turck TX707FB-P3CV01 User manual

TX707FB-P3CV01
© Hans Turck GmbH & Co. KG | 1000015593 2020-11 DE EN FR
Technical Data/Certication Data
Device
Type TX707FB-P3CV01
Ident-No. 100007471
Power Supply
Supply voltage 24 VDC (10 to 32 VDC)
Current consumption Max. 0.7 A at 24 VDC
System resources
CPU ARM Cortex-A9, dual core, 800 MHz
Operating System Linux RT
Flash 4 GB
RAM 1 GB
Real Time Clock, RTC Back-up,
Buzzer
Yes
Interface
Ethernet ports 3
Transmission rate Port 0: 10/100/1000 Mbps
Port 1 and 2: 10/100 Mbps
USB ports 2 2 (Host V. 2.0, max. 500 mA)
Serial port 1
RS232, RS485, RS422, software configurable
Max. 3 serial ports using plug-in modules.
SD card Yes
Expansion 2 slots for max. 4 plug-in modules
General Information
Operating temperature -20 °C…+60 °C (vertical installation)
Plug-in modules and USB devices may limit the max.
temperature to +50 °C
Storage temperature -20 °C…+70 °C
Relative humidity 5…85 % RH, non condensing
Protection class IP69 (front), IP20 (rear)
Dimenstions
Housing (W × H) 217 × 177 mm
Installation cut-out (W × H) 176 × 136 mm
Installation depth (D) 45 + 10 mm
Weight 2.5 kg
Approvals
For installation in industrial environments:
- emission EN 61000-6-3, EN 61000-6-4
- immunity EN 61000-6-1, EN 61000-6-2
UL cULus (UL File No. E484727)
- UL 61010-1, 3rd Edition and UL 61010-2-201, 1st Edition
- CAN/CSA C22.2 No. 61010-1, 3rd Edition and
CAN/CSA C22.2 No. 61010-2-201:14

TX707FB-P3CV01
HMI – TX707FB-P3CV01
Weitere Unterlagen
Ergänzend zu diesem Dokument finden Sie im Internet unter www.turck.com
folgende Unterlagen:
■Datenblatt
■Betriebsanleitungen zur TX…-Serie
■EU-Konformitätserklärung (aktuelle Version)
Zu Ihrer Sicherheit
Bestimmungsgemäße Verwendung
Die HMIs (Human Machine Interfaces) der TX700-Familie dienen zum Steuern,
Bedienen und Beobachten von Maschinenprozessen. Die HMI/PLC-Bediengeräte
der F&B-Serie sind für den Einsatz im Lebensmittelbereich geegnet und entspre-
chen den Normen und Richtlinien für hygienisches Design DIN EN1672-2 sowie
EHEDG/FDA 21 CFR 177.2006.
Die Geräte dürfen nur wie in dieser Anleitung beschrieben verwendet werden.
Jede andere Verwendung gilt als nicht bestimmungsgemäß. Für daraus resultie-
rende Schäden übernimmt Turck keine Haftung.
Allgemeine Sicherheitshinweise
■Nur fachlich geschultes Personal darf das Gerät montieren, installieren, betrei-
ben, parametrieren, programmieren und instand halten.
■Die Geräte erfüllen ausschließlich die EMV-Anforderungen für den industriel-
len Bereich und sind nicht zum Einsatz in Wohngebieten geeignet.
■Die Geräte nur in Übereinstimmung mit den geltenden nationalen und inter-
nationalen Bestimmungen, Normen und Gesetzen einsetzen.
■Geräte nicht unter Spannung öffnen.
Produktbeschreibung
Geräteübersicht
Siehe Abb. 1
Funktionen und Betriebsarten
Die Geräte der TX700-Familie kombinieren die Funktionen„Steuern, Bedienen
und Beobachten“ durch eine CODESYS V3-SPS mit integrierter Visualisierung zu
einer vollwertigen Steuerungseinheit. Die CODESYS-V3-Steuerung der TX700-
Geräte verfügt über die Funktionen PROFINET-Controller, EtherNet/IP-Scanner
und Modbus TCP- sowie Modbus RTU-Master. Darüber hinaus können die
Geräte der TX700-Familie als Modbus TCP- sowie Modbus RTU-Slave verwendet
werden.
Weitere Funktionen
■Ethernet TCP/IP- oder UDP/IP-Kommunikation
■OPC-UA-Server und -Client, MQTT
■Serielle Kommunikation über RS232, RS485 und RS422
Montieren
Siehe Abb. 2 und 3
A = TX7…
B = Einbauausschnitt
➤ Jede der Schrauben anziehen, bis die Ecken des Rahmens auf dem Panel
aufliegen. Das maximale Anzugsdrehmoment beträgt 1,3 Nm.
➤ Lüftungsschlitze im Gerät nicht verdecken.
TX… Halterungen im Lieferumfang
TX707FB 4
Anschließen
Anschlüsse und Steckplätze
Siehe Abb. 4
Anschluss/Steckplatz Funktion
1 USB-Port V2.0, max. 500 mA (nur für Wartung)
2 Ethernet-Port 2 (10/100 Mbit)
3 Ethernet-Port 1 (10/100 Mbit)
4 Serieller Port
5 Ethernet-Port 0 (10/100/1000 Mbit)
6 Spannungsversorgung
7 SD-Karten-Steckplatz
8 2 Erweiterungssteckplätze für Plug-in-Module
HINWEIS
Geräte der Schutzklasse III nach EN 61140 bzw. Class 2 nach UL-Standard:
Alle Anschlüsse sind SELV-Anschlüsse.
Spannungsversorgung
➤ Gerät gemäß Abb. 5 und 6 an die Versorgungsspannung anschließen.
GEFAHR
Falsche Wahl der Spannungsversorgung
Lebensgefahr durch Überspannung und Stromschlag!
➤Geräte nur an SELV-Spannungsquellen betreiben.
Gerät erden
Der minimale Leitungsquerschnitt für den Erdungsanschluss beträgt 1,5 mm².
➤ Gehäuse über die Erdungsschraube auf der Gehäuserückseite erden.
➤ Gerät über Klemme 3 am Spannungsversorgungsanschluss erden.
Serielle Schnittstelle
Siehe Abb. 7
Pin RS232 RS422/RS485
1 RxD CHB-
2TxD CHA-
3CTS CHB+
4RTS CHA+
5+5 VDC Ausgang +5 VDC Ausgang
6 GND GND
7 n. c. n. c.
8 Schirm Schirm
HINWEIS
Bei Nutzung als RS485-Schnittstelle müssen Pin 1 und 2 sowie Pin 3 und 4
extern verbunden werden.
Instand halten
➤ Gerät in regelmäßigen Abständen mit einem feuchten Tuch reinigen.
Reparieren
Das Gerät ist nicht zur Reparatur durch den Benutzer vorgesehen. Sollte das
Gerät defekt sein, nehmen Sie es außer Betrieb. Bei Rücksendung an Turck
beachten Sie bitte unsere Rücknahmebedingungen.
Entsorgen
Das Gerät ist mit einer wiederaufladbaren Lithium-Batterie ausgestattet, die
nicht zum Austausch durch den Benutzer vorgesehen ist.
➤ Zur Entsorgung, Rückseite des Geräts öffnen und Batterie entfernen.
Das Gerät und die Lithium-Batterie müssen fachgerecht gemäß WEEE-
Richtlinie 2012/19/EU entsorgt werden und gehören nicht in den
normalen Hausmüll.
DE Kurzbetriebsanleitung
Hans Turck GmbH & Co. KG | Witzlebenstraße 7, 45472 Mülheim an der Ruhr, Germany | Tel. +49 208 4952-0 | Fax +49 208 4952-264 | [email protected] | www.turck.com

TX707FB-P3CV01
HMI – TX707FB-P3CV01
Other documents
The following additional documents are available online at www.turck.com
■Data sheet
■Instructions for use for TX series
■EU declaration of conformity (current version)
For your safety
Intended use
The HMIs (Human Machine Interfaces) of the TX700 family are used to control,
operate and monitor machine processes.
The HMI/PLC operator panels of the F&B series are suitable for use in the F&B
industry and comply with the standards and guidelines for hygienic design
DIN EN1672-2 and EHEDG/FDA 21 CFR 177.2006.
The devices may only be used as described in this manual. Any other use is not
in accordance with the intended use. Turck accepts no liability for any resulting
damage.
General safety instructions
■The device may only be assembled, installed, operated, parameterized and
maintained by professionally-trained personnel.
■The device only meets the EMC requirements for industrial areas and is not
suitable for use in residential areas.
■The devices may only be used in accordance with applicable national and
international regulations, standards and laws.
■Do not open the devices under voltage.
Product description
Device overview
See fig. 1
Functions and operating modes
The devices of the TX700 series combine control, operation and monitoring
by a CODESYS V3 PLC with web visualization to a complete control unit. The
CODESYS V3 control of the TX700 devices has the functions PROFINET controller,
EtherNet/IP scanner and Modbus TCP as well as Modbus RTU master. Addi-
tionally the devices of the TX700 family can be used as Modbus TCP as well as
Modbus RTU slave.
Additional functions
■Ethernet TCP/IP or UDP/IP communication
■OPC-UA server and client, MQTT
■Serial communication via RS232, RS485 and RS422
Installing
See fig. 2 and 3
A = TX7…
B = installation cut-out
➤ Screw each fixing screw until the bezel corner gets in contact with the panel.
The maximum tightening torque is 1.3 Nm.
➤ Do not cover the ventilation slits in the device.
TX… Brackets included in delivery
TX707FB 4
Connecting
Connectors and slots
See fig. 4
Connector/slot Function
1 USB port , V2.0, max. 500 mA (for maintenance only)
2 Ethernet port 2 (10/100 Mbit)
3 Ethernet port 1 (10/100 Mbit)
4 Serial interface
5 Ethernet port 0 (10/100/1000 Mbit)
6 Power supply
7 SD card slot
8 2 expansion slots for plug-in modules
NOTE
Devices of protection class III according to EN 61140 or Class 2 according to UL
standards: All connections are SELV connections.
Power supply
➤ Connect the device to the voltage supply according to fig. 5 and 6.
DANGER
Wrong selection of power supply
Danger to life due to overvoltage and electric shock!
➤Only operate devices at SELV power supplies.
Grounding the device
The minimum conductor cross-section for the ground connection is 1.5 mm².
➤ Ground the housing via the grounding screw on the back of the housing.
➤ Connect terminal 3 on the power supply terminal block to ground.
Serial interface
See fig. 7
Pin RS232 RS422/RS485
1 RxD CHB-
2TxD CHA-
3CTS CHB+
4RTS CHA+
5+5 VDC output +5 VDC output
6 GND GND
7 n.c. n.c.
8 Shield Shield
NOTE
When used as RS485 interface, pins 1 and 2 as well as pins 3 and 4 must be
connected externally.
Maintenance
➤ Clean the devices at regular intervals with a damp cloth.
Repair
The device must not be repaired by the user. The device must be decommis-
sioned if it is faulty. Observe our return acceptance conditions when returning
the device to Turck.
Disposal
The device is equipped with a rechargeable lithium battery, which is not user
replaceable.
➤ For disposal, open the back of the device and remove the battery.
The device and the lithium battery must be disposed of properly in ac-
cordance with WEEE Directive 2012/19/EU and must not be included in
general household garbage.
EN Quick Start Guide
© Hans Turck GmbH & Co. KG | 1000015593 2020-11 DE EN FR

TX707FB-P3CV01
IHM – TX707FB-P3CV01
Documents supplémentaires
Sur www.turck.com vous trouverez les documents suivants, qui contiennent les
informations complémentaires à la présente notice:
■Fiche technique
■Notice d’utilisation série TX…
■Déclaration de conformité UE (version actuelle)
Pour votre sécurité
Utilisation conforme
Les IHM (interfaces homme-machine) de la famille TX700 sont utilisées pour la
commande, l'exploitation et la surveillance des processus machine.
Les panneaux de commande IHM/PLC de la série F&B sont conçus pour être
utilisés dans l'industrie alimentaire et sont conformes aux normes et directives
de conception hygiénique DIN EN1672-2 et EHEDG/FDA 21 CFR 177.2006.
Les appareils doivent être utilisés conformément aux indications du manuel.
Toute autre utilisation est considérée comme non conforme. La société Turck
décline toute responsabilité en cas de dommages causés par une utilisation non
conforme.
Consignes générales de sécurité
■Seul un personnel qualifié est habilité à monter, installer, utiliser, paramétrer,
programmer et entretenir l’appareil.
■Les appareils répondent exclusivement aux exigences de la directive CEM
pour le secteur industriel et ne sont pas destinés à être mis en œuvre dans les
zones d’habitation.
■Les appareils doivent uniquement être utilisés conformément aux disposi-
tions, normes et lois nationales et internationales en vigueur.
■Ne pas ouvrir les appareil sous tension.
Description du produit
Aperçu de l’appareil
Voir fig. 1
Fonctions et modes de fonctionnement
Les appareils de la famille TX700 combinent commande, gestion et monitoring
dans une offre complète grâce à une CODESYS V3 PLC avec une visualisation
web. La commande CODESYS V3 des appareils TX700 dispose des fonctions
contrôleur PROFINET, scanner EtherNet/ IP, maître Modbus TCP et maître
Modbus RTU. De plus, les appareils TX700 peuvent être utilisé comme esclave
Modbus TCP et Modbus RTU.
Fonctions supplémentaires
■Communication Ethernet TCP/IP ou UDP/IP
■Serveur et client OPC-UA, MQTT
■Communication sérielle via RS232, RS485 ou RS422
Montage
Voir fig. 2 at 3
A = TX7…
B = découpe de montage
➤ Serrer chacune des vis jusqu'à ce que la tête de celle-ci sera en contact avec
l‘afficheur. Le couple de serrage max. est 1.3 Nm.
➤ Ne pas couvrir les ouvertures de ventilation de l'appareil.
TX… Étriers de xation fournis
TX707FB 4
Raccordement
Connecteurs et emplacements
Voir fig. 4
Connecteur/emplacement Fonction
1 Port USB V2.0, max. 500 mA (pour la maintenance)
2 Port Ethernet 2 (10/100 Mbit)
3 Port Ethernet 1 (10/100 Mbit)
4 Port série
5 Port Ethernet 0 (10/100/1000 Mbit)
6 Alimentation
7 Emplacement SD
8 2 emplacements pour modules plug-in
NOTE
Appareils de la classe de protection III selon EN 61140 ou Classe 2 selon normes
UL: Toutes les connexions des sont connexions SELV (Extra Sécurité - tension
basse).
Alimentation
➤ Raccorder l'appareil à la tension d'alimentation comme indiqué sur les fig. 5
et 6.
DANGER
Mauvais choix d'alimentation électrique
Danger de mort par surtension et choc électrique !
➤Utiliser les appareils seulement avec alimentations SELV.
Mise à la terre de l'appareil
La section minimale du conducteur pour la mise à la terre est de 1,5 mm².
➤ Mettre le boîtier à la terre par la vis de mise à la terre située à l'arrière du
boîtier.
➤ Mettre l'appareil à la terre via la borne 3 du connecteur d'alimentation.
Port série
Voir fig. 7
Pin RS232 RS422/RS485
1 RxD CHB-
2TxD CHA-
3CTS CHB+
4RTS CHA+
5Sortie +5 VDC Sortie +5 VDC
6 GND GND
7 n. c. n. c.
8 Shield Shield
NOTE
En cas d'utilisation comme interface RS485, les broches 1 et 2 ainsi que les
broches 3 et 4 doivent être connectées en externe.
Maintenance
➤ Nettoyer l'appareil à intervalles réguliers avec un chiffon humide.
Réparation
L’appareil ne peut pas être réparé par l’utilisateur. En cas de dysfonctionnement,
mettez l’appareil hors tension. Veuillez tenir compte de nos conditions de
reprise lorsque vous souhaitez renvoyer l’appareil à Turck.
Mise au rebut
L'appareil est équipé d'une batterie au lithium rechargeable, qui n'est pas desti-
née à être remplacée par l'utilisateur.
➤ Pour la mise au rebut, ouvrir l'arrière de l'appareil et retirer la batterie.
L'appareil et la batterie au lithium doivent être éliminés correctement
conformément à la directive DEEE 2012/19/UE et ne doivent pas être
jetés avec les déchets ménagers normaux.
FR Mode d’emploi simplifié
Hans Turck GmbH & Co. KG | Witzlebenstraße 7, 45472 Mülheim an der Ruhr, Germany | Tel. +49 208 4952-0 | Fax +49 208 4952-264 | [email protected] | www.turck.com
This manual suits for next models
1
Table of contents
Languages:
Other turck Touch Panel manuals
Popular Touch Panel manuals by other brands

Avalue Technology
Avalue Technology EPD-42T Quick reference guide

Crestron
Crestron Isys TPS-5000 Field Service Guide

Novus
Novus N1500G operating manual

WIKA
WIKA CPH62I0-S1 operating instructions

BIG TREE TECH
BIG TREE TECH Raspberry pad 5 V1.0 instruction manual

Crestron
Crestron Isys TPS-3000 Connection guide