Tricel Puraflo 1-50 User manual

1
124 Rev 4 Jan 2019
Tricel
®
Puraflo 1-50
Installation
Wastewater Treatment Plants
Engineering a green future

2
Contents
Contents ...............................................................................................................................................................2
1Health & Safety precautions.....................................................................................................................3
1.1 General..............................................................................................................................3
1.2
Electrical/maintenance
................................................................................................. 4
1.3 Installation: .......................................................................................................................4
2
Installation
..................................................................................................................................................5
2.1 Inspection on reception of Tricel Puraflo modules ...........................................................5
2.2 Positioning and precautions..............................................................................................5
2.3 Tricel Puraflo systems: 1 - 11PE (max. 4 modules) ...........................................................6
2.3.1 Puraflo module installation – step by step guide ...................................................................6
2.3.2 Septic tank effluent filter installation (secondary treatment only) .................................10
2.4 Tricel Puraflo systems: 12 - 50 PE ...................................................................................13
2.4.1 Indexing valve .............................................................................................................................13
2.4.2 Indexing valve – step by step installation procedure ..........................................................13
2.5 Electrical requirements...................................................................................................16
2.5.1
Tricel Puraflo [gravity outlet] control panel wiring schematic
....................................16
3Commissioning..........................................................................................................................................17

3
1Health & Safety precautions
This manual contains basic information on the installation, operation and maintenance of the
Tricel Puraflo wastewater treatment system. For this reason, it is essential that these
instructions are carefully read and understood before installation or commissioning by both
the installation crew as well as those responsible for the operation and maintenance of the
system.
This manual shouldbereadilyavailableatthelocationofthesystem.Itistheresponsibility of the
homeowner to ensure that the wastewater treatment system is operated and maintained
correctly and in a safe manner at all times.As safety and security are of vital importance, the
following aspects are critical:
1.1 General
•
Ensure that all the information contained in this manual is adhered to at all times.
•
Treated wastewater is not suitable for human consumption
. It is unhealthy for humans,
pets, and wildlife to drink or come in contact with surface or ground water contaminated
with sewage.
•
It is importantthatlocksarefitted to the lid to preventaccidentalaccess.
•
Neverentera tank,unless qualifiedtodoso.
•
Nakedflamesshall not be usedinthevicinityof thetank due tothe danger of combustion.
•
The manhole covers shall never be left off an unattended tank. Always lock the covers
of the plant when work is completed.
•
Sewage and sewage effluent can carry micro-organisms and gases harmful to human
health.
•
Any person carrying out work on the
wastewater treatment system
must be
appropriately trained.
•
Suitable protective clothing; including waterproof/abrasion-resistantgloves,
overalls,
safetyfootwear, eye,earandrespiratoryprotection, goggles (facevisorsare particularly
effective against splashes) should be worn at all times. All protective clothing must be
ingood condition and be fit for its intended purpose.
•
Always remove contaminated clothing and protective equipment after working with
wastewater treatment plants.Wash hands and face priorto eating,drinkingorsmoking.
•
Wastewater treatment plants contain very low levels of oxygen. Hydrogen sulphide,
methane, carbon dioxide and other
life-threatening gases are also present. Tanks
have manholes covers to provide access to the tank only in times of cleaning and
inspecting the tank from outside.The manhole covers must always be in place and
secure.
•
Keep vehicles and other heavy equipment away from the wastewater treatment plant
and percolation area.
•
Erect a safety barrier around open manholes to prevent anyone from accidently falling
down the manholes.
•
Keepchildrenawayfromthesepticsystemwhenitisbeing workedon.
•
Do not smoke near wastewater treatment plants. Combustible gases could be present
andcausean explosion.
•
Contact a plumber or other qualified person if you smell 'sewer gases'. They can identify
the source and correctitimmediately.
•
The sewage treatment process uses many beneficial microorganisms, like bacteria, in
the treatment process.
However, the plant also contains harmful bacteria, viruses and
disease-organisms.
Liquid and solid contents of the septic system are capable of causing
infectious diseases.

4
1.2
Electrical/maintenance
•All electrical work to be carried out by competent persons using suitable materials for the
application.
•Do not open the Tricel Puraflo alarm cover without firstly isolating the mains power.
All
power isolation switches should be turned off [Follow Lock-out/Tag-Out Procedure]
before any maintenance/inspection work is done at the wastewater treatment plant.
•Never use electrical lights, appliances or power tools in or close to water or wet ground
near the septic tank or percolation area. This can result in electrical shock or explosion.
•Electrical work must be carried out strictly to the manufacturer’s instructions and to the
relevant national rules for electrical installations.
All connections to the control panel
should only be made by competent qualified personnel. If a cable is damaged, it should
be replaced immediately to prevent electrical shock or damage to the electrical
equipment. All electrical connections are completed on site.
•When working with machinery/electrical equipment, proximity of water shall be noted.
Electrical equipment shall not be wet when working with it.
•
There is potentialdanger when de-sludgingand thereforethis shall neverbe done alone.
•
A wastewater treatment system that fails to fully treat sewage due to poor
maintenance or overloading may allow excess nutrients (phosphorus and nitrogen) to
reach nearby lakes and streams, promoting algae and plant growth. Algal blooms and
abundant weeds may make lakes unpleasant for swimming, boating, and other water-
based activities. This plant growth can also affect water quality for fish and wildlife
habitat. As plants die and settle to the bottom, they are brokendownbybacteriathat use
upoxygen that fish needtosurvive.
•
It is the responsibility of the owner to ensure that the wastewater treatment plant is
operatedand maintained correctly at all times.
•
It is advised that the owner enters into a yearly Service Agreement to ensure the correct
operationoftheirwastewatertreatmentplant.
1.3 Installation:
•
Excavationwork should be plannedwithdueregard tohealth andsafetyrequirements.
•
Septic tank should also be properly vented in accordance with the tank
manufacturer’s guidelines.
•
Excavated material should either beshoredor batteredbacktoa“safe”angle.
•
Use appropriate liftingequipment.
•
Careshouldbetakenaroundgroundsworkmachinery.
•
Keepproper footing and balance at all time.
•
Tricel Puraflo modules are supplied with ropes for lifting purposes. The modules are
designed for a single lift when placing them in position.

5
2
Installation
Important
Prior to the installation of the Tricel Puraflo system, it is important to carefully read these
installation instructions.
2.1 Inspection on reception of Tricel Puraflo modules
•
Tricel Puraflo modules should be visually inspected for damage which may have
occurred during transport prior to installation. Any damage should be notified to
the delivery driver and/or to your supplier. Do not attempt to carry out any
unauthorisedrepairs,as thiswillinvalidatethewarrantyon the modules.
•
Oncethe modules have beeninstalled,wecannotacceptanyclaimsfordamage.
2.2 Positioning and precautions
•Only suitably qualified personnel should perform the installation of the Tricel
Puraflo system.
•The groundwater level on the site must never rise above the base of the Tricel Puraflo
modules.
•
Suitably sized equipment will be required to excavate the hole and to lift the
Tricel
Puraflo system
into place (minimum: 6-ton machine).
•The Tricel Puraflo system should not be installed in an area subject to flooding or excessive
water runoff as no flood waters should enter the tank.
•
When selecting the location of the Tricel Puraflo system, ensure that it is always accessible
for future maintenance.
•A septic tank must be installed (or de-sludged if a retrofit installation) and empty, but not
in use, during the installation of the Tricel Puraflo system. Tricel offer septic tanks with an
effluent filter fitted if required.
•The location for each element of the system must be known and marked out prior to
installation.
•In the case of tertiary treatment systems that discharge to a gravel base, the discharge area
must be installed before the Tricel Puraflo system is installed. Tricel is not responsible for
the design and installation of the discharge area.

6
2.3 Tricel Puraflo systems: 1 - 11PE (max. 4 modules)
2.3.1 Puraflo module installation – step by step guide
Steps
Description
Secondary treatment
Tertiary treatment
Site
preparation 1
The location for each element of the system must be known and marked out.
Install pre-
module
treatment
2
Prepare excavation as per manufacturer's guidelines.
3
Install septic tank as per
manufacturer's guidelines.
Install WWTP as per manufacturer's
guidelines.
Install effluent
filter 4
Install effluent filter at outlet of
septic tank. For more information
on the effluent filter, please see
section 5.3.2.
Install pump
chamber
(if required)
5
Prepare excavation as per manufacturer's guidelines.
6
Install pump chamber as per manufacturer's guidelines.
Install Puraflo
Modules 7
Excavate a hole that will allow for
a minimum 275mm gravel base
beneath the Puraflo modules
(taking note of water table and
other site conditions). Puraflo
modules can be installed above
ground or so that the lids are level
with the ground level but the lids
must never be covered.
The gravel base must extend
minimum 500mm beyond the
footprint of the Puraflo modules
on all sides.
Excavate a hole that will allow for a
minimum 300m gravel base beneath the
Puraflo modules (taking note of water
table and other site conditions). Puraflo
modules can be installed above ground or
so that the lids are level with the ground
level but the lids must never be covered.
The size of the area covered by the gravel
base is determined by the following
formula:
Area = PE * T * 0.125 (EPA CoP)

7
8
Lay a gravel base (10-20mm pea
gravel) to a height of 200mm.
Ensure the gravel base is level.
Lay a gravel base (10-20mm pea gravel) to
a height of 225mm. Ensure the gravel base
is level.
9
Place the lentils on the gravel base perpendicular to the length of the modules.
The 100mm side of the lentils must lie flat on the gravel base. Ensure that each
lentil is level.
The lentils must be spaced far enough apart that each module is supported at
the locations outlined in the following image:
10
Continue filling the excavation with gravel (10-20mm pea gravel) until the
height of the gravel is level with the top of the lentils. The gravel must be
levelled.
11
A trench, for the rising main, must be dug from the pump chamber/water
treatment plant to the Puraflo modules inlet assembly. We recommend a
300mm wide trench with a 650mm depth. The rising main must be surrounded
by 150mm of gravel all around. The rising main pipe should be 500mm below
ground level to prevent freezing. Backfill the rest of the trench with existing
soil.
12
Using the glue provided, the 32mm PVC outlet pipes must be attached to all
modules before they are placed alongside each other as the pipework that feeds
into the sample chamber(s) will be inaccessible when the modules are in place.
13
Using the lifting ropes, lift the Puraflo modules into position, according to the
layouts in Section 3.3, taking note of the left and right-hand alignments marked
on the modules. Position the modules until they are just touching and they form
a V where they meet at the outlet.

8
14
The lifting ropes should be pulled down below the modules for better
aesthetics.
15
Create a hole 225mm deep in the gravel base where the sampling chamber will
be located. Install the sampling chamber(s) so that the ledge fits under the Tricel
Puraflo modules and into the 'V' shape between the modules.
16
Install the remaining outer PVC pipes and connect them into sampling chamber.
Once the pipework has been connected, build up the level of the pea-gravel
directly beneath the pipework to provide support during the backfilling around
the modules. This will prevent damage or sagging to the pipework which could
result in blockages or leaks.

9
17
Using the yellow inlet pipe assembly provided, connect the inlet pipework to
each module. The rising main coming from the pump chamber/water treatment
system should be connected to this inlet assembly in single zone systems (The
rising main must be connected to the inlet of the indexing valve in multi-zone
systems). The following images show the completed inlet assemblies of the 2,
3 & 4 module systems:
Tricel Puraflo 2-module inlet assembly
Tricel Puraflo 3-module inlet assembly
Tricel Puraflo 4-module inlet assembly

10
18
Once the rising main has been connected to the Puraflo modules, backfilling
around the modules can be completed.
Note:
•
The Tricel Puraflo modules must not be covered with soil.
•
It is important that the outlet pipework is protected from sunlight and
frost damage by ensuring that around the Tricel Puraflo modules is
backfilled with suitable material.
2.3.2 Septic tank effluent filter installation (secondary treatment only)
•Secondary treatment Tricel Puraflo systems require an effluent filter be installed at the
outlet of the septic tank.
oOn sites in which complete secondary treatment systems i.e. septic tank AND Tricel
Puraflo modules, are being installed, the effluent filter must be installed in the
septic tank on site by the installer unless the septic tank has been supplied with the
effluent filter pre-installed, see section 5.3.2.1.
oOn sites in which a Tricel Puraflo system will be installed with a pre-existing septic
tank, an effluent filter must be installed at the outlet of the septic tank, if not
already present.

11
2.3.2.1
Vento septic tank – effluent filter installation procedure
Step
Description
1
Remove the filter bag and filter bag housing from the outlet of the Vento septic tank.
2
Glue the 200mm length 110mm (4") diameter
sewer pipe to the outlet of Vento septic tank.
3
Fit the euro reducer into the effluent filter. Apply
PVC sealant around the end of the 110mm pipe and
push the effluent filter onto the pipe. Secure the
effluent filter using a self-tapping screw in the
location indicated by the arrow.

12
2.3.2.2
3rd party septic tank - effluent filter installation procedure
Step
Description
1
Remove T-piece, if present.
2
Fit the euro reducer into the effluent filter.
Apply PVC sealant around the end of the 200mm
110mm pipe and push the effluent filter onto
the pipe. Secure the effluent filter using a self-
tapping screw in the location indicated by the
arrow.
3
To facilitate access to the effluent filter when
installed in the tank. The 110mm (4”) sewer
pipe outlet may need to be extended inside the
septic tank using straight coupler, as shown.
Access to the effluent filter is required for
maintenance and removal.

13
2.4 Tricel Puraflo systems: 12 - 50 PE
•Tricel Puraflo systems designed for 12-50PE consist of multiple zones, which in turn consist
of two, three or four modules per zone.
•Wastewater is pumped to each zone intermittently via an indexing valve, which is
positioned between the pump chamber and the Puraflo modules.
2.4.1 Indexing valve
•There are two types of indexing valve. The indexing valve supplied is determined by the
number of zones in the Tricel Puraflo system.
o6-outlet indexing valve: Used in systems of 5 - 6 zones
o4-outlet indexing value: Used in systems of 2 - 4 zones
2.4.2 Indexing valve – step by step installation procedure
Step
Description
1
Apply PTFE tape to threads of Philmac
fitting and thread into inlet of indexing
valve.

14
2
Assemble each of the active outlets required as shown below:
1. Indexing valve
2. Threaded pipe (supplied with valve)
3. Union nut
4. Union end
5. 50mm length of 32mm pipe
6. 40-32mm reducing bush
7. 40mm elbow
Note: The elbow (object 7. above) can be orientated to suit the installation.
3
Push hose tails into the flexible outlet
pipework and secure with hose clips.

15
4
Using a 50mm hole saw, drill the inlet
hole and the required number of outlet
holes. The inlet hole/outlet holes can be
positioned at alternative locations
around the bottom of the distribution box
to suit the site conditions.
5
Place the indexing valve into the
distribution box, connect the outlet pipes
(to Puraflo modules) and inlet pipe (from
the pump chamber) to the indexing valve.
6
Secure distribution box riser in place
using six 25mm pan screws.
7
Position the indexing valve as close to the
Puraflo modules as site conditions allow.

16
2.5 Electrical requirements
Important:
Please ensure the electrical installation complies with all national regulations and
requirements.
The customers’ minimum responsibility shall consist in the provision of:
•The power supply SWA cable(s) must be suitably sized and comply with all national
regulations and requirements. The sizing of the cable is the responsibility of a qualified
electrician.
•A qualified electrician is required make the final electrical connections to the control &
alarm panel.
•
Thecablearmourmustbe properlybondedtothe mainearth.
2.5.1
Tricel Puraflo [gravity outlet] control panel wiring schematic

17
3Commissioning
Important
The commissioning of a Tricel Puraflo system must only be done by a Tricel- approved service
technician.
•It is important Tricel commission the Tricel Puraflo system to verify that the system has
been installed correctly and ensure that the Tricel Puraflo will achieve the required
treatment levels.
•The commissioning of the Tricel Puraflo system is done as part of the installation, when
installed by Tricel.

18
This page is intentionally left blank

19
This page is intentionally left blank

20
Product Product
Code
Nominal Organic
Daily Load
(BOD5) (kg/day)
Nominal Hydraulic
Daily Flow
(QN)(litres/day)
6P Puraflo Secondary
221342
0.36 900
6P Puraflo Tertiary
221355
0.36
900
9P Puraflo Secondary
221343
0.54 1350
9P Puraflo Tertiary
221356
0.54
1350
11P Puraflo Secondary
221344
0.66 1650
11P Puraflo Tertiary
221357
0.66
1650
15P Puraflo Secondary
221345
0.9 2250
15P Puraflo Tertiary
221358
0.9
2250
21P Puraflo Secondary
221346
1.26 3150
21P Puraflo Tertiary
221359
1.26
3150
24P Puraflo Secondary
221347
1.44 3600
24P Puraflo Tertiary
221360
1.44
3600
27P Puraflo Secondary
221348
1.62 4050
27P Puraflo Tertiary
221361
1.62
4050
33P Puraflo Secondary
221349
1.98 4950
33P Puraflo Tertiary
221362
1.98
4950
42P Puraflo Secondary
221350
2.52 6300
42P Puraflo Tertiary
221363
2.52
6300
45P Puraflo Secondary
221351
2.7 6750
45P Puraflo Tertiary
221364
2.7
6750
50P Puraflo Secondary
221352
3 7500
50P Puraflo Tertiary
221365
3
7500
Tricel (Killarney) Unlimited Company Trading as Tricel
Ballyspillane Ind. Est. Killarney, Co. Kerry, Ireland
Tricel Environmental UK, A trading brand of Dewey Waters Ltd
Heritage Works, Winterstoke Road, Weston-super-Mare, BS24 9AN, United Kingdom
In accordance with Tricel’s normal policy of product development these specifications are subject to change
without notice.
Table of contents
Other Tricel Lawn And Garden Equipment manuals