Important Safety Instructions
SAVE THESE INSTRUCTIONS
All sections of this manual contain instructions and warnings that should be followed during the installation and use of the SmartRack Enclosures
described in this manual. Read all instructions and warnings thoroughly before attempting to move, install or use the SmartRack Enclosures described in
this manual. Failure to comply will create a risk of personal injury and property damage and may invalidate the warranty.
• Keep the enclosure in a controlled indoor environment, away from moisture, temperature extremes, flammable liquids and gasses, conductive contaminants, dust and
direct sunlight.
• Leave adequate space at the front and rear of the enclosure for proper ventilation. Do not block, cover or insert objects into the external ventilation openings of
the enclosure.
• The enclosure is extremely heavy. Use caution when handling the enclosure. Do not attempt to unpack, move or install it unassisted. Use a mechanical device such as a
forklift or pallet jack to move the enclosure in the shipping container.
• Do not place any object on the enclosure, especially containers of liquid, and do not attempt to stack the enclosures.
• Inspect the shipping container and the enclosure for shipping damage. Do not use the enclosure if it is damaged.
• Leave the enclosure in the shipping container until it has been moved as close to the final installation location as possible. The casters are designed for minor position
adjustments within the final installation area only. The casters are not designed for moving the enclosure over longer distances.
• The casters are not designed to provide long-term support for the enclosure after final installation. Use the levelers to provide long-term support.
• Install the enclosure in a structurally sound area with a level floor that is able to bear the weight of the enclosure, all equipment that will be installed in the enclosure
and any other enclosures and/or equipment that will be installed nearby.
• Do not push the enclosure from the side panels to move it. Pushing from the side panels will cause a tipping hazard.
• When rolling the enclosure on its casters, always push it from behind, never pull it toward you.
• A rolling enclosure can cause personal injury and property damage if not properly supervised. If rolling the enclosure down a ramp is required, use extreme caution.
Do not attempt to use ramps that have a slope steeper than 1:12.
• Use caution when cutting packing materials. The enclosure could be scratched, causing damage not covered by the warranty.
• Save all packing materials for later use. Repacking and shipping the enclosure without the original packing materials may cause product damage that will void the warranty.
• Do not re-ship the enclosure with additional equipment unless the enclosure was shipped with a special shock pallet (“SP1” models only). The combined weight of the
enclosure and installed equipment must not exceed the load capacity of the pallet. Tripp Lite is not responsible for any damage that occurs during re-shipment.
• Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to
significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or
nitrous oxide.
Overview
SmartRack Enclosures accommodate all standard 19-
inch rackmount equipment, regardless of vendor, and
ship fully assembled for quick and easy deployment.
They feature adaptable, heavy-duty cabinets in 25U,
42U and 48U heights, with or without side panels.
Several models are available with an integrated shock
pallet that allows resellers, integrators and enterprise
customers to pre-configure equipment and re-ship the
enclosures to the final installation site.
SmartRack Enclosures have variable mounting depths,
ideal for servers. Integrated baying hardware enables
cost-effective, orderly and efficient expansion. The
cabinets include quick-release doors and side panels
for convenient maintenance and split rear doors for
improved access and reduced clearance requirements.
Front access doors are reversible for installation
flexibility. Front and rear doors and side panels are
lockable.
Available SmartRack Enclosures
Model # Rack Height Side Panels Shock Pallet
SR25UB 25U Yes No
SR25UBEXP 25U No No
SR25UBSP1 25U Yes Yes
SR25UBEXPSP1 25U No Yes
SR42UB 42U Yes No
SR42UBEXP 42U No No
SR42UBSP1 42U Yes Yes
SR42UBEXPSP1 42U No Yes
SR48UB 48U Yes No
SR48UBEXP 48U No No
SR48UBSP1 48U Yes Yes
SR48UBEXPSP1 48U No Yes
See the Specifications section for more information.