manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Tyro
  6. •
  7. Controllers
  8. •
  9. Tyro Fornax Basic User manual

Tyro Fornax Basic User manual

This manual suits for next models

1

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

Savant SmartControl 2 Deployment guide

Savant

Savant SmartControl 2 Deployment guide

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

Emerson Yarway 20-55 Operating and safety instructions

Emerson

Emerson Yarway 20-55 Operating and safety instructions

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Tyro Fornax Basic Forestry Winch Control
Manual, standard 868 MHz version
Tyro Remotes Tel: +31-(0)546-588790
Bedrijvenpark Twente 1B Fax: +31-(0)546-579490
7602 KA Almelo E-mail: [email protected]
Nederland Website: www.tyroremotes.eu
Functions of the transmitter:
Fornax Basic Fornax Basic - Safe
Wind up
Unwind / continuous (after the switch is pressed down for 3 seconds).
The continuous function is cancelled with the wind-up function.
In that case the wind-up function does not immediately become active, but only when pressed
again.
Transmitter on - Press the toggle switch in the direction of the symbol for 1 second.
Transmitter off - Press the toggle switch in the direction of the symbol for 1 second.
Active emergency call - Press the toggle switch in the direction of the symbol for 5 seconds.
The emergency call output can be reset by switching the transmitter back on.
Emergency stop, all the functions that are switched on will switch off.
The emergency stop button is only active as long as the transmitter is on.
Status LED on the transmitter
LED flashes green: Only during transmission.
LED flashes red: During transmission if the battery capacity falls below 10%.
LED briefly lights up red when switching on the transmitter:
A function button is active, there is an unsafe situation. Now the transmitter will not switch on.
Changing the battery
If the status LED onthe transmitter flashes red during transmission, the 9V battery must be replaced
within the next few days.
Tyro Fornax Basic Forestry Winch Control
Manual, standard 868 MHz version
Tyro Remotes Tel: +31-(0)546-588790
Bedrijvenpark Twente 1B Fax: +31-(0)546-579490
7602 KA Almelo E-mail: [email protected]
Nederland Website: www.tyroremotes.eu
Aquarius Basic receiver
Assembly
To optimise the system’s range, we recommend placing the Aquarius receiver as high as possible and
free of metal objects. After connection and assembly, please test firs before switching on the mains
power. Always connect the Aquarius receiver to the supply source after a main fuse.
Connection is as follows:
* Connect programming wire no. 7 to the earth
Status LED receiver Signal received: flashes yellow
Registration mode: continuously lit
For technical questions about assembly, please refer to www.tyroremotes.eu
Tab ‘Support’, Aquarius receiver, FAQs.
PLEASE NOTE: All the systems have already been programmed ex works
Programming a new Fornax transmitter to the receiver
If you want to program a new transmitter to the receiver, please do so as follows:
It is not possible to program more than 1 Fornax transmitter on the Aquarius Basic or Delta
receiver at the same time.
Description
Wire number
Wind up
3
Unwind
2
Emergency stop (Basic-Safe)
6
Emergency call
5
V+
1
Programming wire *
7
earth
yellow/green
Step
Description
1.
Make sure that the Aquarius receiver is connected correctly and has power.
2.
Switch off the Fornax transmitter.
3.
Connect wire no. 7 with the power supply (V+) for no longer than 3 sec. (If you connect wire
no. 7 for longer than 8 sec. the registration mode is rounded off again.)
4.
The status LED on the Aquarius receiver will now light up.
5.
Press the on/off switch on the Fornax transmitter in the direction of the green ‘on’ symbol.
6.
The status LED on the Aquarius receiver will now go out.
7.
The Fornax transmitter is now programmed to the Aquarius receiver.
8.
After programming, reconnect wire no. 7 back to the earth connection.
9.
After assembly, cut off and insulate all the unused wires.
Tyro Fornax Basic Forestry Winch Control
Manual, standard 868 MHz version
Tyro Remotes Tel: +31-(0)546-588790
Bedrijvenpark Twente 1B Fax: +31-(0)546-579490
7602 KA Almelo E-mail: [email protected]
Nederland Website: www.tyroremotes.eu
Technical specifications:
Aquarius Basic receiver:
Connection voltage
8 - 38 Vdc
Fuse
10 Amp fast glass fuse integrated (5 x 20 mm)
Power consumption
15 mA
Max. output Amperage
4A
IP classification
IP68
Size
150x90x30 (HxBxD)
Weight
480 g
Fornax Basic handheld transmitter:
Range in forest
100 to 200 metres
Operating frequency
868 MHz
Aerial
Integrated
Power consumption standby
2 µA.
Power consumption during transmission
4 mA (max.)
Low battery indication
If status LED flashes red during transmission
Battery type
1 battery, 9V 600 mAh alkaline (6LR61)
Operating battery
150 hours
Impact-resistance
Up to 2 metres
IP classification
IP65 (splashproof)
Size
150x115x58 (HxBxD)
Weight of standard version
445 g
Standard product delivery: Additional options available:
Fornax transmitter inc. 9V battey Aerial extension cable inc. connector
Aquarius Basic receiver 1 metres, 2 metres and 5 metres.
with 2.5 m of cable and 868 MHz aerial. 7-pole plug
140 cm belt.
All deliveries shall occur in accordance with the general terms and conditions of sale, which you can
request from us or download from the website. Our products are certified for many applications. During
assembly you should take into account the Machinery Directives that apply for your application.