manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Ude
  6. •
  7. Microphone
  8. •
  9. Ude PZ-112 User manual

Ude PZ-112 User manual

Other Ude Microphone manuals

Ude IPU-100P User manual

Ude

Ude IPU-100P User manual

Ude PZ-510/M User manual

Ude

Ude PZ-510/M User manual

Ude MR-400/M User manual

Ude

Ude MR-400/M User manual

Ude MR-400/M User manual

Ude

Ude MR-400/M User manual

Ude IPU-100P User manual

Ude

Ude IPU-100P User manual

Ude MR-400/M User manual

Ude

Ude MR-400/M User manual

Popular Microphone manuals by other brands

Betzold 760932 operating instructions

Betzold

Betzold 760932 operating instructions

Shure A88SM user guide

Shure

Shure A88SM user guide

JTS UF-10TH/12 instruction manual

JTS

JTS UF-10TH/12 instruction manual

Shure BETA 58A User giude

Shure

Shure BETA 58A User giude

Shure SM7 user guide

Shure

Shure SM7 user guide

Sony ECM-Z200 Service manual

Sony

Sony ECM-Z200 Service manual

Electro-Voice 652 engineering data

Electro-Voice

Electro-Voice 652 engineering data

mantona 21150 instruction manual

mantona

mantona 21150 instruction manual

Loewe We. SEE 55 user manual

Loewe

Loewe We. SEE 55 user manual

IK Multimedia iRig Stream MIC PRO user manual

IK Multimedia

IK Multimedia iRig Stream MIC PRO user manual

DAPAudio RM-101 user manual

DAPAudio

DAPAudio RM-101 user manual

AKG CHM 21 User instructions

AKG

AKG CHM 21 User instructions

Sennheiser evolution wireless series EM 100 instruction manual

Sennheiser

Sennheiser evolution wireless series EM 100 instruction manual

Sony C-48 operating instructions

Sony

Sony C-48 operating instructions

GIGAMEDIA GGM PAMICUHFG user manual

GIGAMEDIA

GIGAMEDIA GGM PAMICUHFG user manual

Shure WH30TQG user guide

Shure

Shure WH30TQG user guide

auna PRO MIC-900 manual

auna PRO

auna PRO MIC-900 manual

Shure MV51 manual

Shure

Shure MV51 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

The UDEVAC system is a compact solution for voice alarm systems.
The system's features and functionalities have been designed based on the
EN54-16 standard.
The paging desk PZ-112 is part of the UDEVAC system, it enables the
monitoring and remote operation of the main functionalities of the main station
SLA-112 (alarms, emergency status, broadcasting messages; among others).
Internally, the device includes supervision for the microphone, power supply
and communication, following the safety standards assigned for this type of
applications.
The paging desk PZ-112, by using a GUI integrated within its 7'' color
touchscreen, it enables the user to browse, manage and select zones or group
zones to which messages can be broadcasted to by using the included
gooseneck microphone.
Thanks to the FTP connection and UDE's AudioLink Protocol, it is possible to
broadcast 2 different messages simultaneously from 2 different locations with
up to 1000m distance from the main station. Besides, if the distance between
the paging desk and the SLA-112 main station is lower than 50m, by using the
Direct Power technology the paging desk can be powered supplied through the
FTP cable without the need of adding any external power supply source.
Within a single installation, the system can handle up to 30 paging desks with a
configurable priority between them.
-Complies with EN54-16.
-Supervision for paging microphone.
Gooseneck's length: 300mm.
-Emergency mode and evacuation
messages activation.
-24VDC supply supervision.
-Supervision for FTP connection with SLA-112.
-Connection to up to 30 paging desks.
-Standard Paging Broadcasting per zones.
-Broadcasting of pre-recorded messages.
-Configurable priority between paging desks.
-7'' color touch screen for configuration and
operation of the system.
-Tone controls.
-XLR back connector for fireman microphone.
-Configurable Chime Push-button.
PAGING DESK WITH SUPERVISION
UDEVAC System
Engineered and made in E.U.
PZ-112
FEATURES
16
POWER +24VDC
IN OUT
AUDIO LINK
EXT
MIC
CH1 IN OKCH2 OUT FAIL
FAIL
AUDIO DATA LINK
DEVICE
POWER +24VDC
IN OUT
AUDIO LINK
EXT
MIC
CH1 IN OKCH2 OUT FAIL
FAIL
AUDIO DATA LINK
DEVICE
DESCRIPTION
73
314
185
Dimensions in mm.
PZ-112
31
610.507A
rev.1
EQUIPOS Y SISTEMAS MEGAFONÍA / INTERCOM PUBLIC ADDRESS SYSTEMS
[email protected] BARCELONA - SPAIN
Tel.: +34 934 772 854 / +34 609 914 787
EMG
SPEECH
USB
FAULT
ON
POWER +24VDC
IN OUT
AUDIO LINK
EXT
MIC
CH1 IN OKCH2 OUT FAIL
FAIL
AUDIO DATA LINK
DEVICE
6
5
4
3
2
1
8
7
9
10
12
13
11
14
15
16
18 17
LED ON. Indicates that the device is power supplied and that GUI is properly working
MICROPHONE. Gooseneck microphone. Length: 300mm.
TOUCHSCREEN. It enables management and zone selection. Besides, it shows important information of the UDEVAC System.
LED FAULT. Indicates FAULT or ALARM in the system.
LED EMERGENCY. Indicates if Emergency mode is activated in the UDEVAC system.
SPEECH PUSH BUTTON with LED. The push button must be kept pushed during the broadcasting of the message.
The LED activation indicates when the user may start the broadcasting.
LED FAIL DEVICE. If activated, it means there is a problem with the paging desk.
LED LINK FAIL. If activated, it means the communication between the PZ-112 and the SLA-112 did not succeed.
LED LINK OK. If activated, it means the communication between the PZ-112 and the SLA-112 is correct.
LED DATA OUT. This indicator shows modulation of the data which is being sent from the PZ-112 through the FTP Bus Cable.
LED DATA IN. This indicator shows modulation of the data which is being received from the FTP Bus cable.
LED AUDIO CH2. This indicator shows audio modulation from either the gooseneck microphone
or the external microphone ( XLR ) sent to channel 2.
LED AUDIO CH1. This indicator shows audio modulation from either the gooseneck microphone
or the external microphone ( XLR ) sent to channel 1.
DC BACKUP. 24VDC Batter Power supply input (Phoenix connector)
DC IN. 24VDC Power supply input from external power supply source (Ref. UDE IPW-25)
USB Port. Reserved for firmware updates.
10
16
12
14 9
11 8
13
18
AUDIOLINK. The AUDIOLINK connector enables the bus connection of the different paging desks.
Cable used must be FTP CAT.5. Connectors are RJ-45
17
MIC EXT. 5 pin XLR Connector.
Used for connection of external fireman microphone. UDE recommends model CM-23.
15
REAR PANEL
5
4
2
1
1
5
4
2
3
3
XLR
QUICK START GUIDE
CONTROLS, CONNECTORS AND INDICATORS
CM-23
24 VDC
FRONT PANEL
PZ-112
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
BLUEBLUE
BLUE-WHITEBLUE-WHITE
BROWNBROWN
BROWN-WHITEBROWN-WHITE
GREENGREEN
GREEN-WHITEGREEN-WHITE
ORANGE-WHITEORANGE-WHITE
ORANGEORANGE
1 1
8 8
EIA/TIA-568B
EIA/TIA-568B
STRAIGHT CABLE
EMG
SPEECH
USB
FAULT
ON 4
5
6
7
3
2
1
3
2
610.507C
rev.1
1 / 2
G-4 G-5 G-6
POWER AMPLIFIER
CH1
POWER AMPLIFIER
CH2
POWER AMPLIFIER
CH3
POWER AMPLIFIER
CH4
POWER AMPLIFIER
CH5
POWER AMPLIFIER
CH6 / BACKUP
CH6 ZONE
(A+B)
CH5 ZONE
(A+B)
CH4 ZONE
(A+B)
CH3 ZONE
(A+B)
CH2 ZONE
(A+B)
CH1 ZONE
(A+B)
Channel
A
Channel
A
Channel
A
Channel
A
Channel
A
Channel
A
Channel
B
Channel
B
Channel
B
Channel
B
Channel
B
Channel
B
PZ-39
FIRE ALARM
SYSTEM FIREMAN
MICROPHONE
PAGING DESK
SUPERVISED PAGING DESK
SUPERVISED PAGING DESK
MP3 / CD PLAYER
CH6 - Available without backup amplifier.
STANDARD SCHEMATIC
PZ-112
USB
DIGITAL VOICE EVACUATION SYSTEM FAULTS INDICATOR MESSAGES
STATUS
GNF SYS EVAC ALERT
EMG
DC
SIGNAL
AC
FLT/DIS
POWER
DIS
EMERGENCY
SLA-112 v.1.0
TEST
MENU
24-06-2016 13.26
ESC
OK
EMG MIC
TALK
CH1 CH2 CH3 CH4 CH5 CH6
1 MAIN STATION SLA-112 + 2 PAGING DESKS PZ112 / 6 supervised zones
Up to 32
supervised paging desks
PZ-112
PZ-112 (1)
PZ-112 (2)
CM-23
3
3
610.507A
rev.1
EMG
SPEECH
USB
FAULT
ON
1 / 2
G-4 G-5 G-6
EMG
SPEECH
USB
FAULT
ON
1 / 2
G-4 G-5 G-6
MAIN STATION
SLA-112