2. Function and settings
2.1: Current Flow Rate
2.1.1: Power on
2.1.2: When water goes through, the display will show the dynamic flow rate;
NOTE: You need to set the K value first, please refer to 4.1 to check how to set K
value.
Default Value
Flow rate (LPM)
2.2: Total Flow Volume
2.2.1: When stop manually, the total flow volume for this section is displayed.
2.2.2: Press MENU button, the second screen will show the total flow volume from
the very beginning or from last CLEAN operation.
2.3: Quantitative Control
With the help of a solenoid valve and a hall flow sensor, US211M can fulfill this
function.
2.3.1: Power on, press SET, the Default value blinks, UPPER or LOWER button
to choose the number.
2.3.2: Press SET again to finish one number and move to the next one.
2.3.3: Press MENU to save all and esc. The Default value is set.
When the total volume reaches the Default value, the controller will shut down the
solenoid valve.
It will start again when press RUN again
3. K Value Setting
US211M flow controller is compatible with any of our hall flow sensor. The key
factor is K value.
3.1: Adjust K value
4.1.1: Power on, press MENU button 3 times, press SET for 4 seconds then the
PASSWORD blinks, UPPER and LOWER button to input 1234 as the password, then
you can adjust K value.
3.2: How to get K value.