1 Product overview
TZ-BT04 is Bluetooth Low Energy temperature and humidity data logger with the
latest Bluetooth 4.1 technology and Nordic NRF51822 chip. It can collect temperature
and humidity of the surrounding environment . Such data can be recorded as history
data. BT04 can store up to 12000 pieces of the temperature and humidity data. Mobile
phone with Bluetooth 4.0 or above can download and install App.It can store and
monitor temperature and humidity of the environment comprehensively. Its
characteristics are small-sized, low-weighted, easily portable and highly accurate for
wide use in cold chain logistics, archives, labs, museums, etc.

2 Product application
1. Refrigerated storage and transportation;
2. Archives;
3. Experimental (test) rooms;
4. Workshop;
5. Museums;
6. Pharmaceutical environment;
7. Fresh transport.
3 Product features
1. High accuracy and stability;
2. Bluetooth 4.1;
3. Long distance wireless transfer;
4. Built-in highly sensitive temperature and humidity sensor;
5. Real-time display temperature and humidity;
6. It can store 12000 pieces of temperature and humidity data;
7. You can set the alarm temperature range;
8. Can be set the scope of temperature alarm;
9. Can be set normal storage temperature and humidity data interval and alarm
storage temperature and humidity data interval;
10. Can choose time to query data, the stored data can be saved in history;
11. History report can be sent to specified email;
12. By pairing Bluetooth printer to print the data report;
13. Can by OTA update version.
4 Product specification
Item
Specification
Signal transmission frequency
2.400 - 2.4835GHz
Protocol standard
Bluetooth 4.1
Modulation mode
GFSK
Send interval
2S, adjustable
Built in battery
CR2450,620mAh /3V

Output power
-4dBm, adjustable
Communication rate
1Mbps
Transmission distance
55 meters, adjustable
Storage
Can be save 12000 temperature and humidity
data
battery life
1.5 years(Depends on the mode of operation,
can replace battery)
Net weight
30g
Outline size
50mm*50mm*16mm
Operating temperature range
-25℃~ +60℃
Operating Humidity range
0~85%RH
Temperature detection accuracy
±0.3℃(0~60℃),±0.3~0.7℃(other)
Humidity detection accuracy
±3%RH(20~80%),±4%(other)
5 Caution
1. Being close to a metal object will interfere with the signal, causing the signal to
be weaken.
2. Note the distance between TZ-BT04 and the receiver to guarantee the accuracy of
receiving.
3. Keep away from water and corrosive objects.
6 APP
‘Temp Logger’ is a free mobile applications which provided by our company to the
users, can connect the BT04 through the Bluetooth of the mobile devices and do the
settings,data transmission, recording, synchronization, send to email. Apply the
Bluetooth BLE way, so you can use Android phone for temperature monitoring.
Client can download App by scan the QR code below(V25 and above available):

6.1 Device Registration
6.1.1 Open the APP, enter the device ID directly to register on the homepage, or scan
the QR code to get the device ID, or do not enter any ID and directly click search to
find the device .
6.2.2 Enter the device connection page and click Connect. After a successful
connection, the device ID will be displayed on the "Devices" page, indicating that the
device has been registered successfully .

6.2 Device View
Click the icon in the upper left corner of the home screen to expand the main menu.
You can select the menu function and click “device” to enter the multidevice interface.
The functions of the device interface are as follow:

6.2.1 To view device information
The name, ID, MAC, temperature/humidity data, model, and status of all the current
devices can be viewed, or you can view the specific device information by ID, name,
and MAC.
Status description of the device in different symbols:
: Temperature normal
: Temperature alarm (including both high and low temperatures)
6.2.2 Delete the device:
Long press to delete the device:

6.2.3 Device alarm:
When the device exceeds the preset upper or lower limit, the alarm information will
be displayed, and the alarm bell will ring. Clicking "CLOSE " to turn off the alarm
information and alarm bell.

6.3 Device connection
Click a single device quickly to enter the connection interface. It will display the
temperature/humidity, voltage, RSSI, alarm status and logger status of the device.
Click "CONNECT," and jump to update after the connection is successful, indicating
that the device has been successfully connected and read the current data content.
After the connection is successful, it will prompt you whether to view the report, or
the access key and flight mode of the device will be displayed. Four buttons will be
displayed at the bottom of the interface:
Note: The device will not update the data in the connection process. By default, the
device will be disconnected after 1 minute and the four buttons at the bottom will
become gray and cannot be clicked again.
6.3.1 Device access key
Click "Access Key" to encrypt the device, and set the level-1 and level-2 access keys.
6.3.2 Detail and email function
Click "Detail" to view all information reports of the device. Click "EXPORT" to
generate PDF and CSV reports, and send the reports to the designated mailbox by
email.
A:Details summary

Note: The smartphone must have a mailbox APP and login account to send email.
B: Chart:

C: List:
6.4 Configure device
After connection, when the device does not start recording, you can click
"Configure" to set the device.

6.4.1 Device name: The device name can be modified (up to 7byte) by users.
6.4.2 Basic settings:
A: Transmission power: The device transmission power(range:-30dbm~4dbm,
default:-4dbm)
B: Logging interval: Record time of the stored data (range:10s~1h,
default:1mins).
C: Logging cycle : It changes with the logging interval.
6.4.3 Advanced settings
A: Access key: Must be enable,default: 000000.
6.4.4 Alarms:
A: Low temperature limit:-25℃
B: High temperature limit:100℃
6.4.5 Description: You can set a description for this device (up to 56 characters).
6.4.6 Start or stop
You can set whether the device starts or stops through the APP.
6.5 Data files
Click the "Data Files" menu bar to enter to the data files interface. The functions of
the device interface are as follows:

6.5.1 To View a single data file
The time displayed in this file is the time when the device data is read for the first
time. The information will be updated after each read until the machine stops
recording.
6.5.2 Chart report comparison supporting up to 5 files
Check the data file and click "Comparison" to compare the temperature chart
reports of different data files.
6.5.3 Delete data file
Check the data file and click "Delete" to delete the data file.
6.6 System setting
Click the "System setting" menu bar to enter the system setting interface. The
functions of the system setting interface are as follows:

7.6.1 Device Management:
1. Configuration file:You can view the configuration file saved in "Configure".
2. Remember the device access key:
Don’t turn on the switch: enter the access key every time you connect the device
Turn on the switch: when connection the device, you only need to input the
access key once (default: remember the key)
3. The firmware update:
Don’t turn on the switch: Firmware upgrades are not allowed
Turn on the switch: After connection, there is firmware upgrade function(default)
7.6.2 Time&Time zone Setting(Only for generating reports through the APP):
1. System default/Time Zone:
Don’t turn on the switch: is UTC time zone or another time zone as you choose
Turn on the switch:is the current time zone of the system (default: system
default)
2. Data Format: MM/DD/YY HH:MM:SS(default) or DD/MM/YY HH:MM:SS
7.6.3 Report settings(Only for generating reports through the APP):
1. Include Tabular Data in PDF: Select include or exclude (default: include).
2. Include Tabular Data in CSV: Select include or exclude (default: include).
Table of contents
Other Tzone Data Logger manuals
Popular Data Logger manuals by other brands

Capetti Elettronica
Capetti Elettronica WSD02T-T1K user manual

MadgeTech
MadgeTech QuadVoltV2 Product user guide

MadgeTech
MadgeTech RFCO2RHTemp2000A Product user guide

Keysight Technologies
Keysight Technologies DAQ970A Security guide

PCE Instruments
PCE Instruments PCE-AQD 10 user manual

NI
NI PCIe-1429 user manual