UR FOG COMPACT 390 User manual

COMPACT
390
INSTALLATION AND USER MANUAL
Installation and use manual model COMPACT rev. 01 Dec 2023 page 1 of 20
ENGLISH MANUAL

WARNING!
All UR FOG fogging systems should only be used with UR FOG-branded fluids.
It is strictly forbidden to use any fluid not previously authorized in writing by UR FOG srl.
01 PACKAGE CONTENT
Inside the package you will find:
1. A fogging machine COMPACT 390 model
2. One 500 ml fluid bag (also shipped in separate cartoon)
3. A window sticker to indicate the device installation
4. Installation and use manual
01 Package contents page 2
02 Product presentation page 3
03 Conditions of use and warnings page 3
04 Installation tips to install fogging systems page 4
05 Technical specifications and battery endurance/backup page 5
06 Preparation to the installation page 5
07 Electrical power supply page 6
08 Power supply connection page 7
09 Input / output description and connections page 7
10 Connection examples page 9
11 Shooting time setting page 11
12 Fluid bag installation, exchange and reset page 13
13 Front LEDs meaning page 14
14 Maintenance page 15
15
Reset from fault condition
page 17
16 Faults and possible solutions page 16
17 Warranty and conditions of use page 18
18 Maintenance and operations page 19
The conditions of use will be automatically accepted by breaking the security labels on the product.
SUMMARY
2

02 PRODUCT PRESENTATION
Thank you for purchasing a UR FOG product
The great technological innovations such as the fluid injection system, the disposable bag, the ecological and economic
system for the complete emptying of the bag, together with the heating system, make the COMPACT fogging systems the
best performing devices in the security market.
- Simple: machine easy to install and able to be integrated to any existing alarm system.
- Small: the COMPACT size of the unit allows installation in any places.
- Green: the lowest power consumption among fogging systems .Ready to generate fog in minutes.
03 CONDITIONS OF USE AND WARNINGS
The fog generated by UR FOG COMPACT does not create problems or injuries to people during a short stay in a room filled
with fog, if the system is used according to the manufacturer’s recommendations.
The generated fog is certified as safe for people and animals from an authorized international certification body and it is
proven that it does not leave any residual.
UR FOG COMPACT unit , as the fluid used to generate fog , is certified respecting european laws and regulations.
Any certifications required in specific countries are a responsibility of the distributor of that specific country.
It is not guaranteed by the manufacturer the use of UR FOG system in the presence of objects that may be damaged anyway
by the contact with substances based on glycol, water and alcohol.
Any employee or worker that may be exposed to fog must be warned in advance and must be checked for any allergy to
the substances listed above.
At the date of printing of this manual it has never been pointed out any problem related to any allergy.
UR FOG is in no way responsible for any damage or condition of use that has not been required and specifically approved by
any specific written request prior to the installation of its products.
For fog fluid please refer to UR FOG fluid safety data sheet published on the website and carefully read it at www.urfog.com.
Contact a doctor if for any reason you swallow fog fluid or if after contact with eyes or skin you have any kind of reaction,
and in any case wash it immediately with water and soap.
Do never stay for a long time in a room filled with fog.
Do not use charged bags that are not the ones suggested by UR FOG and never try to recharge them, they are made for a
single use.
Follow your national rules for the dispose of empty bags. Keep UR FOG bags out of reach of babies and animals.
The nozzle may be hot and touching it may cause burns. Do not look directly into the nozzle.
Never use UR FOG products for any purpose that is not related to protection from thief or robbery (the choice of the
conditions of use in case of robbery will be suggested by your security consultant). Never use different fog fluids or add any
other substance into the bags.
Do not use or keep charged UR FOG machines in vehicles and do never transport UR FOG before 24 hours since it has been
shut off.
During transport the device must be switched off.
3

04 INSTALLATION TIPS FOR FOGGING SYSTEMS
Please observe the following instructions for installing UR FOG COMPACT:
1. This appliance is not intended for use by person (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
2. Children should be supervised to ensure that they do not play with this appliance.
3. The machine must be installed avoiding to obstruct escape routes.
4. Verify the fog does not limit the visibility near: stairs, landings, moving objects that may cause falls, injuries or any
damage to persons.
5. When using the product in multi-storey buildings, if the escape route runs through an area which is protected by a
fogging system, it is recommended to install a vocal warning that provides instructions on the behavior to observe.
6. Do not look directly into the nozzle. Do not add any other substance into the bags.
7. The nozzle may reach high temperatures, touch it may cause burns.
8. When UR FOG COMPACT 390 generates fog avoid staying closer than 1 meter from the device.
9. Report its installation to the firefighters in your area and to other institutions if needed. It is suggested to do it before
testing the unit to avoid false alarms.
10. Remember to put windows sticker(s) reporting the presence of UR FOG on the entrance.
11. It is necessary to add an external switch to separate the fog generator from the alarm system and it should be
activated before the maintenance to avoid that, for example, maintenance tests can activate the fog generator.
12. Never direct the fog flow towards an object or a wall less than 2 meters away.
13. Before setting installation, consider that COMPACT 390 may reaches and exceeds more than 10 meters away in the
first 3 seconds from the point where the machine is installed.
14. Setting the shooting time interval between the minimum and maximum shown in the shooting table,
avoid “overshooting” even if the produced fog is dry and generally doesn’t leave residue.
A shot that goes far beyond the recommended seconds can create a residue or even drops in the room.
15. Install at an height of about 2,5 meters not to let it be reached, avoiding possible tampering.
16. Do not move the machine when it is still hot.
17. The main body of COMPACT 390, which has the heating system enclosed inside a metal frame, should not be opened
unless by specific and authorized service centers. Do not open and touch for any reason the insulation before
24 hours the unit has been shut off. The internal part may still be at very high temperature.
18. Do not activate the COMPACT 390 fogging system before the installation is completed.
19. Insert the fluid bag as the last procedure and remember to verify the anti-tampering functions, if any.
20. When the installation is finished, always perform a trial shot to test the system.
21. Install COMPACT 390 on a wall or deskstand avoiding any obstacles in front of it which can prevent the spreading
of the fog.
22. Wiring unit to mains power, remember that the tip of a stranded conductor should not be soft-soldered where
the conductor is subjected to contact pressure.
23. The COMPACT 390 fogging system should not be exposed to water spray or dripping.
The unit is designed for indoor use.
24. The content of the bags is mechanically predetermined and can be subject to variations +/- 10%.
4

05 TECHNICAL SPECIFICATIONS
The red led ON related with the “empty” signal shows that the unit needs to be refilled, even if fluid for a
full shot is still available.
It is recommended to always have available a new refill and to proceed to replace it as soon as possible.
Weight without bag
Max fog emission in a single shot
Total fog emission capacity with full bag
Fog bag capacity
Working time without mains power
Max power on heating system
Average power consumption during heating
Heating time
Average power consumption
Maximum current consumption at 12 V
Battery type (not included)
Door tamper
Anti-tear off and anti-shift
3,8 Kg
130 m3 (visibility < 1 m)
Around 850 m3
1 x 500 ml
Around 1 hour
300 W
300 W
Around 20 minutes
32 W
1,2 A
Pb 1.2 Ah 12V
n/a
n/a
*Industrial standard as from
other manufacturers
COMPACT 390
It is always recommended to secure the fog generator to a wall even when it is placed on a flat surface.
The optional mounting kit for COMPACT 390, mainly recommended for ceiling installation, include both battery and fluid
bag holders. An optional orientable (pan & tilt) module is available for wall mounting, it can also simplify standard
installation by allowing to use back holes for the passage of cables.
Always verify that the bracket or the support surface are suitable for the weight of the machine.
It is suggested not to install the machine behind walls in a limited closed area without a specific ventilation, in order to
prevent a possible overheating .Always verify that for Compact 390 ceiling/horizontal installation the temperature of the
rooms doesn’t exceed 40°C. To avoid injuries please securely fix the fogging machine to the wall according to the
installation instructions.
After removing the machine from the package, unscrew the side four screws of the plastic front panel. Remove the front
panel and uncover the electrical circuit (hereinafter referred to as PCB), the DC12V power supply, the thermal unit
and the fluid bag. (Fluid bag can also be shipped outside the unit).
06 INSTALLATION
-Do not disconnect the machine immediately after the shot
-Change the battery every two years
-Change the bag as soon as the “empty” signal appears
-The generator cannot be activated on a surface that does not allow air circulation from side slots
WARNING:
5

07 ELECTRICAL POWER SUPPLY
The 230V input provides primary power to the heat exchanger and, by the use of a switching power supply, to the electronic
board and the pump. The heat exchanger’s working time without mains power ensures proper functioning for a certain
period of time, usually around one hour, even in complete absence of mains power.
The functioning of the electronic part and the pneumatic system is guaranteed by the 12V 1.2A battery (not included).
Although the heating element is of 300W, the average power consumption is between 30W and 50W on normal operation.
Do not use inverter or UPS if you are not sure that are designed to generate a pure sine wave.
Square wave or rebuilt sine wave are not suitable for the device. Please ask to the UPS manufacturer
the correspondence of such feature before proceeding with mains power connection.
- The max current to be considered for the device is 2A
- The connection to the 230V or 110V electricity grid must be performed by a qualified technician.
- Connect the equipment to the electricity grid only after installation is completed.
- It is necessary to connect the ground terminal.
- The system must be connected to the mains through an automatic switch (automatic switch, curie C,
with Ih= 10 A and Idif= 30 mA,...) with breaching capacity based on the assumed fault current of the fogging
system in the sampling point.
IF FOR ANY EVENIENCE IT IS NEEDED TO REPLACE THE FUSE, USE ONLY FUSE WITH THE SAME
SPECIFICATIONS AS THE ONE INSTALLED.
EXAMPLE FOR 230v Model: Timed Fuse 250v H Type (1500A) CERAMIC BODY FILLED WITH QUARTZ,
REF. STD. EN60127-2-3/DIN41660 3,15AH (EXAMPLE OMEGA GT520231)
EXAMPLE FOR 120v Model: Timed Fuse 250v H Type (1500A) CERAMIC BODY FILLED WITH QUARTZ,
REF. STD. EN60127-2-3/DIN41660 6,3AH (EXAMPLE OMEGA GT520263)
PLEASE NOTE THAT, AS ALL POWERED EQUIPMENT FROM THE ELECTRICITY GRID REQUIRING INSTALLATION,
IT IS SUBJECT TO COMPLIANCE WITH RULES OF THE COUNTRY IN WHICH IT IS INSTALLED
While connecting the machine to the mains power,
it is recommended to carefully care the connections
and the screwing of the terminal block screws.
Disconnecting or modifying the ground cable voids
the warranty and can generate faults related to
the temperature control.
Note: always check the unit AC voltage is
corresponding to the mains power available in your
country.
Different models are available for 120v AC and
230v AC mains power.
NEVER connect the unit to mains power if voltage
doesn’t match.
N L
6

09 DESCRIPTION OF INPUT AND OUTPUT CONNECTIONS
08 POWER SUPPLY CONNECTION
- The battery installation is essential for
the safe use of the device, it is monitored
and recharged by the board’s circuit.
- The housing for the 1.2A 12V lead-acid
battery is lodged on right side of the
exchanger.
- To gain access to the battery it is
necessary to remove the plastic front
panel and metal side battery holder
screws (horizontal ceiling installation).
12V Power supply connection
230V Power supply connection
230V Mains power
Ground connection
Battery slot (battery not included)
1
2
3
4
5
5
1
2
Connection PIN description
DC12V Power supply OUTPUT
1 + DC 12V Output (max 200 mA)
2 - 0V DC ground connected
OUTPUTS
3 ARD / SHP
4 EMPTY
5 ERROR
INPUTS
6 - GND
7 ARM Arming input
8 TRIG Shooting input
Note: both inputs accept dry contacts
toward GND.
34
N L
1 2 3 4 5 6 7 8 J10
7

OUTPUT Power DC12 V
1-2 Output DC12v (max 200mA) for electrical connection of local devices connected to the board.
It can be used to power a local PIR or a remote receiver. It is recommended not to overload the output.
OUTPUTS
3 ARD/SHP - Reports the ARMING status (W2 open), or is active when TRIG is in progress (W2 close).
4 EMPTY - reports the fluid EMPTY condition.
5 ERROR - reports a transient error or fault condition that voids functionality.
It also activated when maintenance is needed, eg. faulty battery , mains power fault or detected temperature out of range.
If a mains power fault occurs it will be self resetted when correct mains power is back. We remind that it is necessary to
connect this output to an alarm control panel or other equipment able to forward the signal to whom is concerned.
INPUTS
6 GND Reference GND for the inputs.
7 ARM Closing the contact ARM: the blue led turns ON and then, if the unit has reached the correct temperature,
ready to generate fog. During the shot, if the contact ARM is opened, it immediatly stops fog generation.
8 TRIG Closing the contact TRIG, if the unit is armed and has reached the correct temperature,
it generates fog for the time set.
After the shot, all further shot commands within 120 seconds will not be processed.
In order to avoid accidental activations with consequent fog emission, the inputs are in "negative safety",
so the disconnection of a wire does not cause their activation.
It is essential to carefully check the reliability of the connections and protect the cables to the alarm control unit where
there is a risk of accidental or malicious damage.
A) J4 Mains power connection
B) J5 Heater Resistor
C) J2 Thermal CutOff
D) J7 Power supply unit 230v AC/12v DC
E) J9 Battery 12v 1.2A connector
F) J8 Thermal Sensor connector
G) J10 Inputs/Outputs connector
H) J11 RS232 port 1 connector
I) J6 RS232 port 2 connector
J) J3 Fluid Pump Connector
L) J1 USB port
M) F4 Mains fuse
W1 Shooting time setting enable
W2 Reserved (Open)
W3 Reserved (Open)
GH
F
E
D
C
B
W1
I
W3
W2
L
M
N L A
8

10 CONNECTION EXAMPLES
The diagrams and examples below are intended only for a “better understanding” of the operation
of the inputs / outputs. None of the diagrams below represents the “single scheme to perform” as,
in respect of the reference standard EN50131-8:2019, there are precise indications and only using
all inputs and outputs on the PCB it is possible to abide by the standard.
Is recommended to use the “HOLD-UP” function after a careful evaluation of the risks from a
security consultant.
When COMPACT is ARMED, it becomes immediately ready to create fog.
For safety reasons and to avoid false fog emissions is suggested to program the alarm panel to
allow enough time to leave the place.
The ON/OFF output of this alarm panel is an Open Collector NPN that is OPEN with the alarm OFF and close to
negative for all the time the alarm panel is active and monitoring.
The alarm panel output is normally open and close the contact during alarm time.
A COMPACT inputs connected to standard alarm panel outputs
B COMPACT inputs connected with a clean contact (relays) alarm panel outputs
C Wiring example of COMPACT outputs to drive leds and/or relays
Note: in the following examples the output signal ARD/SHP has the following meaning
depending on jumper W2:
W2 OPENED=ARM STATUS reported
W2 CLOSED=SHOT in PROGRESS STATUS reported
A - COMPACT inputs connected to standard alarm panel outputs
J11
J10
Alarm system panel
NPN output
Open Collector
OC1 NO BISTABLE
OC2 NO MONOSTABLE
OC
OC
GND
S1
81
TRIG
ARM
ARD/SHP
EMPTY
FAULT
GND
9

The ON/OFF output of this alarm panel is an open relay when panel is OFF that continuosly keep close for all the time
the alarm panel is monitoring.
The alarm output of the panell is an open relay that close when alarm condition is detected.
B - COMPACT inputs connected with a clean contact (relays) alarm panel outputs
C - Wiring example of COMPACT outputs to drive leds and/or relays
TRIG OUT
+
-
ARM OUT
+
-
J11J10
TRIG
ARM
LED
RELAY TRIG
+
-
CO
NO
NC
LED
RELAY ARM
+
-
CO
NO
NC
ARD/SHP
EMPTY
FAULT
GDN
S1
81
TRIG
ARM
ARD/SHP
EMPTY
FAULT
GND
J11J10
LED
+
-
CO
NO
NC
S1
81
TRIG
ARM
ARD/SHP
EMPTY
FAULT
GND
10

11 SHOOTING TIME SETTING AND FOG FLOW DIRECTION
To set the shooting time, after opening the front panel, you must CLOSE the jumper W1 in SET position then, holding down
the button S1, the green led on the front will flash and each flash is equivalent to one second fog emission.
If you press the button again, the shooting time is not added to the one previously set, but will restart from zero.
If S1 button is pressed for a time longer than the shooting time allowed for the unit, shooting time will be set to the
maximum possible. Shooting time can be set according to desired seconds, but to correctly activate pipes refill in full
security, it must be set to minimum 2 seconds. After setting the shooting time, to avoid wrong time settings,
is suggested to keep the W1 jumper OPENed.
In order to select the needed notification, customer can personalize the output signal as follow:
W2 OPENED = ARM STATUS – ACTIVE unit is armed – OFF unit not armed (DEFAULT).
W2 CLOSED = SHOT STATUS – ACTIVE unit is performing a shot – OFF no shot in progress.
W2
W1
J11
J10
SET TIME
RESET
S1
TRIG
ARM
ARD/SHP
EMPTY
FAULT
GND
1 8
11

13 (39*)
26 (78*)
39 (117*)
52 (156*)
5
10
15
20
65 (195*)
78 (234*)
91 (273*
104 (312*)
25
30
35
40
117 (351*)
130 (390*)
45
50
m³
to protect
Seconds
of emission
m³
to protect
m³
to protect
Seconds
of emission
Seconds
of emission
SHOOTING TABLE COMPACT 390 (max 50 sec.)
* Industrial standard as from other manufacturers
The value in the first column indicates the volume of the room to be protected, with respective seconds of emission reported in the second
column. The value in m³ varies depending on the density to be obtained. With the suggested value it is possible to get the maximum
density recommended to ensure the absence of any residual. In places where a little residual causes no problems, it is possible to increase
the shooting time. Please note that the more fog released, the more the time required to recover visibility. High levels of fog, over
recommended limits, can leave residual. Any residue usually goes away by itself within 24/48 hours, otherwise, being soluble in water,
it is enough to use a wet cloth for cleaning. If you desire to obtain an average of 1 meter visibility after 60 seconds, as specified by the
standard EN 50131-8:2019, as used as reference by all manufacturers of fog generators, the number of shooting seconds it is to be
reduced in half.
RECOMMENDED SHOOTING SECONDS ACCORDING TO THE VOLUME SPACE TO PROTECT (m3)
Fogging systems COMPACT 390 is able to produce fog based on second by second setting.
The maximum quantity of 1,5 ml/s allows to fill an area of about 150 cubic meters.
There might be cases in which, due to specific characteristic of the location, nozzle type, levels of temperature and air
pressure, degree of the fog density and light in the target area, the shooting time can be increased or decreased.
For example, above 3mt of height the shooting time must be integrated and above 5mt, every additional meter should be
considered as double.
HxLxP-------- Height x Width x Depth of the area to protect
D------------- Density of the produced fog
V------------- Temperature and air pressure
R------------- Acceptable residue in case of saturation of V parameter
I-------------- Intensity of the surface light
(HxLxP) x D x V x R x I
The following tables indicate the suggested fog emission in relation to the number of seconds of shooting set in average
condition of temperature, air pressure and humidity.
To correctly dimension the machines it is needed to verify that the saturation of the area occurs in faster time than
the one supposed for the theft.
On the UR FOG Compact 390 mainboard are present two serial ports connectors (J11 and J6) that are reserved for
connection to expansion modules and communication devices specially designed by the manufacturer.
To allow advanced diagnostics, it is possible to connect a personal computer with Microsoft Windows or Linux operating
system using a microUSB cable to the J1 port. Using a generic terminal emulator it will be possible to display
the operating parameters of the device on the screen. The same port can be used for any firmware updates of
the device. We recommend that you refer to your product distributor for more information about advanced diagnostic.
12

12 INSTALLATION, EXCHANGE AND BAG RESET
Insert the bag in place as show in picture.
Metal plug
Insert a new bag and push metal connector till a “click” is heard.
13

13 FRONT LEDS MEANING
Metal plug
Press button S1
RED LED (right)
ON: Error (Mains power off / Battery low) or Fault.
Blinking: Empty bag or low fluid.
OFF: No error condition.
EMPTY
RESERVE
ARM
HEATING
BLU LED (center)
ON: Unit is armed and ready to shoot (if green led is already ON).
OFF: Unit is disarmed, shot not possible.
GREEN LED (left)
ON: Unit has reached the correct temperature.
Blinking: Unit is warming, no shot possible.
OFF: Device fault.
The EMPTY signal also means that fluid is going LOW.
It means that the unit has shot at least 100 seconds since last reset (COMPACT 390).
The central RED low power light means unit is correctly powered on.
14

14 MAINTENANCE
UR FOG fogging systems don’t need special maintance, nevertheless is suggested a periodical check to the following
parts by skilled operators:
1) Verify battery and power supply status.
2) Verify screws are firmly closed.
3) Verify the output nozzle is not damaged and without anyting inside.
4) Verify pneumatic circuit.
5) Verify once a year liquid pump.
BATTERY AND POWER SUPPLY CHECK
Verify that the output of the power supply without any load (battery unplugged) is 14,1 V on the PSU.
If a different value is noticed, set the trimmer on power supply.
Verify battery status (integrity check, no overheating); is suggested to replace the battery on 2 years base due to the heavy
load during shots without mains power.
SCREWS
Verify that all fixing screws are correctly setted and eventually rescrew them.
OUTPUT NOZZLE
Verify that ouput nozzle is not damaged and that there is nothing inside blocking the fog ejection flow.
YEARLY PUMP FUNCTIONALITY TEST
The test is done executing a trial shot on the unit. To avoid creating too much fog during the test is suggested to stop
the flow after a few seconds dearming the unit under test.The fog flow will immediatly stop.
15 RESET FROM FAULT CONDITION
Disconnect the units from any power source, both mains power and battery must be disconnected.
Wait 5 minutes and reconnect the battery and mains power.
This procedure helps to understand if the fault condition was due to mains power overload, serious power supply problems
or problems in thermal loop.The fault condition is shown by the RED led ON (LED DL4 on the top), the output FAULT
immediately switchs and can indicate a transient or fixable condition (Eg. low battery power or no mains power),
or a problem that cannot be fixed on site.
On mains power fault or battery low conditions the unit will recover itself without any further operation on it.
In the evenience that the mains power fault has generated further problems to the unit (Eg. on board fuse) or that the
backup battery is not working anymore, the maintenance is needed.
Note: The RED led (LED DL1, middle of the board), means that unit is ON. It is NOT a fault condition.
15

Small fog flow coming out
from nozzle
Too low battery level or
exaust
Bag in Reserve or
Empty
No Mains power
Disturbance / interference
or potential differences
between devices
This condition is normal and can happen on first
installation, it will completely disappear in a while
when the unit will become completely hot.
Replace Battery
Error on thermocouple, fuse cable, resistor.
Please refer to technical service
Check mains power or F4 fuse
In the evenience of high noise on mains power
(lightings) an error while reading thermocouple
values can occur.
Execute recovery (Paragraph 16).
If even recovery fails the unit may be faulty
In very large installations or with more than one
fog units connected to the same alarm panel,
a mains power difference can occur,
in that evenience the units have to be decoupled.
Replace fluid Bag
Switch off the unit and verify the screw on J8
connector
Error in the thermal loop
Heater Temperature too high
or thermocouple error
RED Led ON (Fault)
All products are 100%
and a small ammount
of liquid could be still in
the warming unit.
Switch off the unit and clean air holesPoor ventilation
RED Led ON (Error)
DEFECT FOUND POSSIBLE CAUSE POSSIBLE SOLUTION
16 DEFECTS POSSIBLE SOLUTION
16

Unit ARMED
(BLUE LED ON)
but don’t execute
trig command
Red front led BLINKING
Green front led is BLINKING
Wires error
Mains power overload
Electronic Board overheath
Bag changed, reset needed
Follow instructions Paragraph 13
Empty bag - replace it following instructions
on Paragraph 13
Unit still warming, wait max 60 min. with the unit
connected to the mains power
Refer to bag Reset (Paragraph12)
and shooting time setting (Paragraph 11)
Warning:
please verify/set again the shooting time.
Try the Recover procedure (Paragraph 16)
With no results replace the board
Power off the unit and verify air flow near the unit
(Paragraph14)
Verify on J10 that when alarm activates there is
a contact between - GND (6) + ARM (7)
Verifify on J10 that when alarm is ON there is a
contact between - GND (Pin 6) + TRIG (Pin 8)
See time setting (Paragraph 11)
Wires error
The W1 jumper is OPEN,
unit in’ “RESET” mode
Unit cannot be ARMED
BLU LED OFF
While setting shooting time
the green LED lights once
DEFECT FOUND POSSIBLE CAUSE POSSIBLE SOLUTION
17

17 WARRANTY
The warranty of COMPACT 390 is two years and is handled directly from the dealer or authorized installer, so
please contact your supplier to take advantage of warranty with the copy of the purchase document that contains
the serial number of the machine. Not included in the warranty: moving parts and/or damages depending on the
incorrect use unless it is found a manufacturing defect in origin. Liquid and bags are not covered by warranty.
BY BREAKING THE SECURITY LABELS AND THE OPENING OF THE MACHINE YOU WILL ACCEPT
WHAT IS WRITTEN ON THIS MANUAL AND ON THE WEB SITE: www.urfog.com
We recommend to throw away the batteries in the appropriate waste containers
for recycling. Heavy metals contained in them are recyclable.
UR Fog srl: Via Toscana n. 38 - 10099 San Mauro Torinese - Italy
Phone +39 011/01.33.037 - Fax 011/01.33.005
Legal office: Via Giacinto Collegno 11 - 10143 - Torino - Italy
RESELLER/INSTALLER STAMP
(company to contact for the warranty)
Serial number
Date of installation
Signature of installer
At the end of the installation, write down the identification number of the machines,
the date of the installation and sign in the dedicated spaces.
18

18 MAINTENANCE
DATE
BATTERY EXCHANGE
BAG EXCHANGE SIGNATURE
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
YES NO YES NO
It is mandatory to fill out this table in accordance with the security rules
19

N.B. Ask for the PDF module
TO USE UR FOG FOGGING SYSTEMS WITH PURIFOG
FLUIDS FOLLOW THE DATASHEETS INSTRUCTIONS
AVAILABLE FOR DOWNLOAD ON WWW.PURIFOG.COM
UR FOG S.r.l. Via Toscana 38 - 10099 San Mauro Torinese - Italy