TUV JA-80L User manual

01 –10 - 2013 980108002-09-003
JA-80L wireless internal siren
The JA-80L is a component of OASiS
alarm system. The siren is mains-powered
and communicates via OASIS wireless
protocol. It can be used as an indoor alarm
siren, a sounder for entrance and exit delay
beeps and a detector-triggered chime. It also
sounds when an intruder alarm has been
triggered and confirms the actual presence of
an intruder in the buildingby sending a tamper
signalwhen it gets unplugged.
It can be used as a stand-alone device –as
awirelessdoorbellor forcallingforhelp.
In combination with asmoke or gas detector
it will set atwo minute warning alarmfor fire danger.
Enrolling theJA-80L to an OASiS control panel
1. Switch the control panel to service mode and key in 1 (to enter enrollment
mode).
2. Plug the siren into a mains socket. The JA-80L indicator will turn on and off
whichconfirms enrollment.
3. Exit enrollment mode bypressingthe #key on the system keypad.
Notes:
a) Severalsirens canbeenrolledto thecontrolpanelifdesired.
b) If the sirenfails to enroll (its indicator will not turn off),check:
Is thecontrolpanel in enrollment mode ?
Is thesiren set to factory default settings ?If not, reset the siren.
c) An enrolled siren generates a siren sound if an alarm is triggered in the
control panel, and can generate beeps for entrance and exit delays
(programmableinthecontrolpanel).
d) The siren can be simultaneously used as a wireless doorbell or a detector-
triggered chime. To do this the doorbell button and the relevant detectors
have to be enrolled to the siren (after the siren has been enrolled to the
control panel –seelater text).
e) If the siren gets unplugged from the mains while sounding an alarm, the
siren immediately sends a tamper signal to trigger a tamper alarm in the
controlpanel.
The siren’s radio signals can be checked and measured by the control panel
in service mode. Tomake thesiren transmit a test signal, pressits button.
Additional siren settings
The siren can acoustically signal setting the system (1 beep) and
unsetting the system (2 beeps). To enable this feature briefly press the siren’s
button three times (confirmed by two beeps). Use the same procedure to
disablethe feature(confirmedbyonebeep).
It is possible to go to other menu levels by holding the siren button (must be
plugged into the mains). When the button is released the state of the currently
chosen setting is changed. Each settable state is announced by a different
numberofbeeps.
1. hold for approx. 3s –to change the volume (doorbell melody, chirps), it has
no effect on the soundof alarms
2. hold for approx. 6s –beeps 1x –alarm restricted to PGX –thesiren sounds
when the control panelis in alarm state and thePGXoutput is active
3. hold for approx. 9s –beeps 2x –alarm restricted to PGY - the siren sounds
when the control panelis in alarm state and the PGY output is active
4. hold for approx. 12s –beeps3x–the LowBAT signalwillnot betransmitted
to thecontrol panel when the sirenis disconnectedfrom themains
5. holding the button longer will exit the setting and it will be confirmed by a
long and then ashort beep.
An alarm restricted tothe PGX or PGY outputs is suitable for a split system
wherePGX will be assigned to alarm A andPGY toalarm B.
Enrolling a doorbell button to the JA-80L siren.
Up to 8 wireless buttons of the type RC-86K can be enrolled to the siren as
follows:
1. Plug the sireninto a mains socket and if its indicator starts flashing, then
enrolling devices to the siren can begin. In this case, the siren still has
factory-default settings, i.e. no devices have been enrolled yet. If the
indicator is continuously lit after the siren is plugged in, then press and
hold it (while it is lit) until it starts flashing. This means that something
has already been previously enrolled and the mode being opened now
is foraddingmoredevices.
2. An RC-8x can be enrolled by activating it (pressing its button).
Successful enrollment is confirmed by a melody sound. By activating
the RC-8x repeatedly, you can scroll through the 8 possible melodies
whichcanbelinkedtoRC-8xactivation.
3. If all the desired RC-8x units have been enrolled, exit the siren’s
enrollment mode by pressing its button. This method allows the buttons
tobeaddedtothepreviouslyenrolleddevices
Detector-triggered chime mode
If it is desired to indicate the triggering of a wireless JA-8x detector by a chime
sound,thenenrollthe detectortothe sirenasfollows:
1. Plug the siren into a mains socket. If its indicator starts flashing, detector
enrollmentcan proceedimmediately (nopreviously enrolleddevices).
If however, the indicator lights continuously, press and hold the siren
button
(whileit is lit) untilit starts flashing (devicespreviously enrolled).
2. To enroll a detector, press and release its tamper switch. A sound is then
heard (by pressing and releasing the tamper switch you can scroll through
the 8possiblemelodiesforlinkingtothe detector).
3. After all the desired detectors have been enrolled, exit enrollment mode by
pressingthe sirenbutton.
In addition to chime sounds being activated by detector triggering, they can
also be activated by a JA-80F keypad’s IN input being triggered (to enroll a
keypad, pressand releaseits tamper switch).
Alarm siren forwireless fire detectors
If you want to use a JA-80L siren for transmitting an alarm from a wireless fire
detector (JA-80S and JA-80G), enroll the detectortothe siren as follows:
1. Insert thesireninto the wall socket. When it starts toflash you can enroll the
detector to it immediately (nodevice was previously enrolled tothe siren)
If the light lights constantly, press and hold the button till the light
starts to flash. (somedevices are alreadyenrolledtothe siren)
2. Enroll the detector by inserting batteries into the detector –the siren
will playthe sound of a doorbell
3. After you have enrolled all detectors press the siren‘s button to exit enrolling
mode.
4. When testing a detector by pressing the test button the siren plays a
melody. Never use an open fire to test the detector anywhere indoors. To
test using smoke use a special testing aerosol. The siren sounds when
testing usinga test aerosol.
NOTE: If you want to use a JA-80L siren to sound an alarm signal from
wireless detectors, the siren can’t be used with an OASiS control panel at the
sametime–it mustbe usedseparately.
Maximum number of enrolled devices
Up to 8 RC-86K units or detectors, and a single OASiS JA-80 control panel
can be enrolled to a single JA-80L siren. Each one of these things can be
enrolled to as manysirens or otherreceivers as desired.
Deleting all enrolled devices (RESET)
All enrolled devicescanbedeletedasfollows:
1. Unplug the siren from the mainssocket.
2. Press and holdthe siren button whileplugging in the sirenagain.
3. Keepthebutton pressed until two beeps are heard which confirm a reset.
4. Theindicatorkeepsflashing(deviceenrollmentmode).

01 –10 - 2013 980108002-09-003
5. To exitenrollment mode,press thesiren button(indicatorturns off).
If the indicator fails to flash after the two reset beeps, it means that the siren is
within radio range of the control panel to which it has been previously enrolled.
In such a case, all devices previously enrolled to the siren have been deleted
except for thecontrol panel. If you deliberately do not want to usethe siren with
the control panel anymore, it must first be deleted in the control panel before
resetting the siren (in control panel enrollment mode select the siren’s address
and press and hold key 2 on the system keypad to deletethe siren).
Indicator functions
In normal use, the indicator flashes when the doorbell button is pressed or
when the siren sounds. If the siren is enrolled to an OASiS control panel, then it
indicates the status of the programmable output PGY with a continuous light.
Theindicator flashes inenrollment mode.
Technical specifications
Powersupply 230V/50Hz,1W,class protectionII
Communication band 868MHz, OASiS protocol
Communication range approx.100m(openarea)
Sounds(melodies) 8selectableforbuttons anddetectors,
andan alarmsiren sound95dB/ 1m
Max.numberofenrolleddevices 1xOASiSJA-80controlpanel
8x OASiS wireless buttons and detectors
Safetyclass II accordingtoEN60950
Operatingenvironment general,indoor–10 to +40 °C
Housing IP40according to EN 60529
Mechanicalimmunity IK08according to EN 50102
Operatingconditions ERCREC 70-03
TheJA-80L complies with ETSI EN 300220,EN 50130-4, EN 55022 andEN60950-1
Table of contents