Precision Tabletop Scale
Capacity: 2000g x 0.1g - Weighing modes: g, oz, ozt, dwt
Thank you for purchasing US-ORBIT-PRO Precision Table Top Scale.
Please read all operation instructions carefully before use.
All items included with this package
SPECIFICATIONS
Max capacity:2000g
Resolution: 01g
Weight units: g, oz, dwt, ozt
Stainless steel platform
Operation temperature: 0~40°C
Green and blue back light Auto Changing
Memory function / indication: M
Counting function / indication: C
Low battery indication:
Protective cover / container
Overload indication: EEEEEE
Power supply: 4 x AAA batteries
Auto oft around 40 seconds if no operation
CONVERT WEIGH WEIGHT UNITS
Press ‘CAL/MODE’ KEY once at a time to select unit in the order of: g > oz > dwt >
ozt > rEF 5 > rEF10 > rEF20 > rEF50 > g
TO WEIGH
1. Place the scale on a firm, flat surface.
2. If using bowl or any other container, place container on platform after
turning on scale. Then press TARE/PRINT key to zero reading.
3. The scale weighs in grams, ounces, dwt or ozt. Select your preference with
the Cal / Mode button.
4. Place interns to weigh in container or directly onto platform. The weight will
now be displayed. As more weight is added, the display will automatically
increase.
`5. Replace the batteries when the scale displays battery symbol.
6. OVERLOAD WARNING:
7. Remove the weight immediately when the scale displays ’EEEEEE’ or damage
to the scale will occur.
TO MAINTAIN
Clean after use with a lightly dampened cloth (Do not use solvents).
Do not place on microwave oven or dish washer, or immerse in water.
TO COUNT
1. To set your scale to parts counting mode, scroll through to weighing by
pressing CAL/MODE key when the display shows zero.
2. Continue to press CAL/MODE key to select the desired parts counting until:
rEF5, rEF1O, rEF2O and rEF5O pieces. After ‘rEF5O’ is displayed, the indicator
will scroll back to gram weighing mode.
3. With the selected parts counting unit still displayed. Put the desired sample
into the bowl or container. Allow the sample to stabilize for about 5 seconds
then press TARE/PRINT key, “C” appears on the bottom left of the display.
The parts counting.
TO INPUT MEMORY
1. Press TARE/PRINT key to make sure the LCD shows zero.
2. Put the 1 st load on to the platform and get the 1st reading.
3. Press ON/MEM key to store the 1st reading, ‘M’ will appear on the upper left
corner of the LCD.
4. The LCD should show zero now, if not, press TARE/PRINT key.
5. Now put the 2nd load on to the platform and get the 2nd reading.
6. Press ON/MEM key again, ‘M’ disappears and the LCD shows the SUM of the
1st and 2nd readings.
7. Now, you can press ON/MEM key again to store the 1st SUM, LCD should go
back to zero and ‘M’ appears again.
8. Put the 3rd load on to the platform and get the 3rd reading.
9. Press ON/MEM key to get the 2nd SUM (of the 1 st, 2nd and 3rd readings)
10. Go through steps I to 6 above for further Operation.
CALIBRATION INSTRUCTIONS
1. Allow the scale to warm up for about 2 minutes
2. Remove all items from the platform
3. When the LCD shows ‘0.0’ and in the gram mode, press and hold the
CAL/MODE key until the LCD shows ‘500.0’.
4. Now put on to the platform the calibration weight (500g)
5. Wait for about 4 seconds and do not disturb the scale as it is performing
internal calibration.
6. The LCD will show ‘PASS’ if calibration is successful.
7. If LCD shows ‘E’, calibration did not succeed, repeat steps 1 to 6 above.
Tested to comply with FCC standards

Other US Balance Scale manuals

US Balance US-750EX User manual

US Balance

US Balance US-750EX User manual

US Balance US-TRADER-PRO 3Kg User manual

US Balance

US Balance US-TRADER-PRO 3Kg User manual

US Balance US-BENCHTOP-PRO User manual

US Balance

US Balance US-BENCHTOP-PRO User manual

US Balance US-TT-1000 User manual

US Balance

US Balance US-TT-1000 User manual

US Balance US-TORPEDO User manual

US Balance

US Balance US-TORPEDO User manual

US Balance US-Storm Quick reference guide

US Balance

US Balance US-Storm Quick reference guide

US Balance US-VELOCITY Quick reference guide

US Balance

US Balance US-VELOCITY Quick reference guide

Popular Scale manuals by other brands

Mesko MS 8148 user manual

Mesko

Mesko MS 8148 user manual

Clatronic PW 3370 instruction manual

Clatronic

Clatronic PW 3370 instruction manual

Omron HN-286 manual

Omron

Omron HN-286 manual

Taylor 5742 instruction manual

Taylor

Taylor 5742 instruction manual

Scale House OCSF-50 user manual

Scale House

Scale House OCSF-50 user manual

Tanita MC-780MA-N instruction manual

Tanita

Tanita MC-780MA-N instruction manual

Duronic BS701 Instructions for use

Duronic

Duronic BS701 Instructions for use

Ernesto EKWC 5 A2 operating instructions

Ernesto

Ernesto EKWC 5 A2 operating instructions

Charder W320 user manual

Charder

Charder W320 user manual

Thunderbird T40-2000 instruction manual

Thunderbird

Thunderbird T40-2000 instruction manual

Kiwi KKS-1155 instruction manual

Kiwi

Kiwi KKS-1155 instruction manual

Create BALANCE BODY ECO user manual

Create

Create BALANCE BODY ECO user manual

Medisana PST manual

Medisana

Medisana PST manual

Coline EB9008 manual

Coline

Coline EB9008 manual

SR Instruments SRScales SRV949 Operating and service manual

SR Instruments

SR Instruments SRScales SRV949 Operating and service manual

Tanita UM-061 instruction manual

Tanita

Tanita UM-061 instruction manual

Gerlach GL 8167 user manual

Gerlach

Gerlach GL 8167 user manual

KERN ITT Operating	 instruction

KERN

KERN ITT Operating instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.