1-800-547-5740 • Fax: (503) 643-6322
www.ueitest.com • email: [email protected]
UTL2002
INSTRUCTION MANUAL
I n s t a l l a t i o n
1. Pull apart the two halves of the case by inserting a coin in the slot on
the bottom of the case and tw is t.
2. Feed the sensor’s wires (the end with bare wires) through the top
hole in the side of the black case and connect the wires into the
wiring terminals. No polarity on the wiring is required.
3. Connect on 9V-006P battery and fit it in place.
4. Replace two halves of the case properly.
5. To mount the case on the wall:
A. Drill two holes 50mm apart, ensuring holes are aligned
vertically.
B. Fit wallplugs and screws, but allow screws to protrude from
the wall by 3mm.
C. Place keyholes on back of the case over screws and push
down to mount.
D. If using a mains adapter instead of battery, connect to the
socket for mains adapter at the right side of the back case.
The system is now ready for use.
Operating Instructions
For Bath-Tub
1. Mount the unit over the bath-tub.
2. Adjust your desired water level (fix the sensor by pressing the
suction cap)
3. The alarm will be triggered when water is over the sensor.
For Floor
1. Take away the suction cap from the sensor.
2. Place the sensor on the flat floor.
3. The alarm will be triggered when water floods.
Testing the Battery
Test the battery condition by pressing the “Test Button”.
M a i n t e n a n c e
Cleaning and Decontamination
Periodically clean your instrument’s case using a damp cloth. DO NOT
use abrasives, cleaning solvents or strong detergents, as they may
damage the finish or affect the reliability of the structural components.
Battery
Check the battery every 2 months visually to ensure no leaks have
occurred. Leaking battery will result in poor performance and could
damage the unit.
Introduction
The UTL2002 sounds an alarm when water contacts its remote sensor. Use
it in freezers, refrigeration condensate pans, water heater containment
pans, basements, marine applications, RV’s andmuch more.
Features include
• 9 Volt battery operated
• Jack for conventional 9 Volt adapter
• Remote sensor with 7” cord
• Larger remote-sensor cord is easily added
• Suction-cup mounted sensor
• Visual (LED) and loud audible alarms
• Self test button
• Mounting hardware included
C o n t rols and Indicators
1. L ED Indicat or
2. Test Button
3. Speaker
4. Hole for Sensor Wires
5. Socket for Mains Adapter
6. Open Slot
7. Sensor
8. Suction Cap
UTL2002-MAN P. 1
1
2
34 5 6 7
On the back
of sensor
Battery
Compartment
9V
Battery
Wiring Terminal
Sensor’s Wires
Socket for
Mains Adapter
Limited Warranty
The UTL2002 is warranted to be free from defects in materials and workmanship for a period
of one year from the date of purchase. If within the warra n ty period your instrument should
become inoperative from such defects, the unit will be repaired or replaced at UEi’s option.
This warra n ty covers normal use and does not cover damage which occurs in shipment or
failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper
maintenance. Batteries and consequential damage resulting from failed batteries are not
covered by warra n ty.
Any implied warranties, including but not limited to implied warranties of merchantability
and fitness for a particular purpose, are limited to the express warranty. UEi shall not be
liable for loss of use of the instrument or other incidental or consequential damages,
expenses, or economic loss, or for any claim or claims for such damage, expenses or
economic loss. A purchase receipt or other proof of original purchase date will be required
before warra n ty repairs will be rendered. Instruments out of warra n ty will be repaired (when
re pa irable) for a service charge. Return the unit postage paid and insured to:
1-800-547-5740 • FAX: (503) 643-6322
www.ueitest.com • Email: [email protected]om
UTL is distributed by UEi
This warranty gives you specific legal rights. You may also have other rights which vary from
state to state.
UTL2002
Water Leakage Indicator
Copyright © 2007 UEi UTL2002-MAN 4/07
PLEASE
RECYCLE

Other UEi Measuring Instrument manuals

UEi C162 User manual

UEi

UEi C162 User manual

UEi DL389B User manual

UEi

UEi DL389B User manual

UEi C165-N User manual

UEi

UEi C165-N User manual

UEi EM151 User manual

UEi

UEi EM151 User manual

UEi DIGI COOL User manual

UEi

UEi DIGI COOL User manual

UEi Smart Bell PLUS User manual

UEi

UEi Smart Bell PLUS User manual

UEi C161C User manual

UEi

UEi C161C User manual

UEi DT720 User manual

UEi

UEi DT720 User manual

UEi VEI DL259 User manual

UEi

UEi VEI DL259 User manual

UEi PET1 User manual

UEi

UEi PET1 User manual

UEi DMG100 User manual

UEi

UEi DMG100 User manual

UEi DTK2 User manual

UEi

UEi DTK2 User manual

UEi DL479 User manual

UEi

UEi DL479 User manual

UEi C165 User manual

UEi

UEi C165 User manual

UEi AK940 User manual

UEi

UEi AK940 User manual

UEi K9206 User manual

UEi

UEi K9206 User manual

UEi EM151 User manual

UEi

UEi EM151 User manual

UEi C161 User manual

UEi

UEi C161 User manual

UEi C165 User manual

UEi

UEi C165 User manual

UEi SSM1 User manual

UEi

UEi SSM1 User manual

UEi M1K User manual

UEi

UEi M1K User manual

UEi DAFM4 User manual

UEi

UEi DAFM4 User manual

UEi H26-475 User manual

UEi

UEi H26-475 User manual

UEi DL469 User manual

UEi

UEi DL469 User manual

Popular Measuring Instrument manuals by other brands

ADC Prosphyg 760 Instructions for use

ADC

ADC Prosphyg 760 Instructions for use

Renishaw MH8 user guide

Renishaw

Renishaw MH8 user guide

RS PRO RSDPB5000 Series quick start

RS PRO

RS PRO RSDPB5000 Series quick start

Siemens DELTA 5TC8 425 Operating and mounting instructions

Siemens

Siemens DELTA 5TC8 425 Operating and mounting instructions

KROHNE MFC 400 manual

KROHNE

KROHNE MFC 400 manual

RIDGID micro LM-100 manual

RIDGID

RIDGID micro LM-100 manual

Converteam ALSPA MV3000e user manual

Converteam

Converteam ALSPA MV3000e user manual

Fieldpiece SSX34 Operator's manual

Fieldpiece

Fieldpiece SSX34 Operator's manual

GC CORPORATION Fuji II LC CAPSULE user manual

GC CORPORATION

GC CORPORATION Fuji II LC CAPSULE user manual

X-Rite PANTONE i1 user manual

X-Rite

X-Rite PANTONE i1 user manual

Decagon Devices ProCheck Operator's manual

Decagon Devices

Decagon Devices ProCheck Operator's manual

BEHA UNITEST TELARIS instruction manual

BEHA

BEHA UNITEST TELARIS instruction manual

Lumel ND30IoT user manual

Lumel

Lumel ND30IoT user manual

BD Sensors LMK 306 operating manual

BD Sensors

BD Sensors LMK 306 operating manual

Orphee MYTHIC 18 Service manual

Orphee

Orphee MYTHIC 18 Service manual

Contrec 515 Operation manual

Contrec

Contrec 515 Operation manual

NI PXIe-5624R CALIBRATION PROCEDURE

NI

NI PXIe-5624R CALIBRATION PROCEDURE

Rice Lake 880 Performance Series Installation

Rice Lake

Rice Lake 880 Performance Series Installation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.