BALL VALVE SERVO INSTALLATION
BALL VALVE SERVO INSTALLATION GUIDE
Do NOT use on other types of valves.
1. CLOSE VALVE
2. PREPARE YOUR BVS
3. INSTALL BVS ON YOUR VALVE
4. CONNECT SPC AND POWER ADAPTER
Touch Sense Button
if you have oversized valve or your valve has adjacent pipe elbow, you may
slide any or both clamps in or out to fit the space.
1
Make sure the knobs are
facing on the same side as
the water valve handle
2
Check the transmission fork mechanic engagement by visual
You SHOULD NOT see the PATTERN on the top of transmission fork, if you do, you
may not install it securely, please double check, make sure you have pushed the BVS
down enough for a secured installation.
Otherwise you have a rare ultra low profile valve, the handle is too low for spring
loaded mechanic to engage, in this case, please put the Spacer between the hex
bolt head of the valve and the transmission fork.
If you don’t see the pattern without Spacer, DO NOT use the Spacer.
PATTERN NOT SEENPATTERN SEEN
Rotate the handle from position to position to turn off your valve
1 2
Align the pivot of the transmission fork is with the hex bolt
on top of the valve Press down firmly to engage the spring
loaded gear, then tighten 2 clamps.
Position the BVS over the top of the handle of ball valve
1
2
1
2
If you are installing the Ball Valve Servo outdoor, you may consider to disable the
touch sensing button to prevent it activated from rain drops or pets.
To Disable the button:
Tap and hold the touch sense button for 3 beeps, then quickly tap 3 times in a row.
If successful, the Yellow LED will flash once, then the Red LED with 1 beep. The LED
will slowly flashing Yellow indicating the touch sense button has been locked.
To Re-Enable the button:
Tap and hold the touch sense button for 3 beeps, then quickly tap 3 times in a row.
If successful, the Yellow LED will flash once, then the Red LED with 3 beeps. LED will
then slowly flashing Green (if enrolled) indicating the touch sense button has been
unlocked.
PACKAGE CONTENTS
Ball Valve Servo (BVS)
Water Detection Probe 55.1 inch
3
4
1
2 Power Adapter
Spacer
1
You may install local water detection probe (included) for close area leak detection, plug the male
jack to the female jack from the power supply cable branch, It will trigger the valve to close
whenever water is detected. (remove the protection cap from female jack first)
1 2
2
if you have purchased Smart Power Capsule, connect it
between Ball Valve Servo and power adapter. SPC is the
optional back up power device, it provides up to 32 hours of
back up power for BVS if there is a power failure.
Insert the male jack into the
water tight female jack with
extra force to secure contact and
water proof result
1
2

Contents
USER GUIDE
1 REVISION HISTORY ...............................................................................................................................................................................
2 INTRODUCTION ....................................................................................................................................................................................
2.1 What's Z-Wave? ...................................................................................................................................................................................
2.2 Custos BVS .........................................................................................................................................................................................
2.3 Connectors & Interfaces........................................................................................................................................................................
3 FEATURES & SPECIFICATIONS ..............................................................................................................................................................
3.1 Physical Specifications.........................................................................................................................................................................
3.2 Hardware Specifications .......................................................................................................................................................................
4 WORKING MODE & FEATURES...............................................................................................................................................................
4.1 Standalone ..........................................................................................................................................................................................
4.2 Mesh Network ......................................................................................................................................................................................
4.3 Ball Valve Actuator................................................................................................................................................................................
4.4 Water Leak Sensor & Alarm ...................................................................................................................................................................
4.5 Ambient Temperature Sensor.................................................................................................................................................................
5 KEY & INDICATORS BEHAVIOR ..............................................................................................................................................................
5.1 Touch Sense Button .............................................................................................................................................................................
5.2 Visual Indicator ....................................................................................................................................................................................
5.3 Sound Indicator ...................................................................................................................................................................................
6 TOUCH SENSE BUTTON KEYLOCK.........................................................................................................................................................
6.1 Keylock Enable ....................................................................................................................................................................................
6.2 Keylock Disable ...................................................................................................................................................................................
7 SETUP Z-WAVE NETWORK ....................................................................................................................................................................
7.1 Check BVS Status ................................................................................................................................................................................
7.2 Add BVS into Z-Wave Network ...............................................................................................................................................................
7.3 Remove BVS from Z-Wave Network .......................................................................................................................................................
7.4 Factory Default Reset ...........................................................................................................................................................................
8 WATER VALVE OPERATION ....................................................................................................................................................................
8.1 Force Calibration for Valve ....................................................................................................................................................................
8.2 Turn Valve to OPEN ..............................................................................................................................................................................
8.3 Turn Valve to CLOSE ............................................................................................................................................................................
8.4 Pause OPEN/CLOSE Operation ............................................................................................................................................................
8.5 Resume OPEN/CLOSE Operation .........................................................................................................................................................
9 WATER LEAK ALARM .............................................................................................................................................................................
9.1 Water Leak Detection & Alarm ...............................................................................................................................................................
9.2 Water Leak Alarm Cancellation ..............................................................................................................................................................
10 TEMPERATURE SENSOR .....................................................................................................................................................................
11 Z-WAVE SOFTWARE DEFINITION .........................................................................................................................................................
11.1 Software Specifications ......................................................................................................................................................................
11.2 Z-Wave Plus Info ................................................................................................................................................................................
11.3 Version CC ........................................................................................................................................................................................
11.4 Manufacturer Specific .........................................................................................................................................................................
11.5 Notification CC ...................................................................................................................................................................................
11.6 Indicator CC ......................................................................................................................................................................................
11.7 Basic CC Mapping of Water Valve ........................................................................................................................................................
11.8 Association Group Info(AGI) ...............................................................................................................................................................
11.9 Supported Command Classes IN NIF ...................................................................................................................................................
11.10 Configuration CC ..............................................................................................................................................................................
11.11 SmartStart Labeling ..........................................................................................................................................................................
12 APPENDIX............................................................................................................................................................................................
12.1 Z-Wave Terminology ...........................................................................................................................................................................
12.2 System Event Status ..........................................................................................................................................................................
12.3 Touch Sense Button Keylock ...............................................................................................................................................................
12.4 Operation Mode .................................................................................................................................................................................
12.5 Network Operation & Status ................................................................................................................................................................
12.6 Water Valve Operation & Status...........................................................................................................................................................
12.7 Water Leak Alarm Operation & Status ...................................................................................................................................................
12.8 Patents .............................................................................................................................................................................................
12.9 Cautions ...........................................................................................................................................................................................
12.10 Warranty .........................................................................................................................................................................................
12.11 Disclaimer .......................................................................................................................................................................................
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
3
4
6
6
6
6
6
7
7
7
7
7
7
7
7

2.1 What's Z-Wave?
2.2 Custos BVS
3.1 Physical Specifications
Model No. BVSZWU (US)/ BVSZWE (EU)
Dimensions 14.8x9.6x13.3mm
Weight BVS Unit: 603g
Body Color White
Knob Color Blue
Waterproof & Dustproof IP66 level / outdoor deployment
Usage For Indoor and Outdoor Water Valve On/Off
Operation Temperature (14~122 ℉) (-10~+50℃)
Relative Humidity 8%~80%
3.2 Hardware Specifications
Z-Wave Module ZGM130S037HGN2R
Z-Wave RF Distance 40m/131inch (Indoor) /140m/459inch(Outdoor)
Region Frequency US: 908.4 & 916MHz FCC CFR47 Part 15.249 EU: 868.42 & 869.85MHz
Motor Torque Power Adaptive torque output max: 8n.m
Water Leak Sensor Local Water Leak Sensor Probe
Temperature Sensor Built-in temperature sensor, Range from -40°C to +125°C / (-40°F to +257°F)
Action Button Touch Sense Button x 1
LED & Sound Indicator 3 colors LED. (Green, Yellow & Red); Buzzer (Max. 85dB)
Power Supply AC-DC: AC (110V 60Hz / 220V 50Hz); DC (12V / 1A)
Power Consumption Standby: ~10mA@12VDC=0.12W Full Operation: Max~700mA@12VDC=8.4W
1 REVISION HISTORY
Date: 4-Aug-2020
SW Rev: V3.06
Description:
1. Water Alarm Cancellation – Change to 1 short click from 2 short click
2. Water Alarm Timeout – Water Leak Alarm UI 30 seconds timeout before BVS
physical installation is triggered.
3. Leak Sensor Detection – Extended to 1 second detecting time from 10ms
Section: UI / Operation / Logic
2 INTRODUCTION
Z-Wave is international wireless protocol used for Smart Home. It’s a mesh
network technology to ensure reliable two-way communication with each other.
Z-Wave provides interoperability and security from multi-vendors to make sure
Certified Products work within any Z-Wave network.
Custos Ball Valve Servo “Custos BVS” is capable for outdoor deployment for
controlling quarter turn water valve OPEN / CLOSE. It also supports auto CLOSE
valve when water leak is detected by Local Leak Sensor Probe. Custos BVS can
be operated in any Z-Wave network with other Z-Wave certified gateways or
devices from other manufacturers. All mains operated nodes within the network
will act as signal repeater regardless of vendor to increase reliability of the
network.
Sound indicator Buzzer
Temperature sensor Built-in temperature sensor
Visual indicators 3 Colors LED with green, yellow & red
Touch sense button Network, water valve and alarm operations
Knob Use to adjust Clamp widths
DSK label Z-Wave “SmartStart” and product label
2.3 Connectors & Interfaces
Serial number Serial number label
Clamp Clamp on water pipe. Max 1-1/4 inch
Driving fork Couple with valve handle
Power connector DC 12V / 1A in
Dust cover Prevent Dust and Water
Leak sensor connector Local leak sensor probe
FCC ID: 2AUZX-BVSZWU
DC12V 1ABVSZWU US908.4/916Mhz
Assembled in China
S/N:000212030009012
Ball Valve Servo
Designed by
IP66
48267
Device Specific Key
IC ID: 26 714-BVS ZWU
ac
d
e
fg
h
j
k
l
b
Type A Type B
Depend on region and valve types there
are 2 types of driving forks
iDriving fork
4 WORKING MODE & FEATURES
4.1 Standalone
- Support Water Valve Operation, Water Leak detection & Alarm, Inclusion,
Exclusion and Factory Default Reset.
- By default, Custos BVS is in Standalone Mode with Factory Default Setting and
it’s not belonged to any Z-Wave Mesh Network.
- End user can enjoy all regular functions without Z-Wave benefit. Such as Water
Valve, Leak detection by Local Leak Sensor Probe.
4.2 Mesh Network
- Support SmartStart, Classic Inclusion, Exclusion & Factory Default Reset.
- After Adding Custos BVS to a Z-Wave Mesh Network, end-customer can fully
enjoy all functions, such as remote control, associate with other Z-Wave end
devices…
4.3 Ball Valve Actuator
4.4 Water Leak Sensor & Alarm
4.5 Ambient Temperature Sensor
- Support OPEN, CLOSE, PAUSE
- RESUME during OPEN/CLOSE operation.
- Manual Calibration position of valve handle. (Only support operate by Touch
Sense Button)
- Water Valve will be closed automatically once Local Water Leak Sensor Probe
is triggered.
- Water Valve can be triggered with associated other Z-Wave end-devices. (Only
in Mesh Network Mode)
- Water Leak Alarm will be activated and to CLOSE Water Valve automatically
once Local Water Leak is detected.
- Once Local Water Leak is detected then BVS will also send out Water Leak
Alarm with no location support to Z-Wave Gateway. (Only in Mesh Network
Mode)
- By default, BVS sends temperature report automatically to gateway when every
1°C or 1.8°F degree changed. (Only in Mesh Network Mode).
a
c
d
e
f
g
h
j
k
l
b
i
PAGE 1
Ub itech Ltd . Ve rsion : 3.0
3 FEATURES & SPECIFICATIONS

6 TOUCH SENSE BUTTON KEYLOCK
Custos BVS is capable for outdoor deployment. To prevent mis-operation by rain
drop, end-user can enable Touch Sense Button Keylock function.
After enabled Touch Sense Button Keylock function, Custos BVS will not accept
any key event excepting Touch Sense Button Keylock Disable function. (Refer to
7.2)
i. Start: Long hold Touch Sense Button with 3 beep sounds then short click 3
times.
ii. Process: Yellow LED on 1 second then Red LED on 1 second with 1 beep sound.
i. Start: Long hold Touch Sense Button with 3 beep sounds then short click 3 times.
ii. Process: Yellow LED on 1 second then Red LED on 1 second with 3 beep
sounds.
iii. Success: LED indicator resume previous status. (Yellow LED blinking or Green
LED slow blinking)
6.1 Keylock Enable
6.2 Keylock Disable
7 SETUP Z-WAVE NETWORK
7.1 Check BVS Status
7.2 Add BVS into Z-Wave Network
7.3 Remove BVS from Z-Wave Network
7.4 Factory Default Reset
8.1 Force Calibration for Valve
i. Before Adding into Z-Wave Network, you have to make sure Custos BVS is in
Standalone mode.
ii. By default, Custos BVS does not belong to any Z-Wave Network and color
indicator is keeping in Yellow Blinking. *If not, please perform “Factory Default
Reset- refer to 8.4” or “Remove from Z-Wave Network – refer to 8.3”
Custos BVS supports Security 2 Command Class while a Security S2 enabled
controller is needed. It supports SmartStart and Classic Inclusion.
i. SmartStart:
By using SmartStart, end-user by scanning the Z-Wave QR code or entering PIN
Code or DSK String into S2 Enabled Gateway.
Please refer to 12.11 SmartStart Labeling. To enable Security S2 in Gateway,
please refer to Gateway’s user manual.
ii. Classic Inclusion:
To be used if your controller does not support SmartStart
a. Set your Z-Wave Gateway into Inclusion mode / Add device.
b. On your Custos BVS
- Start: Short press Touch Sense Button 3 times.
- Processing: Yellow LED and short beep sound keeping continue. For security
inclusion support, you may need to entering first 5 digit that show on QR Code
label, please refer to the instructions of central controller.
- Success: Green LED on 1 second with 2 short beep sounds.
- The LED indication changes to Green LED slow blinking from Yellow LED
blinking.
Set your Z-Wave Gateway into Exclusion mode / Remove device.
i. Start: Short press Touch Sense Button with 3 beep sounds.
ii. Processing: Yellow LED and short beep sound keeping continue.
iii. Success: Green LED on 1 second with 2 short beep sounds.
iv. The LED indication Changes to Yellow LED blinking.
To remove Custos BVS without involve gateway in Exclusion / Remove device
operation and BVS will reset all setting to Factory Default Setting. “Please use this
procedure only when the network primary controller is missing or otherwise
inoperable”
i. Start: Long hold Touch Sense Button with 10 beep sounds then short click 5
times.
ii. Processing: Yellow LED ON 1 second then wait 2-5 seconds.
iii. Success: Green LED on 2 second with long beep sounds for 2 seconds.
*Factory Default Reset will:
a. Remote the BVS from Z-Wave Network;
b. Delete the association setting;
c. Restore the configuration settings to the default.
8 WATER VALVE OPERATION
Calibration function will identify the correct OPEN/CLOSE position and torque
force, it will avoid excess stress applied to your valve.
By default, BVS will perform Auto-calibration when power on.
i. Start: Long Hold Touch Sense Button with 5 beep sounds, then short click 5
times.
ii. Processing: Water Valve run OPEN and CLOSE 1-2 cycles, Yellow LED blinking
and quick short beep sound keep continue.
iii. Success: The LED indicator changes to Yellow LED blinking.
8.2 Turn Valve to OPEN
8.3 Turn Valve to CLOSE
8.4 Pause OPEN/CLOSE Operation
Turn Valve to OPEN position and let water run through the pipe.
i. Start: Short click Touch Sense Button 1 time.
ii. Processing: Water Valve turning to OPEN position, Green Heartbeat LED
blinking “Fade-in & Fade-out” and short beep sound keep continue.
iii. Success: The LED indicator changes to Yellow LED blinking
Turn Valve to CLOSE position and doesn’t let water run through the pipe.
i. Start: Short click Touch Sense Button 1 time.
ii. Processing: Water Valve turning to CLOSE position, Yellow Heartbeat LED
blinking “Fade-in & Fade-out” and short beep sound keep continue.
iii. Finished: The LED indicator changes to Yellow LED blinking
Pause only take effect during OPEN or CLOSE operation.
i. Start: Short click Touch Sense Button 1 time.
ii. Processing: Yellow LED blinking and Valve stop operation.
8.5 Resume OPEN/CLOSE Operation
Resume only take effect during Pause operation.
i. Start: Short click Touch Sense Button 1 time.
ii. Finished: Valve resume to operation (Continue to Opening / Closing) and LED
indicator changes to LED blinking.
9 WATER LEAK ALARM
9.1 Water Leak Detection & Alarm
Custos BVS comes with Local Leak Sensor Probe and support following functions,
in short, once Water Leak is detected, Water Leak Alarm will be activated, hence
the water valve will be closed spontaneously, at this moment all other operations
will not be accepted except Water Leak Alarm Cancellation.
i. Activated Water Leak Alarm
- RED LED fast blinking.
- Fast beep sound.
ii. CLOSE Water Valve automatically
iii. Send out Water Alarm Notification to Z-Wave Gateway. (Only support in Mesh
Network Mode)
iv. Water Valve keeps in CLOSE position
v. The operation is forbidden temporally until perform Water Alarm Cancellation
operation. (Refer 10.2)
9.2 Water Leak Alarm Cancellation
Water Leak Alarm Cancellation operation only accepted when Local Water Leak
Sensor Probe is no longer detected water.
i. Start: Long hold Touch Sensor Button with 2 beep sounds
ii. Success: The LED indicator changes to previous status. (Yellow LED blinking
or Green LED slow blinking and buzzer goes silence.)
Ub itech Ltd . Ve rsion : 3.0
5 KEY & INDICATORS BEHAVIOR
5.1 Touch Sense Button
5.2 Visual Indicator
5.3 Sound Indicator
- Short Press: One click comes with one short beep sound.
- Long Hold: Press and holding the key. “Come with 1 x short beep sound per
second”
- 3 Colors LED: GREEN, YELLOW & RED
- ON Event: ON, quick blinking and slow blinking
Buzzer: Long & short beep sound.
PAGE 2

11.6 Indicator CC
Basic CC Map to CC Value
Basic Set Binary Switch Set 0x00 = ON / Water Valve OPEN (Valve lets water run through)
0xFF = OFF / Water Valve CLOSE (Valve doesn’t let water run through)
Basic Report Binary Switch Report 0x00 = ON / Water Valve OPEN (Valve lets water run through)
0xFF = OFF / Water Valve CLOSE (Valve doesn’t let water run through)
Parameter Value
Indicator ID 0x50 = (Node Identify)
Property ID 0x03 = (On/Off Periods)
0x04 = (On/Off Cycles)
0x05 = (On time within an On/Off period)
11.7 Basic CC Mapping of Water Valve
11.8 Association Group Info (AGI)
Association
Group Name Node Function
1 Lifeline 5 -Device Reset Locally N otification
-Basic Report
-Binary Switch Report
-Indicator Report
-Sensor Multilevel Report–Temperature “Auto report based on Configuration Parameter 0x22 Setting. ”
-Heat Alarm Notification Report (0x04)
-0x00 = State id le
-0x02 = Overhe at – no location support
-0x06 = Underheat – no location support
-Water Alarm Notification Report (0x05)
-0x00 = State id le
-0x02 = Water leak detected – no location support
-Water Valve Notification Report (0x0F)
-0x01 = Valve operation
0x00 = VALVE CLOSED/OFF (Valve does not let the wa ter run through.)
0x01 = VALVE OPEN/ON ( Valve lets the water run thr ough)
2 Water Valve 5 -Basic Set(By default the Configuration CC parameter 0x11 (17)
“Inverse Water Valve report ” is enabled to send out following report.)
-0x00 = Let the wa ter run through (Based on Configuration Parameter 0x13)
-0xFF = Doesn’ t let the water run through. (Based on Configuration Paramet er 0x12)
3 Leak Sensor 5 -Basic Set
-0x00 = IDLE / CAN CEL (Based on Configuration Parame ter 0x32 Setting)
-0xFF = TRIGGERED (Based on Configuration Parameter 0x31 Setting)
4 Overheat 5 -Basic Set Alarm
-0x00 = IDLE / CAN CEL (Based on Configuration Parame ter 0x27 Setting)
-0xFF = TRIGGERED (Based on Configuration Parameter 0x26 Setting)
5 Freeze Alarm 5 - Basic Set
-0x00 = IDLE / CAN CEL (Based on Configuration Parame ter 0x2C Setting)
11.9 Supported Command Classes IN NIF
Command Class Version Not Added
Added
Security 0 Added Security 2 Added
ZWAVEPLUS_INFO 2 Support Support Support --- Support ----
SWITCH_BINARY 2 Support Support --- Support --- Support
ASSOCIATION 3 Support Support --- Support --- Support
MULTI_CHANNEL_ASSOCIATION 4 Support Support --- Support --- Support
ASSOCIATION_GRP_INFO 3 Support Support --- Support --- Support
NOTIFICATION 8 Support Support --- Support --- Support
TRANSPORT_SERVICE 2 Support Support Support --- Support ---
VERSION 3 Support Support --- Support --- Support
MANUFACTURER_SPECIFIC 2 Support Support --- Support --- Support
DEVICE_RESET_LOCALLY 1 Support Support --- Support --- Support
INDICATOR 3 Support Support --- Support --- Support
POWERLEVEL 1 Support Support --- Support --- Support
SECURITY 1 Support Support Support --- Support ---
SECURITY_2 1 Support Support Support --- Support ---
SUPERVISION 1 Support Support Support --- Support ---
FIRMWARE_UPDATE_MD 5 Support Support --- Support --- Support
SENSOR_MULTILEVEL-Temperature 11 Support Support --- Support --- Support
CONFIGURATION 4 Support Support --- Support --- Support
APPLICATION STATUS 1 Support Support Support --- Support ---
BASIC COMMAND 2 Support Support Support Support Support Support
BATTERY 1 Support Support --- Support --- Support
PAGE 3
Ub itech Ltd . Ve rsion : 3.0
11.2 Z-Wave Plus Info
2
5 (ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_ON)
0 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE)
0x1500 (ICON_TYPE_GENERIC_VALVE_OPEN_CLOSE)
0x1500 (ICON_TYPE_GENERIC_VALVE_OPEN_CLOSE)
Role Type
Node Type
Installer Icon Type
User Icon Type
11.3 Version CC
Notification Type Notification Events / State Description
Heat Alarm 0x04 State idle 0x00 Notification value for the state variable going to idle (V5)
Overheat detected 0x02 No Location Support Event
Underheat detected 0x06 No Location Support Event
Water Alarm 0x05 State idle 0x00 Notification value for the state variable going to idle (V5)
Water leak detected 0x02 No Location Support Event
Water Valve 0x0F Valve operation status 0x01 Event Parameter 1 byte=
-0x00 =Valve does not let the water run through
-0x01 =Valve lets the water run through
Parameter Value
Z-Wave Protocol Library Type 0x03
Z-Wave Protocol Version 0x07
Z-Wave Protocol Sub Version 0x0D
Firmware 0 Version 0x03 – Z-Wave Chip Major Firmware Version
Firmware 0 Sub Version 0x02 – Z-Wave Chip Minor Firmware Version
Hardware Version 0x03
Number of firmware targets 0x00
11.4 Manufacturer Specific
Parameter Value
Manufacturer ID 1 0x02
Manufacturer ID 2 0x70
Product Type ID 1 0x01
Product Type ID 2 0x01
Product ID1 0x00
Product ID 2 0x0A
11.5 Notification CC
Z-Wave Plus Version
10 TEMPERATURE SENSOR
i. By default, Custos BVS will send report to Gateway automatically in 1 °C or 4°F
change of ambient temperature.
ii. Custos will send out °F in US version and °C for other versions.
11 Z-WAVE SOFTWARE DEFINITION
11.1 Software Specifications
Parameter Value
Generic Device Type
Wireless Technology
Z-Wave Certification Type
Z-Wave SDK Version
Z-Wave Library
Z-Wave Role Type
Device Type
Specific Device Type
Security Class
SmartStart
Firmware Update
Association
Factory Default Reset
Power Down Memory
Z-Wave
Z-Wave Plus v2Certification
V7.13.2
Enhanced 232 Slave
Always On Slave
Binary Switch
Switch Binary
Specific Type Not Used
Non-Security, S0, S2 Unauthenticated and S2 Authenticated
Support: SmartStart is auto activated if it’s out of Z-Wave network when power on
Support: Firmware upgrade support via RF, “Over The Air (OTA)”
Support 5 Groups. Lifeline, Water Valve, Water Leak, Overheat & Underheat
Support: Device Locally Reset
Support: Valve ON/OFF status, Leak Alarm supportsuddenly power cut and restoreprevious status

PAGE 4
Ub itech Ltd . Ve rsion : 3.0
11.10 Configuration CC
Note: No Bulk Support equals to True. It will return an Application Rejected Request Command
when receiving Configuration Bulk Set or Get (if received without Supervision encapsulation). It
will reset all its configuration parameters if either manually reset to factory default or receives a
Configuration Default Reset Command. It will NOT modify or reset any configuration parameter
when being included or excluded of a Z-Wave network.
User Interface
Parameter No. 0x41 (65)
Name Buzzer
Info Enable / Disable Buzzer
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x01 (1)
Read only False Default Value 0x01 (1)
Altering capabilities False Advanced False
Description Enable / Disable Built-in Buzzer Sound
Value Function
0x00 (0) Disable Buzzer
0x01 (1) * Default Value Enable Buzzer
Parameter No. 0x42 (66)
Name LED Brightness Level
Info Configure LED Brightness Level
Properties Size 1 Byte Min Value 0x00 (0%)
Format Unsigned Integer Max Value 0x63 (99%)
Read only False Default Value 0x50 (80%)
Altering capabilities False Advanced False
Description Configure Built-in LED Brightness Level
Value Function
0x00 ~ 0x63 0% ~ 99%
Parameter No. 0x43 (67)
Name Touch Keylock Protection
Info Disable / Enable Touch Keylock Protection
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x01 (1)
Read only False Default Value 0x01(0)
Altering capabilities False Advanced False
Description Disable / Enable Touch Keylock Protection
Value Function
0x00 (0) * Default Value Disable Keylock Protection
0x01 (1) Enable Keylock Protection
Notification Report
Parameter No. 0x51 (81)
Name Notification Report Lifeline
Info Configure Notification Report (Bitmask)
Properties Size 1 Byte Min Value 0x00 (0)
Format Bit Field Max Value 0x0F (15)
Read only False Default Value 0x0D (13)
Altering capabilities False Advanced False
Description Configure Notification Report in Association Group 1 Lifeline “Set Bit to 0 = Disable, Set Bit to 1 = Enable”
Value Function
Bit 0 Water Valve Open / Close – 0 = Disable / *1 = Enabled
Bit 1 Overheat Detection – *0=Disable / 1=Enable
Bit 2 Freeze Detection – 0=Disable / *1 = Enable
Bit 3 Local Water Leak Sensor Probe Detection – 0=Disable / *1=Enable
Water Valve
Parameter No. 0x11 (17)
Name Inverse Water Valve Report
Info Inverse Switch Binary Report value
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x01 (1)
Read only False Default Value 0x01 (1)
Altering capabilities False Advanced False
Description Inverses Switch Binary Report when Water Valve = 0x00 “Valve doesn’t let the water run through in
Notification and real physical status.”
Value Function
0x00 (0) Disable: 0x00 = does not let water run through, 0xFF = let water run through.
Based on Configuration CC setting 0x12 & 0x13
0x01 (1) * Default Value Enable: 0x00 = let water run through, 0xFF = does not let water run through
Based on Configuration CC setting 0x12 & 0x13
Parameter No. 0x12 (18)
Name Association Group 2 SET Value
Info Valve SET Value when receives 0xFF
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x02 (2)
Read only False Default Value 0x01 (1)
Altering capabilities False Advanced False
Description Configure Association Group 2 Basic Set value when Binary Switch Report = 0xFF *(Related to
Configuration setting 0x11)
Value Function
0x00 (0) Disable Basic Set (Send nothing)
0x01 (1) * Default Value Basic ON (0xFF)
0x02 (2) Basic OFF (0x00)
Parameter No. 0x13 (19)
Name Association Group 2 SET Value
Info Valve SET Value when receives 0x00
Properties
Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x02 (2)
Read only False Default Value 0x02 (2)
Altering capabilities False Advanced False
Description Configure Association Group 2 Basic Set value when Binary Switch Report = 0x00 *(Related to Configuration
setting 0x11)
Value Function
0x00 (0) Disable Basic Set (Send nothing)
0x01 (1) Basic ON (0xFF)
0x02 (2) * Default Value Basic OFF (0x00)

Temperature Sensor - 1
Parameter No. 0x21 (33)
Name Temperature Report Unit
Info Configure reporting temperature unit
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x02 (2)
Read only False Default Value 0x02 (2)
Altering capabilities False Advanced False
Description Configure Temperature Unit report. The default Unit is depended on Regional Frequency Setting. (By default,
US=°F and EU=°C)
Value Function
0x00 (0) Disable Auto Temperature Report
0x01 (1) Report Celsius °C unit
0x02 (2) * Default Value Report Fahrenheit °F unit
Parameter No. 0x22 (34)
Name Temperature Threshold Change
Info Temperature threshold to auto report
Properties Size 2 Bytes Min Value 0x0000 for °C / 0x0100 for °F
Format Unsigned Integer Max Value 0x00FF for °C / 0x01FF for °F
Read only False Default Value 0x0001 = 1°C / 0x0104 = 4 °F
Altering capabilities False Advanced False
Description Configure Temperature threshold changed and send auto report
Value Function
0x0000 ~ 0x00FF Higher Byte set to x0 represents Celsius °C unit
0x0100 ~ 0x01FF Higher Byte set to x1 represents Fahrenheit °F unit
Parameter No. 0x23 (35)
Name Temperature Report Offset
Info Configure reporting temperature offset
Properties Size 2 Bytes Min Value 0x0000 for °C / 0x0100 for °F
Format Unsigned Integer Max Value 0x10FF for °C / 0x11FF for °F
Read only False Default Value 0x0000 = 0°C / 0x0100 = 0 °F
Altering capabilities False Advanced False
Description Configure Temperature Offset degree; Higher byte 0x = Positive degree and 1x= Negative degree
Value Function
0x0000 ~ 0x10FF 0x0000~0x00FF, (0~+255); Higher Byte 00 = Positive Celsius “+°C” e.g. 0x0002 = +2°C
0x1000~0x10FF, (-0~-255); Higher Byte 10 = Negative Celsius “-°C” e.g. 0x1002 = -2°C
0x0100 ~ 0x11FF 0x0100~0x01FF, (0~+255); Higher Byte 01=Positive Fahrenheit “+°F” e.g. 0x010A = +10°F
0x1100~0x11FF, (-0~-255); Higher Byte 10=Negative Fahrenheit “-°F” e.g. 0x110A = -10°F
Parameter No. 0x24 (36)
Name Overheat Trigger Value
Info Configure overheat report trigger value
Properties Size 2 Bytes Min Value 0x0000 for °C / 0x0100 for °F
Format Unsigned Integer Max Value 0x00FF for °C / 0x01FF for °F
Read only False Default Value 0x0028=40°C / 0x0168=104 °F
Altering capabilities False Advanced False
Description Configure Overheat report trigger value. “Higher byte 0x00 represents Celsius °C unit, 0x01 represents
Fahrenheit °F unit
Value Function
0x0000 ~ 0x00FF From 0°C to 255°C
0x0100 ~ 0x01FF From 0°F to 255°F
Parameter No. 0x25 (37)
Name Overheat Recover value
Info Configure overheat recover report value
Properties Size 2 Bytes Min Value 0x0000 for °C / 0x0100 for °F
Format Unsigned Integer Max Value 0x00FF for °C / 0x01FF for °F
Read only False Default Value 0x001E = 30°C / 0x0156 = 86°F
Altering capabilities False Advanced False
Description Configure Overheat Recover Value
Value Fun c t i o n
0x0000 ~ 0x00FF From 0°C to 255°C
0x0100 ~ 0x01FF From 0°F to 255°F
Temperature Sensor - 2
Parameter No. 0x26 (38)
Name Association Group 4 Overheat Trigger
Info Overheat Trigger SET value
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x02 (2)
Read only False Default Value 0x00 (0)
Altering capabilities False Advanced False
Description Configure Overheat Trigger Value in Association Group 4
Value Function
0x00 (0) * Default Value Disable Basic Set (Send nothing)
0x01 (1) Send Basic ON (0xFF)
0x02 (2) Send Basic OFF (0x00)
Parameter No. 0x27 (39)
Name Association Group 4 Overheat Cancel
Info Overheat Cancellation SET value
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x02 (2)
Read only False Default Value 0x00 (0)
Altering capabilities False Advanced False
Description Configure Overheat Cancellation SET value
Value Function
0x00 (0) * Default Value Disable Basic Set (Send Nothing)
0x01 (1) Send Basic ON (0x0FF)
0x02 (2) Send Basic OFF (0x00)
Parameter No. 0x28 (40)
Name Freeze Trigger Value
Info Configure Freeze Trigger Report value
Properties Size 2 Bytes Min Value 0x0000 for °C / 0x0100 for °F
Format Unsigned Integer Max Value 0x00FF for °C / 0x01FF for °F
Read only False Default Value 0x0000=0°C / 0x0120=32 °F
Altering capabilities False Advanced False
Description Configure Freeze Trigger Report Value
Value Function
0x0000 ~ 0x00FF From 0°C to 255°C
0x0100 ~ 0x01FF From 0°F to 255°F
Parameter No. 0x29 (41)
Name Freeze Recover Value
Info Configure Freeze Recover Report Value
Properties Size 2 Bytes Min Value 0x0000 for °C / 0x0100 for °F
Format Unsigned Integer Max Value 0x00FF for °C / 0x01FF for °F
Read only False Default Value 0x0002=2°C / 0x0124=36 °F
Altering capabilities False Advanced False
Description Configure Freeze Recover Report Value
Value Function
0x0000 ~ 0x00FF From 0°C to 255°C
0x0100 ~ 0x01FF From 0°F to 255°F
Parameter No. 0x2A (42)
Name Freeze Detection Valve Control
Info Configure Valve Control during freeze
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x01 (1)
Read only False Default Value 0x01 (1)
Altering capabilities False Advanced False
Description Enable / Disable Valve Control during Freeze when Water Leak is detected “Detected by built-in temperature
sensor. Refer to Configuration CC parameter 0x28 (41) & 0x29 (42)
Value Function
0x00 (0) Ignore / Allowed to control Water Valve during Freeze detection
0x01 (1) * Default Value Forbidden to control Water Valve during Freeze detection
Parameter No. 0x2B (43)
Name Association Group 5 Freeze Trigger
Info Configure Freeze Trigger SET value
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x02 (2)
Read only False Default Value 0x00(0)
Altering capabilities False Advanced False
Description Configure Association Group 5 Freeze Detection Trigger Basic Set value
Value Function
0x00 * Default Value Disable Basic Set (Send nothing)
0x01 Basic Set ON (0xFF)
0x02 Basic Set OFF (0x00)
Parameter No. 0x2C (44)
Name Association Group 5 Freeze Cancel
Info Freeze Cancellation SET value
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x02 (2)
Read only False Default Value 0x00 (0)
Altering capabilities False Advanced False
Description Configure Association Group 5 Freeze Detection Cancellation Basic Set value
Value Function
0x00 (0) * Default Value Disable Basic Set (Send nothing)
0x01 (1) Basic Set ON (0xFF)
0x02 (2) Basic Set OFF (0x00)

Water Leak
Parameter No. 0x31 (49)
Name Association Group 3 Water Leak Trigger
Info Water Leak Trigger SET value
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x02 (2)
Read only False Default Value 0x01 (1)
Altering capabilities False Advanced False
Description Configure Association Group 3 Water Leak Trigger Basic Set value
Value Function
0x00 (0) Disable Basic Set (Send nothing)
0x01 (1) Basic Set ON (0xFF)
0x02 (2) * Default Value Basic Set OFF (0x00)
Parameter No. 0x32 (50)
Name Association Group 3 Water Leak Cancel
Info Water Leak Cancellation SET value
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x02 (2)
Read only False Default Value 0x00 (0)
Altering capabilities False Advanced False
Description Configure Association Group Water Leak Cancellation Basic Set value
Value Function
0x00 (0) Disable Basic Set (Send nothing)
0x01 (1) Basic Set ON (0xFF)
0x02 (2) * Default Value Basic Set OFF (0x00)
Parameter No. 0x33 (51)
Name Water Leak Detection Valve Control
Info Disable / Enable Water Leak Valve Control
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x01 (1)
Read only False Default Value 0x01(1)
Altering capabilities False Advanced False
Description Disable / Enable Valve Control when Water Leak detected
Value Function
0x00(0) Disable to control Water Valve when Water Leak is detected
0x01 * Default Value Enable to control Water Valve when Water Leak is detected
0x02 Basic Set OFF (0x00)
PAGE 6
Ub itech Ltd . Ve rsion : 3.0
Valve Auto-Calibration
Parameter No. 0x61 (97) – General
Name 1/8 Turn Autorun Mode Set
Info Set 1/8 Turn Autorun for Inclusion/Exclusion
Properties Size 1 Byte Min Value 0x00 (0)
Format Bit Field Max Value 0x03 (3)
Read only False Default Value 0x01 (1)
Altering capabilities False Advanced False
Description Enable/Disable 1/8 Turn Autorun at Standalone or Network Modes. (Excluded/ Included to Z-Wave Network)
Value Function
0x00 (0) Disabled 1/8 turn Autorun Function in Both Mode.
0x01 (1) *Default Value Enable 1/8 turn autorun in Standalone Mode “Excluded from Z-Wave Network”
0x02 (2) Enable 1/8 turn autorun in Network Mode “Included to Z-Wave Network"
0x03 (3) Enable 1/8 turn autorun in both modes. (Standalone & Network Mode)
Parameter No. 0x62 (98)
Name 1/8 Turn Autorun Time Interval
Info Set 1/8 Turn Autorun Time Interval in day
Properties Size 1 Byte Min Value 0x01 (1)
Format Unsigned Max Value 0x1E (3)
Read only False Default Value 0x0E (14)
Altering capabilities False Advanced False
Description Set 1/8 Turn Autorun Time Interval in 1 – 30 days. (Also refer to CC parameter 0x61 (97)
Value Function
0x01 ~ 0x1E (1 ~ 30)
*0x0A(10)-Default Value From 1 day to 30 days
Parameter No. 0x71 (113)
Name Battery Threshold Change Report
Info Set Battery Threshold Level Change
Properties Size 1 Byte Min Value 0x00 (0)
Format Unsigned Max Value 0x63 (99)
Read only False Default Value 0x0A (10)
Altering capabilities False Advanced False
Description Set Battery Threshold Level Change Report
Value Function
0x00 ~ 0x63 (0 ~ 99%)
*0x0A(10)-Default Value From 0 ~ 99%
Battery-SPC Support
Parameter No. 0x72 (114)
Name Low Battery Level Set
Info Low Battery Level Set
Properties Size 1 Byte Min Value 0x00 (0)
Format Unsigned Max Value 0x63 (99)
Read only False Default Value 0x1E (30)
Altering capabilities False Advanced False
Description Set Low Battery Level Report
Value Function
0x00 ~ 0x63 (0 ~ 99%)
*0x1E(30)-Default Value From 0% ~ 99%
Parameter No. 0x73 (115)
Name Low Battery To Trigger BVS Close Action
Info Set Low Battery Trigger to Close BVS
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x01 (1)
Read only False Default Value 0x01 (1)
Altering capabilities False Advanced False
Description Set Trigger Action To Close Water Valve When Received Low Battery Report
Value Function
0x00 (0)
0x01(1)*Default Value
Disable
Enable
11.11 SmartStart Labeling
BVS comes with PIN Code, DSK string and QR Code for SmartStart and as shown
in the examples below. The real QR Code can be found on product and package.
- PIN Code with QR Code on BVS’s housing.
SmartStart Pin Code: 12345
DSK:12345-xxxxx-xxxxx-xxxxx-xxxxx-xxxxx-xxxxx-xxxxx
DSK String with QR Code on Packing, the first 5 digits is PIN code for SmartStart.
12 APPENDIX
12.1 Z-Wave Terminology
12.2 System Event Status
12.3 Touch Sense Button Keylock
Z-Wave Functionality Documentation Terminology Description
Inclusion Add The process of adding a node to Z-Wave Network
Exclusion Remove The process of removing a node from Z-Wave Network
Event Detail LED Buzzer
System Ready BVS is Ready to operate after power on or reset. Green LED ON 2 seconds 2 beep sounds
Standalone mode heartbeat Standalone Heartbeat without network connection Yellow LED blinking ---
Network mode heartbeat Mesh Network Mode Heartbeat Green LED slow blinking ---
Event Success Finished operation and success Green LED ON 2 seconds Short beep x 2
Event Error Operation fail or not available RED LED blinking 3 times Long beep x 3
Event Timeout Operation timeout RED LED ON 1” Pulse sound
Event Action/Status Key Action LED Status Buzzer Status
Keylock Enable Enable Lock Key Function Long beep x 1
Success–“In Mesh Network Mode” — Yellow LED slow blinking —
Success– “In Standalone Mode” --- Yellow LED blinking ---
Keylock Disable Disable Lock Key Function Yellow LED blinking Long beep x 3
Success–“In Mesh Network Mode” --- Green LED slow blinking —
Success – “In Standalone Mode” --- Yellow LED blinking —
Long hold with 3 beep
sounds& click 3 times
Yellow LED ON 1 second
Red LED ON 1 second
Long hold with 3 beep
sounds& click 3 times

12.6 Water Valve Operation & Status
Start PAUSE “Only available during
Open/Close operation
Event Action / Status Key Action LED Status Buzzer Status
Start OPEN (Valve in closed position) Short Click 1 time Yellow LED keep blinking —
Processing --- Yellow LED keep blinking Keep short beep
Success --- Green LED ON 1 second Short beep x 2
Next status (In Network Mode) --- Green LED slow blinking —
Next status (In Standard Mode) --- Yellow LED slow blinking —
Start CLOSE (Valve in open position) Click 1 time Green LED ON 1 second 1” Pulse sound
Processing --- Yellow LED keep blinking Keep short beep
Success --- Green LED ON 1 second Short beep x 2
Next status(In Network Mode) --- Green LED slow blinking ---
Next status (In Standard Mode) --- Yellow LED slow blinking ---
Click 1 time 1” Pulse sound
Processing-“In Network Mode” --- Yellow LED slow blinking ---
Next status – “In Network Mode” --- Green LED keep blinking ---
Processing – “In Standalone Mode” --- Yellow LED keep blinking ---
Next status – “In Standalone Mode” --- Yellow LED keep blinking ---
Click 1 time Green LED ON 1 second Short beep x 3
Next Status – Return Open/Close --- Yellow/Green LED blinking Keep short beep
Start Manual Calibration) --- ---
Processing–Open&Close 1-2 cycles --- Yellow LED keep blinking Keep short beep
Next status – “In Network Mode” --- Green LED slow blinking ---
Next status – “In Standalone Mode” --- Yellow LED keep blinking ---
OPEN Valve
Yellow LED ON 1 second
Red LED ON 1 second
CLOSE
Valve
PAUSE
Operation
RESUME
Operation
Manual
Calibration
Start RESUME “Only available
during Open/Close operation
Long hold with 5
beep sounds &
click 5 times
Event Action/Status Key Action LED Status Buzzer Status
Start Water Leak Alarm --- RED LED fast blinking Fast beep sound
— RED LED fast blinking Fast beep sound
Alarm Cancellation Green LED blinking 2 times Short beep x 2
Success cancellation --- Green LED blinking 3 times Short beep x 3
Next Status–“In Mesh Network Mode” --- Green LED slow blinking —
Nest Status – “In Standalone Mode” --- Yellow LED blinking —
Processing – Close Water
Valve automatically
Long hold with 2
beep sounds
Leak Alarm
Cancellation
Leak Sensor
Probe
Triggered
12.7 Water Leak Alarm Operation & Status
12.8 Patents
Patent 1: US 11,233,501 B1
Patent 2: US 10,995,876 B2
PAGE 7
Ub itech Ltd . Ve rsion : 3.0
12.9 Cautions
MOVING PARTS WARNING: Keep hands, hair and all loose articles of clothing away from moving parts. Moving
parts can cause serious Injury. Maintain a safe distance from the product during its operation to eliminate risk of
injury.
POWER SUPPLY WARNING: The power supply is for indoor use only. Only use power supply included with your
product. Do not attempt to repair or use a damaged power supply. Do not immerse the power supply in water or
subject it to physical abuse. Inspect the power supply regularly for cable, plug damage.
CORRECT DISPOSAL OF BATTERIES IN THIS PRODUCT: This marking on the product, accessories or literature
indicates that the product and its electronic accessories should not be disposed of with other household waste. To
prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these
items from other types of waste and recycle them responsibly to promote the sustainable reuse of material
resources.
Household users should contact either the retailer where they purchased this product, or their government office, for
details of where and how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This
product and its electronic accessories should not be mixed with other wastes for disposal.
This marking on the battery, manual or packaging indicates that the batteries in this product should not be disposed
of with other household waste. Where marked, the chemical symbols Hg, Cd or Pb indicate that the battery contains
mercury, cadmium or lead above the reference levels in EC Directive 2006/66.If batteries are not properly disposed
of, these substances can cause harm to human health or the environment.
SAFE USAGE GUIDELINES: Do not modify or open the product except for battery removal and replacement. Do not
disassemble or attempt to service this product. This product is safe under normal and reasonably foreseeable
misuse operating conditions. Always use both hands while operating the product. This is not a children's product
and is not intended for use by children. Product must be returned to the manufacturer for any service or repair. Long
periods of repetitive motion using the product may be associated with nerve, tendon or muscle injury in your hands,
wrists, arms, shoulders, neck or back. See a qualified health professional for pain, numbness, swelling, burning,
cramping or stiffness.
12.11 Disclaimer
DISCLAIMER
We hereby disclaim that the product is not a substitute for homeowner insurance, customers still need to purchase
relevant insurance, due to installation conditions, environment and other reasons beyond our control, we cannot
guarantee that the product/solution can 100% prevent water leakage damage in all situations, users losses will be
beyond of our liability. Ubitech assumes no responsibility for any errors that may appear in this manual. Information
contained herein and in the set-up guide is subject to change without notice.
Ubitech logo is registered trademark of Ubitech Limited
CUSTOMER SERVICE
If you have any questions, our trained Customer Service Department is happy to assist you 24 hours a day, 7 days a
week. Contact Ubitech Customer Service as follows:
Address: Flat 12, 7/F Block A, Hi-Tech Industrial Centre,
5-21 Pak Tin Par Street, Tsuen Wan, N.T. Hong Kong
Email: help@ubitech.hk
Call: +852-81008500
12.10 Warranty
STATEMENT OF WARRANTY: 1 Year Limited Warranty
Ubitech Limted ("Ubitech”) warrants to the original retail purchaser ("Purchaser”) that the Ubitech (the “Product”)
will be free of defects in materials or workmanship under use for one (1) year from the date of purchase (the
“Warranty period").
For the Purchaser only, if the Product fails to perform as specified during the Warranty Period due to defective parts
or faulty workmanship, Ubitech will repair or replace the defective or damaged parts of the Product. Normal wear
and tear is not covered nor is abnormal use, misuse, mishandling, faulty installation, improper shipping, damage
caused by disasters such as fire, flood or earthquake, neglect, accident or tampering. This warranty covers only
normal use in the United States or Canada.
To obtain warranty service during the Warranty Period, call Ubitech Customer Service + -81008500 or email: 852
help@ubitech.hk for instructions on sending damaged parts and documentation for a Return Merchandise
Authorization (RMA). Products returned to Ubitech for repair or replacement without authorization will be returned
at the sender's expense. All warranty claims must be accompanied by a legible copy of the original receipt showing
date and details of purchase.
THIS WARRANTY IS NOT TRANSFERABLE, AND, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE
LAW IS IN LIEU OF ALL OTHER WARRANTIES, REPRESENTATIONS AND CONDITIONS, EXPRESSED OR
IMPLIED, STATUTORY OR OTHERWISE, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. NO OTHER PERSON OR
REPRESENTATIVE IS AUTHORIZED TO MAKE ANY OTHER WARRANTY ON BEHALF OF UBITECH OR ASSUME
FOR UBITECH ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT. IN NO EVENT
WILL CUSTOS BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO INCIDENTAL,
SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT,
INCLUDING DAMAGES DUE TO UBITECH'S NEGLIGENCE. THIS WARRANTY GIVES YOU SPECIFIC LEGAL
RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE AND COUNTRY TO
COUNTRY.
DO NOT RETURN THIS PRODUCT TO THE STORE OR WEBSITE FROM WHICH IT WAS PURCHASED If you
believe the product is defective, has a missing or broken part or are having difficulty with it please contact Ubitech
as listed above for a quick and efficient solution to the problem.
FCC STATEMENT: This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions (1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation. This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures: Reorient or relocate the receiving antenna; increase the separation
between the equipment and the receiver; connect the equipment into an outlet on a circuit different from that to
which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
Warning: The manufacturer is not responsible for any radio or TV interference caused by unauthorized
modifications to this equipment. Such modifications could void the user's authority to operate the equipment.
Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your
authority to operate this equipment.
IC STATEMENT: This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
Contact us if you have any questions
https://www.facebook.com/
g roups/283898176125297
http://www.ubitech.hk
Facebook®
Facebook®
12.4 Operation Mode
Operation
Mode
Z-Wave
Network
Water Valve
Manual
Operation
Key Action Operation Support
Long Short Standalone Network
SmartStart Re-power up the BVS unit --- --- Support Not Support
Classic Inclusion Add into Z-Wave Mesh Network --- 3 Support Not Support
Exclusion Remove from Z-Wave Network — 3 Support Support
OTA Firmware upgrade Over The Air --- --- Not Support Support
Factory Reset Perform Device Reset Locally 10 5 Support Support
Open Control water valve to full open --- 1 Support Support
Close Control water valve to full close --- 1 Support Support
Pause Pause only works during open/close operation --- 1 Support Support
Resume Resume to previous during Pause operation --- 1 Support Support
Auto-calibration Perform calibrate position and torque force 5 5 Support Support
Trigger to close valve Auto close water valve --- 1 Support Support
Alarm Cancellation 2 --- Support Support
Resume to normal operation
mode if no alarm triggered
Water Leak
Alarm
Function Description
12.5 Network Operation & Status
Event Action / Status Key Action LED Status Buzzer Status
To be ready after Power Okay Event --- Green LED ON 2 seconds 2 beep sounds
Enter SmartStart and Processing --- Yellow LED keep blinking Keep short beep
Success --- Green LED ON 1 second Short beep x 2
Next status --- Green LED slow blinking ---
Start Manual INCLUSION Click 3 times Green LED ON 1 second 1” Pulse sound
Processing --- Yellow LED keep blinking Keep short beep
Success --- Green LED ON 1 second Short beep x 2
Next status --- Green LED slow blinking —
Start EXCLUSION Click 3 times Green LED ON 1 second 1” Pulse sound
Processing --- Yellow LED keep blinking Keep short beep
Success --- Green LED ON 1 second Short beep x 2
Next status --- Green LED slow blinking ---
Start → Triggered by Gateway --- Green LED ON 1 second 1” Pulse sound
Processing --- Green & RED LED blinking Keep short beep
Success → Waiting SOFT REBOOT --- LED OFF 10 seconds Silence 10 seconds
Next status (Power Okay→FINISHED) --- Green LED ON 2 seconds 2” Pulse sound
Start Factory Reset Yellow LED ON 1 second ---
Success --- Green LED ON 2 seconds 2” Pulse sound
Next status → Standalone Mode --- Yellow LED keep blinking ---
SmartStart
Long hold with 10
beep sounds&
click 5 times
Manual
Inclusion
Exclusion
Firmware
Upgrade(OTA)
Factory Reset
“Device Reset
Locally”