manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. US Balance
  6. •
  7. Scale
  8. •
  9. US Balance US-ORBIT-PRO User manual

US Balance US-ORBIT-PRO User manual

Other US Balance Scale manuals

US Balance US-TORPEDO User manual

US Balance

US Balance US-TORPEDO User manual

US Balance US-VELOCITY Quick reference guide

US Balance

US Balance US-VELOCITY Quick reference guide

US Balance US-TRADER-PRO 3Kg User manual

US Balance

US Balance US-TRADER-PRO 3Kg User manual

US Balance US-TT-1000 User manual

US Balance

US Balance US-TT-1000 User manual

US Balance US-Storm Quick reference guide

US Balance

US Balance US-Storm Quick reference guide

US Balance US-750EX User manual

US Balance

US Balance US-750EX User manual

US Balance US-BENCHTOP-PRO User manual

US Balance

US Balance US-BENCHTOP-PRO User manual

Popular Scale manuals by other brands

KERN MCC-M operating instructions

KERN

KERN MCC-M operating instructions

Little Balance SB MECA 8113 user manual

Little Balance

Little Balance SB MECA 8113 user manual

Fitbit Zip Aria Wi-Fi Smart Scale user manual

Fitbit Zip

Fitbit Zip Aria Wi-Fi Smart Scale user manual

KERN MPU 250K100 operating instructions

KERN

KERN MPU 250K100 operating instructions

Steinberg Systems SBS-PF-200 user manual

Steinberg Systems

Steinberg Systems SBS-PF-200 user manual

Total TP2000 user guide

Total

Total TP2000 user guide

A&D HL-200i operating instructions

A&D

A&D HL-200i operating instructions

OHAUS Courier 3000 user guide

OHAUS

OHAUS Courier 3000 user guide

Scarlett SC-KS57P97 instruction manual

Scarlett

Scarlett SC-KS57P97 instruction manual

BASETech LS-40S operating instructions

BASETech

BASETech LS-40S operating instructions

SR Instruments SR Scales SR565i-H Operating and service manual

SR Instruments

SR Instruments SR Scales SR565i-H Operating and service manual

Gallet PEP 301ART instruction manual

Gallet

Gallet PEP 301ART instruction manual

AWS ZEO-50 user manual

AWS

AWS ZEO-50 user manual

Gima Glass Body Fat Analyzer Use and maintenance book

Gima

Gima Glass Body Fat Analyzer Use and maintenance book

Seca 374 user manual

Seca

Seca 374 user manual

EDLUND BBPZ-20 quick start guide

EDLUND

EDLUND BBPZ-20 quick start guide

TEC TEC SL59 SERIES owner's manual

TEC

TEC TEC SL59 SERIES owner's manual

Alecto ACW-40 user manual

Alecto

Alecto ACW-40 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

`
US-ORBIT-PRO – User Manual
Precision Tabletop Scale
Capacity: 2000g x 0.1g - Weighing modes: g, oz, ozt, dwt
Thank you for purchasing US-ORBIT-PRO Precision Table Top Scale.
Please read all operation instructions carefully before use.
All items included with this package
SPECIFICATIONS
Max capacity:2000g
Resolution: 01g
Weight units: g, oz, dwt, ozt
Stainless steel platform
Operation temperature: 0~40°C
Green and blue back light Auto Changing
Memory function / indication: M
Counting function / indication: C
Low battery indication:
Protective cover / container
Overload indication: EEEEEE
Power supply: 4 x AAA batteries
Auto oft around 40 seconds if no operation
CONVERT WEIGH WEIGHT UNITS
Press ‘CAL/MODE’ KEY once at a time to select unit in the order of: g > oz > dwt >
ozt > rEF 5 > rEF10 > rEF20 > rEF50 > g
TO WEIGH
1. Place the scale on a firm, flat surface.
2. If using bowl or any other container, place container on platform after
turning on scale. Then press TARE/PRINT key to zero reading.
3. The scale weighs in grams, ounces, dwt or ozt. Select your preference with
the Cal / Mode button.
4. Place interns to weigh in container or directly onto platform. The weight will
now be displayed. As more weight is added, the display will automatically
increase.
`5. Replace the batteries when the scale displays battery symbol.
6. OVERLOAD WARNING:
7. Remove the weight immediately when the scale displays ’EEEEEE’ or damage
to the scale will occur.
TO MAINTAIN
Clean after use with a lightly dampened cloth (Do not use solvents).
Do not place on microwave oven or dish washer, or immerse in water.
TO COUNT
1. To set your scale to parts counting mode, scroll through to weighing by
pressing CAL/MODE key when the display shows zero.
2. Continue to press CAL/MODE key to select the desired parts counting until:
rEF5, rEF1O, rEF2O and rEF5O pieces. After ‘rEF5O’ is displayed, the indicator
will scroll back to gram weighing mode.
3. With the selected parts counting unit still displayed. Put the desired sample
into the bowl or container. Allow the sample to stabilize for about 5 seconds
then press TARE/PRINT key, “C” appears on the bottom left of the display.
The parts counting.
TO INPUT MEMORY
1. Press TARE/PRINT key to make sure the LCD shows zero.
2. Put the 1 st load on to the platform and get the 1st reading.
3. Press ON/MEM key to store the 1st reading, ‘M’ will appear on the upper left
corner of the LCD.
4. The LCD should show zero now, if not, press TARE/PRINT key.
5. Now put the 2nd load on to the platform and get the 2nd reading.
6. Press ON/MEM key again, ‘M’ disappears and the LCD shows the SUM of the
1st and 2nd readings.
7. Now, you can press ON/MEM key again to store the 1st SUM, LCD should go
back to zero and ‘M’ appears again.
8. Put the 3rd load on to the platform and get the 3rd reading.
9. Press ON/MEM key to get the 2nd SUM (of the 1 st, 2nd and 3rd readings)
10. Go through steps I to 6 above for further Operation.
CALIBRATION INSTRUCTIONS
1. Allow the scale to warm up for about 2 minutes
2. Remove all items from the platform
3. When the LCD shows ‘0.0’ and in the gram mode, press and hold the
CAL/MODE key until the LCD shows ‘500.0’.
4. Now put on to the platform the calibration weight (500g)
5. Wait for about 4 seconds and do not disturb the scale as it is performing
internal calibration.
6. The LCD will show ‘PASS’ if calibration is successful.
7. If LCD shows ‘E’, calibration did not succeed, repeat steps 1 to 6 above.
Tested to comply with FCC standards