Ubisys H1 User manual

Heating Control H1
Manual

Revision 1.0 English, as of 10/2021
ubisys heating control H1, commissioning and operating instructions © 2021 ubisys technologies GmbH, Düs-
seldorf, Germany. All rights reserved. Reproduction and copies (also in extracts) only with the consent of ubisys
technologies GmbH.
We assume no liability for errors in content. Changes in the sense of technical progress can be made without
prior notice.

3Heating Control H1
Content
Content
Chapter 1 | General
1.1 Notes on this manual
1.2 Function and design of the H1
1.3 Technical details
Chapter 2 | Commissioning
2.1 Mounting
2.2 Initial commissioning (with and without
gateway)
2.3 Date and time setting
Chapter 3 | Set Room Temperature
3.1 How do I set the desired room
temperature?
3.2 Switch off the heating – and
switch on again
3.3 Set temperature offset
Chapter 4 | Schedules
4.1 What are schedules and how
do I create/change them?
4.2 How do I pause a schedule (vacation
mode)?
4.3 Delete all schedules
Chapter 5 | More Functions and In-
formation
5.1 Cancel operation/exit menu
5.2 Updates
5.3 Calibrate the H1
5.4 Changing the batteries
5.5 Finding/Binding
5.6 Unmounting
5.7 Factory reset
5.8 Overview of the symbols on the display
and their meaning
5.9 Maintenance
5.10 Disposal
5.11 Contact
4
5
5
7
8
9
9
13
15
16
18
19
20
21
27
28
29
30
30
30
31
32
34
35
37
41
41
42

4Heating Control H1
Chapter 1
General

5Heating Control H1
Chapter 1 | General
1.1 Notes on this manual
Read these instructions carefully before commissioning the H1 heating control. Keep the instructions for future
reference. The online version can be found at www.ubisys.de.
Images of the ubisys app
The illustrations in this manual correspond to the screens of the Apple iOS app (iPhone 11 Pro, iOS 13.7).
Depending on which app you are using, slight deviations with regard to display or operation are possible. This
applies to different iOS versions on an Apple iPad or devices with Google Android operating system.
1.2 Function and design of the H1
The H1 heating control is a smart, battery-powered radiator thermostat with integrated temperature sensor for
radiator heating systems and is used for efficient room temperature control in private and commercial facilities.
The H1 communicates wirelessly using the international radio standard Zigbee. Temperature control is perfor-
med manually on the device or via app (e.g. ubisys Smart Home App).
For operation via the ubisys Smart Home App, you need the ubisys Gateway G1. When using a Zigbee-capable
gateway from another manufacturer, a corresponding app must be used. The power supply is provided by two
lithium batteries (type AA with 1.5 V, Energizer L91, Ultimate Lithium – or comparable).
Note: If you want to control the H1 via the app of another manufacturer, you need a corresponding Zigbee-
capable gateway of this manufacturer. Deviations may then occur with regard to setup and functionality.
Zigbee wireless technology
The H1 communicates by means of the international radio standard Zigbee. To ensure a smooth communication
between the H1 and the gateway, the devices must be in direct radio range. Zigbee components join together
to form a mesh-like radio network. Components that are not within direct radio range of each other can access
other components as intermediate stations (routers) to transmit their data packets to the addressee. All compo-
nents that are permanently connected to the mains have router functionality permanently integrated.
If the direct radio link between gateway and H1 is not available in your facility (e.g. due to interfering factors
such as walls, doors, etc.), you may have to integrate additional Zigbee components that are permanently
connected to the mains into your system. Suitable for this purpose are e.g.: ubisys Router R0 or Develco Smart
Plug Mini. These and further devices with router function are available on www.smarthome-store.de. For more
information about Zigbee, please visit our website www.ubisys.de.

6Heating Control H1
Chapter 1 | General
Design H1
Display
Button
Mounting ring
Rotary dial
Battery protection foil
Display
Button
Schraubring
Drehrad
Batterie-Schutzfolie
100 mm
55 mm

7Heating Control H1
Chapter 1 | General
Display
Soll-Temperatur
Ist-Temperatur
Tag, Uhrzeit
Qualität der
Zigbee-
Funkverbindung Batteriestand
Status Zeitplan-
Einstellungen
Target temperature
Current temperature
Day, Time
Quality of the
Zigbee radio
connection Battery level
Status schedule
settings
1.3 Technical details
Permissible flow temperature up to 90 °C
Threaded connection
(to radiator valve)
M30 x 1.5
Setting force 100 N
Adjusting stroke 5.5 mm
Wireless interface frequency 2.4 GHz
Wireless interface protocol Zigbee 3.0
Protection class IP30, Protection class III
Energy supply Batteries 2 x 1.5 V, Type AA, Energizer L91, Ultimate
Lithium – or similar
Battery life up to 4 Jahre
Power consumption standby 90 μW
Power consumption maximum Aktivemax 450 mW
Dimensions 55 x 100 mm
Display size
(active area)
1,68“
(W: 33,02 x H: 26,96 mm)
Weight (with batteries) 250 g

8Heating Control H1
Chapter 2
Commissioning

9Heating Control H1
Chapter 2 | Commissioning
2.1 Mounting
1. Unmount your currently installed radiator thermostat.
2. To do this, turn the mounting ring (A) counterclockwise until the
thermostat head comes off the valve (you may need pliers for this).
Note: Don‘t worry, water can‘t leak out in the process.
3. Turn the mounting ring (A) of the H1 onto the radiator valve until it
is properly tightened. Do not use a tool for this.
Note: The H1 is suitable for all commercially available valves with
an M30 x 1.5 connection*).
*) If the H1 does not fit, you will find a list of radiator valve adapters at www.ubisys.de.
Note: To unmount the H1, please use the „Unmount“ function (Chapter 5.6).
2.2 Initial commissioning (with and without gateway)
Note: If you wish to use the H1 heating controller as stand-alone solution, you only need to follow steps 4-11.
To be able to use the full range of functions and also control the device via app, you need a Zigbee-
capable gateway, such as the ubisys G1.
This is followed by the commissioning in combination with the ubisys G1 and the ubisys Smart Home App. Be-
fore you start this, you should have commissioned the ubisys G1. If you want to operate the H1 using a gateway
and accompanying app of another manufacturer, please follow the corresponding instructions of that manufac-
turer.

10Heating Control H1
Chapter 2 | Commissioning
Initial commissioning in combination with the ubisys G1 and the ubisys Smart Home App:
1. Open the ubisys Smart Home App.
2. Tap on Configuration -> Basic Configuration -> Open for new
devices.
3. The Zigbee network is now open for about 4 minutes and your H1
heating controller can join the network.
Display
Button
Schraubring
Drehrad
Batterie-Schutzfolie
100 mm
55 mm
4. Remove the battery protection foil from your H1. The device will
now be supplied with power.
0°C
2021.09.3000:00
5. After the battery protection foil has been removed, the device auto-
matically starts up and the ubisys logo appears on the display.

11Heating Control H1
Chapter 2 | Commissioning
0°C
2021.09.3000:00
6. After the initializing process, the symbol for „Calibration“ appears
in the display.
7. The calibration of the H1 starts. The movements of the H1 valve pin
are now adjusted to the radiator valve and a status bar appears.
0°C
2021.09.3000:00
8. After successful calibration, a checkmark will appear in the display.
0°C
2021.09.3000:00
If the process fails even after several calibration attempts, there may
be a problem with your heating valve:
• Your heating valve is stuck so that the H1 cannot move it in
• Your heating valve is too long or too short so that the H1 cannot
start the calibration process
0°C
2021.09.3000:00
9. Following the calibration, the device performs the network startup
and tries to connect to an open Zigbee network. This process can
take up to approx. 7 seconds.
Note: Please make sure that the Zigbee network has been opened
via the app (see point 2).
0°C
2021.09.3000:00
10. After joining a network successfully, the display will show the cur-
rent target room temperature (center) and the actual room tempe-
rature (bottom right).
11. You can now set your desired room temperature using the rotary
dial.
Note: Also displayed, is the quality of the Zigbee wireless connec-
tion (top left), the battery status (top right) and the current actual
temperature (bottom right).

12Heating Control H1
Chapter 2 | Commissioning
12. At the same time, the app automatically jumps back to the start
screen as soon as the H1 is in the Zigbee network. The device is
recognized as a new component and displayed accordingly: 1.
0°C
2021.09.3000:00
13. After 4 seconds of inactivity, the display will turn off. To „wake up“
the display, press the key or operate the rotary dial.

13Heating Control H1
Chapter 2 | Commissioning
14. To be able to control the H1 via the ubisys Smart Home app, you
have to perform two more configuration steps in the app (naming
the components and assigning components to a room). Please
follow the steps 10 and 11 in the „ubisys Smart Home Quickstart“.
2.3 Date and time setting
To be able to create schedules for your Heating Control H1, you must first set the current date and time. Pro-
ceed as follows for this:
Display
Button
Schraubring
Drehrad
Batterie-Schutzfolie
100 mm
55 mm
1. Press and hold the button for 10 seconds to enter the second
menu.
2. By operating the rotary wheel, you can switch between the diffe-
rent menu items.
0°C
2021.09.3000:00
3. Turn the rotary knob until the symbol for „Date | Time“ appears in
the display.
4. Press the button to confirm the menu item. The symbol flashes.
5. Press the button again.

14Heating Control H1
Chapter 2 | Commissioning
0°C
2021.09.30
00:00
6. The date display appears.
7. The first four numbers (year) flash. Select the current year via the
rotary knob and confirm via the button.
8. The middle two numbers (month) flash. Select the current month
via the rotary wheel and confirm via the button.
9. The last two numbers (day) flash. Use the rotary knob to select the
current day and confirm by pressing the button.
Note: To cancel the process, press and hold the button for two
seconds.
0°C
2021.09.30
00:00
10. The time display appears.
11. The first two numbers (hour) flash. Select the current hour via the
rotary knob and confirm via the button.
12. The last two numbers (minutes) flash. Use the rotary knob to select
the current minutes and confirm by pressing the button.
Note: To cancel the process, press and hold the button for two
seconds.

15Heating Control H1
Chapter 3
Set Room
Temperature

16Heating Control H1
Chapter 3 | Set Room Temperature
3.1 How do I set the desired room temperature?
Via the rotary dial
Display
Button
Schraubring
Drehrad
Batterie-Schutzfolie
100 mm
55 mm
The desired room temperature can be set manually on the device using
the rotary dial. Pay attention to the display, which shows you the set
temperature (center) and the actual temperature (bottom right).
Via ubisys app
1. Open the ubisys app.
2. Tap on „Building Control“.

17Heating Control H1
Chapter 3 | Set Room Temperature
3. Tap on the room where the radiator with the H1 is located.
4. To set the desired room temperature, touch the actual temperature
displayed [ 21.0°C ].
5. A slider for setting the target temperature will appear. Move the
slider to the position with the desired temperature (in this case
20.0°C).

18Heating Control H1
Chapter 3 | Set Room Temperature
3.2 Switch off the heating – and switch on again
To switch off your heating with a „push of a button“ (e.g. when you leave the house for a longer period of time or
at the end of a heating period) proceed as follows:
1x + 1x
17:00
17:15
17°C
17:00
22:00
22°C
06:00
09:00
22°C
09:00
09:15
22°C
MON-SUN
6-9::22.0°C
9-17::17.0°C
MON-FRI,
SAT-SUN
MON, TUE,
WED, THU, FRI,
SAT, SUN
MON
0 6 12 18 24
MON
0 6 12 18 24
MON
0 6 12 18 24
00:00
00:00
7.0°C
106:00
09:00
22.0°C
1
09:00
09:15
22.0°C
2
1
09:00
17:00
17.0°C
2
1
06:00
09:00
22.0°C
3
206:00
09:00
22.0°C
3
2
11 06:00
09:00
22.0°C
3
2
1
1. Press the button to activate the display. Press the button again to
enter the first menu.
0°C
2021.09.3000:00
2. Select the symbol for „Switch off“ by turning the rotary wheel and
press the button to confirm.
0°C
2021.09.3000:00
3. A check mark will appear in the upper right corner and your heating
will now be switched off and will be in „frost protection“ (approx.
7°C).
The H1 is now in a kind of „sleep mode“ - but is still accessible
via the gateway. You may now still change the set temperature
in the app, but the device and thus the heating will not respond.
Only when you switch on the H1 again, the desired temperature
will be set.
Switch on heating again
Display
Button
Schraubring
Drehrad
Batterie-Schutzfolie
100 mm
55 mm
To turn your heater back on, simply set a new target temperature by
turning the dial.

19Heating Control H1
Chapter 3 | Set Room Temperature
3.3 Set temperature offset
Depending on the room conditions, the H1 may measure (and display as actual temperature) a temperature that
differs from the real condition in the room:
Furniture or curtains in front of the radiator accumulate the heated air. Then the valve closes too early and the
room remains cold. Conversely, the H1 may be permanently exposed to drafts, for example. The consequence:
The valve remains open although the desired temperature has already been reached - it becomes too warm in
the room.
To compensate for such temperature differences, the H1 offers a correction option of up to +10°C or -10°C.
For example: If it is 3°C warmer in the room than it is displayed on the H1 or in the ubisys app, +3°C must be
entered in the corresponding menu on the H1. If it is 3°C colder in the room, -3°C must be entered.
To enter a temperature offset at the H1, proceed as follows:
Display
Button
Schraubring
Drehrad
Batterie-Schutzfolie
100 mm
55 mm
1. Press and hold the button for 10 seconds to enter the menu mode.
2. By operating the rotary wheel, you can switch between the diffe-
rent menu items.
0°C
2021.09.3000:00
3. Turn the rotary dial until the symbol for „Temperature offset“ (incl.
temperature) appears in the display.
4. Press the button again to confirm the menu item.
5. The symbol incl. temperature flashes.
6. Now press the rotary dial to set the correction temperature.
7. As soon as you have made your setting, press the button again to
confirm.
8. You will automatically return to the „start page“.

20Heating Control H1
Chapter 4
Schedules
Table of contents
Other Ubisys Controllers manuals
Popular Controllers manuals by other brands

Stanley
Stanley MC521 Pro Installation and operation manual

SEW
SEW movifit mc operating instructions

GE
GE Masoneilan SVI II AP instruction manual

elsner elektronik
elsner elektronik KNX R1-B4 compact 16 A Installation and adjustment

Epcos
Epcos BR 7000 manual

MicroNova
MicroNova O026 Technical Manual for Installers