TUFFA TANKS AdBlue 1350SLBFSAD Owner's manual

TUFFA
ADBLUE®
STATIONS
Installation, Operation and Servicing Manual Version 2.0.0
Models:
1350SLBFSAD | 2500HBFSAD | 3500VBFSAD | 6000VBFSAD | 10000VBFSAD | 15000VBFSAD


1
1. Introduction 2
2. Conditions of use 2
3. Safety 3
4. Product description 4
4.1 Productidentication 4
4.2 Productspecication 5
4.3 Product footprint 6
5. Transport & storage 9
6. Installation & commissioning 10
6.1 Installationguidelines 10
6.2 Systeminstallation 10
6.3 Systemlocation 10
6.4 Electricalrequirements 11
6.5 Electricalwiringdiagram 11
7. Operation of the system 13
7.1 Usingthesystem 13
7.2 Summaryofmainparts1350/2500 13
7.3 Summaryofmainparts3500/6000/10000/ 15000 14
7.4 FillingAdBlue®Station 15
7.5 DispensingAdBlue®intovehicle 15
7.6 Equipmentcomponents 16
8. Maintenance of the TUFFA TANKS 26
8.1Systemmaintenancetasks 26
8.2 Inspection by competent person 27
8.3Internalexaminationandcleaning 27
8.4Troubleshooting 28
8.5Tankmaintenancerecord 30
8.4AdBlue®deliverylog 32
9. Warranty 34
10. Contact 35
11. Guarantee registration 35
CONTENTS PAGE

2
1. Introduction
Thismanualcontainsspecicinstructionsandinformationrelatingtotheinstallation,
operationandmaintenanceofTuaTankssystems.
2. Conditions of use
• Readthismanualbeforeinstallingthissystem.
• TuaTanksacceptsnoliabilityforpersonalinjuryorpropertydamageresultingfrom
workingonoradjustingtheequipmentincorrectlyorwithoutauthorisation.
• TuaTanksacceptsnoliabilityfordirect,indirect,incidental,special,or
consequentialdamagesresultingfromfailuretofollowanywarnings,instructions,and
proceduressetoutinthismanual.
• TuaTanksreservestherighttochangethespecicationsofitsproductsorthe
informationinthismanualwithoutnecessarilynotifyingitsusers.
• VariationsininstallationandoperatingconditionsmayaecttheTuaTanksystems
performance.TuaTanksmakesnorepresentationsorwarrantiesconcerningthe
performanceofthetanksystemundertheoperatingconditionsprevailingatthe
installation.
• OnlypartssuppliedbyorapprovedbyTuaTanksmustbeusedandno
unauthorisedmodicationstothehardwareorsoftwareshouldbemade.Theuseof
non-approvedpartsormodicationswillvoidallwarrantiesandapprovalsandcould
leadtohazardoussafetyconditions.
• Unlessotherwisenoted,referencestobrandnames,productnames,ortrademarks
constitutetheintellectualpropertyoftheownerthereof.
1. INTRODUCTION | 2. CONDITIONS OF USE

3
3. Safety
PLEASE READ THIS MANUAL CAREFULLY BEFORE USE & COMPLY WITH ALL
INSTRUCTIONS BELOW.
THIS MANUAL SHOULD BE KEPT WITH THE EQUIPMENT AT ALL TIMES.
1.Themajorhazardinvolvedwithinstallingandoperatingtheunitiselectricalshock.
Thishazardcanbeavoidedifyouadheretotheproceduresinthismanualandexercise
allduecare.
2.Installationanduseofthisproductshouldonlybecarriedoutbyproperlytrainedand
approvedpersonnel.
3.PleaserefertostoragemediaMSDSwhichshouldbesuppliedbytheproprietorofthis
systemwhichwilldetailthePPErequiredforhandlingandemergencyprocedures.
4.Theuserofthisproductisresponsibleforthesafeandcorrectuseofthisproduct.
5.Thisproductisonlysuitableforstorageand/ordispensingoftheliquidmediarefer-
encedatthepointofsale.
3. SAFETY

4
4. Product description
TuaAdBlue®StationsaredesignedsolelyforstorageanddispensingofAdBlue®.
ThestaticbundedsystemsenablesafeAdBlue®storageanddispensinginanoutdoor
environment.Thehighstandardofspecicationensuresoptimumsafetyandfunctionality.
Thisproduct’sstandardspecicationisnotapprovedfortheresaleofAdBlue®.
4.1 Productidentication
Theidenticationplateislocatedwithinthecabinetofeachsystemandwilldetailthe
capacity,serialnumber,modelnumberandyearofmanufacture.
4. PRODUCT DESCRIPTION

5
4.2Productspecication
1350SLBFS
AdBlue®
2500HBFS
AdBlue®
3500VBFS
AdBlue®
6000VBFS
AdBlue®
10000VBFS
AdBlue®
15000VBFS
AdBlue®
Capacity 1350litres 2500litres 3500litres 6000litres 10000litres 15000litres
Length 2680mm 2840mm - - - -
Width 870mm 1520mm - - - -
Diameter - - 2034mm 2580mm 2890mm 2860mm
Height 1665mm 1630mm 2520mm 2610mm 2600mm 3500mm
Cabinet depth - - 600mm 600mm 600mm 600mm
Weight (approx.) 220kgs 300kgs 350kgs 430kgs 500kgs 700kgs
Bund material LowerLinearDensityPolyethylene
Inner tank
material LowerLinearDensityPolyethylene
Description BundedAdBlue®FuelStation
Fill point 2”stainlesssteeldrybreakcoupling
Voltage 230V
Ventilation 2x2”screenedvents
Flow rate 40lpm(approximately)
Flowmeter Digitalbatteryoperatedturbinemeter(accuracy+/-1%)
Delivery hose 6 metres
Hose reel
(optional) N/A Hosereelavailable
8 metres - 19mm bore
Nozzle Automaticshutonozzle
4.PRODUCT DESCRIPTION

6
4.3 Product footprint
1350SLBFS AdBlue®
2500HBFS AdBlue®
4. PRODUCT DESCRIPTION

7
3500VBFS AdBlue®
6000VBFS AdBlue®
4.PRODUCT DESCRIPTION

8
10000VBFS AdBlue®
15000VBFS AdBlue®
4. PRODUCT DESCRIPTION

9
5. TRANSPORT & STORAGE
5. Transport & storage
DO NOT TRANSPORT WITH LIQUID INSIDE THE TANK
1. Duringtransportationtheiplidandcabinetdoorsaresecuredby1xRclip.TheR
clipmustbeinstalledpriortotransportation.
2. Loadingando-loadingmustbecarriedoutbyacompetentpersonusingsuitable
ratedandmaintainedequipment,eitheraforkliftwithextendedforks/tinesoracrane.Iflifting
slingsareused,theymustbeattachedtotheliftingpointsasshowninthepicturesbelow
usingasteelliftingeyeinsert.Ifliftingfrombelowuseasuitableratedforkliftwithextended
forks.Ifliftingfromaboveuseasuitableratingliftingslings/chains.
3. 1350SLBFSAD/2500HBFSAD-Liftwithmainliftingeyehighlightedinredinthe
imagebeloworforkliftfromtheside.
4. 3500VBFSAD/6000VBFSAD/10000VBFSAD/15000VBFSAD-Liftwithx4equal
spacedliftingbracketsashighlightedinredintheimagebeloworforkliftfromonesideusing
aratchetstraptosecurethetanktotheforkliftmast.
5. TuaAdBlue®Stationsmustneverbepushedorrolled.
6. Duringtransportandstorage,theiplidorcabinetdoorsmustbeclosedandsecured.
7. Loading,transportandstorageareasmustbesmoothandfreeofsharpedges.

10
6. Installation & commissioning
6.1 Installation guidelines
TheproprietoroftheTuaAdBlue®Stationisresponsibleforcomplyingwithalllegalrequire-
mentsrelatingtotheinstallationanduseofthisproduct,aswellastheguidelinesissuedby
localreghtingauthoritiesandenvironmentalauthorities.
OncetheTuaAdBlue®Stationhasbeenreceivedonsite,checkthatnodamagehasoc-
curredwhileintransit.Locatethetankinthedesiredlocationusingeithercrane,forkliftor
rollers.
6.2 System installation
System foundation
Thesystemmustbeinstalledandfullysupportedonasmoothlevelledconcretebasebuiltin
accordancewithgoodbuildingstandardsandengineeringprinciples.Itisrecommendedthat
tanksbeinstalledonaconcretebaseatleast100mmthick.Pleaserefertodiagrambelow:
6.3 System location
Thelocationofthesystemshouldbepositionedbyaroadorpassingwithsucientwidth,
andloadingcapacitytoaccommodateatankerdeliveringAdBlue®.ProvisionfortheU-turnof
atankershouldbeconsidered.Potentialobstaclesintheformoftreebranches,highvoltage
lines,orparkedvehiclesmustbeminimized.
Thespacearoundthesystemshouldallowfreeandcollision-freemovementofservedvehi-
cles.
Provisionshouldbemadetoprotecttankfromimpactdamage.
6. INSTALLATION & COMMISSIONING

11
6.4 Electrical requirements
Onlyasuitablyqualiedelectricianaccordingtoapplicableregulationsmayworkontheelec-
tricwiringinstallation.Thesystemcomponentsunderservice,maintenance,andrepairwork
mustbedisconnectedfromthepowersupplybeforeanyworkinundertaken.
System power requirements:
• 220-240Volts,50Hz+/-10%
• 20ampcircuitbreakerrecommended
• Powercablerecommendation:3Core2.5mmexcable
6.5 Electrical wiring diagram
6.5.11350SLBFSAdBlue®/2500HBFSAdBlue®–KeySwitch
6. INSTALLATION & COMMISSIONING

12
6.5.2 3500VBFSAdBlue®/6000VBFSAdBlue®/10000VBFSAdBlue®/
15000VBFSAdBlue®–KeySwitch
6. INSTALLATION & COMMISSIONING

13
7. Operation of the system
ThesystemanditscomponentsareintendedforAdBlue®onlyandforthepurposesde-
scribedbelow.Useofthissysteminameansotherthandescribedbelowisregardedas
mis-useofthesystem,theuserofthesystemwillbeliableforanydefectsthatoccurdueto
its unintended use.
7.1 Using the system
Theoperationandmaintenancepersonnelmustbesuitablytrainedtousethesystem,the
usermustmakesuretheyfullyunderstandtheoperationandmaintenancesectionsofthis
manual.
7.2 Summary of main parts 1350 / 2500
7. OPERATION OF THE SYSTEM

14
7.3 Summary of main parts 3500 / 6000 / 10000 / 15000
7. OPERATION OF THE SYSTEM

15
7.4 Filling AdBlue® Station
1. Fillingshouldbeperformedonlyunderconstantsupervisionofanauthorisedperson.
2. Thistankcanonlybelledbyatankerequippedwitha2”femaledrybreakcoupling.
3. On3500/6000/10000/15000modelsbeforellingthetankwithAdBlue®,please
checkthelevelofthetankandmakenoteofthetanklevelbeforellingandensurethe
highlevelalarmindicatorfunctionscorrectly.
4. Fittankerdeliveryhoseto2”drybreakllcouplingontank.
5. Engagetankerpumpandbegintoll.Stopllingwhendesiredamounthasbeen
dispensedintotank,orwhenhigh-levelalarmsounds.
6. Duringthetankerllalwaysobservetanklevelgaugethroughoutthedurationofthe
llingprocess.Thetankerdrivermustobservethetankbeinglledatalltimesduringthis
process.
7. Oncecompletedisconnectdeliveryhosefromtankcoupling.
7.5 Dispensing AdBlue® into vehicle
1. Resettheowmetertotalizerto0
2. Activatepumpusingoneofthefollowing:Rockerswitch,keyswitch,auto-operational
nozzleholster
3. RemovenozzlefromnozzleholsterandinsertthenozzlecompletelyintotheAdBlue®
tankllerneck
4. PulltriggeronthenozzletoallowAdBlue®toowintothevehicleAdBlue®tank
5. Atthistimetheowmetercounterwillstartrecordingtheow,continuerefuelinguntil
thedesiredamountisreachedorwhenthevehicleAdBlue®tankisfull
6. WhentheAdBlue®isfullthenozzlewillautomaticallyswitcho
7. Releasethetriggerofthenozzleandreplacebackintotheholster
8. Deactivatepumpwithrockerswitch/keyswitch/autooperationalnozzleholster
7. OPERATION OF THE SYSTEM

16
7.6 EQUIPMENT COMPONENTS
7.6.1 FMS GAUGE LEVEL (3500 | 6000 | 10000 | 15000)
TheFuelLevelMonitoringSystemisa240vcombineddigitaltank
levelindicatorandbundandhigh-levelalarmthatisdesignedto
providebothvisualandaudiblealarmswheneverapredetermined
levelinastoragetankisreached.TheFMSgivesacontent
readoutinbothlitresandapercentage.
A. FULL ALARM
Activationofthisalarmindicatesthatthetankisfull.Thisalarmis
shownthroughvisualLED’sandaudiblesiren.Note:Thisaudible
andvisualalarmwillremaintriggeredforashortperiodoftime
afteritsounds.Theaudiblecanbemutedusingthemutebutton
onthekeypad.THEPUMPWILLCONTINUETODISPENSEIN
THISALARMMODE.
B. HIGH LEVEL ALARM
Activationofthisalarmindicatesthetankhasreachedahigh
capacityandcloseattentionmustbepaidtothedieselinside
thetank.ThisalarmisshownthroughvisualLED’sandaudible
siren.Note:Thisaudibleandvisualalarmwillremaintriggered
forashortperiodoftimeafteritsounds.Theaudiblecanbe
mutedusingthemutebuttononthekeypad.THEPUMPWILL
CONTINUETODISPENSEINTHISALARMMODE.
C. LOW LEVEL ALARM
Activationofthisalarmindicatesthetankhasreachedalow
level.ThisalarmisshownthroughvisualLED’sandaudiblesiren.
Note:Thisaudibleandvisualalarmwillremaintriggeredfora
shortperiodoftimeafteritsounds.Theaudiblecanbemutedus-
ingthemutebuttononthekeypad.THEPUMPWILLCONTINUE
TODISPENSEINTHISALARMMODE.
D. EMPTY ALARM
Activationofthisalarmindicatesthetankisemptyandneeds
lling.ThisalarmisshownthroughvisualLED’sandaudiblesiren.
Note:Thisaudibleandvisualalarmwillremaintriggeredfora
shortperiodoftimeafteritsounds.Theaudiblecanbemutedus-
ingthemutebuttononthekeypad.THEPUMPWILLCONTINUE
TODISPENSEINTHISALARMMODE.
E. BUND ALARM
Activationofthisalarmindicatesthatthereisproductinthebund
cavity.ThisalarmisshownthroughvisualLED’sandaudible
siren.Note:Thisaudibleandvisualalarmwillremaintriggered
constantlyuntilmutedoruntiltheproductisremoved.Theaudible
canbemutedusingthemutebuttononthekeypad.Intheeventof
thisitisadvisedthebundcavityischeckedanddrainedassoon
aspracticable.
F. FMS WIRING DIAGRAM
7. OPERATION OF THE SYSTEM

17
7.6.2 NOZZLE & INTEGRATED FLOWMETER (1350 | 2500)
A. INSTALLATION
Theautomaticnozzlesaresuppliedreadyforuse.
ThenozzlefeaturesaSWIVELhose-endtting(completewithO-ring)
usefulforconnectingtothesupplyhose.
TOENSUREPERFECTOPERATION,THEDEVICEMUSTBEUSED
TODISPENSEFLUIDSWITHCHARACTERISTICSFALLINGWITHIN
THEFOLLOWINGPARAMETERS:
-Qmin.:15l/min-Qmax:45l/min
-Pmin.:1,5bar-Pmax:3,5bar
Attention
During installation, use adequate sealants, being careful no residues
remain inside the hose.
Soasnottonegativelyaectproductoperation,couplethehose-end
ttingwiththehosewithoutusingtoolssuchaspliers,etc
Assemblywillbeeasieriftheswivelhose-endttingisalreadyttedon
thenozzle.
Makesurethehosesandthesuctiontankarewithoutthreadingscaleor
residueswhichcoulddamagethenozzleandtheaccessories
Warning
Apply adequate sealants on the male threads of the connections and
swivels
DonotuseTeontape
B. USE MODALITY
B1. MECHANICAL CHARACTERISTICS
Themainfeatureofthesenozzlesisthattheyareeasytouse.
Twooperatingmodesareavailable:
1 - Assisted Mode
Dispensebyoperatingthenozzlelever.Tointerruptdispensingmanually,
releasethelever.
2 - Automatic Mode
Usetheopeningleverlockdeviceforautomaticdispensing.
Tocontinuedispensingafterautomaticstop,thelevermustbefully
releasedbeforeproceedingtooperateitagain.
Tointerruptdispensinginmanualmode,presstheleveragain,thereby
releasingthedevice,andthenrelease.
Attention
DO NOT USE THE NOZZLE OUTSIDE THE PARAMETERS INDICATED
ON THE ”TECHNICAL SPECIFICATIONS” CHART
Dispensingisautomaticallyinterruptedthankstotheshut-o
device, which operates when the level of the liquid reaches the end
of the spout.
B2. ELECTRONIC CHARACTERISTICS
Attention
Theusercanchoosebetweentwodierentoperatingmodes:
1 - Normal Mode
ModewithdisplayofPartialandTotaldispensedquantities
2 - Flow rate Mode
ModewithdisplayofFlowRate,aswellasPartialdispensedquantity.
Note:Themeterfeaturesanon-volatilememoryforstoringthedispensing
data,evenintheeventofacompletepowerbreakforlongperiods.The
measurementelectronicsandtheLCDdisplayarettedinthetoppart
ofthemeterwhichremainsisolatedfromtheuidbythemeasurement
chamberandsealedfromtheoutsidebymeansofacover.
C. MISFILLING
Premise
ModewithdisplayofPartialandTotaldispensedquantities
Operation
The“magnetswitch”isamagneticeldwithinthellernecksofthe
nozzle.Thisopensthemagnetswitchinthespout,soitisonlypossibleto
dispensefromthetankwherethemagnetadaptorisinstalled.
Attention
Nozzlesequippedwith“magnetswitch”workonlyincombinationwith
the“magnetadapter”.The“magnetadapter”isanoptiontobebought
separately.
D. PRELIMINARY CHECK
Warning
Checkthecorrectoperationofthelockdevice,accordingtothefollowing
procedure:
1.Takeagraduatedreceptaclewithacapacityof20
litres(5gal)
2.Begindispensingintothereceptacle,setting
theleverintheminimumowposition,untilthe
receptacleisfull.
3.Keepingtheleveropen,makesurethespoutis
submergedbyabout5cm(2inches).
4.Thenozzlemuststop,withaclickofthelever
5.Repeatthesameoperationswiththeleverin
medium-owand
maximum-owposition.Checkthecorrectoperation
ofthestopdeviceasdescribedabove.
6.Ifthenozzlestopsduringdispensing,checkand
reducetheow.
7.Iftheshut-odevicedoesnotbegintooperate,
checktheminimumowrateofthesystemor
replacethenozzle.
E. INITIAL START UP
Onlystartdispensingaftermakingsurethatassemblyandinstallationhave
beencorrectlyperformed.
Attention
Itisgoodpracticetoonlyoperatethenozzleleveraftermakingsurethe
spouthasbeenproperlyinsertedinthemouthofthetanktobelled.
Note
Whenusingforthersttimeandeverytimethenozzleisused,following
theconnectionofthesupplyhose,gentlyoperatethelevertoenabletheair
toescapefromthecircuit,untilnormaloperationisachieved.
Attention
Checkthecorrectoperationoftheautomaticstopdeviceoncethetankis
full.
THE FAULTY OPERATION OF THIS DEVICE COULD CAUSE THE
SPILL OF LIQUIDS THAT ARE HAZARDOUS FOR PEOPLE AND THE
ENVIRONMENT.
F. WHAT IT LOOKS LIKE
The“LCD”oftheMETERfeaturestwonumericalregistersandvarious
indicationsdisplayedtotheuseronlywhentheapplicablefunctionso
requires.
1.Partialregister(5gureswithmovingcommaFROM0.1to99999)
indicatingthevolumedispensedsincetheresetbuttonwaslastpressed
2.Indicationofbatterycharge
3.Indicationofcalibrationmode
4.Totalsregister(6gureswithmovingcommaFROM0.1to999999),that
canindicatetwotypesofTotal:
7. OPERATION OF THE SYSTEM

18
7. OPERATION OF THE SYSTEM
1.GeneralTotalthatcannotbereset(TOTAL)
2.Resettabletotal(ResetTOTAL)
5.Indicationoftotalmultiplicationfactor(x10/x100)
6.Indicationoftypeoftotal,(TOTAL/ResetTOTAL);
7.IndicationofunitofmeasurementofTotals:
L=LitresGal=Gallons
8.IndicationofFlowRatemode
9.IndicationofunitofmeasurementofPartial:
Qts=QuartsPts=Pints
L=LitresGal=Gallons
F1. USER BUTTONS
TheMETERfeaturestwobuttons(RESETandCAL)whichindividually
performtwo
mainfunctionsand,together,othersecondaryfunctions.
Main functions performed
-fortheRESETkey,resettingthepartialregisterandResetTotal
-fortheCALkey,enteringinstrumentcalibrationmode
Secondary functions
Usedtogether,thetwokeyspermitenteringcongurationmodewhere
thedesiredunitofmeasurementcanbeset.
Legend
CALIBRATEMEANSPERFORMINGACTIONSONTHEMETERKEYS.
BELOWISTHELEGENDOFTHESYMBOLSUSEDTODESCRIBE
THEACTIONSTOBEPERFORMED
F2. BATTERY HOUSING
K24ispoweredbytwo1.5Vstandardtypebatteries(sizeAAA).The
batteryhousingiseasilyaccessibleandisclosedbyacoverwithseal.
Everythingiseasilyremovablebytakingotherubberprotectionaround
thenozzleandlooseningthescrewswhichsecurethecover.
G. DAILY USE
Theonlyoperationsthatneedtobedonefordailyusearepartialand/
orresettabletotalregisterresetting.Theusershoulduseonlythe
dispensingsystemofK24.Occasionallythemetermayneedtobe
conguredorcalibrated.Todoso,pleaserefertotherelevantchapters
Belowarethetwotypicalnormaloperationdisplays.Onedisplaypage
showsthepartialandresettotalregisters.Theothershowsthepartial
andgeneraltotal.Switchoverfromresettabletotaltogeneraltotal
displayisautomaticandtiedtophasesandtimesthatareinfactoryset
andcannotbechanged.
Note:
6digitsareavailableforTotals,plustwoiconsx10/x100.The
incrementsequenceisthefollowing:
0.0->99999.9->999999->100000x10->999999x10->100000x
100->999999x100
G1. DISPENSING IN NORMAL MODE
Normalmodeisthestandarddispensing.Whilethecountismade,the
partialandresettabletotalaredisplayedatthesametime(resettotal).
Warning: Shouldoneofthekeysbeaccidentallypressedduring
dispensing,thiswillhavenoeect.
Standby
Afewsecondsafterdispensinghasended,onthelowerregister,the
displayswitchesfromresettabletotaltogeneraltotal:thewordreset
abovethewordtotaldisappears,andtheresettotalisreplacedbythe
generaltotal.Thissituationiscalledstandbyandremainsstableuntilthe
useroperatestheK24again.
G1.1 PARTIAL RESET (NORMAL MODE)
Thepartialregistercanberesetbypressingthe
resetkeywhenthemeterisinstandby,meaning
whenthedisplayscreenshowstheword“TOTAL”.
Afterpressingtheresetkey,duringreset,the
displayscreenrstofallshowsallthelit-updigits
andthenallthedigitsthatarenotlitup.
Attheendoftheprocess,adisplaypageisrstof
allshownwiththeresetpartialandtheresettotal
and,afterafewmoments,theresettotalis
replacedbythenonresettableTotal.
G1.2 RESETTING THE RESET TOTAL
Theresettotalresettingoperationcanonlybe
performedafterresettingthepartialregister.The
resettotalcaninfactberesetbypressingthereset
keyatlengthwhilethedisplayscreenshowsreset
totalasonthefollowingdisplaypage:
Schematically,thestepstobetakenare:
1.Waitforthedisplaytoshownormalstandby
displaypage(withtotalonlydisplayed)
2.Presstheresetkeyquickly
3.Themeterstartstoresetthepartial
4.Whilethedisplaypageshowingtheresettotalis
displayed
Presstheresetkeyagainforatleast1second
5.Thedisplayscreenagainshowsallthesegments
ofthedisplayfollowedbyalltheswitched-o
segmentsandnallyshowsthedisplaypagewhere
theresetResetTotalisshown.
G2. DISPENSING WITH FLOW RATE MODE
DISPLAY
Itispossibletodispenseuid,displayingatthesame
time:
1.Thedispensedpartial
2.TheFlowRatein[PartialUnit/minute]asshownon
thefollowingdisplaypage:
Procedure for entering this mode:
1.WaitfortheRemoteDisplaytogotoStandby,meaningthedisplay
screenshowsTotalonly
2.QuicklypresstheCALkey.
3.Startdispensing
Theowrateisupdatedevery0.7seconds.Consequently,thedisplay
couldberelativelyunstableatlowerowrates.Thehighertheowrate,
themorestablethedisplayedvalue.
ATTENTION
Theowrateismeasuredwithreferencetotheunitofmeasurementof
thePartial.Forthisreason,incaseoftheunitofmeasurementofthe
PartialandTotalbeingdierent,asintheexampleshownbelow,it
shouldberememberedthattheindicatedowraterelatestotheunit
ofmeasurementofthepartial.Intheexampleshown,theowrateis
expressedinQts/min.
Theword“Gal”remainingalongsidetheowratereferstotheregisterof
Other manuals for AdBlue 1350SLBFSAD
1
This manual suits for next models
5
Table of contents
Other TUFFA TANKS Storage manuals
Popular Storage manuals by other brands

Ezquest
Ezquest B16568 Specifications

Ingeteam
Ingeteam INGECON SUN STORAGE 1Play Installation and operation manual

SGS
SGS STC10T owner's manual

Qsan Technology
Qsan Technology XN8008R owner's manual

Brocade Communications Systems
Brocade Communications Systems 1606 Reference

Western Digital
Western Digital My Passport WDML2500 Specifications