Unitronics Uni-I/O UIS-08TC User manual

Unitronics
1
Uni-I/O™ Modules
Installation Guide
UIS-08TC
Uni-I/O™ is a family of Input/Output modules that are compatible with the UniStream™ control platform.
This guide provides basic installation information for the UIS-08TC module.
Technical specifications may be downloaded from the Unitronics website.
The UniStream™ platform comprises
CPU controllers, HMI panels, and local
I/O modules
that snap together to form an
all-in-one Programmable Logic
Controller (PLC).
Install Uni-I/O™ modules:
▪Onto the back of any UniStream™ HMI
Panel comprising a CPU-for-Panel.
▪Onto a DIN-rail, using a
Local Expansion Kit.
The maximum number of Uni-I/O™ modules that can be connected to a single CPU controller is limited. For
details, please refer to the specification sheets of the UniStream™ CPU or any of the relevant Local
Expansion Kits.
Before You Begin
Before installing the device, the installer must:
▪Read and understand this document.
▪Verify the Kit Contents.
Installation option requirements
If you are installing a Uni-I/O™ module onto:
▪A UniStream™ HMI Panel; the Panel must comprise a CPU-for-Panel, installed according to the CPU-for-
Panel installation guide.
▪A DIN-rail; you must use a Local Expansion Kit, available by separate order, to integrate the Uni-I/O™
modules on the DIN-rail into a UniStream™ control system.
Alert Symbols and General Restrictions
When any of the following symbols appear, read the associated information carefully.
Symbol
Meaning
Description
Danger
The identified danger causes physical and property damage.
Warning
The identified danger could cause physical and property damage.
Caution
Caution
Use caution.
▪All examples and diagrams are intended to aid understanding, and do not guarantee operation. Unitronics
accepts no responsibility for actual use of this product based on these examples.
▪Please dispose of this product according to local and national standards and regulations.
▪This product should be installed only by qualified personnel.
▪Failure to comply with appropriate safety guidelines can cause
severe injury or property damage.
▪Do not attempt to use this device with parameters that exceed
permissible levels.
▪Do not connect/disconnect the device when power is on.
UniStream™
Unitronics
2
Environmental Considerations
▪Ventilation: 10mm (0.4”) of space is required between the device top/bottom edges and the
enclosure’s walls.
▪Do not install in areas with: excessive or conductive dust, corrosive or flammable gas, moisture or
rain, excessive heat, regular impact shocks or excessive vibration, in accordance with the standards
and limitations given in the product’s technical specification sheet.
▪Do not place in water or let water leak onto the unit.
▪Do not allow debris to fall inside the unit during installation.
▪Install at maximum distance from high-voltage cables and power equipment.
Kit Contents
▪1 UIS-08TC module
▪4 I/O terminal blocks (2 black and 2 gray)
▪
UIS-08TC Diagram
1
DIN-rail clips
Provide physical support for CPU and modules. There are two clips: one
at the top (shown), one at the bottom (not shown).
2
Inputs 0-1
Input connection points
3
Inputs 2-3
4
I/O Bus - Left
Left-side Connector
5
Bus Connector Lock
Slide the Bus Connector Lock to the left, to electrically connect the Uni-
I/O™ module to the CPU or adjacent module.
6
I/O Bus - Right
Right-Side Connector, shipped covered. Leave covered when not in use.
Bus Connector Cover
7
Inputs 6-7
Input connection points
8
Inputs 4-5
9
Input LEDs (4-7)
Red LEDs
10
Input LEDs (0-3)
Red LEDs
11
Status LED
Tricolor LED, Green/Red/Orange
NOTE
▪Refer to the module's specification sheet for LED indications.
12
Module door
Shipped covered with protective tape to prevent the door from being
scratched. Remove tape during installation.
13
Screw holes
Enable panel-mounting; hole diameter: 4mm (0.15”).
About the I/O Bus Connectors
UIS-08TC
Technical Specifications
Unitronics
3
The I/O Bus connectors provide the physical and electrical connection points between modules. The
connector is shipped covered by a protective cover, protecting the connector from debris, damage, and
ESD.
The I/O Bus - Left (#4 in diagram) can be connected to either a CPU-for-Panel, a
Uni-COM™ module, to another Uni-I/O™ module or to the End Unit of a Local Expansion Kit.
The I/O Bus - Right (#6 in diagram) can be connected to another I/O module, or to the Base Unit of the
Local Expansion Kit.
Caution
▪If the I/O module is located last in the configuration, and nothing is to be connected to it, do not
remove its Bus Connector Cover.
Installation
▪Turn off system power before connecting or disconnecting any modules or devices.
▪Use proper precautions to prevent Electro-Static Discharge (ESD).
Installing a Uni-I/O™ Module onto a UniStream™ HMI Panel
NOTE
The DIN-rail type structure on the back of the panel provides the physical support for the Uni-I/O™
module.
1. Check the unit to which you will connect the Uni-I/O™ module to verify that its Bus Connector is not
covered.
If the Uni-I/O™ module is to be the last one in the configuration, do not remove the cover of its I/O Bus
Connector - Right.
2. Open the door of the Uni-I/O™ module and
hold it as shown in the accompanying
figure.
3. Use the upper and lower guide-tunnels
(tongue & groove) to slide the Uni-I/O™
module into place.
4. Verify that the DIN-rail clips located at the
top and bottom of the Uni-I/O™ module
have snapped onto the DIN-rail.
5. Slide the Bus Connector Lock all the way to the left as
shown in the accompanying figure.
6. If there is already a module located to its right,
complete the connection by sliding the Bus Connector
lock of the adjacent unit to the left.
7. If the module is the last in the configuration, leave the
I/O bus connector covered.
UniStream™
Unitronics
4
Removing a Module
1. Turn off the system power.
2. Disconnect the I/O terminals (#2,3,7,8 in the diagram).
3. Disconnect the Uni-I/O™ module from the adjacent units: slide its Bus Connector Lock to the right. If
there is a unit located on its right, slide the lock of this module to the right as well.
4. On the Uni-I/O™ module, pull the top DIN-rail clip up and the bottom clip down.
5. Open the door of the Uni-I/O™ and hold it with two fingers as shown in the figure on page 3; then pull it
carefully from its place.
Installing Uni-I/O™ modules onto a DIN-rail
To mount modules onto a DIN-rail, follow steps 1-7 in Installing a Uni-I/O™ Module onto a UniStream™
HMI Panel on page 3.
In order to connect the modules to a UniStream™ controller, you must use a Local Expansion Kit.
These kits are available with and without power supplies, and with cables of varying lengths. For complete
information, please refer to the installation guide of the relevant Local Expansion Kit.
Numbering Modules
You can number modules for reference purposes. A set of 20 stickers is provided with every CPU-for-Panel;
use these stickers to number the modules.
▪The set contains numbered and blank stickers as shown
in the figure to the left.
▪Place them on the modules as shown in the figure to the
right.
UIS-08TC
Technical Specifications
Unitronics
5
UL Compliance
The following section is relevant to Unitronics’ products that are listed with the UL.
The following models: UIA-0006, UID-0808R, UID-W1616R,UIS-WCB1 are UL listed for Hazardous Locations.
The following models: UIA-0006, UIA-0402N,UIA-0402NL, UIA-0800N, UID-0016R, UID-0016RL,
UID-0016T, UID-0808R, UID-0808RL, UID-0808T, UID-0808THS, UID-0808THSL, UID-0808TL, UID-1600,
UID-1600L, UID-W1616R, UID-W1616T, UIS-04PTKN, UIS-04PTN, UIS-08TC, UIS-WCB1, UIS-WCB2
are UL listed for Ordinary Location.
UL Ratings, Programmable Controllers for Use in Hazardous Locations,
Class I, Division 2, Groups A, B, C and D
These Release Notes relate to all Unitronics products that bear the UL symbols used to mark products that
have been approved for use in hazardous locations, Class I, Division 2, Groups A, B, C and D.
Caution
▪This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D, or Non-
hazardous locations only.
▪Input and output wiring must be in accordance with Class I, Division 2 wiring methods and in
accordance with the authority having jurisdiction.
▪WARNING—Explosion Hazard—substitution of components may impair suitability for Class I,
Division 2.
▪WARNING –EXPLOSION HAZARD –Do not connect or disconnect equipment unless power has
been switched off or the area is known to be non-hazardous.
▪WARNING –Exposure to some chemicals may degrade the sealing properties of material used
in Relays.
▪This equipment must be installed using wiring methods as required for Class I, Division 2 as
per the NEC and/or CEC.
Certification UL des automates programmables, pour une utilisation en environnement à
risques, Class I, Division 2, Groups A, B, C et D.
Cette note fait référence à tous les produits Unitronics portant le symbole UL - produits qui ont été certifiés
pour une utilisation dans des endroits dangereux, Classe I, Division 2, Groupes A, B, C et D.
Attention
▪Cet équipement est adapté pour une utilisation en Classe I, Division 2, Groupes A, B, C et
D, ou dans Non-dangereux endroits seulement.
▪Le câblage des entrées/sorties doit être en accord avec les méthodes
de câblage selon la Classe I, Division 2 et en accord avec l’autorité compétente.
▪AVERTISSEMENT: Risque d’Explosion – Le remplacement de certains composants rend
caduque la certification du produit selon la Classe I, Division 2.
▪AVERTISSEMENT - DANGER D'EXPLOSION - Ne connecter pas ou ne débranche pas
l'équipement sans avoir préalablement coupé l'alimentation électrique ou la zone est
reconnue pour être non dangereuse.
▪AVERTISSEMENT - L'exposition à certains produits chimiques peut dégrader les propriétés
des matériaux utilisés pour l'étanchéité dans les relais.
▪Cet équipement doit être installé utilisant des méthodes de câblage suivant la norme Class
I, Division 2 NEC et /ou CEC.
UniStream™
Unitronics
6
Wiring
▪This equipment is designed to operate only at SELV/PELV/Class 2/Limited Power environments.
▪All power supplies in the system must include double insulation. Power supply outputs must be rated
as SELV/PELV/Class 2/Limited Power.
▪Do not connect either the ‘Neutral’ or ‘Line’ signal of the 110/220VAC to device’s 0V point.
▪Do not touch live wires.
▪All wiring activities should be performed while power is OFF.
▪Use over-current protection, such as a fuse or circuit breaker, to avoid excessive currents into the
UIS-08TC supply port.
▪Unused points should not be connected (unless otherwise specified). Ignoring this directive may
damage the device.
▪Double-check all wiring before turning on the power supply.
Caution
▪To avoid damaging the wire, use a maximum torque of 0.5 N·m (5 kgf·cm).
▪Do not use tin, solder, or any substance on stripped wire that might cause the wire strand to
break.
▪Install at maximum distance from high-voltage cables and power equipment.
Wiring Procedure
Use crimp terminals for wiring; use 26-12 AWG wire (0.13 mm 2 –3.31 mm2).
1. Strip the wire to a length of 7±0.5mm (0.250–0.300 inches).
2. Unscrew the terminal to its widest position before inserting a wire.
3. Insert the wire completely into the terminal to ensure a proper connection.
4. Tighten enough to keep the wire from pulling free.
UIS-08TC Connection Points
All wiring diagrams and instructions in this document
refer to the UIS-08TC connection points.
These points are arranged in four groups of seven points
as shown in the figure to the right.
Two top groups
Input connection points (0,1,2,3)
Two bottom groups
Input connection points (4,5,6,7) and power supply
connection points
Wiring Guidelines
In order to ensure that the device will operate properly and to avoid electromagnetic interference:
▪Use a metal cabinet. Make sure the cabinet and its doors are properly earthed.
▪Use shielded cables for wiring thermocouple signals and shielded twisted pair cables for wiring analog
input voltage signals;
do not use the cable shield as a signal common / return path.
▪It is recommended to short unused analog inputs (Tx- to Tx+).
▪Route each I/O signal with its own dedicated common wire. Connect common wires at their respective
common points (Tx-) at the I/O module.
▪Individually connect each functional ground point ( ) to the earth of the system (preferably to the metal
cabinet chassis).
Use the shortest and thickest wires possible: less than 1m (3.3’) in length, minimum thickness 14 AWG (2
mm2).
▪Connect the power supply 0V to the earth of the system.
UIS-08TC
Technical Specifications
Unitronics
7
▪Earthing the cables' shield:
➢Connect the cable shield to the earth of the system - preferably to the metal cabinet chassis. Note that
the shield must be connected only at one end of the cable; typically, earthing the shield at the UIS-08TC
end performs better.
➢Keep shield connections as short as possible.
➢Ensure shield continuity when extending shielded cables.
NOTE
For detailed information, refer to the document System Wiring Guidelines, located in the
Technical Library in the Unitronics’ website.
Wiring the Power Supply
This module requires an external 24VDC power supply.
▪In the event of voltage fluctuations or non-conformity to voltage power supply specifications,
connect the device to a regulated power supply.
Connect the 24V and 0V terminals
as shown in the accompanying
figure.
Wiring the Inputs
NOTE
▪Each input offers two modes: thermocouple or voltage. You can set each input
independently. The mode is determined both by wiring and by the hardware
configuration within the software application.
UniStream™
Unitronics
8
UniStream™ Uni-I/O™ Modules
Technical Specifications
UIS-08TC
This guide provides specifications for Unitronics’ Uni-I/O™ module UIS-08TC. This module comprises:
•8 Thermocouple inputs
Uni-I/O modules are compatible with UniStream™ family of Programmable Logic Controllers. They
may be either snapped onto the back of a UniStream™ HMI Panel next to a CPU-for-Panel to create
an all-in-one HMI + PLC controller, or installed on a standard DIN Rail using a Local Expansion
Adapter.
Installation Guides are available in the Unitronics Technical Library at www.unitronics.com
Inputs
Number of inputs
8
Input range (1)
Input type
Nominal values
Over/Under-range Values *
Thermocouple
type J
-200°C ≤ T ≤ 1,200°C
(-328°F ≤ T ≤ 2,192°F)
Under-range:
-210°C ≤ T < -200°C
(-346°F ≤ T < -328°F)
Over-range:
1,200°C < T ≤ 1,250°C
(2,192°F < T ≤2,282°F)
Thermocouple
type K
-200°C ≤ T ≤ 1,372°C
(-328°F ≤ T ≤ 2,501.6°F)
Under-range:
-270°C ≤ T < -200°C
(-454°F ≤ T < -328°F)
Over-range:
1,372°C < T ≤ 1,400°C
(2,501.6°F < T ≤2,552°F)
Thermocouple
type T
-200°C ≤ T ≤ 400°C
(-328°F ≤ T ≤ 752°F)
Under-range:
-270°C ≤ T < -200°C
(-454°F ≤ T <-328°F)
Over-range:
400°C < T ≤ 430°C
(752°F < T ≤806°F)
Thermocouple
type E
-200°C ≤ T ≤ 1,000°C
(-328°F ≤ T ≤ 1,832°F)
Under-range:
-270°C ≤ T < -200°C
(-454°F ≤ T < -328°F)
Over-range:
1,000°C < T ≤ 1,010°C
(1,832°F < T ≤1,850°F)
Thermocouple
type R
0°C ≤ T ≤ 1,768°C
(32°F ≤ T ≤ 3,214.4°F)
Under-range:
-50°C ≤ T < 0°C
(-58°F ≤ T < 32°F)
Over-range:
1,768°C < T ≤ 1,800°C
(3,214.4°F < T≤3,272°F)
Thermocouple
type S
0°C ≤ T ≤ 1,768°C
(32°F ≤ T ≤ 3,214.4°F)
Under-range:
-50°C ≤ T < 0°C
(-58°F ≤ T < 32°F)
UIS-08TC
Technical Specifications
Unitronics
9
Over-range:
1,768°C < T ≤ 1,800°C
(3,214.4°F < T≤3,272°F)
Thermocouple
type B
200°C ≤ T ≤ 1,820°C
(392°F ≤ T ≤ 3,308°F)
Under-range:
100°C ≤ T < 200°C
(212°F ≤ T < 392°F)
Over-range:
1,820°C < T ≤ 1,870°C
(3,308°F < T≤3,398°F)
Thermocouple
type N
-210°C ≤ T ≤ 1,300°C
(-346°F ≤ T ≤ 2,372°F)
Under range:
-270°C ≤ T < -210°C
(-454°F ≤ T < -346°F)
Over-range:
1,300°C < T ≤ 1,350°C
(2,372°F < T≤2,462°F)
Thermocouple
type C
10°C ≤ T ≤ 2,315°C
(50°F ≤ T ≤ 4,199°F)
Under-range:
0°C ≤ T < 10 °C
(32°F ≤ T < 50°F)
Over-range:
2,315 °C < T ≤ 2,370 °C
(4,199°F < T≤4,298°F)
Voltage
-70mV ≤ Voltage ≤70mV
Under-range:
-71.05mV ≤ Voltage < -70mV
Over-range:
70mV ≤ Voltage < 71.05mV
*Overflow or Underflow (1) is declared when an input value exceeds the
Over-range or Under-range boundaries respectively.
Absolute maximum rating
±36 V
Isolation voltage
Input to bus
500 VAC for 1 minute
Input to input
120 VAC for 1 minute
Input power
supply to Bus
500 VAC for 1 minute
Input power
supply to input
500 VAC for 1 minute
Conversion method
Delta-sigma
Resolution
Thermocouple –0.1°C (0.1°F) (4)
Voltage –15 bits plus sign
Accuracy (4)
(25°C / -20°C to 55°C)
Input type
Accuracy
Thermocouple type J
± 0.4°C / ± 0.7°C (± 0.72°F / ± 1.26°F)
Thermocouple type K
± 0.5°C / ± 1.0°C (± 0.9°F / ± 1.8°F)
Thermocouple type T
± 0.6°C / ± 1.2°C (± 1.08°F / ± 2.16°F)
Thermocouple type E
± 0.4°C / ± 0.8°C (± 0.72°F / ± 1.44°F)
Thermocouple type R
± 1.2°C / ± 2.4°C (± 2.16°F / ± 4.32°F)
Thermocouple type S
± 1.2°C / ± 2.4°C (± 2.16°F / ± 4.32°F)
Thermocouple type B
± 2.0°C / ± 3.8°C (± 3.46°F / ± 6.84°F)
UniStream™
Unitronics
10
Thermocouple type N
± 1.0°C / ± 1.5°C (± 1.8°F / ± 2.7°F)
Thermocouple type C
± 0.8°C / ± 2.0°C (±1.44°F / ± 3.46°F)
Voltage
± 0.05% / ± 0.1% of full scale
Noise rejection
10Hz, 50 Hz, 60 Hz, 400 Hz
Step response (4)
(0 to 100% of final value)
Smoothing
(filter)
Noise Rejection Frequency
400Hz
60Hz
50Hz
10Hz
None
310ms
470ms
550ms
2,470ms
Weak
1,236ms
1,875ms
2,195ms
9,875ms
Medium
2,470ms
3,750ms
4,390ms
19,750ms
Strong
4,940ms
7,500ms
8,780ms
39,500ms
Update time (4)
Noise Rejection Frequency
Update Time
400Hz
310ms
60Hz
470ms
50Hz
550ms
10Hz
2,470ms
Cold junction error
±1.5°C (±2.7°F)
Cable
Shielded, see installation guide for details
Diagnostics (6) (7)
Input Overflow or Underflow, sensor connection fault (6) (7)
IO/COM Bus
Bus current
consumption
80mA maximum
LED Indications
Input LEDs
Red
On: Input value is in Overflow, Underflow, or a connection
fault occurs
Status LED
A triple color LED. Indications are as follows:
Color
LED State
Status
Green
On
Operating normally
Slow blink
Boot
Rapid blink
OS initialization
Green/Red
Slow blink
Configuration mismatch
Red
Slow blink
No IO exchange
Rapid blink
Communication error
Orange
Rapid Blink
OS Upgrade
UIS-08TC
Technical Specifications
Unitronics
11
Environmental
Protection
IP20, NEMA1
Operating
temperature
-20°C to 55°C (-4°F to 131°F)
Storage temperature
-30°C to 70°C (-22°F to 158°F)
Relative Humidity
(RH)
5% to 95% (non-condensing)
Operating altitude
2,000 m (6,562 ft)
Shock
IEC 60068-2-27, 15G, 11ms duration
Vibration
IEC 60068-2-6, 5Hz to 8.4Hz, 3.5mm constant amplitude, 8.4Hz to 150Hz,
1G acceleration
Dimensions
Weight
100 g (0.220 lb)
Size
Refer to the images below
Bottom View
UniStream™
Unitronics
12
Side View
Front View
UIS-08TC
Technical Specifications
Unitronics
13
Notes:
1. The UIS-08TC measures values that are slightly higher or lower than the nominal input range
(i.e. Input Over/Under-range respectively).
Note that when input Overflow, Underflow or a connection fault occurs, it is indicated in the
corresponding I/O Status tag (refer to the UniLogic™help for details) as well as by the respective
input LED (see LED Indications), while the input value is registered as follows:
Fault Type
Registered Value in the Input Tag
Overflow
32,767
Underflow
-32,767
Connection fault
-32,768
2. For temperature measurement, the value is represented in 0.1° units. For example, a temperature
Of 12.3° is represented as 123 at the Value tag.
3. The internal cold junction accuracy is ±1°C for all thermocouple types. This accuracy adds to the
accuracy in the table. The module requires at least 30 minutes of warm-up in order to meet the
table specifications.
4. Step response and update time are independent of the number of inputs that are used.
5. See LED Indications Table above for description of the relevant indications. Note that the
diagnostics results are also indicated in the I/O tags and can be observed through the UniApps™
or the online state of the UniLogic™.
6. Sensor connection fault check is active by default for both temperature and voltage measurements.
7. Sensor connection fault check may interfere with some test equipment like thermocouple/voltage
simulators and thus may induce reading errors or cause malfunction of the test equipment and/or
the UIS-08TC.
In order to interoperate correctly with such equipment, you may set the Disable Fault Detection I/O
tag. This will disable connection fault check for all inputs.
Note that when this tag is set, the UIS-08TC will not check, or report, connection faults; thus, the
reading in such case is unpredictable.
The information in this document reflects products at the date of printing. Unitronics reserves the right, subject to all applicable
laws, at any time, at its sole discretion, and without notice, to discontinue or change the features, designs, materials and other
specifications of its products, and to either permanently or temporarily withdraw any of the forgoing from the market.
All information in this document is provided "as is" without warranty of any kind, either expressed or implied, including but not
limited to any implied warranties of merchantability, fitness for a particular purpose, or non-infringement. Unitronics assumes no
responsibility for errors or omissions in the information presented in this document. In no event shall Unitronics be liable for any
special, incidental, indirect or consequential damages of any kind, or any damages whatsoever arising out of or in connection with
the use or performance of this information.
The tradenames, trademarks, logos and service marks presented in this document, including their design, are the property of
Unitronics (1989) (R"G) Ltd. or other third parties and you are not permitted to use them without the prior written consent of
Unitronics or such third party as may own them.
UG_UIS-08TC.pdf 09/22

Other Unitronics I/O System manuals

Unitronics V200-18-E46B User manual

Unitronics

Unitronics V200-18-E46B User manual

Unitronics Vision OPLC V350-35-B1 User manual

Unitronics

Unitronics Vision OPLC V350-35-B1 User manual

Unitronics IO-DI16 User manual

Unitronics

Unitronics IO-DI16 User manual

Unitronics IO-RO16 User manual

Unitronics

Unitronics IO-RO16 User manual

Unitronics V200-18-E4XB User manual

Unitronics

Unitronics V200-18-E4XB User manual

Unitronics V200-18-E5B User manual

Unitronics

Unitronics V200-18-E5B User manual

Unitronics UID-W1616R User manual

Unitronics

Unitronics UID-W1616R User manual

Unitronics IO-DI8-RO8-L User manual

Unitronics

Unitronics IO-DI8-RO8-L User manual

Unitronics UG-ULK-EIP-4A4BP6 User manual

Unitronics

Unitronics UG-ULK-EIP-4A4BP6 User manual

Unitronics V200-18-E5B User manual

Unitronics

Unitronics V200-18-E5B User manual

Unitronics Uni-I/O UIA-0006 User manual

Unitronics

Unitronics Uni-I/O UIA-0006 User manual

Unitronics V200-18-E1B User manual

Unitronics

Unitronics V200-18-E1B User manual

Unitronics UG-ULK-EIP-4AP6 User manual

Unitronics

Unitronics UG-ULK-EIP-4AP6 User manual

Unitronics V200-18-E3XBW User manual

Unitronics

Unitronics V200-18-E3XBW User manual

Unitronics V200-18-E2B User manual

Unitronics

Unitronics V200-18-E2B User manual

Unitronics Uni-I/O UIA-0800NH User manual

Unitronics

Unitronics Uni-I/O UIA-0800NH User manual

Unitronics Uni-I/O UIS-04PTN User manual

Unitronics

Unitronics Uni-I/O UIS-04PTN User manual

Unitronics Uni-I/O UIA-0006 User manual

Unitronics

Unitronics Uni-I/O UIA-0006 User manual

Unitronics EX90-DI8-RO8 User manual

Unitronics

Unitronics EX90-DI8-RO8 User manual

Unitronics V200-18-E1B User manual

Unitronics

Unitronics V200-18-E1B User manual

Unitronics V200-18-E4B User manual

Unitronics

Unitronics V200-18-E4B User manual

Unitronics IO-DI8-TO8 User manual

Unitronics

Unitronics IO-DI8-TO8 User manual

Unitronics EX-RC1 User manual

Unitronics

Unitronics EX-RC1 User manual

Unitronics V200-18-E62B User manual

Unitronics

Unitronics V200-18-E62B User manual

Popular I/O System manuals by other brands

Mitsubishi FX2N-2DA user guide

Mitsubishi

Mitsubishi FX2N-2DA user guide

IFM Ecomat 100 CR2011 Device manual

IFM

IFM Ecomat 100 CR2011 Device manual

National Instruments PXI-7830R Getting started

National Instruments

National Instruments PXI-7830R Getting started

Moxa Technologies ioLogik E2242 user manual

Moxa Technologies

Moxa Technologies ioLogik E2242 user manual

Siemens SIMATIC ET 200AL manual

Siemens

Siemens SIMATIC ET 200AL manual

National Instruments PXIe-4480 Getting started guide

National Instruments

National Instruments PXIe-4480 Getting started guide

National Instruments NI PCI-6510 user manual

National Instruments

National Instruments NI PCI-6510 user manual

WAGO 750-438 manual

WAGO

WAGO 750-438 manual

M-system R30NCIE1 manual

M-system

M-system R30NCIE1 manual

Controlsoft CS-AC-4311 installation instructions

Controlsoft

Controlsoft CS-AC-4311 installation instructions

M-system R3-AS8 instruction manual

M-system

M-system R3-AS8 instruction manual

EasyIO 30P Frequently asked questions

EasyIO

EasyIO 30P Frequently asked questions

United Electronic Industries PowerDNA DIO-403 user manual

United Electronic Industries

United Electronic Industries PowerDNA DIO-403 user manual

Phoenix Contact AXL F CNT2 INC2 1F user manual

Phoenix Contact

Phoenix Contact AXL F CNT2 INC2 1F user manual

SeaLevel ISO-16.PCI user manual

SeaLevel

SeaLevel ISO-16.PCI user manual

Regal Marathon MD100G Series manual

Regal

Regal Marathon MD100G Series manual

WAGO 750-344 manual

WAGO

WAGO 750-344 manual

Measurement Computing PCI-DAS64/M1/16 user guide

Measurement Computing

Measurement Computing PCI-DAS64/M1/16 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.