2 installation manual

Makeblock DS18B20 manual

Makeblock

Makeblock DS18B20 manual

Honeywell T7560A installation instructions

Honeywell

Honeywell T7560A installation instructions

Auber Instruments TD120-W Supplementary manual

Auber Instruments

Auber Instruments TD120-W Supplementary manual

dixell XW360K Installing and operating insructions

dixell

dixell XW360K Installing and operating insructions

Jaga CLIMA CANAL-JDPC user manual

Jaga

Jaga CLIMA CANAL-JDPC user manual

Jackson Systems THE GREEN ZONE Z-200-HC-MS Installation and operation instructions

Jackson Systems

Jackson Systems THE GREEN ZONE Z-200-HC-MS Installation and operation instructions

Conotec FOX-23AF operating manual

Conotec

Conotec FOX-23AF operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.