TRM TRM-FH-Silver User manual

TRM-FH-Silver
Quick Start Guide
Programmable Radiant Floor Thermostat
Installation:
1.Loosen the bottom screw using a Phillips screwdriver, then open the thermostat from the below
as shown in figure 1:
Note: The bottom screw does not need to be removed to detach
the faceplate.
GFCI Testing steps:
Note: Do not press and hold the test button
Note: In daily use, if the RED light is ON and the “Ground Fault” message appears on the screen, you need
to check if the ground fault is actually present by pressing the [Reset] button.If the red light is off and the
screen display returns to the operating menu the unit has nuisance tripped, or been manually tested. If the
ground fault message persist when you attempt to heat up the floor, you may have an actual fault. Contact
your installer for troubleshooting support.
2. Wire the thermostat as shown in figure 2:
L/N (Line):Connect incoming power supply to the terminal
block.
L1/N1 (Load): Connect the heating load wires to the
terminal block
(Above wiring screws should be torqued between 0.7-1.0 N.m)
Ensure the junction box is grounded, and attach the heating
cable ground to this location.
3. Install the power base into the junction box and secure it using
the supplied set screws as shown in Figure 3.
(Screws should be torqued to approx 0.1-0.2 N.m)
4. Install the thermostat faceplate on the power base; start by
aligning the top of the units, then swing the faceplate down so it
comes to rest on top of the power base, with the screw holes lined
up; tighten the screw to secure the faceplate to the power-base.
6. Turn ON the thermostat and wait for the operating screen to be
displayed.
5. Turn ON the power source (feed breaker).
7. Test the thermostat GFCI by pressing the top button marked
'Test'; a Ground Fault message will be displayed on the thermostat screen.
8. Reset the thermostat GFCI by pressing the top button marked 'Reset'; the Ground Fault
message will disappear and the thermostat operating screen will be displayed.
Warnings:
-Installation or replacement of this product should only be done by qualified personnel.
-To avoid risk of electric shock, turn OFF the power source from the main service panel prior to
installation of the thermostat.
-Keep thermostat air vents clean and free from obstructions.
-Electric floor heating cable/mat must be in accordance with the thermostat supply voltage.
-All wiring must conform to local as well as national electrical codes and ordinances.
-Power and Load terminals (L/N/L1/N1) are designed to handle a cross-section of wire measuring
12-22AWG.
-Sensor terminals (A/B/C/D) are designed to handle a cross-section of wire measuring 18-22AWG.
Supply voltage: 120V/208V/240V 50/60 Hz
Load: Max.15 A (resistive load)
GFCI: Class A (5 mA trip level)
Setpoint range: +5 to +40°C / +41 to +104°F
Temperature range: +5 to +45°C / +41 to +113°F
Ground Fault Circuit Interrupter (GFCI):
This thermostat has a built-in GFCI function that protects people from electric shock. It is very
important to check whether the GFCI is functioning normally; the following testing process
should be done monthly:
2. Press the [Test] button. If a red light appears in the upper left corner of the thermostat and
GROUND FAULT appears on the screen, the GFCI is functioning normally. If there is no res-
ponse, contact your installer for troubleshooting assistance.
3. Press the [Reset] button.The red light will turn OFF and the thermostat will display the
operating screen.
Operation:
The thermostat controls your floor heating system based on built-in weekly program, running in
4 or 2 stages per day, 7 days a week.
The default weekly program parameters satisfies most usage scenarios, however you can also
modify the weekly program parameters in the thermostat.
When there is no one in the house, it is recommended to reduce the temperature set-point to
save energy.
The thermostat also has built-in adaptive function. When this function is active, the thermostat
heats or stops heating in advance of next stage to bring the room temperature to the set temp-
erature of the next stage. Please note that after turning the Adaptive function ON, the thermostat
will require a few days of normal operation to learn the time required to achieve the heating
targets selected.
Functions:
Technical specification:
Temporary temperature setting
Please press the button for temporary temperature setting
Mode Menu
Mode selection
Auto Mode
Manual Mode
Away Mode
OFF
Menu
Heating Schedule
Energy Use
User Settings
Installer Settings
IN/SNR Terminal (C/D) (Floor Sensor):Connect the floor
sensor to this location on the thermostat there is no polarity to this connection.
If a spare (redundant) probe has been installed in the floor, tape this to the other probe wire in the junction
box, but ONLY CONNECT (1) SENSOR to the thermostat at any one time.
OUT Terminal (A/B) (External relay communication): Connect to IN/SNR on the Relay power
module (sold separately); used to expand a floor heating system beyond the 15 amp thermostat capacity.
1.Confirm that the thermostats is turned ON.
Mode selection
Menu selection
This thermostat provides three operating modes:
Automatic mode:
According tothe weekly program, the thermostat automatically adjuststhe set
temperature operation.
Manual mode:
The thermostat runs continuously according tothe set temperature.
Away mode:
OFF:
This mode is used when you want tokeep your room at a lower temperature when you
are away for an extended period of time.This operating mode prevents damage to
household/office equipment caused by sudden exposure to cold temperatures.
The set-point temperature Range is set to maintain from 41°F to 59°F(5°C -15°C) in this
mode.
Manually turn off all functions of the thermostat.When the device needs to be started,
Press and hold the on/off button in screen for 3s.
Temp Tolerance: Default 1°C /2°F
5023804
1
3
2
4
Refer to figure 4 for Junction box dimensions
If the thermostat does not reset, and continues to display a Ground Fault message,
contact your installer for troubleshooting support.
Dimensions (inches):
8:00
Wake : 21.0° 8:00
Mon
20.0°
Mode
Menu
21.0°
Auto Mode
12
4
3
5
6
9
10
11
7
8
12
Setting Temperature
Operating Mode
Up and Down Regulation
Mode Selection
Next Schedule
8
9
10
11
12 Menu Selection
GFCI Test Light
Temperature
GFCI Test Button
GFCI Reset Button
Heating
4
5
6
7
1
2
Time
3
3.2 0.7 1.3 1.9
2.8
3.2
5.1
50/60Hz
120/240V
L1 L N N1
LOAD
OUT A
OUT B
C
D
IN/SNR
1800W 3600W MAX 15A

Heating Schedule
Child lock: Lock all keys to prevent the setting from being changed.
Child lock: (Hold the up button on the main interface for 3s to unlock)
Date: Set date.
Time: Set Time.
Display Brightness: 1-9.
5-60
Unit:°F/°C.
Power Set: 0W-4500W.
When enabled,the thermostat will adjust automatically in daylight
saving time.
Daylight Saving Time:
Set Backlight Delay:
Language: English/Francais
Support:Scan the QR code to view the electronic manual.
For further support, please contact your installer.
User Reset: This will reset the users settings to factory default.
Adaptive Function: When this feature is enabled, the room will have
reached the target/set temperature when the event begins.If
Open Window: Thermostat can detect an open window and will
shut off heating temporarily to save energy.;
Sensor Type: B3950-10K/B3380-10K/B3700-10K/B3600-12K/15K
Sensor Application: 1.Room 2.Floor 3.Room and Floor Protection
Floor Sensor Calibration:Measure the temperature by adjusting
the calibration. ±5℃
Room Sensor Calibration:Measure the temperature by adjusting
the calibration. ±5℃
°
Floor Protection:
Factory Reset:This will reset the thermostat to factory settings, Personal
settings will be lost.
Location: Home/Office.
Floor protection is enabled only when the sensor
type is selected for room and floor simultaneously.If the floor temperature
exceeds the set protection value, the thermostat will display alarm information
and stop working.
Reference value:Laminate-max.28°C(82.4°F)/Tile-max.40°C(104°F)
The value ranges from 20°C(68°F)to 50°C(122°F).If
Energy Use
User Settings
Installer Settings
...... ......
Select days to program
MON
TUE
WED
THU
FRI
SAT
SUN
√
√
√√
√
7:00 22.0°
8:30 19.0°
17:00 22.0°
22:00 19.0°
1
2
3
4
√
Energy Use
0000KWh
Wake
Time
6:00 21.0°
Temp
√
User Settings
Time
Date
Child Lock
Unit
Power Set
Display Brightness
Language
Daylight Saving Time
Set Backlight Delay
Support
User Reset
Installer Settings
Adaptive Function
Open Window
Sensor Application
Sensor Type
Floor Sensor Calibration
Room Sensor Calibration
Floor Protection
Location
Factory Reset
No display
GFCI is tripped
Problem Solution
Trouble shooting:
Assign seven days a week to the following two schedules:
This option is used to calculate data on energy usage.The user sets the power in the Power Set.
The thermostat will automatically count the heating time and calculate the energy consumption.
5+1+1: The Event parameter is the same from Monday to Friday, with separate Event parameters
on Saturday and Sunday.
7: With separate Event parameters every day.
Period set
Note:Multiple days can be selected and programmed at the same time.
1.Check the you have 120V/208V or 240V supplied to the junction box.
2.Ensure power supply is connected to the Line side of the thermostat (L/N).
3.Contact your installer for troubleshooting support.
1. Refer to the GFCI Testing steps noted above.
2. Contact your installer for troubleshooting support.
Heating occurs
at wrong times
1. Check the scheduled times are set correctly AM/PM.
2. Confirm thermostat is set to the correct date/time.
3. Contact your installer for troubleshooting support.
1. Check the floor sensor is connected to IN/SNR terminals.
2. Check the floor sensor has a good ohms reading.
3. Contact your installer for troubleshooting support.
1.Contact your installer for troubleshooting support
Floor sensor
error
Air sensor error