Contents
Introduction................................................................................................................3
Graphics Display........................................................................................................4
Quick Start.................................................................................................................5
Presets.......................................................................................................................5
Running a preset....................................................................................................5
Changing a preset..................................................................................................6
Saving a preset ......................................................................................................6
Hand Shower.............................................................................................................7
Drain Operation..........................................................................................................7
Closing the drain.....................................................................................................7
Opening the drain...................................................................................................7
Main menu.................................................................................................................7
Service menu.............................................................................................................8
0% - bath calibration...............................................................................................9
100% - bath calibration......................................................................................... 10

3 2010-07-23
COPYRIGHT 2010, UNIQUE AUTOMATION
Introduction
Thank you for purchasing this quality product from Unique Automation. To enjoy the
full potential of your new product, please take time to read this guide. Having done
so, keep it handy for future reference.
bathomatic is a fully automated bath management system and shower control
designed to remove the chores of bath filling and water temperature maintenance
leaving the pleasurable part of the bathing experience.
bathomatic can be controlled by a range of interfaces and this guide covers the use
of the bathomatic Basic User Interface (BUI). Below are simple instructions allowing
users to run a bath and alter their preferences using the easy to navigate BUI with its
function/navigation buttons and graphics display.
Basic User Interface - BUI
Function buttons
Shower
Plug
Menu
Presets
Confirmation
Navigation buttons
Depth up, Menu up
Depth down, Menu down
Temperature UP, Menu right
Temperature Down, Menu left

4 2010-07-23
COPYRIGHT 2010, UNIQUE AUTOMATION
Graphics Display
When the bath is empty or BUI is not used for few minutes BUI goes into
hibernation and its graphics display goes blank. To make the system ready for use
you need to touch any function or navigation button and the graphics below will
appear indicating bathomatic status: Current bath water temperature and depth and
the last called / desired water temperature and depth.
bathomatic status:Filling - when bathomatic is filling
Paused - bathomatic filling/draining is paused1
Draining / emptying - when bathomatic is draining
Empty
Current Water Temperature - displays the temperature of the water in the bath
Current Water Depth - displays the depth of the water in the bath
Desired Water Temperature - displays the temperature value last sent to
bathomatic
Desired Water Depth - displays the depth value last sent to bathomatic
1Pressing the button during filling or draining will put bathomatic in paused status awaiting further
instructions. Pressing the button again will change status to filling and followed by the
button will change status to draining.
bathomatic status
Current Water Temperature
Desired Water Temperature
Current Water Depth
Desired Water Depth

5 2010-07-23
COPYRIGHT 2010, UNIQUE AUTOMATION
Quick Start
Touch the BUI if the graphics display is blank. The graphics display will light up
showing the current depth and temperature of water in the bath in the larger font
and in the small font on the lower right below temperature and depth the last used
desired values for temperature and depth. Should you whish to run the same
values again, just press
To increase/decrease the desired water temperature use / and to
increase/decrease the desired water depth use / . Pressing the will start
filling to the new values.
The desired values for water temperature and depth can be altered when
bathomatic is empty and is not filling or draining. Should you wish to change the
desired temperature and depth when bathomatic is filling or draining press which
will pause bathomatic, then change the values and press again for bathomatic to
resume filling to the new settings.
When the desired water temperature and depth are being changed their reading on
the graphics display move from the small to the big font type in the place of the
current values.
Presets
bathomatic stores 9 presets with individual temperature, depth and perfume
selection.
Running a preset
From the preset menu using the / buttons select the presets you wish to run
followed by the confirmation button .
bathomatic runs Preset One
Presets
Preset One
Preset Nine
bathomatic runs Preset Nine

6 2010-07-23
COPYRIGHT 2010, UNIQUE AUTOMATION
Changing a preset
To change the values of a preset press and using the / buttons select the
presets you wish to alter. Pressing takes you to the preset variables and /
navigate amongst the variables. To increase/decrease the value of a variable use
/ . The confirmation button takes you a step back into the preset and if
pressed again runs the chosen preset.
Saving a preset
Following the process above alter the variables of a preset and end the process by
scrolling to the Store preset line and using store the preset or using store the
preset and go back to the preset menu.
Temperature 38ºC
Presets
Preset One
Depth 75%
-
+
Disp: 1 0
drops
Disp: 2 0
drops
Disp: 3 35
drops
Disp: 6 0
drops
Disp: 4 0
drops
Disp: 5 0
drops
Disp: 7 0
drops
Disp: 8 0
drops
Store preset

7 2010-07-23
COPYRIGHT 2010, UNIQUE AUTOMATION
Hand Shower
bathomatic with hand shower allows a hand or overhead shower to be controlled
from the BUI. Pressing the button will display a hand shower icon with
temperature and flow bars. To start the shower adjust the temperature value to one
you desire using / and then press the repeatedly until the desired flow of
water is achieved. To turn the shower off press the once or button repeatedly
until all bars are empty and the shower stops. Exit by pressing the button.
Drain Operation
Closing the drain
BUI has a dedicate plug/drain button. When the bath is empty and the plug/drain is
open pressing the button will prompt a message ―CLOSE PLUG?‖ and to do this
you need to press the button.
Opening the drain
When the bath plug/drain is closed with an empty bath or one containing water the
pressing of the button will prompt a message ―EMPTY BATH?‖ and to do this you
need to press the button. If there is water in the bath a ―DRAINING‖ message
will appear.
When bathomatic is filing the drain cannot be open. Should you wish to open the
drain while bathomatic is filling you need to pause bathomatic by pressing the
button. When bathomatic is paused the drain functionality is enabled.
Main menu
Access the main menu by press the menu button
From within the main menu using / buttons select the option you whish to
change then use / to make the required change.
Main menu options:
Lock keyboard –cleaning or child lock
Temperature Units –Centigrade or Fahrenheit
Sleep Time –1 or 5 minutes
Service Menu
About –firmware version and service contact details
Exit by pressing the menu button

8 2010-07-23
COPYRIGHT 2010, UNIQUE AUTOMATION
Service menu
Exit the service menu by pressing the menu button
A:
2
Right arrow increments
the number
Main
Menu
Service
Menu
Service
Menu
Service
Menu
3 x
B:
3
C:
4
D:
5

9 2010-07-23
COPYRIGHT 2010, UNIQUE AUTOMATION
Right arrow increments the desired
depth D: in 10s to a maximum of 250%
FILL
Service
Menu
bathomatic will go into FILLING
bathomatic will go into PAUSED
Allow water to cover the waste and
then
SET 0%
Main
Menu
Service
Menu
Service
Menu
3 x
0% - bath calibration
The easiest and fastest way for 0% bath calibration is done by pouring water into
the bath tub with the plug closed until the water fills the cavity of the waste
completely and becomes level with the bottom of the bath tub. When the water is
level with the bottom of the bath tub let it settle for a little while then select SET 0%
in the SERVICE MENU and press to store the value.
Below is a method for 0% bath calibration using the BUI. Some practice is
necessary until you can precisely draw the right amount of water by using only the
BUI and often it is easier to draw more water than needed and adjust the depth by
manually lifting the plug until the water level is at 0%
Bath tub calibration should only be undertaken when the bath tub is in sight, and
you have easy access to the power switches supplying bathomatic and all
associated equipment. It is advisable that calibration is done prior to final
positioning of the bath panels/aprons. bathomatic can only operate reliably if it is
calibrated correctly

10 2010-07-23
COPYRIGHT 2010, UNIQUE AUTOMATION
100% - bath calibration
Different bath tubs hold different amounts of water, thus calibrating the baths 100%
depth is essential to ensure bathomatic does not overflow. bathomatic can take
any depth to be 100% thus you have to teach it your choice of 100% depth or full
bath. Typically 100% is set to at least 20mm below the point of overflow. When the
bath tub is full let the water settle for a little while then select SET 100% in the
SERVICE MENU and press to store the value. Before you attempt to SET
100% you must first SET 0%
It is strongly recommended that 100% bath calibration is made below the point of
overflow.
If 100% - bath calibration is set at the point of overflowing, due to the fluctuation of
depth reading bathomatic may never reach 100%, thus it may not stop filling should
100% fill is requested.
Right arrow increments the desired
depth D: in 10s to a maximum of 250%
FILL
Service
Menu
bathomatic will go into FILLING
bathomatic will go into PAUSED
Allow water to fill the bath to 100%
SET
100%
Main
Menu
Service
Menu
Service
Menu
3 x
—D: 000 —A:000 —r26
Top line in Service Menu
D: 000 - desired depth
A: 000 - current depth
r26 - firmware version
Other manuals for Bathomatic Basic
1
Table of contents
Popular Recording Equipment manuals by other brands

SYNQ AUDIO RESEARCH
SYNQ AUDIO RESEARCH DLP-6 Mk2 Operation manual

Texas Instruments
Texas Instruments TMS320C6000 DSP reference guide

Tascam
Tascam HS-2000 owner's manual

Yamaha
Yamaha GQ1031C Operation manual

D16 Group
D16 Group REPEATER VINTAGE MODELLED DELAY user manual

Newhank
Newhank level one user manual

Nav TV
Nav TV VOLVO-CAM 15 NTV-KIT748 quick start guide

Lexicon
Lexicon PCM 80 Service bulletin

Bias
Bias 300 Plasma operating instructions

Festo
Festo CPX-CTEL-2-M12-5POL-LK Original instructions

Pioneer
Pioneer VS-60 operating instructions

RVR Solar
RVR Solar EasyStove Installation, Usage and Maintenance Instructions