UseTECH FlowTimer+ User manual

FlowTimer+ Connect
FlowTimer+ Interface for Smart Home
and other external systems
Operating Manual

Publisher
usetech GmbH
Tanzplatz 10
D- 55130 Mainz
Phone:
+49 6131 - 921325
Website:
www.use-tech.com
Document
number
FlowTimer+ Connect_Manual_EN_V3
Original Operating Manual
Date of issuance
04.03.2019
Printing date
04.03.2019
Copyright
usetech GmbH
This documentation including all its parts is protected by copyright.
Any use or modification outside the narrow limits of copyright law
without the consent of the company usetech GmbH is prohibited
and punishable by law.
This applies in particular to duplications, translations, microfilming
and storage in electronic systems as well as processing in these.

Table of contents
03/19 FlowTimer+ Connect 1
Table of contents
Table of contents.........................................................................1
1General information.............................................................2
1.1 Explanation of symbols .........................................................2
2Technical data......................................................................4
2.1 Electrical data........................................................................4
2.2 Environmental and climate conditions...................................4
2.3 Lifetime..................................................................................4
3Intended Use ........................................................................5
3.1 Non-approved use.................................................................6
4Basic safety instructions.....................................................7
5System description FlowTimer+ Connect ..........................8
5.1 Content of the FlowTimer+ Connect .....................................8
6Installation............................................................................9
6.1 Electrical connection .............................................................9
7Operation and Function.....................................................10
7.1 Operating conditions ...........................................................10
7.1.1 Normal operation...........................................................................10
7.1.2 Restarting the system....................................................................10
8Troubleshooting, Maintenance .........................................11
8.1 Maintenance........................................................................12
9Packaging, Transport, Storage .........................................13
10 Disposal..............................................................................14
11 EC Declaration of Conformity ...........................................15

General information
03/19 FlowTimer+ Connect 2
1 General information
The operating instructions describe the entire life cycle of the
system. Keep this manual in such a way that it is easily accessible
to any user and available to any new owner of the system.
NOTE
The operating instructions contain important
information on safety!
Non-observance of these instructions can lead to dangerous
situations.
The operating instructions must be read and understood.
1.1 Explanation of symbols
DANGER
Warns of imminent danger!
Failure to do so will result in death or serious injury.
WARNING
Warns of a potentially dangerous situation!
Failure to do so could result in serious injury or death.
CAUTION
Warns of a possible hazard!
Failure to do so may result in moderate or minor injury.
NOTE
Warns of material damage!
Failure to do so may result in damage to the system or
equipment.

General information
03/19 FlowTimer+ Connect 3
indicates important additional information, tips and
recommendations that are important for your safety and the
proper functioning of the system.
refers to information in this operating manual or other
documentation.
Action steps
The defined sequence of steps makes it easier for you to
use the system correctly and safely.
Outcome
Here you will find the result of a sequence of steps
described.

Technical data
03/19 FlowTimer+ Connect 4
2 Technical data
2.1 Electrical data
Input voltage: 100 - 240V~
Power consumption: < 0.25 W
Supply connection: Micro USB socket
2.2 Environmental and climate conditions
Ambient temperature: +5°C - 40°C
Protection class: IP20
Location: only suitable for indoor use
2.3 Lifetime
The function of FlowTimer+ Connect must be checked by a
qualified technician at the scheduled intervals (see also chapter
9.3).

Intended Use
03/19 FlowTimer+ Connect 5
3 Intended Use
Please observe the notes in this operating manual as well as the
operating conditions and permissible data in the data sheet so that
the system functions perfectly and remains operational for a long
time. In case of non-observance of these instructions as well as in
case of inadmissible interventions into the system, any liability on
our part is void, as is the warranty on the system and accessories!
FlowTimer+ Connect connects the FlowTimer+ I/O connector to an
external switched mains voltage.
If the supplied USB power supply is supplied with mains voltage,
the FlowTimer+ will lock up immediately.
An alarm reset can only be performed via the connected
FlowTimer+ or its supply voltage.
The precondition for this is also that the mains voltage for the
FlowTimer+ Connect has been switched off at least 1 minute
before.
Any other use or use going beyond this shall be deemed improper
use. The usetech GmbH is not liable for damages resulting from
this. The risk is borne solely by the user.

Intended Use
03/19 FlowTimer+ Connect 6
3.1 Non-approved use
Unapproved use in the sense of a foreseeable misuse shall be
deemed to be improper use:
The I/O connection cable of the FlowTimer+ Connect is only
suitable for connection to the FlowTimer+.
The FlowTimer+ Protect is not directly supported, but only
indirectly via a group alarm via FlowTimer+ and FlowTimer+
Hub.
No telephones, ISDN, other devices or adapters may be
connected.
The USB plug of the I/O connection cable may only be operated
with the supplied USB power supply. Other 5V voltage sources
(PC etc.) must be galvanically isolated for safety reasons!

Basic safety instructions
03/19 FlowTimer+ Connect 7
4 Basic safety instructions
WARNING
Electrical voltage can be life-threatening.
The installation of a stationary power supply must be
carried out by a qualified electrician.
The system must be commissioned and, if necessary,
adapted by a specialist. The local conditions must be
observed.

System description FlowTimer+ Connect
03/19 FlowTimer+ Connect 8
5 System description FlowTimer+ Connect
5.1 Content of the FlowTimer+ Connect
Fig. 5.1: Content of the FlowTimer+ Connect
1
USB power supply unit
2
Interface electronics in USB connector
3
USB-I/O connection cable
4
I/O connector plug

Installation
03/19 FlowTimer+ Connect 9
6 Installation
6.1 Electrical connection
If the I/O plug is plugged into the socket, this must cause
a clicking noise. If not, please check again whether the
plug is correctly engaged!
When disconnecting connections, please note to press
the locking lugs of the I/O connectors!
Plug the USB plug with integrated electronics (2) of the
FlowTimer + Connect I/O cable (3) into the USB power supply
(1).
Plug the I/O connector of the FlowTimer+ Connect I/O cable (3)
into the I/O connector of a FlowTimer+.
Plug the power supply unit (1) into a suitable switchable socket
(Smart Home switchable socket, etc.).

Operation and Function
03/19 FlowTimer+ Connect 10
7 Operation and Function
7.1 Operating conditions
7.1.1 Normal operation
An operation of FlowTimer+ Connect is not necessary.
FlowTimer+ Connect connects the FlowTimer+ I/O connector to an
external switched mains voltage.
If the supplied USB power supply is supplied with mains voltage,
the FlowTimer+ will lock up immediately.
An alarm reset can only be performed via the connected
FlowTimer+ or its supply voltage.
The prerequisite for this is also that the mains voltage for the
FlowTimer+ Connect has been switched off at least 1 minute
before.
7.1.2 Restarting the system
Unplug the AC adapter (1) from the wall outlet or disconnect the
power supply.
Wait 1 minute
Restore power supply

Troubleshooting, Maintenance
03/19 FlowTimer+ Connect 11
8 Troubleshooting, Maintenance
If the connected FlowTimer+ disconnects without a reason being
found, disconnect the I/O connector (4) of FlowTimer+ Connect
from the I/O connector of FlowTimer+ to prevent a malfunction of
the FlowTimer+ Connect electronics.
The mains voltage of the FlowTimer+ Connect plug-in
power supply (1) must be switched off for at least 1
minute before the connected FlowTimer+ can be reset!
CAUTION
The USB plug of the I/O connection cable may only be
operated with the supplied USB power supply.
Other 5V voltage sources (PC etc.) must be galvanically
isolated for safety reasons!

Troubleshooting, Maintenance
03/19 FlowTimer+ Connect 12
8.1 Maintenance
interval
plot
Monthly
Check entire system restart and function
(see "FlowTimer+ Set instructions").
Biennial
The FlowTimer+ Connect should be
checked by an installer after two years at the
latest.

Packaging, Transport, Storage
03/19 FlowTimer+ Connect 13
9 Packaging, Transport, Storage
Transport damage!
Inadequately protected systems can be damaged during
transport.
Protect the system from moisture and dirt and transport it
in shockproof packaging.
Avoid exceeding or falling below the permissible storage
temperature.
Protect electrical connections from damage with
protective caps.
The system must be transported or stored in its intended packaging
until it is installed.
Incorrect storage can cause damage to the system!
Store system dry and dust-free!
Storage temperature: -30°C to +60°C

Disposal
03/19 FlowTimer+ Connect 14
10 Disposal
Information on the Waste Equipment
Ordinance
Act on the placing on the market, take-back and environmentally
sound disposal of electrical and electronic equipment (Elektro-
und Elektronikgerätegesetz - ElektroG).
Note on the Electrical and Electronic Equipment Act
(ElektroG):
Please dispose of old equipment at a municipal collection
point as required by law, or hand it over to your local dealer
free of charge.
Disposal with household waste is expressly forbidden
according to the Old Equipment Ordinance!
You can return devices received from us to us free of charge
after use by sending them back sufficiently franked by post to
the address given in the imprint.
Old appliances that contain harmful substances are marked
with the symbol of a crossed-out dustbin.

EC Declaration of Conformity
03/19 FlowTimer+ Connect 15
11 EC Declaration of Conformity
after:
Annex III of the EC Low Voltage Directive 2014/35/EU.
Annex I of the EC Directive on Electromagnetic Compatibility 2014/30/EU.
RoHS Directive 2011/65/EU on the restriction of the use of certain hazardous
substances in electrical and electronic equipment.
The
usetech GmbH
Tanzplatz 10
D-55130 Mainz
declares that
Product Name: Flowtimer+ Connect
Type: V1.2
Year of construction: 2017
complies with the provisions of the above-mentioned EC Directives.
The following standards and technical specifications have been applied:
DIN EN 61326-1; VDE 0843-20-1:2013-07
Date: 31.07.2017
Name: Dipl. Ing. (FH) Stefan Windisch
Function: CEO
Signature:___________________________
Other manuals for FlowTimer+
3
Table of contents