manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Upne-Tech
  6. •
  7. Controllers
  8. •
  9. Upne-Tech LCB User manual

Upne-Tech LCB User manual

This manual suits for next models

3

Other Upne-Tech Controllers manuals

Upne-Tech SLAC-MH User manual

Upne-Tech

Upne-Tech SLAC-MH User manual

Upne-Tech Magic Series User manual

Upne-Tech

Upne-Tech Magic Series User manual

Upne-Tech SLAC-SL User manual

Upne-Tech

Upne-Tech SLAC-SL User manual

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

Savant SmartControl 2 Deployment guide

Savant

Savant SmartControl 2 Deployment guide

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

Emerson Yarway 20-55 Operating and safety instructions

Emerson

Emerson Yarway 20-55 Operating and safety instructions

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
The controller is equipped with 3 LEDs
LCB Pump Controller User Manual
Thank you very much for choosing our product. This product manual
provides important information and advice for product installation,
Before using this product, please read carefully and thoroughly
Our product has a number of safety and display functions.
The controller can be used in 12V and 24V systems has integral voltage
controller to limit the output voltage to max.of 12.0V or 24V
Max .16 mm² connector , Max safety current can reach 91A.
Self Test:
As soon as the controller is supplied with power from Panels, it starts a
self test routine. At the beginning, all LEDs flash twice, then Green LED
and Yellow LED are on.Then Controller starts to work with PWM output
for 5 seconds, then keeps output without PWM for 10 seconds. After Self
test, it continues to keep output until float switch on.if No connected to
load within 15 seconds ,the controller will be protected with red LED on.
Normally, The controller will be enabled when PV voltage rises above
14V(12V systems)/28V(24V systems). And disabled when PV voltage
downs to 11V/22V.
Controller has Automatic over current protection, low current protection
and low output voltage protection. When output current over 21A or short
circuit, or output current lower than 3A, or output voltage lower than
11V/22V, protection works with Red LED on. After 15 minutes, the
controller will retry to output..
Low Water Cut off :
The controller features a low water cut-off that will automatically cut
power to the pump when well water has been drawn down below the
pump of inlet, as well as dry-running(the controller detective output
current is 3A below, it will be dry-running)
Display Functions
12V/24V Panel @/12V Pump, No connect to orange wire to PV-
Factory default
24V Panel@24 V Pump orange connect to PV-
LED
Status
Function
Green/ Yellow
/Red LED
Flash twice
Starting work
Green LED
On
Solar array supplies electricity
Green LED
Off
Solar array does not supply electricity
Yellow LED
On
Controller Normal operation
Red LED
On
Float Switch on, Tank full
Over current(21A above) or short
circuit,or output current lower than
3A or No connected to load, After
fifteen minutes, Retry to output
Always Yellow Wire connect to the float switch wire, The other
float switch wire connect to the negative PV, the negative PV connected
to be grounded. If there is no float switch, please ignore the yellow wire
connection .
When the controller output power is low ,Please consider to add
lengthen the pipe of the pump until the input power and output power
are close.
When the rated current of the water pump exceeds 16A, the controller
needs to be fixed on a heated metal so that the controller can better
dissipate heat, otherwise it will cause thermal protection.
2
Solid LCB Technical Characteristics
Subject to change without notice.Jay.mo@upnetech.com
Version: 2021-09-19 www.upnetech.com
Model
LCB 14A 16A 20A
Rated system voltage
12V/ 24V
Max.load current
14A 16A 20A
Maximum output voltage
12 V(12V System) 24V(24V System)
Start up Input-voltage
14V/28V
Under panel voltage
protection.
11V/22V
Max. Input Panel voltage
55V
Reverse polarity
Protected
Short circuit/Over current
Protected(Less than 3A,More than
21A )
Efficiency
>98%
Dimensions (WxHxD)
140mm*72mm *40mm
Installation dimensions
130mm*66mm
Max. wire size
Max 16mm²
Ambient temperature
-40°C-+40°C
IP grade
IP22
Altitude
≤4000m
Net weight
340g