TrolMaster HCS-1 User manual

PLEASE READ FIRST
Congratulations on your purchase of the TrolMaster HCS-1 Hydro-X Control
System. This unit is an efficient and affordable way to fully control your grow
rooms. To ensure safety, please read this instruction manual carefully before
installation and follow the instructions herein. It will provide detailed instructions
and guidelines that will help to set up the unit, and to understand the full
capability of this unit. Any use or application of this product, other than for its
original intended purposes are prohibited. Store this manual in a secure place
for future reference.
INTRODUCTION
Hydro-X Control System is the most intelligent and versatile environmental
control system on the market. It could control up to 512 lights, 4 temperature
devices, 2 humidity devices, 2 CO2 devices, 9 preprogram devices. With the
incredible flexibility, anyone could easily customize their own grow room system
for maximum yield.
The system comes with a 3-in-1 sensor detecting temperature, humidity & light.
A CO2 sensor is available for measuring CO2 level. When the measured value
exceeds your custom setting range, a warning message will be sent to your
smartphone. Smoke detectors are also available for smoke detection to alert you
if there is a fire. Hydro-X helps you to monitor your grow environments perfectly.
Hydro-X is specially designed to set up a daily lighting management for your
lighting system. Having 2 separate lines allows the user to create multiple
lighting layouts (and dimming sequence) based on their individual preferences.
This system can efficiently control your lighting system by running a schedule
with advanced functions like auto dimming, overheat shutdown, sunrise &
sunset simulation.

Hydro-X can control almost all kinds of devices in your grow rooms by its 4 types
of device stations. Temperature device stations, humidity device stations, CO2
device stations and program device stations are designed to be connected to
different devices for centralized control. Hydro-X offers a more smart and flexible
approach for the connection of the devices you want to be controlled.
Hydro-X keeps pace with the times, it has the ability to connect to the network
directly with a standard network cable. After downloading the app, you can
monitor and control the environment of your grow rooms anytime and anywhere.
You could read the historical data by graph on your smartphone and receive
warning messages if the growing environment exceeds your setpoints. A micro-
SD card is also available for data logging if the Internet is unavailable. With
Hydro-X, you can monitor and control the growing environment at your
fingertips.
FACTS
Here are some important things to consider when using the Hydro-X Control
System.
Each set of Hydro-X Control System can connect to one 3-in-1 sensor, one
CO2 sensor and up to 20 optional smoke detectors. The 3-in-1 sensor used to
detect temperature, humidity and light, the CO2 sensor used to detect CO2 level
and the smoke detectors are used to prevent fire.
Each lighting line MUST have a single wattage / type of xture connected to it.
You cannot mix xtures with different wattages on the same line interconnect
wiring. When connected to lights which are controlled by digital signal (such as
ThinkGrow DE ballast), 256 lights can be controlled on each line, with potentially
512 lights controlled in total. A lighting control adapter (signal converter) is
available for controlling the traditional lights which are controlled by analog
signal (0-10v), such as Gavita etc. Due to the limitation of the analog signal, the

system can control up to 40 traditional ballasts on each line, 80 traditional
ballasts in total on both lines.
Various devices (such as for Temp / Humid / CO2, etc.) can be connected to
this unit through 4 types of different Device Stations. Each device has its own
and dedicated device station, which can be purchased separately depending
your needs. Don't mix up device station for different device.
Sensors, Device Stations and Ballasts are connected to main controller by
using RJ12 cables to daisy-chain all the devices together. Each of the sensors
and devices stations comes with an RJ12 "T" splitter and RJ12 cables.Various
length pre-crimped RJ12 cables and additional T-shape splitters can be
purchased separately.
A maximum distance of 1000ft / 300 meters between the HCS-1 Hydro-X
Control System and the devices to be controlled.
Follow all local and national electrical codes for installation requirements.
The Hydro-X is designed for indoor use only. It is recommended to use our
Trolmaster's accessories for good performance.
COMPONENTS

1. Controller
2. Back Plate(Bracket)
3. 4ft RJ12 Cable
4. T-Shape Splitter
5. 12DC Power Supply
6. 3-in-1 Sensor
7. 16ft RJ12 Cable
INSTALLATION

Determine where to locate the main controller. The controller comes with a
simple to use DIN type bracket. Pull the 4 tabs outward to release the bracket
from the unit, mount the bracket to a wall or surface, place the unit back on the
bracket and press the 4 tabs back in to lock the unit in place. The
interconnecting RJ12 communication cables are available in different lengths,
select the correct length for your application. The HCS-1 Hydro-X Control
System is supplied with a 4ft and 16ft cable. These interconnecting RJ12 cables
are also available in lengths of 25ft and 50ft. Select the correct length for your
application.
CONNECTIONS


CONNECTIONS CONTINUED...
1. Power Connection:
Connect the plug-in power supply to the power (DC) connector.
2. Sensor connection:
Connect the RJ12 cable to the SENSORS connector and connect to a splitter on
the other end. Plug the 3-in-1 sensor to the splitter for connection. The other
connector on the splitter can be used to continuously connect to the next splitter.
Connect a CO2 sensor to the 2nd splitter. Repeat the procedure and connect
one or more smoke detector(s) if needed. Press the small button on the smoke
detector, the Hydro-X automatically assign an address to the unit sequentially.
3. Device Station Connection (main controller needs to be
powered on)
Connect the cable going from the DEVICES connector to the first Device Station
to be connected. Use the T-shape splitter and short RJ cable so that the first
cable can continue on to be connected to the next T-shape splitter (Device
Station) to be connected. Plug the Device Station to the wall outlet for power
supply. Press the small button on the device station, the system will
automatically assign an address to the device station in sequence. Repeat this
process until all device stations are connected to the main controller.
4. Light Connection
a ) For HID Lights
Connect the cable going from LINE 1 to the rst digital ballast to be connected.
Use the T-shape splitter and short RJ cable so that the first cable can continue
on to be connected to the next T-shape splitter (ballast) to be connected.Repeat

this process until all ballasts (fixtures) are connected to the LINE 1. Connect
more lights through the LINE 2 port. Same procedures applied for LINE 1.
b) For Traditional Lights
If connected to traditional lights which are controlled by analog (0-10v) such as
Gavita fixtures, a lighting control adapter (signal converter) is necessary to
convert the digital signal into analog signal. The connection is similar as above
but with a signed converter connected between ballast and controller. First,
connect the signal converter to the LINE 1 or LINE 2 connector and then
connect to a splitter on the other end. Finally, use another RJ12 cable to
connect between the splitter and the analog ballast. See the connection
diagram.
Each line can be set up to be a "staged" dimming zone. In other words, each
zone has its own independent dimming temperature setting as well as the
dimming actiaon. Having 2 lines allows the user to create multiple lighting
layouts (and dimming sequences) based on their individual preferences. Some
examples are shown below.

5. Internet Connection
This unit has the feature of connecting the network for remote control.User can
use a standard network cabale for connection thruogh the INTERNET connector
BUTTONS
The HCS-1 Hydro-X Control System is extremely easy to use. The backlit
128x128 LCD display will provide the user with the current conditions and
access all settings.All settings are accessed by using the 6 pushbuttons on the
front of the unit. The button functions are described below.
UP / DOWN : The Up and Down buttons move the cursor up and down to select
the item on the LCD display.
LEFT / RIGHT : The Left and Right buttons move the cursor to previous page or
next page, left item or right item.
BACK : The Back button goes backwards to the previous page.
ENTER : The Enter button is used to open the menu item to be changed as well
as to accept and save the new setting.

Familiarize yourself with the function of the 6 buttons on the front of the HCS-1
Hydro-X Control System in order to able to access settings, and to better
understand how to use the HCS-1 Hydro-X Control System to its greatest
potential.
START SETTINGS
Once you have connected all devices, sensors and fixtures to the HCS-1 Hydro-
X Control System, we can start using the unit.
Connect the plug-in power supply to the power connector on the bottom of
theHCS-1 Hydro-X Control System. HCS-1 Hydro-X Control System will turn on
and boot up.
If it is the first time you have used the HCS-1 Hydro-X Control System, when

you power on the HCS-1 Hydro-X Control System, the Welcome screen / page
will be displayed.
*NOTE : Press ENTER button to rst go to the Conguration page and begin set-
up.
Time Setting : please refer to P25 for the time setting so as to change the
default time into the current time before use.
MAIN MENU

1 ). The main menu displays three elements:
Temperature Value (��F) eg: 78.8��F
Humidity Value (%) eg: 20.2%
CO2 Level (PPM) eg: 1200 PPM
The top title bar indicates current date & time:
Month/Date eg: 09/07
Hour/Minute eg:18:20
Day Mode
Night Mode

Night Mode
Alarm Activated
Internect Connected
No Network Connection (no icon)
NOTE : Download the TrolMaster app from App Store or Google Play
2 ). On the Main Menu page, press LEFT button to get access to Devices
Status page. The screen will show devices in 3 states .
a ). State One : Highlighted and with "ON" indicates the device is connected
and under working condition (activated).
b ). State Two : Highlighted and without "ON" indicates the device is
connected but not under working condition (standby)
c ). StateThree : Non-highlighted indicates no device station connected to
this address.

3 ). On the Main Menu page, press RIGHT button to get access to Alarm
Message page. The LCD screen will show records of all alarm messages.
*NOTE :
a ). On the Devices Status page, the device states are not suitable to lighting
devices.The LCD screen will display the lighting status for two lighting lines L1 &
L2.
b ). Do not remove the Micro-SD card in the main screen (showing Temperature,
Humidity & CO2 ).Otherwise, it is easy to cause damage to the card.
SETTING PAGE

On the Main Menu page, Device Status page or Alarm Message page, press
ENTER button to get access to the SETTING page. The LCD screen will
display 6 subjects ( Light / Temp / Humid / CO2 / Program / System) as shown
on the picture. You can move the cursor (UP / DOWN / LEFT / RIGHT) to select
each subject you want to make setting.
LIGHTING SETTINGS

On the Setting page, select the Light subject and then press ENTER button
to confirm your selection. The screen will display Line 1 and Line 2. Press UP
button or DOWN button to select Line 1 or Line 2. Then press ENTER
button to get into the configuration page.

2 ) Use the UP and Down button to select the optional item. Press ENTER
button, the digits will be flashing, then press UP or DOWN button for change.
Finally, press ENTER button to confirm and save change.
Wattage : Select the wattage of ballast that will be connected to this line.
Output Max : Select the wattage that you would like to operate the fixtures in
increment of 25 watts. User can select any setting between 600 watts and 1150
watts for the 1000 watt fixture.
On at : The time of day that the lights for that LINE 1 will be turned ON.
Off at : The time of day that the lights for that LINE 1 will be turned OFF.

Dim at : Select the temperature you want the lights within each line to dim.
Stop at : The max temperature that the growing area can get to before shutting
down the lights. Normally, set at least 5oF up to 10 degrees F above the "Dim
at" setting.
Sun R/S time : simulate Sunrise and Sunset by slowly raising and lowering the
lighting level ( brightness). User can select from 0 minite(off) to 30 minutes in 5-
minute increments for the Sunrise / Sunset feature.
3 ) The lighiting configurations of Line 2 is same as the setting of Line 1.
TEMPERATURE SETTINGS

1 ) On the Setting page, select the Temp subject and then press ENTER button
to access the Temp setting page. Use the Up button or DOWN button
to select the device or Alarm Setting.

2 ) When the Device 1 is selected, user can set the temperatuesetpoint for Day /
Night mode for the Device 1. The unit will automatically turn ON the Temp
Device 1 when the measured temperature is ABOVE or BELOW the setpoint.
Press ENTER button and the Above or Below text will be flashing. Press UP or
DOWN button to change between Above and Below. Finally, press ENTER
button to confirm and save the change.
For example : Turn on device when temp Above setpoint for Cooling devices;
Turn on device when temp Below setpoint for Heating devices.
Use UP and DOWN button to select Day mode or Night mode, the selected item
will be highlighted. Press ENTER button and the current temperature value will
Table of contents
Other TrolMaster Control System manuals
Popular Control System manuals by other brands

Fly Sky
Fly Sky FS-MG41 user manual

HEIDENHAIN
HEIDENHAIN ND 780 Installation instruction

Honeywell
Honeywell Tradeline H1008D installation instructions

ADVANTAGE AIR
ADVANTAGE AIR MyAir5 Series user guide

Maxitrol
Maxitrol R300 operating instructions

TouchTronics
TouchTronics POWERTouch P1000 Series Service manual